| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹18.1 L+₹1.3 L (7.63%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | L3₹18.6 L+₹1.8 L (10.8%)Rejected-Finance | L3 | Rejected-Finance Other than lowest tenderer | |
| 4 | L4₹25.5 L+₹8.7 L (52.1%)Rejected-Finance 50A 7B 5C UMARPUR NIWA DHOOMANGANJ PRAYAGRAJ UP | PRAYAGRAJ | UTTAR PRADESH | 211011 | L4 | Rejected-Finance Other than lowest tenderer | |
| 5 | L5₹25.8 L+₹9.0 L (53.7%)Rejected-Finance | L5 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Jun 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Lt Col Aditya Gorhe
GE Utility Bathinda
REPAIR/MAINT OF LT NETWORK (UG CABLES/OH LINES) AND CONNECTED WORK AT MD ACCOMMODATION ZONE B UNDER GE UTILITY BATHINDA.
2023_MES_596374_1
8706/2023-24/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Garrison Engineer Utility Bathinda
class D cat b i
9 documents required · 9 mandatory
₹500
Garrison Engineer Utility Bathinda
₹60,000
Yes
4 Aug 2023
18 May 2023
19 Jun 2023
18 May 2023
16 Jun 2023
2 Jun 2023
Amount
Opening / Disconnecting the electrical connection of defective / burnt out underground LT cable of any size & any core from main switch / DB / junction box / LT panel / L T O/H line etc. Taking out the length of cable ( to be required) from existing loop, cutting the defective portion of cable ,providing (to be required) thimbles / connectors at cable end and reconnecting the cable in previous location with existing main switch / DB / Junction box / LT panel / OH line etc. all as directed by Engineer-in-charge. Note:- (i) The cost of excavation & earth work,returning filling, in relaying of sand / bricks and cost of drawing the( to be required) length from protection pipe ,breaking of brick work / concrete / plaster ( to be required) and redoing ( to be required) for work to match the existing surface shall be deemed to be included in quoted rates and nothing extra should be paid on this account.(ii) Additional cable / protection pipe if required at site shall be measured and paid seperatly. (iii) During currency period of contract , contractor shall depute Two Electrician & four helpers for attending the complaints regularely (daily based) for serial item No. 1.00, 2.00, 3.00, 4.00 & 5.00 .The rates of this aspect is included in serial item no. 1.00, 2.00, 3.00, 4.00 & 5.00 and nothing shall be extra paid on this account . Please note one time payment shall be made to contractor for these items.if any fault / defects occured , contractor shall rectify / replace the same without any extra cost in terms of condition 46 of IAFW-2249 of General condtion of contracts.
Dismantling / Disconnecting / removing the faulty / burnt out overhead one No. conductor of any type / size from insulator on HT / LT pole any type after taking proper shutdown, removal of tree / branches if any fell on Over Head Line, loose the binding wire in each insulators and disconnecting cable connection if any, remove the burnt / damage conductor / earth wire, making joint with New ACSR conductor of suitable size as directed, restretching all the loose spans for tightening to maintain proper sag, binding conductor & earth wire with insulators with new binding wire of existing size, making connection of existing LT / HT cable in old position including cutting of tree branches , if any and removing from site and testing overhead line complete all as directed.
All as Srl iem No 2 here-in-before but for two Nos conductor.
All as Srl iem No 2 here-in-before but for three Nos conductor.
All as Srl iem No 2 here-in-before but for four Nos conductor . Notes for serial item No.02,03,04 & 05 of BOQ : (i) Cost for attending fault, cutting and removal of broken piece of tree / branches, disconnection and jointing of binding wire with insulator, restretching required conductor, making connection with existing cable deemed to be included in quoted rates and nothing shall be paid extra on this account. (ii) If New ACSR conductor,Earth wire requires for this item shall be measured and Paid seperately under appropriate items of Schedule'A' BOQ. (iii) Cost of binding wire and insulators is included in this item and nothing shall be paid extra on this account.
Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for pipe line, cable trenches etc not exceeding 10 sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated material to a distance not exc 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Material & labour sand cushioning using clean Fine River sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cable complete all as specified and directed. ( Note:- Punned thickness shall be considered for payment purpose)
Supply and laying Best quality, locally available, sub class ‘B’ clay bricks (Old Size) for cable protection cover, laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover, Class LV, Type 1, Flat size 250mm x 150mm x 40mm complete all as specified and directed.
Re-laying old serviceable bricks for cable protection , laid flat and dry in trenches over the cable , perpendicular to the direction of cable complete all as specified and as directed.
Taking out old unservicable under ground LT XLPE / PVC cable of any size from trenches / wall / roof / road / pipe / pole / DB including taking out of brick layer of cable protection complete all as directed.
Relaying of old serviceable under ground PVC/XLPE LT cable of any grade , any size laid in trenches / fixed to wall / pole / roof / laid in floor including necessary connections and thimbling complete all as specified and as directed.
Supply and laying or fixing or laid in trenches / ducts / through pipes / in floors / under roads / hard standing /along poles and testing XLPE, LT Cable, with PVC outer sheath Type-I as per IS - 5831, insulated stranded aluminium conductor as Per Class-2 of IS - 8130 served with and inner sheathining of PVC tape- ST-I as per IS-5831 color Red, Yellow, Blue & Black ,armoured with Galvanised steel strip or wire and over all PVC sheathed stranded conductor conforming to IS-1554 (Part-I & II) with latest amendments of Size cross sectional area 400 Sqmm 3.5 core ,1100 volts grade heavy duty complete all as specified and as directed.
All as per serial item No. 15 above but for cross sectional area 185 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 150 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 120 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 95 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 70 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 50 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 25 Sqmm 3.5 core ,1100 volts grade.
All as per serial item No. 15 above but for cross sectional area 16 Sqmm 4 core ,1100 volts grade. Note fo serial item No. 15 to 23: Excavation and earth work shall be measured and paid separately under respective item.
Un binding from old insulators and taking down old unservicable insulators and re–stretching only existing ACSR of any size on LT poles including binding the ACSR with new insulators with and including aluminium binding wire 2mm dia complete all as specified and as directed. Note :- (i) The rate of aluminium binding wire 2mm dia is included in this item and nothing shall be paid extra on this account. (ii) New insulators shall be measured and paid seperately under respective item of this scheule of works of BOQ.
All as per srl item No. 24 here-in-before but re–stretching only existing GI earth wire 4 mm dia on LT / HT Poles including binding with 1.63 mm dia GI binding wire all as specified and as directed. Note :- The rate of 1.63 mm dia GI binding wire is included in this item and nothing shall be paid extra on this account.
Cutting / trimming of tree branches upto 1.50 metre distance on each side and 3.00mtr distance on both sides of LT over head lines including collection and removal from road complete all as directed. Note : For measurement and payment purpose each span shall be considered as 40.00 mtr. Span.If the length of span is less than 40.00 mtr measurment and payment shall be considered proportionally.
Supply and fixing in repair shackle type porcelain, vitreous, white, brown or green insulator of size 75mm height, 90mm dia for working pressure 1100 volts including galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm complete all as specified and directed. Note:- The rate of galvanized mild steel strips 31mm x 3 mm, washer, insulator bolts and nuts, dia of bolt 12mm is included in this item and nothing shall be paid extra.
Supply and fixing in repair loop type insulator, vitreous porcelain white, brown or green with over all dimension 65mm x 90 mm , clearance dia of bolt 16 mm complete all as specified and directed.
Taking out old broken PCC Pole of any size , embeded with PCC foundation complete all as specified and directed.
Supply and errecting Pre Stressed concrete Pole 9.00 Mtr long ,102mm x 172 mm at top ,102mm x 279 mm at bottom , class 10 complying with requirements of IS-1678-1978 including painting of poles with two coats of radiant paint over a coat of primer with black and white strips 30 cm wide each up to 1.5 mtr height from top of PCC foundation block and numbering of poles including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and directed. Note :- (i) The T & P / vehicles will be arranged by the contractor for transporting the pole if required and the cost deemed to be included in the quoted rates. (ii) The cost of excavation , returning filling and removal of earth work is included in this item and nothing shall be paid extra on this account.
Material and Labour for PCC (1:4:8) type D2 using 40mm graded crushed stone aggregate as in foundation of poles etc, filling and mass concrete including necessary form work complete all as specified and directed.
Material and Labour for PCC (1:2:4) type B1 using 20 mm graded crushed stone aggregate as in coping, of poles/struts etc including necessary form work complete all as specified and directed.
Supply and fix in repair Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed. Note : The rate of one primer coat, one under coat and one finishing coat of paint is included in this item.The payment shall be made as per actual weight of material. During weighting the weight of paint and primer shall not be considered for payment purpose.nothing shall be extra paid on this account.
Supply and fix in repair stay assembly comprising of GI stay bow 14 mm dia, 40 cm long complete with accessories as shown in Electrical plate No 1 of SSR Part - I using galvanised stay rod 20 mm dia, 215 cm long with threaded ends GI nuts, bolts, washers, stay plate 30 cm x 30 cm x 6 mm thick ,2 Nosf thimbles, MS clamps made out of 50mm x 6 mm flat iron, loop stay insulator, stay wire 7/8 SWG complete including painting all exposed surfaces of MS work including two coats of aluminium paint over a coat of red oxide zinc chromate primer complete all as specified and directed. Note : Loop type insulators, Earth work and concrete work shall be measured and paid for separately under the respective item of BOQ.
Supply , fixing and stretching in repair ACSR of any size as per site requirement on existing HT/LT poles including binding on existing insulator with aluminium binding wire 2mm dia complete all as specified and directed by Engineer-in-charge. Note :- 1. For measurement and payment purpose only the weight of ACSR shall be considered .The weight of aluminium binding wire 2.00mm shall not be considered.2. The rate of aluminium binding wire 2.00mm is included in this item and nothing shall be paid extra on this account.(ii)(ii) New insulators if required shall be measured and paid seperately under respective item of this scheule of works of BOQ.
Supply , fixing and Stretching in repair 4mm dia GI earth wire / guard cradles on existing HT / LT poles binding with and including GI binding wire 1.63 mm complete all as specified and directed. Note :- (i) For measurement and payment purpose only the weight of 4mm dia GI earth wire / guard cradles shall be considered .The weight of GI binding wire 1.63 mm shall not be considered. (ii) The rate of GI binding wire 1.63 mm is included in this item and nothing shall be paid extra on this account.
Material and Labour for in replacement Danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20cm x 15cm size complete all as directed.
Material and Labour for in replacement Danger notice plate 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25 cm x 20 cm size complete all as directed.
Cleaning and preparation of old painted surface of LT PCC Street light Pole up to 1.50 mtr height from top of PCC foundation block, making alternative black and white strips on pole with Radiant paint ( each strip 30cm hight ) and writing pole nos. including applying one coat of cement base paint on exposed surface of PCC coping and foundation blocks complete all as specified and directed.
Supply and fixing PVC separator suitable for 3/4 way conductor complete all directed.
Supply and fixing PVC separator suitable for 5/6 way conductor complete all directed.
Supply and laying or fixing in repair GI tubing light grade 40 mm dia for cable protection including fitting complete with flat iron clamps size of flat iron 25mm x 4mm, nuts, bolts & washers fixed to poles / along wall / floor / under road / across the drain or nallah / laid in trench complete all as specified and directed.
All as per serial item No. 42 above but for 50 mm bore GI tubing light grade.
All as per serial item No. 42 above but for 80 mm bore GI tubing light grade.
All as per serial item No. 42 above but for 100 mm bore GI tubing light grade.
Demolitiong of old earth pit and Material and Labour Earthing complete with galvanised iron earth plate electrode of size 600mm x 600mm x 6mm buried directly in ground (earth pit not less than 2.25 mtr deep below ground level ) with top edge of the plate not less than 1.5 metre below normal ground level, connected to and including GI strip 32mm X 6 mm by means of GI bolts/nuts/washers, protected by 40 mm bore GI light grade pipe. Earth plate shall be surrounded by alternate layer of charcoal or coke and common salt 15 cm thick all around bottom and top. 20 mm GI light grade pipe for watering and including funnel, wire mesh,RCC cover & frame, PCC (1:3:6) type C1 (using 20 mm graded crushed stone aggregate) as in earthing pit including necessary excavation & earth work, all as specified & shown in electrical plate No. 3 of SSR Part – I. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner.
Supply and fix in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required by using 32 mm x 6 mm GI strip complete all as specified and directed.
Supply and fixing in repair MCCB, 3 phase, 4 pole, 415 volt of capacity 630 Amp, with spread terminal with incoming and outgoing phase insulation sleeves short circuit, shunt trip coil with contactor, breaking capacity not less than 50 KA , thermal setting 80-100%, Ics-100% Icu confirming to IEC-947, IS-13947 type OH, including thimbles, nuts, bolts, washers etc disconnecting and making incoming, outgoing connections complete all as specified and directed.
All as per serial item No. 48 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 400 Amp, breaking capacity not less than 50 KA.
All as per serial item No. 48 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 250 Amp, breaking capacity not less than 25 KA.
All as per serial item No. 48 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 200 Amp, breaking capacity not less than 25 KA.
All as per serial item No. 48 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 100 Amp, breaking capacity not less than 25 KA.
All as per serial item No. 48 above but for MCCB, 3 phase, 4 pole, 415 volt of capacity 63 Amp, breaking capacity not less than 25 KA.
Supply and fixing in repair MCB suitable for 415 volts AC supply, 63 Amps, Four Pole 'C' series with over load and short circuit protection and rupturing capacity not less than 9/10 KA. complete all as specified and directed.
Material and labour for making the hole under road and hard standing for laying and incluidng inserting Galvanised steel light grade pipe of 100 mm dia including all fittings as required at site by mechanical drill system or Auger system and making the surface good as per existing surface completed all as specified and directed. Note : The rate of Galvanised steel light grade pipe of 100 mm dia is included in this item and nothing shall be paid extra on this account.
S&F heat shrinkable straight through cable joint for XLPE UG cable 1100 volt 16 Sqmm 4 core to 50 Sqmm 3.5 core complete all as directed.
S&F heat shrinkable straight through cable joint for XLPE UG cable 1100 volt 70 Sqmm 3.5 core to 150 Sqmm 3.5 core complete all as directed.
S&F heat shrinkable straight through cable joint for XLPE UG cable 1100 volt 185 Sqmm 3.5 core to 240 Sqmm 3.5 core complete all as directed. Make for serial item No. 57 to 59 : RAYCHEMS / DENSONS / M-SEAL / BIRLA -3M / SIEMEN
M/s NIRMAN BUILDERS
Sandeep Enterprises
SS CONSTRUCTION
L H ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .