Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.6 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹21.8 L+₹88,313.60 (4.22%)Rejected-Finance | L2 | Rejected-Finance BEING NOT LOWEST | |
| 3 | L3₹24.3 L+₹3.4 L (16.1%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | L3 | Rejected-Finance BEING NOT LOWEST | |
| 4 | L4₹27.3 L+₹6.4 L (30.4%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | L4 | Rejected-Finance BEING NOT LOWEST | |
| 5 | L5₹32.9 L+₹12.0 L (57.5%)Rejected-Finance NO 9 BYRAVESHWARA INDUSTRIAL ESTATE ANDRAHALLI MAIN ROAD NEAR PEENYA 2ND STAGE BENGALURU 560 091 | BENGALURU URBAN | KARNATAKA | 560091 | L5 | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹44.0 L
EMD Value
₹88,000
Closing Date
22 Sept 2021, 6:00 pmClosed
ARJUN PATRO,IDSE
GE U ELECTRIC SUPPLY,DELHI CANTT
REPLACEMENT OF DAMAGEDLOW INSULATION HTLT CABLES REPLACEMENT OF DAMAGED LT STREET LIGHT POLE, PAINTING, REPLACEMENT OF JUNCTION BOXES, LT PANELS SWITCH GEAR ACCESSORIES IN THE POCKET NO 25 OF GE U ELECT SUPPLY DELHI CANTT10
2021_MES_470458_1
GE ELECT/D-77/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE U ELECTRIC SUPPLY
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE U ELECTRIC SUPPLY
₹88,000
Yes
14 Oct 2021
26 Aug 2021
29 Sept 2021
27 Aug 2021
22 Sept 2021
10 Sept 2021
Amount
Supply and fixing in replacement of galvanised iron strip 32 X 6 mm for additional earthing lead beyond 7.5 meter.
M & L for cutting and removing grass, vegetation bushes etc from surrounding of installation/LT Panel/Four Pole structure/Sub Stations and removing all rubbish to a distance not exceeding 50 m as directed.
Supply only fuse wire of rating 20Amps/40Amps/60 Amps
M & L for two coats of Aluminium paint on steel surfaces/wire over a coat of aluminium red oxide primer including preparation of surfaces complete all as specified.
Material and labour for PCC 1:3:6 type C-2, (using 40 mm graded crushed stone aggregate) for foundation, filling and mass concret etc complete all as specified and directed including demolition of old unserviceable PCC.
S&F in replacement Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165 complete all as specified and as directed
M&L Brick work with sub-class 'B' bricks, straight or curved on plane exc 6 m mean radius, built in cement mortar 1:6 complete as specified and directed including demolition of old unserviceable brick work.
M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) finished fair and even without using extra cement complete all as specified and directed including preparation of surface.
Demolition of path /concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) .complete all as specified and as directed.
Material and labour for coarse aggregate filling using stone gravels, rounded, of size n exc. 40 mm , in the area covered by four pole structures complete all as specified and directed.
M & L for PCC 1:3:6 type B0 using 12.5 mm graded stone aggregate for coping of pole all as directed.
M&L for PCC 1:4:8 type D2 using 40 mm graded stone aggregate for pole foundation all as specified and directed.
M&L for re-painting of LT Steel tubular poles of any sizes with apply of 2 coats of aluminium paint including rubbing with wire brush/emery paper & writing pole Nos in appropriate size of letters including making yellow and black strips upto height of 1.5 mtr above from ground level complete all as specified and directed.
Supply & fixing in replacement of SMC Junction box for street light having side hinged, outside dimention 333x233x120mm and inside dimention 300x200x105mm including 4 Nos aluminium bus bar of 40 Amps rating and 1 No 5 A MCB SP connecting of existing LT power cable complete all as directed
Supply and fixing in replacement of Automatic Light Timer switch with Nature switch Cat No. SWADEEP-02EC12KW3P, infra ray sensor with pre sawn switching off timer, 4-8 hrs, of Maximum load capacity of 4KW per phase. Degree of protection conforms to IP 65 complete all as specified and directed.
Supply & fixing of quick sensor QS-301 water proof sensor 220V auto day/Night ON and OFF photo cell , LDR Sensor of capacity 6A for fixing in places of defective timers of street light control panels complete all as specified and directed.
Supply and fixing in replacement MCCB 4 pole 100 Amps, thermo magnetic releases, rupturing capacity 35 KA, with spreader link on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified & directed as per site requirement
Supply and fixing in replacement MCCB 4 pole 160 Amps thermo magnetic releases rupturing capacity 35 KA on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified and directed as per site requirement
Supply and fixing in replacement MCCB 4 pole 200 Amps thermo magnetic releases rupturing capacity 35 KAIcs=100% Icu with spreader link on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified & directed as per site requirement
Supply and fixing in replacement MCCB 4 pole 250 Amps Microprocessor based type rupturing capacity 25 KA based adjustable type type on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified and directed as per site requirement
Supply and fixing in replacement MCCB 4 pole 320 Amps Microprocessor based type adjustable type rupturing capacity 36 KA on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified and directed as per site requirement
Supply and fixing in replacement MCCB 4 pole 400 Amps Microprocessor based type adjustable type rupturing capacity 36 KA on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified and directed as per site requirement
Supply and fixing in replacementMCCB 4 pole 630 Amps Microprocessor based type adjustable type rupturing capacity 36 KA on LT panel/feeder pillar including taking down existing unserviceable MCCB complete all as specified and directed as per site requirement
Supply and making in replacement new LT 1100 V end termination with suitable size of aluminium lugs duly crimped for LT 3 ½ core armoured aluminium conductor cable after isolating supply to transformer/LT panel and disconnecting brunt/fault cable from the bunch of cables in trenches, galleries, removing cable loop, opening the cable blank and connecting back after end terminals, testing and commissioning for following sizes all as specified and as directed
Cable Size 35 Sqmm to 120 Sqmm ,3.5 mm core
Cable Size 185 Sqmm to 240 Sqmm 3.5 mm core
Cable Size 300 Sqmm to 500 Sqmm 3.5 mm core
Taking down the LT air circuit breakers of various capacities from 800 amps to 1250 amps for repairs, servicing comprising the following and refixing the same, re-orientation and labour for taking down the defective parts and refixing the same spare parts all as specified and directed (a) Checking/repair of mechanical system of ACB. (b) Checking/repair of the manual closing/tripping of breaker.
Supply and fix in repalcement closing coil of ACB from 800 to 1250 Amps complete all as specified and as directed
Supply and fix in repalcement trilping coil of ACB from 800 to 1250 Amps complete all as specified and as directed
Supply and fix in repalcement Spring charging motor complete all as specified and as directed
Supply and fix in repalcement Male & female contact complete all as specified and as directed
Supply and fix in repalcement Master triping relay complete all as specified and as directed
Supplying, laying, jointing testing and connecting in replacement XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with multistranded aluminum conductors, 11 KV grade, IS 7098 marked, suitable for HT 11 KV(E) system, laid in trenches fixed to pole, including jointing & testing complete all as specified and directed of following sizes:- Note :- Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
150 sqmm 3 core.
185 sqmm 3 core
240 sqmm 3 core
300 sqmm 3 core
Laying onlyLT UG Cable in replacement LT cable of PVC sheathed XLPE cable armoured aluminium conductor 1100 V graded of following sizes after taking out/down old existing unserviceable from trenches / ducts/ road crossing and poles complete all as specified and directed. Notes:- Cables shall be issued free for fixing only under Schedule 'B'.
2/4 core,10 sqmm to 3.5/4 core 25 sqmm,
3.5 core, 35 sqmm to 3.5x 50 sqmm
3.5 core,70 sqmm to 3.5x 95 sqmm
3.5 core,120 sqmm to 3.5x 185 sqmm
3.5 core,240 sqmm to 3.5x 400 sqmm
Excavation in trenches in soft and loose soil n.exc 1.5 mtr wide and n.exc. 1.5 mtr depth for laying and taking out of electric power cable and getting out all as specified and directed by engineer –in-charge.
Returning filling in including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all as specified and directed.
Removing excavated material not exceeding 50 mtr away and depositing where directed at a level n. exc 1.5 mtr above the starting point .
Material & labour for river washed and screened dry sand for filling under and above the under ground cable for cushioning of cables etc.complete all as specified and directed by engr –in-charge, Note : Measurement shall be taken after punning down.
Supplying & laying in replacement un-reinforced precast concrete cable cover, class HV, type 1, flat size 300mmx 180mm x 40mm.
Laying only old HT cable cover obtained from excavation complete all as directed.
S&Laying in replacement sub class B bricks having minimum compressive strenth 75 Kg/sqcm ( 250x115x75mm) laid in trenches for cable protection etc complete all as directed by Engineer-in-Charge.
All as per Srl item No 39 here in before but using old bricks obtain under item No 33 here in before.
Material and Labour only for repairing and rectification of faults in 16 / 32 mtr High mast lights by checking the control panel Trailing Cables, timers. contactors and replacing the defective electrical parts, Servicing and greasing to the winch gear wheel mechanisum for electrical and manual operation of the carrier along with replacement of dog clamps of the wire rope and replacment of the existing old unserviceable light fittings with controll gears with new LED light fitiings complete and fixing of the control panel for desired operation all as specified anddirected by the Eng-in-Charge Note :(I) Necessary Digital timers /Power contactors and LED light Fittings shall be measured under Relevant Items. (II) Necessary arrangements for Safety and T&P repairs shall be under taken by contractor
Supply and fixing of new generation energy saving& enviroment friendly aluminium pressure die cast high power LED flood light luminare of wattage 150 Watts of IP66,class I portection integral driver operation at 170-270VAC 50Hz supply inclding , brackets for fixing on the pole/buildings/walls complete all as specified and directed.
Supply & replace in replacement deterioted twin core PVC aluminum PVC sheathed and insulated twin core 6 sq mm stranded aluminum conductor wire from light fitting to loop-in loop out box by taking down the perished burnt wiring.
Supplying, Errection & Fixing Steel Tubular swan neck pole ,(09 metres long) complete with cast iron base plate all as specified in IS including the followings:- (a) Excavation in post holes in any types of soil, returning filling, well ramming and disposal of surplus soil to a distance not exceeding 50 m from the starting points. (b) Providing PCC (1: 4:8) type D-2 using 40 mm graded stone aggregate as in foundations up to ground level all as specified and directed. (c) Providing PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in foundation including necessary form work for plinth block/collar above GL all as specified and directed. (d) Providing PCC (1:2:4) type B-2 using 20 mm graded stone aggregate as in coping including necessary form work all as specified and directed. (e) Painting of Poles with one coat of red oxide primer and one coat of aluminum paint before fixing and one coat of aluminum paint after fixing. The complete embedded portion shall be painted with two coats of black bituminus paint.
Supply and fixing LED street light fitting 90 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete
Supply and fixing LED street light fitting 120 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistantcomplete with driver, lamp bracket with impactand corrosion resistant including thermalmanagement in multiple optics complete withIP 65/66 protection complete
Cutting of road /Hard standing to a size of 30 cm in width and not exceeding 90cm in depth for laying of protection pipe /cable including spreading, leveling, watering and well ramming in layers and providing PCC in 1:2:4 type B1 using 20mm graded stone aggregate, for the top 100mm layer, complete all as specified and directed.
Supply and lay GI pipe light grade in replacement as cable protection laid on trench/floor, fixed on pole/wall etc of following sizes all as specified of size :-
150 mm dia
100 mm dia
80 mm dia
Earthing complete with galvanized steel earth plate electrode of size 60cmx60cmx6 mm thick, buried directly in ground (earth pit not less than 2.10 m below normal ground level) with top edge of earth plate not less than 1.5m below normal ground level, connected to galvanized iron strip 32 x 6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel as shown in electrical plate No 3 of SSR Part I 2009 , connected to earth test point and the equipment on the other nuts and washers of galvanised ironside complete all as specified, including testing and commissioning complete all as directed. Note : (a) The unit rates quoted against this item shall be deemed to include the cost of excavation and earth work in any type of soil, common salt & charcoal dust in alternate layers, PCC 1:3:6 as in pit, precast RCC 1:2:4 type B-1 with necessary reinforcement as in cover & frame for pit, funnel, watering pipe 20 mm bore GI pipe light grade, protection pipe 40 mm bore GI pipe medium grade etc. (b) The quoted rates shall also deemed to include the cost of earth test point and earth strip/GI lead wire and protection pipe upto 7.5 meter beyond the earth plates electrode.
NOTE :-(i)contractor should provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Eng-in-charge.
M/s JAIMAA ASSOCIATES
MV Engineers And Contractors
mayur enterprises
Vijay Electricals
Buddham Builders
DS CONSTRUCTION
Ridhi engineers and builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .