Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.4 LAccepted-AOC A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | L1 | Accepted-AOC being lowest | |
| 2 | L2₹17.8 L+₹1.7 L (10.6%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹17.9 L+₹1.8 L (10.9%)Rejected-AOC RZ 140 A EAST SAGARPUR STREET NO 7 8 NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-AOC Rejected | |
| 4 | L4₹18.9 L+₹2.8 L (17.6%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L4 | Rejected-AOC Rejected |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
15 May 2020, 6:00 pmClosed
GE U Water Supply Delhi Cantt
GE U Water Supply Delhi Cantt
REPAIR REPLACEMENT REROUTING OF EXTERNAL WATER SUPPLY PIPE LINE AND CONNECTING ACCESSORIES AT FOL DEPOT 226 1811 PIONEER ESD DEPOT UNIT AND OTM BLDGS AND SUBRAMANIYAM MD ACCN AND ADJOINING AREA IN THE AREA OF AGE U WATER SUPPLY NO I UNDER GE U
2020_MES_339039_1
GE/WS/D-06 OF 2020-21
Open Tender
Civil Works
Item Rate
180 days
GE U Water Supply Delhi Cantt
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE U Water Supply Delhi Cantt
₹40,000
Yes
23 Jul 2020
16 Apr 2020
18 May 2020
16 Apr 2020
15 May 2020
30 Apr 2020
Amount
Excavation in trenches not exc 1.5 M wide and not exc 1.5 M in depth for pipe line, etc in soft/ loose soil getting out and levelling of bottom surface to required level all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
Excavation in trenches by cutting of road crossing, PCC hard standing for taking out/laying of pipe lines including PCC (1:2:4) type B-I (with 20 mm graded aggregate) as in coping, grouting, finished even and smooth without using extra cement as on brick work/flooring complete making good the existing surface complete all as specified and as directed.
Taking up CI/DI /GI/MS watermain pipes including all fittings with spigot socket ends and lead/rubber tyton joints and depositing to MES store yard complete all as specified and as directed. Note:- Excavation & earth work shall be measured & paid separetely under respective items
80 mm Bore
100 mm Bore
150 mm Bore
250 mm Bore
Supplying, Laying, jointing, testing and commmisioning DI Pipe of following sizes as per IS 8329-2000, class K-7 With inside cement mortar lining spigot and socket ends laid in trenches complete all as specified and as directed .
80 mm Bore
100 mm Bore
150 mm Bore
250 mm Bore
M&L for DI fittings/specials such as Tees, bends ,any type, radius and angle/tapers any type, collars,tail pieces,caps and plugs upto 250 mm bore confirming to IS: 9523 complete all as specified and as directed. Note:- Tyton joints shall be measured and paid seperately.
M&L for laying and jointing CI Fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars,tail pieces,caps and plugs conforming to IS: 1538-1993 complete all as specified and as directed.
Material & Labour for Rubber Gasket (Tyton) joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
80 mm Bore
100 mm Bore
150 mm Bore
250 mm Bore
Labour for cutting/tapping of CI/DI Pipe in position for reducing to required length for insertion of new tees,branches etc complete all as specified and as directed .
80 mm Bore
100 mm Bore
150 mm Bore
250 mm Bore
Supplying, fixing, jointing & testing cast Iron Sluice Valve of following sizes, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body confirming to IS 14846 -2000, having stainless steel spindle with cast iron operation wheel at top complete with Nuts, Bolts, washers and rubber gaskets of following sizes including taking out of unserviceable sluice valve complete all as specified and as directed.
80 mm Bore
100 mm Bore
150 mm Bore
250 mm Bore
All as per item No 11 as above but size 100mm PN-1.6 complete all as specified & directed
Supply, fixing, jointing and testing of Cast iron Non Return valve of following Sizes without by pass arrangement , Swing type, confirming to IS 5312, flanged ends, pressure rating PN 1.0 complete including taking out unserviceable NRV complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item.
100 mm Bore
150 mm Bore
Material & Labour for run lead joint including jointing material for CI/DI Pipe of following sizes complete all as specified and as directed .
100 mm Bore
150 mm Bore
250 mm Bore
250 mm Bore
Taking up or down GI steel tubing with connections of following sizes from trenches/walls & Relaying in the same position including cleaning throughly and removal of all blockages if any complete all as specified and as directed. Note:- Excavation & earth work shall be measured & paid separetely.
15 mm GI Tubing
20 mm GI Tubing
25 mm GI Tubing
40 mm GI Tubing
50 mm GI Tubing
Supply and fixing in replacement Gun metal gate valve, with iron wheel head screwed both ends for iron pipe, ISI Marked as per IS-778 of following sizes complete all as specified and as directed.
15 mm Bore
20 mm Bore
25 mm Bore
40 mm Bore
50 mm Bore
Supply & Fixing PVC ball valves long lever handle with screwed both sides for iron pipe and fixed, including taking out unserviceable ball valve bore of pipe of following sizes complete all as specified and directed by Engineer-in-Charge.
15 mm Bore
20 mm Bore
25 mm Bore
40 mm Bore
50 mm Bore
Supply and installation of flanged ends strainer/dirt box, with stainless steel mesh suitable for water meter for potable water supplies on up stream of water meter to avoid foreign material entering into meter including taking out unserviceable of following sizes complete all as specified and as directed at site by the Engineer-in-Charge.
50 mm Bore
80 mm Bore
100 mm Bore
150 mm Bore
Supply, installation and testing of water meter in replacement, of following sizes, Woltman type class-B, flanged ends, with Nuts, Bolts, washers and rubber gaskets fixing in horizontal/inclind/vertical position, including cutting of pipes complete all as specified and as directed at site by the Engineer-in-Charge. Note:- Flanged joints with jointing material shall deemed to be included in the quoted unit rates.
50 mm Bore
80 mm Bore
100 mm Bore
150 mm Bore
Supplying , laying , jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes complete all as specified and as directed. Note:- MS Flanges incl fabrication work will be measured and paid separately.
100 mm Bore
200 mm Bore
Supplying, fixing in replacement MS flange 16 mm thick duly welded including Nut, Bolts and washers on ends with MS pipe complete all as specified and as directed.
100 mm Bore
200 mm Bore
Construction of valves pit chamber having internal dimension 1200 mm X 1200 mm x 1200 mm with PCC (1:4:8) using 40mm graded mechanical crushed stone aggregate for foundation 15 cms thick, brick wall 23 cm thick built in CM (1:6), 10mm thick rendering in cement mortor 1 : 4 internally and externally upto 15 cm below GL, PCC (1:2:4) type B1 using 20mm graded stone aggergate as in coping for grouting MS frame including 03 mm thick MS top sheet cover with locking arragnement including 50 mm pad lock with double key angle iron including painting steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer with, including necessary excavation and earth work in any type soil, returning filling and removal of surplus soil to a distance not exceeding 50 mtr complete all as specified and as directed.
Supply and fixing in replacement high pressure PTMT float valve, with epoxy coated aluminium rod and high density plastic ball of following sizes complete all as specified and as directed.
15 mm Bore
20 mm Bore
25 mm Bore
Supply and fixing in replacement Cast Iron foot valve, of size 100 mm bore, flanged ends, swing type opration with rubber sheet, as per IS : 4038 complete all as specified and as directed . Note :- Flanged joints comlete with jointing material shall deemed to be included in the unit rate of this items.
Cutting and screwing the existing steel tubing 15 to 50 mm bore for addition and alteration or lengthening screw on pipe to form connector compete all as specified and as directed.
Supply and Fixing MS frame including 3mm thick MS sheet top cover with locking arrangement, MS frame made out of 40*40*6mm thick angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers complete all as specified and directed by Engineer-in-Charge.
M&L for fabrication (welding work ) of MS Header/ any size upto 350mm MS pipe at various pump house site for arresting leakges on header complete all as specified and directed by Engineer-in-Charge.
An amount of Rs 174098.00 shall be deducted from BOQ on account of schedule of credit
Ashish Sehgal and Co.
Deven Associates
Rahul Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .