| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹38.9 L+₹2.4 L (6.59%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 | |
| 3 | L3₹39.0 L+₹2.5 L (6.79%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 | |
| 4 | L4₹39.1 L+₹2.6 L (7.12%)Rejected-AOC | L4 | Rejected-AOC Rejected being L4 | |
| 5 | L5₹39.1 L+₹2.6 L (7.14%)Rejected-AOC | L5 | Rejected-AOC Rejected being L5 |
Tender Value
₹34 L
EMD Value
₹68,000
Closing Date
23 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 867 EWS
GE 867 EWS C/O 99 APO PIN-913867
SPL REPAIR TO BLDG NO P-277 (1 TO 4) AT KALIMPONG UNDER GE 867 EWS
2023_MES_610553_1
GE/867/TOKEN/09 OF 2023-2024
Open Tender
Civil Works
Item Wise
180 days
KALIMPONG
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE 867 EWS
₹68,000
20 Sept 2023
25 Jul 2023
25 Aug 2023
25 Jul 2023
23 Aug 2023
8 Aug 2023
25 Jul 2023 - 5 Aug 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge and thickness including Nainital or similar pattern roof coverings complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based steel sheet (AZ-150) of approved profile of corrugation, 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws all as specified and directed by Engr-in-Charge. Make : Colour Roof India Ltd/Jindal/JSW Colouron Plus/TATA
S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering, eaves board, ridges, hips,valley gutters, drip and straight flashing cladding to wall etc, fixed with self tapping screws all as specified and directed by Engr-in-Charge. Make : Colour Roof India Ltd/Jindal/JSW Colouron Plus/TATA
Dismantling wall and ceiling boards (fiber, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness including cover fillet complete all as specified and directed.
Dismantling timber fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section all as specified and directed.
S&F false ceiling with powder coated exposed GI grid suspension system (E-Grid T-2430 or equvalent load carrying capacity with mid span deflection not exc. 1/360 span with hanger spacing of 1200mm c/c) consisting of main runner 3600mm long, cross Tee 1200mm/600mm long and wall angle. The main runners to be placed @ 1200mm, the cross Tee 1200mm will be inserted in the pre cut slots of main runner at a regular interval of 600mm to form a modular grid of 1200mmX600mm. Additional cross Tees of 600mm shall be placed perpendicular to the cross tee 1200mm long to finally form a grid of 600mmX600mm. Suspensor system (Grid) made out of GI sheet main Tee of size 23.5mmx38.50mm X0.36mm and cross Tee of size 23.5mmX23.5mmX0.36mm and angle size 19mmx19mmX0.36 mm. Grid of modular size 600mmX600mm shall be supported by 4 mm dia G.I. wire from purlins/soffit with and including 4mm thick high pressure steam cured non asbestos fiber cement designer ceiling board (Density>1200Kg/Cum) of size 595mmX595mm, confirming IS 14862 & Type B Category III of ISO 8336, tested as per AS 1530 part 3 & BS-476 Part 4, 5, 6, 7 & 8, complete all as per manufacturer's instruction all as specified and directed by Engr-in-Charge. (Make : Everest or equvalent as approved by GE)
Dismantling wrought iron or mild steel work of any description all as specified and directed.
S&F Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed
S&F Mild steel plates, plain or chequered, 5mm thick or over in thickness in available sizes all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long
M&L for roughening surfaces of old concrete floor by picking,sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar 1:6 complete all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to IS-13712, grade B-II(a) (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm in vertical surface such as skirtings, dados and riser to steps etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing ) removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M&L for non skid ceramic coloured tiles 7 to 8 mm thick premium quality conforming to relevant IS (square/ rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the surfaces of tile over and including 20 mm thick screed bed in cement mortar (1:6) complete all as specified and directed.
Taking down cement plaster on brick or stone masonry surfaces of walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar (1:6) on stone masonry surfaces or surfaces other than fair faces of brick work, rendering finished even and smooth (without using extra cement) complete complete all as specified and directed.
M&L 20 mm thick rendering ( in two coats 10mm+10mm) on fair faces of brick work or concrete surface in cement mortar (1:4) on external wall finished even and fair mixed with integral water proofing compound @ 3% by weight of cement in 2nd coat or in the manner specified by the manufacturer and in the proportions indicated all as specified and as directed. Note:-WPC will be measured and paid separately as supply only.
Supply only integral water proofing compond all as specified and as directed.
M&L Rendering 5mm thick on fair faces of brick work or concrete surfaces cement mortar (1:3) on concrete surface as in ceiling/chajja and RCC surfaces , to be finished even and smooth (without using extra lime or cement)complete all as specified and directed.
M&L for preparation of surfaces of wall and applying two coats of oil bound distemper over 3 mm thick layer of wall care putty (Birla white or equivalent) all as specified and directed.
M&L for preparation of surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L preparation of surfaces of ceiling and applying two coats of white wash complete all as specified and directed.
M&L preparation of surfaces of walls and applying two coats of white wash complete all as specified and directed.
Demolition of brick work or stone/boulder masonary buit in cement mortar including all quions ,arches ,pillars etc but excluding ashler facing dressed stone work and precast concrete and directed.
M&L for brick work with fly ash bricks straight or curved on plan exc 6 m straight or curved fly ash bricks built in cement mortar (1:6) complete all as specified and directed.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in bed blocks for grouting hold fasts , coping, filling in pressed steel chowkat or similar work including necessary form work as required complete all as specified and directed.
Demolition of reinforced concrete of any description and in any position not otherwise specifically provided for including cutting of reinforcement as required to facilliate demolition complete all as specified and directed.
M&L for reinforced cement concrete (nominal mix) type A1 (1:1½:3) (20mm graded crushed stone aggregate) as in Chajjas and the like complete all as specified and directed.
Use & Waste of formwork to Chajjas, chullah hoods, troughs and similar items including edges rough finished surfaces complete all as specified and directed.
S&F of TMT bars 10 mm dia and over, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
S&F of TMT bars 6 mm to 8 mm dia, cut to length , bent to shape required , including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc. laid bedded and pointed in any mortar all as specified and directed.
M & L Granite (of any type) work 20MM thick (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr - in - Charge.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M&L for 100mm thick Cement concrete type D-2, (1:4:8) as in sub base all as specified and directed.
M&L for coloured & polished chequred cement concrete tiles 30cmX30cmX25mm thick set jointed and pointed in neat cement slurry as in floors including 20mm thick screed bed CM (1:6) all as specified and directed.
M&L for machine cut Kota stone slab flooring 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing and exposed edges of kota stone shall be rounded complete over and including 20 mm thick screed bed or bedding layer in CM (1:6) finished even and rough all as specified and directed.
M&L for machine cut Kota stone slab as in vertical surfaces such as dado/skirting, 17-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including grinding rubbing and polishing and exposed edges of kota stone shall be rounded complete over and including 15 mm thick backing plaster in CM (1:4) finished even and rough all as specified and directed.
M&L for 50 mm thick PCC (1:3:6) type C-2 using 40mm graded crushed stone agg as in plinth protection/ path laid slope of 1 in 12 and finshing cement concrete surface even and smooth without using extra cement with and including all necessary form work to divide the area in panels, finishing exposed edges fair or rounding or chamfering of exposed edges or as directed by engr -in-charge.
M&L for PCC (1:3:6) type C-1 (using 20 mm graded crushed stone aggregate) as in surface channels, drains including all necessary form work complete all as specified and directed.
Demolition and breaking up old broken , PVC (SWR) , Cast Iron, AC, SWG soil waste and vent pipe of 75/110 mm bore including accessories set in cement mortar and removing rubbish from site as directed by Engineer-in-Charge complete all as specified and directed.
S&F of 110 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F of 75 mm PVC (SWR) drain pipe single socketed in any length with rubber ring joints fixed to walls complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) bend any radius with access door complete all as specified and directed.
S&F of 110 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) junction single (Single T) equal or unequal with access door jointing with solvent cement complete all as specified and directed.
S&F of 110 X 75 mm bore PVC (SWR) reducer including jointing with solvent cement complete all as specified and directed.
S&F of 75 mm bore PVC (SWR) vent cowl including jointing with solvent cement complete all as specified and directed.
S&F in repairs bathroom mirror cabinet PVC/Acrylic Medium size all as specified and directed by Engr-in-Charge. Make : Parryware/Polytuff/Commander/Cera
S&F in repairs Brass chromium plated shower rose with or without swivel joints 125 mm size including fixing to steel pipe or union complete all as specified and directed.
S&F in repair 15 mm bore PVC connection 450 mm long with two brass chromium plated brass nuts and PVC washers complete all as specified and directed.
S& F Brass CP Basin mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE.
S&F in repairs angle stop valve 15 mm bore, chromium plated, fancy type, with wall flange, screwed down, high pressure with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE.
S&F wall mixer 2 in 1 System-FLR with Provision for Overhead shower with 115 mm Long Bend pipe of make Jaquar or equivalent complete all as specified and directed. Make : Jaquar or equivalent as approved by GE.
S&F in repairs sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or includingfixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed.
S& F Stainless Steel Sink mixure, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for 15mm bore iron pipe and fixed complete all as specified and directed. Make : Jaquar or equivalent as approved by GE. Make : Jaquar or equivalent as approved by GE.
S&F in repairs kitchen plate rack made out of stainless steel 0.50 mm thick sheet with partitions and size of rack 800 x 250 x900 mm with shape and pattern as per sample kept in Sample room of GE Office complete all as specified and directed.
S&F in repair 15 mm bore chromium plated bib tap fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed all as specified and directed.
S&F in repairs brass chromium plated tubular towel rail of 20mm dia D' type 60cm long between flanges complete all as specified and as directed.
S&F in repairs sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repairs Soap dish, CP, fixed to plugs with chromium plated brass screws complete all as specified and as directed
S&F in repairs Grating doom 100mm dia all as specified and as directed.
S&F in repairs PVC low level flushing cistern 10 Ltr capacity, valveless syphonic action type complete with inlet, ball valve, float valve, bends brackets, rawl plug, brass screws handle etc complete having BIS description mark with IS-2731 with and including suitable size of MS brackets, plug, screw all as required incl taking down existing high level/low level flushing cistern any type disconnecting pipes and jointing with new one etc, and making good the floors/walls as per existing floor finish/wall finish including 32 mm bore PVC flush pipe and jointing with water closet of any type all as specified and directed. Make : Cera/Hindware/Parryware
S&F in repairs water closet (squatt pattern) of vitreous china squatting pan of pattern "ORRISA" pattern size 580 x 440 mm white with integral foot rests (excluding flushing cistern and flush pipe) including connection to trap and flushing pipe anti syphonic pipe etc complete including trap set in and including necessary lean cement concrete complete all as specified and directed. Make : Cera/Hindware/Parryware
S&F Vitreous China wash basin, flat back, size 600x480mm white, excluding taps, waste, chain and plug and rcelain stopper but including brackets complete all as specified and directed.Make : Cera/Hindware/Parryware
Taking up or down 15 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar (1:3) to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting exceeding 20cm girth complete all as specified and directed.
S&F of 15 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed,
S&F Refixing 15/20 mm old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed,
Taking up or down 20 mm bore old steel tubing and connections, including disconnection of fittings from tubing including cleaning for re-fixing or removal from site complete all as specified and directed.
S&F of 20 mm bore tubes medium grade galvanised with and incl all GI fitting (such as bends, elbows, Tees, connectors, short pieces, back nuts, unions, caps and plug etc ) and fixed complete to wall and ceiling or laid in/on floor complete all as specified and directed,
S&F in repairs 75 mm size PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sqm each and refixing in same opening after Resecuring or easing & adjusting complete all as specified.
Taking down chowkhats or frame not exc 1.50 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkhats or frame exc 1.50 and not exc 4 sqm each with shutter (without taking off shutters from the frame) complete all as specified and directed.
S&F 35 mm thick (batten thickness) second class hard wood , plain, framed panelled shutters (any number of panels), with panels of 12 mm thick timber flat on both sides (feather edged), or of 12mm thick veneered particle board medium density wood particle board with commercial face veneers complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F 35 mm thick (batten thickness) second class hard wood, glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc , divided into squares, with plain chamfered or rounded, mitred and without sash bars, edges of framing plain, chamfered or rounded with cut mitred beds for securing glass etc, supplied and fitted to chowkhats complete all as specified and directed. (Note :- The dimension of the various components or parts of shutters shall be as specified in clause 8.24 (a) of MES SSR 2009 Part I)
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles a PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; t both side Prelam PVC sheet used instead of Plaincolour PVC sheet. Stile and rails feathered at edges beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing all as specified and directed.
S&F Solid PVC Door Frame of size 50mm x 47mm made out of 5mm single side prelam PVC sheet used reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified.
S&F steel window with side hung shutter, including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified.
S&F steel ventilator with top hung shutter including hinges, steel peg stay, complete complete all as specified and directed.
S&F steel window or ventilator fixed type with glazing bar complete complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails all as specified and directed.
S&F 2nd class hardwood weather boarding, 25mm thick, wrought both sides, V-jointed to give 20mm laps and fixed complete all as specified and directed
S&F 12mm thick Plywood, grade BWP, type BB fixed with screws to timber frame work all as specified and directed.
S&F 9mm thick Veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces; fixed with screws to frame work all as specified and directed.
M&L for 18/19 block boards, grade 2 quality, interior grade, commercial type, fixed with screws to timber frame-work complete all as specified and directed
S&F Ist Class hard wood external teak wood lipping, 6 mm thick on exposed surface of prelaminated particle board fixed with nails complete all as specified and directed
M&L for second class hardwood plain fillets, square, rectangular or triangular in section, clean sawn, secured with nails or screws, sectional area exc 3 cm and n exc 6 sqm all as specified and directed.
S&F Mild steel pressed handles, 100mm oval type, stove enamelled black all as specified and directed.
S&F Mild steel barrel tower bolts 100mm, stove enamelled black, with bright bolt and fixed all as specified and directed.
S&F Butt hinges, heavy weight, cold rolled mild steel and fixed
S&F Hasp and staple, mild steel, wire type, stove enamelled black, including bolt to hinge plate and fixed with screws all as specified and directed.
S&F Mild steel sliding door bolts, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed
S&F Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 all as specified and directed.
S&F of continuous (piano) hinges mild steel bright finish or electro galvanised 30 mm width of flaps complete all as specified and directed.
S&F of 150 mm long aluminium, anodised, barrel tower bolt, of extruded section and fixed all as specified and directed.
S&F 150 mm size Aluminium handles, cast type, anodised and fixed all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
S&F in repair stainless steel wire cloth 0.36mm nominal dia if wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins/spring clips and providing and fixing new ones all as specified and directed.
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.
S&F 4 mm thick figured glass, pin head type and glazing with oil putty in square not exc 0.50 sqm in each pane complete all as specified and directed.
S&F mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars,barred iron doors, ladders, framed balusters, walk ways, railings and similar work confirming to Fe-410-0 or Fe 310-0 complete all as specified and directed.
S&F in repairs 25mm dia curtain rod (curtain rails), alumunium alloy, powder coated with and including decorattive knobs etc complete all as specified and directed.
M&L preparation of new steel surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L preparation of old steel surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L preparation of new wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L preparation of old wood or wood based surfaces of any description over 10 cm width or girth not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for dismantling of existing water closet after disconnectiing the flush pipe, demolition of entire floor upto bottom of sunken portion, removing debries cleaning the top of the RCC slab in sunken portion incl peripheral surfaces and plastered with 10mm thick cement & sand mortar (1:3) using WPC finished even and smooth without using extra cement cured properly and allowed to dry and applying two or more coats of epoxy resin/polymer modified cementatious coating like brush bond of Fosroc or equivalent both on floor and wall surfaces applied as per manufacturers instructions and plastering the treated surfaces (after testing)for water tightness) 15mm thick with CM 1:3 with WPC incl providing 20mm dia GI spout with 300 mm projection beyound outer face of wall complete all as specified and directed. Area of each WC/Toilet 0.90mx1.80m
Taking down carefully unserviceable copper/aluminium point wiring of any description including all fittings (switch , socket, switch socket combination, lamp holder, ceiling rose, regulator etc.) and making good disturbed surfaces of wall, floor etc. to match with existing finishes complete all as specified and as directed.
Dismantling and taking down unserviceable main switches, DBs including sub main wiring etc. any type / size and making good disturbed surfaces to match with the existing finishes complete all as specified and as directed.
Material and labour for point wiring with two runs of stranded copper conductor PVC insulated unsheathed 1.5 Sqmm FRLS cable with one single core continuous 1.5 Sqmm,FRLS copper cable for earth wire in and including PVC casing caping of suitable size as surface wiring including provision of mild steel terminal boxes as conceiled (concealed type in permanent bldg and surface PVC board in temporary bldg or as directed )with 3 mm thick laminated bakelite sheet cover ,for housing switches, socket outlet, regulator etc, complete all as specified and as directed for One light point controlled by one switch.
All as per Item No-119 but One fan/ Exhaust fan point controlled by one switch
All as per Item No-119 but One bell point controlled by one switch.
All as per Item No-119 but One 3 pin socket outlet 5 Amps on the same board.
All as per Item No-119 but One 3 pin socket outlet. 5 Amps on the independent. board
One 15 A socket outlet independent with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire.
Point wiring with 2.5 sq mm PVC cable and 1.5 sqmm cable as earth continuity wire in and including One single pole and neutral enclosure wih two pin and earth plug and socket with one MCB SP 20 amps for Geyser
Supply and fix Ceiling rose, 3 terminal, PVC / Polycarbonate insulated body in replacement of existing all as specified and as directed
Supply and fix switch piano flush type single pole one way 5 Amps complete all as specified and as directed
Supply and fix Bell push button 5 Amp, flush type complete all as specified and as directed
Supply and fix Bell, Ding Dong electric AC 230 Volts single pole complete all as specified and all as specified and as directed
M & L for switch socket combination 3 pin 5 Amps flush type (multi purpose ) complete all as specified and as directed.
M & L for switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and as directed.
S & F in replacement of lamp angle/batten holder Bakelite Pin/Retrofit type, in and including with 10 watt LED Lamp (B22) all as specified and as directed.
S&F LED Light fitting 1x9W Bulkhead luminaires including LED light driver connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED tube lights fitting, 4 feet long 1x 18W, 220V, AC decorative box type with holder including Removable poly cabonate LED tube light with inbuilt driver connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing building LED security light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including suitable size of GI bracke and clamps for wall fixing complete all as specified and directed.
S&F TPN DB with suitable for TPN MCB incomer, double door (IP-54), 4 Ways, built- in 200 Amps busbar for neutral link complete suitable for 415 Volts, AC, 50 Hz complete all as specified and as directed. Make - Legrand/Siemens/Schinder/Havells.
Supply and fix MCB, Tripple Pole & Neutral, 63 Amps, 415 volts, 50 Hz, 16kA complete all as specified and directed by Engr-in-Charge. Make - Legrand/Siemens/Schinder/Havells.
S&F Sheet Metal enclosure for SPN DBs, 8 Ways, Double Door, built in 200 Amps bus bar complete suitable for 240 Volts, AC, 50 Hz complete all as specified and as directed Make: L&T / Legrand /C&S/Havells
S&F MCBs, SPN, 240 volts, breaking capacity 10 KA, rating 40-63 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
S&F MCB, SP,240 volts, breaking capacity 10 KA, rating 6 to 32 amps, complete all as specified and as directed. Make: L&T / Legrand /C&S/Havells
M&L submain wiring with two single core PVC insulated, unsheathed, stranded copper conductor cable (FRLS), 1100 volts grade of size 06 Sqmm (nominal area) each and one single core 06.0 Sqmm (nominal area) as earth continuity conductor drawn into PVC casing capping complete all as specified and directed. NOTE: (i) Rates for PVC casing capping with accessories are deemed to be included in the unit rate.
Supply and Fixing/Install New Exhaust Fans Metal body AC single phase 230V, size of 230MM Sweep withprovn of louvers accessories and eletric connection and taling down old exhaust fan, depositing E/M store yard complete all as specified and as directedMake:-Havells Ventil Air - DB NEO / DB
24.Taking down Electric KWH meter and keep in safe custody and refixing the same as including necessary electric connection from main to KWH meter and KWH meter to out going distribution board all as specified and as directed.
S & F Electric water heater, storage type steel body wth copper inner tanland hating element upto 2 KW capacity 25 Ltrs complete with all accessories such as safety valve, thermostate, NRV, including taking down unserviceable Geyser and depositing to E/M store, complete all as specified and directed. connection pipe etc all as specified and as directed.
Earthing complete with galvanized mild steel earth plate electrode size 600x600x6mm thick buried directly in ground (Preferably in vertical position) earth pit not less than 2.25 meter below normal ground level with top edge of the earth plate not less 1.5 meter (BGL) connected to galvanized iron earth lead wire 4mm dia by means of bolts, nuts, check nut and washer of galvanized iron including PCC pit in RCC 1:2:4 type B-1, precast RCC cover with suitable handle, excavation and earth work in any type of soil, 20mm bore “medium grade” galvanized iron water tubing fixed with cast iron funnel and wire mesh and 15mm bore “light grade” galvanized iron protection pipe for earth lead wire upto 5m length, charcoal, common salt, complete all as shown in EP No 3 of SSR 2009 part-I, connected to test point complete, all as specified and as directed including testing on completion.
Material and labour for cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armored, electric power cables (heavy duty 1100 Volts grade with stranded aluminium conductor of size 25 Sqmm 3.5 Core, including glands, lugs, nut, bolts, washers as required at site, testing complete all as specified and directed.
Excavation in trenches/ foundation in soft/ loose soil not exc. 1.5 metre wide and n'exc. 1.50m deep for LT under ground cable/pole foundation and getting out including forming bottom surface to required level or slope, complete all as specified and directed by Engineer-in- Charge
Returning, filling in, including spreading , leveling , watering and well ramming in layer not exceeding 25cm each layer all as specified and as directed.
Removing excavated material not exceeding 50M and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Sand cushioning to underground cables provided with a layer of sand 8cm thick before laying the cable in trenches and 15cm thick after laying the cable in trenches complete all as specified and as directed.
M&L Sub class ‘B’bricks for covering to cable laid dry flat ,with width equal to the length of brick all as specified and as directed.
S & F Steel pipe glavanized light grade of 40 mm dia laid in trenches or under ground/floor or road of fixed with pole for protection of cable/ Earth sstrip including clams with bolts nuts and wasers complete all as specified and as directed.
Cutting through existing bituminous road /PCC/floor/approx size width 50cm X 60cm depth along cross section of the road for laying of GI tubing/RCC pipe for encasing of cable and repairing the road to match with the original finish, M&L complete all as specified and as directed.
Note: In case doubling/duplicancy of BOQ items , the lowest quoted rate shall be applicable for payment.
DEDUCTED AMOUNT OF SCHEDULE OF CREDIT
SANJAY SAW MILL
RAMESH GURUNG
RAJU TAMANG
G K SUTHAR
DEEP CHANDRA JOSHI
MS MAYA PRAKASH GOEL AND SONS
HEM RAJ GURUNG
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .