Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-AOC H NO 01 MADINA BAGH MEHJOOR NAGAR NEAR HOTEL RAFADA SRINAGAR 190015 J K | BUDGAM | JAMMU AND KASHMIR | 190015 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹9.6 L+₹2.6 L (37.3%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹10.0 L+₹3.0 L (43.0%)Rejected-Finance | L3 | Rejected-Finance Other than lowest |
Tender Value
Refer Docs
EMD Value
₹20,000
Closing Date
17 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ABHISHEK SHARMA
GARRISON ENGINEER (AF) THOISE, 19 FBSU, C/O 56 APO, PIN 937219
REPAIR/REPLACEMENT OF FLAME PROOF WIRING AND CONNECTED ITEMS AT AF STN THOISE
2020_MES_398229_1
GEAF/T-32/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
THOISE
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (AF) THOISE
₹20,000
Yes
27 Mar 2021
26 Nov 2020
19 Dec 2020
26 Nov 2020
17 Dec 2020
3 Dec 2020
60 days
Amount
Taking down carefully existing unserviceable flame proof aluminum point wiring of any description & in any position with and including existing conduit fixed on surface with and including existing junction boxes in between the point wiring complete, including making good the disturbed surface of walls, floors, ceiling etc to match with the existing surfaces complete all as specified and directed by Engr-in-charge. NOTE: (i) Old existing junction boxes obtained in serviceable condition from taking down of point wiring shall be re-used in the work. (ii) Taking down / replacement of existing fittings like switches/sockets / switch fuses / tube light fittings etc. if any, shall be measured and paid for separately under appropriate item of Schedule `A'
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in and including stove enameled black, rigid steel conduits of size not less than 20 mm dia (Medium grade) fixed on surface of walls/ceilings as directed with all accessories and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc complete all as specified and directed by Engr-in-charge. NOTE : (i) Old junction boxes retrieved in serviceable conditions shall be re-used in the work. However, additional junction boxes, if any required, for making new point wiring other than the quantity of junction boxes retrieved from taking down of point wiring, shall be measured and paid for separately as ‘’supply only’’ under appropriate item of Schedule `A' but fixing element of any type of junction boxes new or old is deemed to be included in the rates quoted by the contractor for the above item. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'. MAKE:- Copper Cable - Polycab, Steel Conduit - NIC
All as per item No 02 above but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 Amps Flame proof Switch and socket complete all as specified and directed by Engr-in-charge. MAKE :- Copper Cable - Polycab, Steel Conduit - NIC
Material and labour for flame proof point wiring for one light point or one socket point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade in existing conduit fixed on surface of walls/ceilings as directed and using 1.5 Sqmm (nominal area) stranded copper conductor single core FRLS, PVC insulated & unsheathed cable as in earth wire connected to common earth dolly / fittings etc. complete all as specified and directed NOTE : (i) Point wiring shall be executed with using existing conduits and junction boxes but contractor’s quoted rates for the above item is deemed to include the cost of fixing the existing conduits and junction boxes in position properly as per site requirement and as directed by the Engineer-in-Charge. (ii) Wiring shall be terminated and connected to the relevant switch / controlling switch gear and relevant fittings / sockets all as directed and controlling switch / fittings shall be measured and paid for separately under appropriate item of Schedule `A'. MAKE :- Copper cable - Polycab
All as per item No 4 above but point wiring for 2 light points controlled by one switch complete all as specified and directed by Engr-in-charge. Make :- Copper cable - Polycab
All as per item No 04 above but point wiring with using 2.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable for 16 A Flame proof Switch and socket complete all as specified and directed by Engr-in-charge. Make :- Copper cable - Polycab
Taking down carefully u/s worn out wires of sub main wiring from existing conduit and M&L for drawing new two single core PVC insulated, FRLS, stranded copper conductor cable of size 4 Sqmm for sub main wiring, along with one run of 2.5 Sqmm PVC insulated, FRLS, Stranded copper conductor cable for earth continuity conductor all as specified and directed by Engineer-in-Charge. Make :- Copper cable -Polycab
Disconnecting and taking down carefully flame proof, weather proof, toggle type switches and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Disconnecting and taking down carefully flame proof DB’s of any size/way and making good the disturbed surfaces all as specified and directed by Engineer-in-Charge.
Supplying & fixing for flame proof push button 10 Amps in LM 6 metal enclosures, conforming to cat part No PBS / OA /1010-1A of make Sudhir complete all as specified & directed by Engineer-in-Charge.
Supplying & fixing for flame proof emergency stop push button LM 6 metal enclosures, conforming to cat part No PBS / OA /1010 of make Sudhir complete all as specified & directed by Engineer-in-Charge.
Supply and Fixing flame proof 16A Single pole ON-OFF /rotary type switch of any description any capacity or make complete all as specified & directed by Eng-in-charge. Make: Cat Part No RI/OA/1010-2A of Sudhir
Supplying & Fixing flameproof switch fuse unit in LM-06 metal enclosures, with HRC fuse double pole 16 Amps, Single Phase 240 volts complete all as specified and directed by Engr-in-charge. Make/Model – Sudhir cat part No. SF/A/1011.
Supplying & fixing flame proof, switch socket & plug combined made of aluminum alloy LM-6 having 2 pole + earth suitable for 250 volts supply and current rating of 16 Amps complete all as specified & directed by Engineer-in-Charge. Make/Model – Sudhir cat part No. SS/OA/1010 -1
Supplying & Fixing flameproof distribution board 8 way single pole & neutral in LM-6 metal enclosures with and including supplying & fixing 01 No MCBs single pole and neutral 40 Amps & 06 Nos MCB single pole 16 Amps `C’ series complete all as specified and directed by Engr-in-charge. Make : Cat part no MCDB-186 of Sudhir.
Supplying & Fixing flame proof point weather proof LED tube light fitting box type with 1x20 W led tube rod including connecting electrically to ceiling using flexible 3 core PVC insulated over all sheated with flexible copper conductor of size .75 Sqmm complete all as specified and directed by Engr-in-charge. Make : Havells, Bajaj, CG
Disconnecting & taking down carefully, existing unserviceable flame proof, weather proof, fluorescent tube light fitting (1 x 40 watt 2 x 40 watt), well glass of any description and in any position all as specified & directed by Engineer-in-Charge
Supplying & fixing flame proof fluorescent tube light fittings 1 x 36/40 watt as per IS : 2148 / 1981 & 2206 (Part-I )1984, Temperature class T-4, & made of cast aluminum alloy LM-6 having inside & outside light grey powder coating shade No 631 as per IS: 5 & one No internal earthing terminal and 02 Nos external earthings of screw of M6- size with 02 Nos plane washers heat resistant glass of make Borosil complete with starter, holder, choke etc & pre-wired including reflectors and wire guards and including one No fluorescent tube 40 watt, fitting fix to wall/ceiling with using old existing fixing arrangements all as specified and directed by Engineer-in-Charge. Make : Sudhir Cat Part No FF/OA/1271/401.
All as per item No 19 above but Supplying & fixing flame proof fluorescent tube light fittings 2 x 36/40 watt with 02 Nos fluorescent tubes complete all as specified and directed by Engr-in-charge Make :- SUDHIR cat part No. – FF/0A/1271/402
Disconnecting and taking down and Supplying and fixing on distribution board, single pole (SP) MCB 6 to 20 Amps, 240 volts, 50 Hz, AC made from molded self extinguishing thermostat plastic and suitable for ‘ C ‘ curve, 10 KA breaking capacity complete conforming to IS : 8828 of 1996 complete all as specified and directed by Engr-in-charge Make : MDS legrand
All as per item No 21 but Supplying & fixing MCB of double pole & current rating 6 Amps to 32 Amps complete all as specified and directed by Engr-in-charge. Make: MDS legrand
All as per item No 21 but supplying & fixing MCB of four pole & current rating 40 Amps complete all as specified and directed by Engr-in-charge. Make: MDS legrand
Replacement of unservicable LED tube light fitting 18 watt incl. LED tube complete with all accessories internally pre- wired and incl.connecting up with twin core twisted flexible copper conductor cable of 1.5 Sqmm, complete all as specified and directed by Engr-in-charge. Make: Cat Part No.LHEXCEPNUNIW020 of Hevells equivallent of Wipro/ Philips/Bajaj
Replacement of unservicable LED new adore of 15W B22 CDL ball lamp complete all as specified and directed by Engr-in-charge. Make: Cat Part No.LHLDEREEMK8X015 of Hevells or equivallent of Wipro/ Philips./Bajaj .
Replacement of unservicable LED new adore of 07W B22 CDL ball lamp complete all as specified and directed by Engr-in-charge. Make: Cat Part No.LHLDERUEML8X007 of Hevells or equivallent of Wipro/ Philips./Bajaj .
Replacement of old unserviceable sub main wiring for circuit/ submain wiring alongwith earth wire with two run of 6.0 sqmm of , PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100Volts grade and one run of 4 sqmm, PVC insulated copper conductor, single core cable, multi stranded, ISI marked, 1100 Volts grade as earth wire connected to earth terminal, and including concealed 25 mm dia PVC conduit 2 mm thick with all fittings, ISI marked, incl. cutting chases & making good disturbed surfaces of walls, floors etc to match with existing surface complete all as specified and directed by Engr-in-charge.
Replacement of unservicable switch piano type 5 A flush button single pole one way complete all as specified and directed by Engr-in-charge
Replacement of unservicable switch socket combination,outlet, 2 pin 5 Amp/ 3 pin 5 Amp flush type multipurpose complete all as specified and directed by Engr-in-charge
Replacement of unservicable switch socket outlet suitable for inserting 2 pin 5 Amp/ 3 pin 15 Amp plug top flush type multipurpose complete all as specified and directed by Engr-in-charge
Supply and fixing flexible metal conduit (Bend, Elbow, Tee) flame proof complete all as specified & directed by Engr-in-charge. Make: Bajaj/SUDHIR
Supply and fixing connecting metal conduit flame proof complete all as specified & directed by Engr-in-charge. Make:- Bajaj /SUDHIR
S&F in replacement of porcelain lamp with complete fitting suitable for HPMV/ HPSV lamps complete all as specified and directed by Engr-in- Charge. Make - Bajaj/ Sudhir/ philips
S&F in repair open construction HPSV/MH Ballast copper wound 150 watt suitable for 150 watt HPSV/MH fitting complete all as specified and directed by Engr-in-charge. Make :- Bajaj Catpart no - BJOS150 SV/MH or equivalent others make as specified.
S&F in repair Igniter suitable for HPSV/ MH lamp fitting of cap 70/ 150/ 250 watt complete all as specified and directed by Engr-in-charge. Make :- Bajaj Cat part No - BJIGN HPSV1 or equivalent others make as specified.
national engineering
KONCHOK TSEWANG
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .