Tender Value
₹5.2 Cr
EMD Value
₹10.5 L
Closing Date
17 Apr 2026, 3:30 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
DY. CSTE
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or V whichever less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
(a)The tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or One similar work each costing not less than the amount equal to 60% of advertised value of the tender. (b) (i)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note: for b (i) separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. (b) (ii)In such cases, what constitutes a component in a composite work shall be clearly pre-defined with estimated tender cost of it, as part of the tender documents without any ambiguity. (b) (iii) To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contract or through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarised, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows: The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract. Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered atleast 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Similar Nature of work:- Any RRI/PI/EI/MACLS Supply, installation, testing, commissioning signaling work"OR"Any RRI/PI/EI/MACLS Alterations signaling work"OR"Any CTC/TMS work".
2 conditions
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
I/We have visited the works site and I/We am/are aware of the site conditions.
Dy. CSTE (GSU) JP Div.: Signaling work in connection with Provision of one longer loop line with PF and one additional line with PF at Dahar Ka Balaji of Jaipur division.
GSU-SnT-JP-2026-27-02
GSU-SnT-JP-2026-27-02
Open
Works - General
12 Months
Jaipur, Rajasthan
₹0
₹10.5 L
17 Apr 2026
25 Mar 2026
3 Apr 2026
149 items across 1 schedule · ₹3,61,90,171.76 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply of work station note book / tablet as per Technical Specifications. It also includes supply of Laser Printer (Only branded). The workstation should be capable of reconfiguring the system in case of any alteration in yard interlocking in future. Technical Specifications should be attached with the tender document by Tendering a u t h o r i t y . Inspection: Consignee Inspection charges: None Payment terms: 100% after supply | Station 1.00 | — | 1,04,575.4 | 1,04,575.4 |
| 2 | Design, preparation & supply of drawings in computer print copies and original tracing in AUTO CAD FORMAT for Electronic Interlocking at each station. After completion of the work, the completion drawings incorporating completion details are to be supplied as per Technical Specifications given in tender document (upto 6 Line). The technical specifications are as per ANNEXURE-01010100 of SOR. Inspection: Consignee Inspection charges: None Payment terms: 100% after execution | Station 1.00 | — | 2,11,776.71 | 2,11,776.71 |
| 3 | Preparation of SWR literature in English along with associated mid-section interlocked gate with all corrections as per approved SWRD & approved SIP. For these all-technical corrections, editing, grammatical correction etc. are to be carried out and one rough print to be given to railways for approval before printing, as required for final processing of CRS sanction. This also includes preparation of maintenance cards in format provided by Rly. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Station 1.00 | — | 4,330.94 | 4,330.94 |
| 4 | Translation of Station Working Rules from English to Hindi and framing out in DIGLOT form (or similar software) as per extant Rly practice. The required SWR in English will be provided by the contractor and has been covered separately in item no. 01011800 of Chapter 1 of SOR. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Station 1.00 | — | 5,389.49 | 5,389.49 |
| 5 | Making photocopies & binding of the SWR literature in English/Hindi/Diglot form as per Railway practice. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Set 6.00 | — | 214.85 | 1,289.1 |
| 6 | Supply of maintainer's furniture of Godrej make or superior and each set consist of (i) executive revolving bearing series low back-floating chair with normal arms cushioned chair-01 Nos. (ii) Executive table size 1650x900x728 mm with 3 drawers one side locker- 01 no. (iii) visitor chair seat & back cushion with high density foam with plastic PVC handle capsule type painted back-03 nos. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Set 2.00 | — | 27,664.71 | 55,329.42 |
| 7 | Designing and Plotting of Signalling Interlocking Plan (SIP) in AUTOCAD. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Per SIP 1.00 | — | 33,772.62 | 33,772.62 |
| 8 | Design of circuits in connection with preparation of wiring diagrams as per approved Signalling Plan and submission of indoor as well as outdoor completion documents. It includes Route Section Plan (RSP), Selection Table (ST), Locking Table (LT) and Control Panel Diagram (CPD)/VDU Diagram. Two copies of prints with soft copy will be submitted to Railway for checking. If alterations are suggested/proposed by Railways then again two copies of prints will be submitted for advance approval after carrying out all the alterations as suggested/proposed by the Railways. Tracings will be submitted for all the diagrams mentioned above for the purpose of approval by Railway prior to commissioning of station. All drawings will be prepared in CAD. The wiring diagrams will consist relay rack analysis, relay contact analysis, fuse details. Tag block analysis etc. A separate CD/Pen drive will be submitted to Railway for each station along with original tracings. It also includes preparation and supply of laminated one set of all completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will be submitted for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection Table, Locking Table, Contact Analysis, Fuse and Tag Block Analysis of Relay Rack and CT Rack, Control Cum Indication Panel/VDU diagram, Power Panel Diagram, Track Circuit Plan, Rack Erection Plan and Junction Box details etc. Note: Total cost of design and completion documents for a station/yard will be calculated on basis of total possible movements/routes as per Selection Table (ST). Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Per Route 30.00 | — | 4,999.24 | 1,49,977.2 |
| 9 | Preparation and supply of laminated one set of all the completion plans including circuit diagrams and indoor as well as outdoor completion documents on standard 75-micron polyester film for station in Auto CAD. 6 (Six) sets xerox copies will also be provided for each of the documents mentioned below: Cable Route Plan, Cable Core Chart, Location details plan for all the locations, Cable termination details, Signalling Plan, SWR Diagram, Wiring Diagrams, Selection table, Locking table, Contact analysis, Fuse and Tag Block analysis of Relay Rack, CT rack, Control cum Indication Panel/VDU Diagram, Power Panel Diagram, Track circuit plan, rack erection plan and Junction Box details etc. Inspection: Consignee Inspection charges: None Payment terms:100% after execution. | Sheet 300.00 | — | 193.85 | 58,155 |
| 10 | For Supply of Modular power supply arrangement. Payment Terms: 100% after Supply | Set 3.00 | — | 2,18,289.6 | 6,54,868.8 |
| 11 | For Installation of Modular power supply arrangement. Payment Terms: 100% after Commissioning | Set 3.00 | — | 54,572.4 | 1,63,717.2 |
| 12 | Supply of Failure Analysis System (FAS) as per Technical Specifications. The specification of FAS should be got approved from the Engineer in charge before supply. Note: The Specification of FAS shall be as per technical specification given in contract Agreement or higher version as approved by Engineer In-Charge. (Technical specification shall be provided in tender documents.) Inspection: Consignee Inspection charges: Borne by Railways Payment terms:100% after supply | Numbers 1.00 | — | 1,97,325.1 | 1,97,325.1 |
| 13 | Relay fail safe electronic time delay device with fixed timing (0 -120) seconds and conforming to RDSO Specn.No.IRS:S-61/2000 with Amnd.1 or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. The interlocking code for this unit shall be "AFGKY". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 10.00 | — | 2,210.43 | 22,104.3 |
| 14 | Relay fail safe electronic time delay device with fixed timing (0 @45<41@ seconds and conforming to RDSO Specn.No.IRS:S-61/2000 with Amnd.1 or latest mounted on Q-series relay base & covered complete with connectors, retaining clip etc. The interlocking code for this unit shall be "AFHKY". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 10.00 | — | 2,520.02 | 25,200.2 |
| 15 | Fail safe electronic flasher device as per RDSO Spec No. RDSO/SPN/173/ 2002 Amnd.2 or latest. Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 5.00 | — | 9,940.91 | 49,704.55 |
| 16 | Q-Series Neutral Line Relay (QN1 Type), 12F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDE". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 50.00 | — | 4,746.07 | 2,37,303.5 |
| 17 | Q-Series Neutral Line Relay (QN1 Type), 8F/8B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS- 930 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABCDF". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 140.00 | — | 4,560.51 | 6,38,471.4 |
| 18 | Q-Series Twin Neutral Line Relay (QNN1 Type), 6F/2B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACDEK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 40.00 | — | 5,999.85 | 2,39,994 |
| 19 | Q-Series Twin Neutral Line Relay (QNN1 Type), 4F/4B, 24V DC complete with plug board (base plate), connectors and retaining clips etc and conforming to BRS-960 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ACEHJ". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 40.00 | — | 4,739.38 | 1,89,575.2 |
| 20 | Q-Series Magnetically Latched Neutral Line Relay (QL1 Type), 11F/4B,24V DC complete with plug board (base plate), connectors and retaining clips and conforming to BRS-935A and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABDEG". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 50.00 | — | 6,861.7 | 3,43,085 |
| 21 | Q-Series Neutral Line Relay (Style QN1K), 1000 Ohm, 6F/6B,24V DC complete with plugboard (base plate), connectors and retaining clips etc and conforming to BRS:930 & RDSO letter no STs/E/Relays/UEA/PI dated 30.05.97 Annexure I and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "BDEKX". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 50.00 | — | 4,969.03 | 2,48,451.5 |
| 22 | Q-Series LED ECR (Universal Type i.e. QECX-61), 4F/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS:941A STS/E/RELAYS/AC LIT LED SIGNAL/09- 2002, Amdt.-1 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "ABDHK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 100.00 | — | 5,997.68 | 5,99,768 |
| 23 | Track Relay QBAT, AC immunized, 2F-2B contacts, 9 ohms. Complete with plug board, retaining clip & connectors as per RDSO/SPN/84 Ver 2.0 or latest. The interlocking code for this unit shall be "ABEJX". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 40.00 | — | 8,520.78 | 3,40,831.2 |
| 24 | Q-Series Line Relay (QNA1 Type), AC immunized, 8F/8B, 24V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDGH". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 116.00 | — | 4,710.1 | 5,46,371.6 |
| 25 | Q-Series Line Relay (QNA1 Type), AC immunized, 12F/4B, 24V DC along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-931A and RDSO Specn.No.IRS:S@45"44@ S-23 and S-60 or latest. The interlocking code for this unit shall be "ABDFH". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 50.00 | — | 4,579.92 | 2,28,996 |
| 26 | Supply of QNNA1, AC immunized relay 24V DC, 4F-4B/6F-2B contacts, along with plug board, retaining clip and connectors. Conforming to BRS: 960, IRS: S60, IRS: S34 & IRS: S23. (No of each configuration will be decided by Engineer In-charge). Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 40.00 | — | 6,039.6 | 2,41,584 |
| 27 | Q-Series Track Relay (QTA2 Type), AC immunized, 9 Ohms, 2F/1B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS:939A & 966(Appendix F2) or latest. The interlocking code for this unit shall be "FGHKX". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 30.00 | — | 4,494.71 | 1,34,841.3 |
| 28 | Q-Series Neutral Line Relay (QSPA1 Type), 24V DC,8F/4B along with plug board (base plate), connectors, retaining clips etc and conforming to BRS-933A and RDSO Specn.No.IRS:S@45"44@ S-23 & S 60 or latest. The interlocking code for this unit shall be "ABDEJ". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 50.00 | — | 6,271.77 | 3,13,588.5 |
| 29 | Contactor Unit (QBCA1 Type), 24 V DC, 2HF/4B complete with plug board (base plate), connectors, retaining clips etc and conforming to BRS- 943 and RDSO Specn.No.IRS:S-34 & S-23 or latest. The interlocking code for this unit shall be "BCEJK". Inspection: - RDSO Inspection charges: - Borne by Railways Payment Terms: - 100% after supply. | Numbers 70.00 | — | 8,520.78 | 5,96,454.6 |
| 30 | Key Lock Checking Relay (KLCR) working on 24V DC, AC Immunized with different ward combinations and contact configuration 4F/4B with 2 extra ward plates and with case, RDSO spec no. RDSO/SPN/219/2016 ver 1.0 or latest, confirming to IRS S-23, S-34 & S@45<44@ IRS S:46. Inspection: - Consignee. Inspection charges: - None. Payment Terms: - 100% after supply. | Numbers 15.00 | — | 11,361.04 | 1,70,415.6 |
| 31 | Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn.No.IRS:S- 76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Kilometre 2.00 | — | 6,996.26 | 13,992.52 |
| 32 | Supply of 1 x 6 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 84 conductor each dia 0.30 +/- 0.01 with insulation thickness of 0.8 mm and nominal conductor resistance of 3.3 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% on Supply | Metre 300.00 | — | 43.77 | 13,131 |
| 33 | Supply of 1 x 10 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 140 conductor each dia 0.30 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.91 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Metre 300.00 | — | 69.24 | 20,772 |
| 34 | Supply of 1 x 16 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 127 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board.Inspection Charges: (i)Borne by Railways(ii) NonePayment Terms: 100% on Supply | Metre 300.00 | — | 119.69 | 35,907 |
| 35 | Supply of 1 x 25 Sqmm (Red/Black) multi strand copper power wire as per IS:694:2010 or latest, 197 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.78 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Metre 300.00 | — | 186.89 | 56,067 |
| 36 | Supply of 1 x 35 Sqmm (Red/Black/Green) multi strand copper power wire as per IS:694:2010 or latest, 277 conductor each dia 0.40 +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn.No.IRS:S-76/89(Amnd.3) or latest. Colour of the wire which is required will be specified by the Engineer incharge. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Metre 300.00 | — | 212.94 | 63,882 |
| 37 | Supply of Cable Termination (CT) racks as per Drg. No. CSTE/S&T/SOR/02 complete along with fitting arrangements and also with arrangement for fixing four 8-way terminal strips/ Screw less terminals/ ARA terminals on each row having 16 such rows. Supply of 8 way terminal strips/ Screw less terminals / ARA terminals not covered under this item. Cable termination rack shall be Powder Coated. Inspection: (i) RITES if value of item in work more than 10 lakhs (ii) Consignee if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 2.00 | — | 27,358.46 | 54,716.92 |
| 38 | Installation of Cable Termination Racks assembly complete including wall supports, scaffolding and suitable grouting arrangements with installation of 8 way/ARA terminals /Screw less connectors, Tag blocks & other necessary accessories etc. The work shall be done as per approved plan, extant practice on NWR & the instruction of Rly engineer at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on Commissioning. | Numbers 2.00 | — | 10,454.95 | 20,909.9 |
| 39 | Supply of ARA Terminal Block (M-6) made of PBT/Poly Carbonate as per RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest and RDSO Drg. No. SA-23741A (Alt. 4) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers 2000.00 | — | 105.2 | 2,10,400 |
| 40 | Supply of Cartridge Fuse Block made of PBT and as per RDSO Drg. No. SA-23748 (Alt. 4) or latest and RDSO Specn.No.IRS:S-75/2006 (Rev.2) or latest. Inspection: RDSO. Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers 1000.00 | — | 184.11 | 1,84,110 |
| 41 | 0.6 A | Numbers 300.00 | — | 73.55 | 22,065 |
| 42 | 1.6 A | Numbers 300.00 | — | 77.52 | 23,256 |
| 43 | 0.6 A | Numbers 300.00 | — | 24.35 | 7,305 |
| 44 | 1.6 A | Numbers 300.00 | — | 21.93 | 6,579 |
| 45 | Supply of round head type non- deteriorating type low voltage cartridge fuse as per RDSO Specn.No.IRS:S-78/92 or latest and Capacity - 2/4/6/10A/16A/20A Amp. (material will be supplied only from approved vendors of RDSO). Inspection: Consignee Inspection Charges: Borne by Railways. Payment Terms: 100% on supply. | Numbers 300.00 | — | 65.76 | 19,728 |
| 46 | Supply of PVC insulated Railway Signalling multi-core Indoor Cable 60core (0.6mm Dia) conforming to IRS:76/89(Amd3) or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs(ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Kilometre 2.00 | — | 1,85,872.85 | 3,71,745.7 |
| 47 | Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution | Per 3000.00 Conductor | — | 10.18 | 30,540 |
| 48 | Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) The colour will be decided by Engineer - in - Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3) | Numbers 2000.00 | — | 65.75 | 1,31,500 |
| 49 | Supply of End plate for above item (04012601) 2.5mm/0.091 in thick as per site requirement. | Numbers 350.00 | — | 12.32 | 4,312 |
| 50 | Supply of End Stopper for above item (04012601) 10mm/0.0394 in width as per site requirement. | Numbers 350.00 | — | 12.32 | 4,312 |
| 51 | Supply of Carrier Rails for above item (04012601) 35mm x 7.5mm, 1mm/0.039 in thickness un-slotted type as per site requirement. | Metre 50.00 | — | 128.75 | 6,437.5 |
| 52 | Supply of Markers strip for above item (04012601) | Numbers 2000.00 | — | 19.17 | 38,340 |
| 53 | Supply of Indicative type Fuse Without holder 6A (System, Rapid or Malnad or RBCO make or similar) as per IRS:S- 80/92 Inspection: Consignee Inspection Charges: None Payment Terms: 100% on Supply | Numbers 100.00 | — | 41.09 | 4,109 |
| 54 | Supply D type fuse block non indicating type low voltage non deteriorating fuse base suitable for fuse link of capacity 2A/6A/10A as per specification IRS:S- 80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on execution | Numbers 100.00 | — | 35.61 | 3,561 |
| 55 | Supply of D type fuse link non indicating type low voltage non deteriorating, capacity 2A/6A/10A as per specification IRS:S-80/92 or latest. Quantity break up of each type of fuse block will be specified by Engineer in-charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% on execution | Numbers 100.00 | — | 36.98 | 3,698 |
| 56 | Supply of Fuse auto changeover system for used in Railway Signalling System as per RDSO/SPN/209/2012 rev.1 with latest amendments. One Automatic changeover Unit comprise 32 nos. of external Non-Deteriorating Type or 'G' type fuses from 0.6 Amp to 4 Amp capacities which are in signalling circuits. System shall have 8 cards with monitoring arrangement of 4 fuses in one card. Inspection:(i) RDSO/RITES: if value of item in work more than 10 lakhs (ii) Consignee: subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy. Inspection charges: (i) Borne by Railways (ii) None Payment Terms: 100% after supply. | Each 15.00 Module | — | 35,235.62 | 5,28,534.3 |
| 57 | Installation wiring testing and commissioning of Fuse change over system (FACS). This includes provision of common Buzzer & indication at ASM Room & ESM Duty Room and painting of fuse details. This also includes fabrication of frame for installation of FACS at Station/ LC gate where installation of relay racks not feasible. Inspection: Consignee Inspection charges: None Payment Terms: 100% on commissioning | Each 15.00 Module | — | 1,065.63 | 15,984.45 |
| 58 | For Station | Numbers 1.00 | — | 1,24,501.93 | 1,24,501.93 |
| 59 | 2V, 80AH | Numbers 55.00 | — | 2,488.75 | 1,36,881.25 |
| 60 | 2V, 500AH | Numbers 55.00 | — | 13,541.42 | 7,44,778.1 |
| 61 | 2V, 80AH | Numbers 55.00 | — | 446.52 | 24,558.6 |
| 62 | 2V, 300AH/ 500AH | Numbers 55.00 | — | 1,187.53 | 65,314.15 |
| 63 | Supply of maintenance stand for relay room / battery room as per samples /drawings approved by the site engineer incharge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after supply. | Numbers 1.00 | — | 2,877.14 | 2,877.14 |
| 64 | Point insulation Complete set as per RDSO/SPN/168/2005 for 1. Switch bracket 'D' bracket insulation for IRS point machine - One set comprises of (a) Side plate LH to Drg. No. S-3266 - 1 No. (b) Side plate RH to Drg. No. S-3265 - 1 N o . (c) Insulating bush to Drg. No. S- 3199 - 4 Nos. (d) Insulating washer to Drg. No. S-8640 - 4 Nos., 2. Split- Stretcher bar 2.1 Insulation for Leading stretcher bars (BG) each set comprising of (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg. No. T-10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg. No. T- 10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO Drg. No. T-10371 - 6 Nos. 2.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg. No. T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg. No. T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg. No. T10371 - 12 Nos 3. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washereach set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg. No. T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg. No. T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO Drg. No. T-10371 - 6 Nos. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Set 16.00 | — | 1,553.25 | 24,852 |
| 65 | Gauge Tie plate insulations per RDSO/SPN/168/2005 as per RDSO drg No: T- 10372Alt2, T- 10368, T- 10371 Alt. 2, T-15083/88/Alt2 & T-11690/Alt2 and as per RDSO/SPN/168/2005 with latest amendments as applicable. Gauge tie plates (52 Kg/60Kg as per site requirement) Insulation for (BG) complete with insulating bush and washereach set comprising of: (a) Insulating plate for insulated tie plate BG as per RDSO Drg. No. T-10372-1 No. (b) Insulating bushing for insulated stretcher bar BG as per RDSO Drg. No. T10368 - 3 Nos. (c) Insulating Washer for insulated stretcher bar BG to IRS 40/84 as per RDSO drg. No. T-10371 - 6 Nos. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Set 16.00 | — | 1,391.62 | 22,265.92 |
| 66 | Ground connections, complete set suitable for IRS type / approved point Machine for ordinary turnout with tongue attachment insulation and other insulation as per RDSO Drg. S/3361@47>47@63 (for IRS type point machine) or RDSO Drg No.SA-9151/52 (for Siemens point machine) with latest amendments. However, the ground connection shall be procured only after confirmation from Railway engineer as per site condition /type of machine/turnout. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Set 16.00 | — | 8,219.59 | 1,31,513.44 |
| 67 | Supply of Electric Point Machine, Non Trailable, Internal Locking, 220Mm Throw with IP 67 Motor, Minimum AC Immunity 400V AC With Tools and Complete Accessories Including Complete Ground Connection and all Insulation, Crank Handle and Along with Clamp Point Lock 60Kg, TWS As Per Drg.No. RDSO/S/11000 As Per RDSO Spn. IRS:S-24/2002 With Amd.01 Or Latest. IRS Type. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | Numbers 12.00 | — | 1,20,528.49 | 14,46,341.88 |
| 68 | Supply of William Stretcher Insulation Set (complete) as per RDSO/SPN/168/2005 with insulating bush and washer to suit point layout and conforming to RDSO Drg.No.T-10372 or latest, T-10368 or latest and T-10371 or latest. 1.1 Insulation for Leading stretcher bars(BG) each set comprising of: (a) Insulating plate for leading insulated stretcher bars BG as per RDSO Drg.No.T-10384 - 2 Nos. (b) Insulating bushing for leading insulated stretcher bars for BG as per RDSO Drg.No.T- 10535- 4 Nos. (c) Insulating Washer for insulated stretcher bar BG as per RDSO drg.No.T-10371 - 6 Nos. 1.2 Insulation for following stretcher bars BG. Each set comprising of: (a) Insulating side plate for insulated stretcher bars BG as per RDSO Drg.No.T-10367 - 3 No. (b) Insulating bushing for insulated stretcher bars BG as per RDSO Drg.No..T-10368 - 6 Nos. (c)Insulating washer for insulated stretcher bars BG as per RDSO Drg.No.T10371 - 12 Nos Inspection: (i) RITES if value of item in work more than 10 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Set 16.00 | — | 464.71 | 7,435.36 |
| 69 | Supply of Track Lead Junction Box (TLJB) as per Drg.No.RST-11509 or latest made from FRP material including brass bolts and hylam board sheet with terminals etc. The technical specifications are as follows: (a) TLJB complete with cover to be in black/red having approximate weight of 4.0 Kg with L-262mm W- 212mm and H 90 mm and all the holes required for mounting on FRP stump (vertical two for each FRP angle) HDPE pipe, cable etc. (b) Each TLJB shall have two Bakelite terminal block fitted horizontally: each Bakelite terminal block shall have two nickel chrome plate M10 brass terminal, 50mm long. Along with each TLJB, nickel chrome plated brass links (two nos.0f adequate strength for vertical linking of the terminals to be supplied. (c) HDPE pipe of size 32/35mm, 380 mm long alongwith two nuts for fixing on the TLJB hole. (d) The FRP stump for mounting the TLJB to be made of one-meter long 30mm X30mmX 4mm angle (2 nos.) and 300mm long 30mm X30mmX 4mm angle (1 no.) fixed at 50 mm from the bottom using galvanised nuts and bolts. The TLJB and the angles for stump should come alongwith holes on them for fixing using galvanised nuts and bolts of adequate strength to be supplied alongwith TLJB drawing no. 11509. Inspection: (i) RITES if value of item in work more than 5 lakhs (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 5 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 50.00 | — | 2,140.3 | 1,07,015 |
| 70 | Supply of B Type Choke as per RDSO Specn.No.IRS:S-65/83 (Amnd. 1) or latest. Inspection: RDSO Inspection Charges: Borne by Railways. Payment Terms: 100% after supply. | Numbers 50.00 | — | 4,933.07 | 2,46,653.5 |
| 71 | Supply of UL standard PPTC fuses complies to UL Thermistor standard 1434 with rating- 2/4 Amps. Capacity wise distribution will be decided by Consignee. Inspection: Consignee. Inspection Charges: None. Payment Terms: 100% after supply. | Numbers 400.00 | — | 50 | 20,000 |
| 72 | Supply of Channel Pins MS (Galvanized) single groove, 7 mm suitable for 4mm Dia bonding wire as per spec No IRS S 17 & RDSO Drg No. S-69/M. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 1000.00 | — | 6.85 | 6,850 |
| 73 | Supply of Hydrometer, Exide make or similar for measuring specific gravity of Battery Graded acid with mounting stand in location Boxes. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 100.00 | — | 309.55 | 30,955 |
| 74 | Multi Section Digital Axle Counter (MSDAC): Supply, Design, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) complete system as per RDSO Specification No. RDSO/SPN/176/2013 version.3 with latest amendments STR No. SIQ 0001 Ver.2.0 or latest. MSDAC Reset procedure shall be as per NWR MSDAC Reset policy. Tenderer shall design the scheme for provision of required number of evaluators, reset equipment's, trackside junction boxes, detection points and track clearance relays etc and shall be submitted along with the offer. Remote Diagnostic System shall be provided at station. Length of the cable required for each DP and Rail Type will be specified at the time of issuing call Letter. [This also includes supply of 10% all types of spare cards, LV Boxes, Wheel sensors and other essential modules as specified in RDSO Spec, it shall be rounded to nearest integer subjected minimum of one item. One set of Specialized Tool and Measuring equipment's as per RDSO specifications shall be supplied per location (Station/ALH/OC/IBH). (Per Detection Point = DP). Note: It also includes supply and Installation of any earthing arrangement, if required as per OEM specification. Inspection: (i) RDSO - for supply items. (ii) Consignee - for other execution. Inspection Charges: Borne by Railways. Payment Terms: 80% after Supply, 20% after execution & commissioning. | Per 35.00 Detection Point (DP) | — | 3,87,561 | 1,35,64,635 |
| 75 | Installation testing & commissioning of High Availability Single Section digital axle counter (HASSDAC) single section type system complete with track devices and other associated accessories. This includes fixing of device, relays, wiring, lacing /dressing, cable termination with lug eyelet, drilling holes in rails, Installation of track devices and make it functional along with existing UFSBI/block instrument. Material required other than supply item of HASSDAC, shall be arranged by contactor to make it functional. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Commissioning. | Set 2.00 | — | 24,069.8 | 48,139.6 |
| 76 | Supply of hand operated track drilling machine for bonding hole. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after supply. | Numbers 5.00 | — | 9,689.55 | 48,447.75 |
| 77 | Installation and wiring of LED signals lamps for auxiliary/subsidiary signals/main signals (i.e. route, shunt, calling on, Red, Yellow, Green) as per instructions given by engineer incharge. Complete wiring inside the signal unit with 2.5 sq. mm multi strand wire of different colour according to signal aspect with copper lug as per standard practice. The contractor will supply all materials required for installation. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after execution. | Numbers 12.00 | — | 215.29 | 2,583.48 |
| 78 | Supply of Colour Light Signal Complete. This includes: - (1) Post Tubular 140 mm Dia, as per IRS: S-6/81 or Latest & RDSO Drg. No. SA-24625 (Advance). (2) CI Base (As per IRS S-10 & RDSO Drg. No. 2011/M with latest assembly). (3) Number plate to Drawing No. S 23149 Alt.1 =1 No, Number plate clamps to Drawing No. S 23148 Alt.1 =2 no (4) Ladder Assembly, as per RDSO Drg. No. SA-23156, with Base, Ladder Guard rail (complete) to Drawing No. SA 23138 Alt.1(1No), Platform to Drawing No. SA 23134 Alt.1(1 No), Front Maintenance Platform, MS Supporting bracket to Support Ladder. Ladder stay (small) to Drawing No. S 23159 Alt. 1 (2 Nos.) , Ladder stay (large) to Drawing No. S 23160 Alt. 1 (2 Nos.) , Ladder section to Drawing No. SA 23157 Alt. 1(1 Nos.)Stay clamp to Drawing No. SA 2062/M (2 no), Rail Clamp to Drawing No. S 2066/M (1 No.) (5) Signal Front Staging Complete Assembly for CLS Unit. (6) Signal back staging as per extent NWR Practice. Note: Height of the Post shall be 5.5 Long. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 10.00 | — | 12,987.53 | 1,29,875.3 |
| 79 | Supply of Offset brackets for Main Signal, made of tubular steel, outer diameter 140 mm, thickness of pipe 4.5 mm. horizontal length of pipe 545 mm & vertical length of pipe 324 mm with fixing arrangement on Main Signal post as per Drawing No SW/554/G/R. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 5.00 | — | 5,370.61 | 26,853.05 |
| 80 | Supply of Offset brackets for Shunt Signal, made of tubular steel, outer diameter 89 mm, thickness of pipe 4.5 mm. horizontal length of pipe 324 mm & vertical length of pipe 324 mm with fixing arrangement on Shunt Signal post as per Drawing No SW/354/I. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 5.00 | — | 5,218.57 | 26,092.85 |
| 81 | 2/3/4 aspect signal unit mounted directly on signal post. | Numbers 10.00 | — | 2,632.57 | 26,325.7 |
| 82 | Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway signalling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 10.00 | — | 32,215.42 | 3,22,154.2 |
| 83 | Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway signalling suitable for RE area THREE Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 10.00 | — | 33,749.49 | 3,37,494.9 |
| 84 | Supply of Non-Metallic (FRP) colour light signal housing multi-unit type for railway signalling suitable for RE area FOUR Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Rev 2.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 10.00 | — | 36,050.59 | 3,60,505.9 |
| 85 | Supply of Position Light Shunt Signal Unit Complete with Post (made of GI Pipe of 80 mm Diameter Medium Class IS Spec. No. IS: 1239 Pt. 1/1990, Base, Hood, Cover etc as per Drg. No. SA-23840 suitable for LED Signal Lighting Unit. (Supply of LED Unit is not covered in this item) Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Set 5.00 | — | 5,172 | 25,860 |
| 86 | Erection of Position Light Shunt signal with Base, Post, Signal unit and fixing of Number Plates. The work shall be done as per instructions of Rly engineer at s i t e . Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers 5.00 | — | 2,142.22 | 10,711.1 |
| 87 | Supply of Junction route indicator unit 3 ways (Without Lenses & Holder) as per Drg. No. RDSO SA 23403 suitable for LED Signal Lighting Unit & as IRS:S-66/84 amndt-1 or latest.(Supply of LED Unit is not covered in this item) Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee- if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i) Borne by Railways (ii) None Payment Terms: 100% on Supply | Numbers 3.00 | — | 28,945.94 | 86,837.82 |
| 88 | Fixing of Junction type Route Indication 1-Way/2-Way/3-Way/4-Way/5-Way/6- Way on the top of the signal post. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers 2.00 | — | 710.88 | 1,421.76 |
| 89 | Supply of Different warning Boards / Calling on Board used for Railway Signalling system as per latest specification. This includes Painting and retro reflective arrangement should be as per IRSEM. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers 5.00 | — | 5,581.54 | 27,907.7 |
| 90 | Casting of CC Foundation for Signal Post in the ratio of 1:3:6 as per Drg. No. CSTE/NWR/SOR/21/A using standard size of foundation/galvanized holding down bolts required for erection of colour light signal post. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement-sand mixture (aggregate will not exceed 3.8 cm). Aggregate, cement, sand and holding down bolts will be supplied by contractor. Any machines & tools, if required for execution of this item, will be arranged/provided by contractor. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers 20.00 | — | 11,266.56 | 2,25,331.2 |
| 91 | Casting of C.C. Foundation for Position Light Shunt Signal/ Indicator/SPI as per Drg. No. CSTE/NWR/SOR/22 in ratio 1:3:6 by using standard size of galvanized holding down/foundation bolts. Item includes excavation, ramming of CC using vibrator, curing and plastering with 1:4 cement sand mixture. Aggregate cement, sand and holding down bolts, will be supplied by contractor. Any machines and tools, if required for execution of this item, will be arranged/provided by contractor. Note: As per available site conditions, if sizes of foundations are required to be decreased/ increased and same has been approved/agreed by engineer incharge then variation in CC work will be calculated on volumetric basis as per rates of these items. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Numbers 5.00 | — | 7,594.4 | 37,972 |
| 92 | Supply of Dual Tone Bell /Buzzer with Flasher arrangement and 20Watt horn working on 24 V DC/ 110 V AC for warning road users at LC gates. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply | Set 5.00 | — | 6,244.87 | 31,224.35 |
| 93 | Supply of Office Chair make Godrej CH- 7B or similar of reputed brand. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 4.00 | — | 3,031.16 | 12,124.64 |
| 94 | Supply of Office table with laminated top with three drawers on left hand side and one locker on the righthand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm)or Superior of reputed brand. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 2.00 | — | 18,097.9 | 36,195.8 |
| 95 | Supply of Steel Plain Almirah with 4 adjustable shelves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 3.00 | — | 19,582.65 | 58,747.95 |
| 96 | Supply of Panel cum Block Instrument table complete as per approved drawing. It includes any modification to it if required by Engineer-in-charge at site. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 2.00 | — | 41,593.78 | 83,187.56 |
| 97 | Supply of Apparatus Case Single (Large) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11500. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board. Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 15.00 | — | 17,986.94 | 2,69,804.1 |
| 98 | Installation of Apparatus Cases Single (Large) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of lamp holder, switch and lamp etc. in Apparatus Case. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers 15.00 | — | 1,250.54 | 18,758.1 |
| 99 | Supply of Apparatus Case half (Medium) NE Rly Type as per Drg. No. CSTE/6088 fitted with two nos of E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg. No. 3377 as per RDSO drawing No. RDSO/S-11507. Note: This item includes the supply of 2 Nos E Type Lock fitted on both doors, along with two Keys. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee if value of whole item in work less than 10 lakhs or as per extant instructions by Railway Board. Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 15.00 | — | 11,360.32 | 1,70,404.8 |
| 100 | Installation of Apparatus Cases Half (Medium) with 'E' type lock on CC foundation. This includes filling of location foundations with river bed sand and plastering on top of the sand. Supply of 'E' Type lock has been covered in supply of Apparatus case separately. It covers fixing of Location lamp holder, switch and lamp etc. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers 15.00 | — | 761.56 | 11,423.4 |
| 101 | Single (Large) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | Numbers 15.00 | — | 8,290.81 | 1,24,362.15 |
| 102 | Half (Medium) Case Apparatus case / SS location box as per Drg No. CSTE/5074 | Numbers 15.00 | — | 6,329.4 | 94,941 |
| 103 | Supply of Phenolic laminated Sheet, grade P3 in standard size of 1220 X 1220 x 10 mm as per spec. No IS 2036 of 1995 or latest. Test report of manufacture to be supplied. Inspection: (i) RITES if value of item in work more than 10 lakhs or as per extant instructions by Railway Board. (ii) Consignee Inspection Charges:(i) Borne by Railways (ii) None Payment Terms: 100% after Supply. | Numbers 30.00 | — | 5,593.87 | 1,67,816.1 |
| 104 | Single Case (Large Case) | Numbers 15.00 | — | 2,821.59 | 42,323.85 |
| 105 | Half Case (Medium Case) | Numbers 15.00 | — | 823.19 | 12,347.85 |
| 106 | Fixing of ARA(M-6) Terminals /Screw less connectors / modular disconnect terminal blocks and fuse blocks on phenolic laminated sheets and fixing by stainless steel/brass nuts & bolts. This includes provision of two additional holes on the board on either side for cable conductor entry. (Supply of all above terminals have been covered separately in Chapter 4 of SOR) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after installation. | Numbers 2000.00 | — | 15.07 | 30,140 |
| 107 | Supply of Round head type non deteriorating type low voltage cartridge fuse as per Spec No IRS/S/78/92 with latest amendments 2A/4A/6A capacity. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after supply. | Numbers 100.00 | — | 71.22 | 7,122 |
| 108 | Supply of two pin Lamp holder Bakelite type for Apparatus Cases. (ISI mark of reputed make) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after supply | Numbers 100.00 | — | 53.42 | 5,342 |
| 109 | Cable Size 6C x 1.5 Sq. mm. | Numbers 3.00 | — | 4,220.06 | 12,660.18 |
| 110 | Cable Size 12C x 1.5 Sq. mm. | Numbers 3.00 | — | 5,871.91 | 17,615.73 |
| 111 | Cable Size 30C x 1.5 Sq. mm. | Numbers 3.00 | — | 15,116.04 | 45,348.12 |
| 112 | Tools for installation of Rapid Cable Joint kit. | Numbers 2.00 | — | 6,259.55 | 12,519.1 |
| 113 | Supply of Medium class GI pipes 100 mm Dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Metre 500.00 | — | 915.45 | 4,57,725 |
| 114 | Fixing of Medium class GI pipes 100 mm dia(4.5 mm thickness) as per IS 1239 (Part 1): 2004 with coupling on culverts bridges as per Drg. No. CSTE/NWR/SOR/06 to 12 or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work (if required) to protect the cables from sharp edges and sudden bends. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after installation. | Metre 500.00 | — | 228.87 | 1,14,435 |
| 115 | Length wise (up to 2 cables). | Running 3000.00 Metre | — | 17.81 | 53,430 |
| 116 | Width wise (more than 2 cables) | Running 7000.00 Metre | — | 38.36 | 2,68,520 |
| 117 | Supply of Double Wall Corrugated (DWC)-HDPE pipe/duct of size 200 mm outer Dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Spec. No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part-II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O-Ring 2) Spacers3) Tees4) Bend,5) End-capDWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs or as per extant policy (ii) Consignee subject to procurement from RDSO approved vendors if value of whole item in work less than 10 lakhs or as per extant policy Inspection Charges: (i)Borne by Railways(ii) None Payment Terms: 100% after Supply | Metre 200.00 | — | 461.51 | 92,302 |
| 118 | Supply of Thermo shrink Universal Jointing kit for Quad Cable (for straight joints) as per RDSO spec IRS/TC-77/2012 revision 3 With latest Amd. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | Numbers 4.00 | — | 2,586 | 10,344 |
| 119 | Horizontal direction drilling/boring without damage of surface road /track using Auger Machine (HDD machine) or by Closed trench Method. The bore shall be upto 200 mm Dia & shall be done at the depth of minimum 1200 mm from the ground level. The ground level shall be considered ignoring the bank height of the bank of the road. The length of the bore shall be minimum 4 Mtrs long. This includes insertion of different Dia DWC- HDPE pipe/ GI pipes coupling etc. as per direction of Engineer In charge. Note: - Pipe Supply is not covered under this item. Contactor shall provide all material required for boring and adequate nos. of labours for proper laying of cables into the bore. Cable shall be laid cautiously so that it should not get damage due to rough handling & pressure on cable. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Metre 1500.00 | — | 1,447.77 | 21,71,655 |
| 120 | Excavation of cable trench as per cable route plan, 1.2 Mtr. deep and of 0.3 Mtr. to 0.6 Mtr. wide at bottom as per RDSO sketch No. SDO/CABLE LAYING/003 or latest alongside the track in normal (all type) soil/strata, conforming to distances as per cable route plan and refilling. This work includes clearing of route from bushes etc, covering of cable laid in trench by loose soil for a layer of 50mm thickness approximately before covering by bricks. The work shall be done as per the extant practice on North Western Railway and instructions of Railway Engineer at site. In case 1.2m depth of trench is not achievable due to site conditions, specific approval of JA grade officer will be required for each site where trench depth of 1.2m is not possible. Without the approval of JA Grade officer, no payment for trenching will be made for trench depth less than 1.2m. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum 2500.00 | — | 330.1 | 8,25,250 |
| 121 | Digging of trench 1.2 Mtrs. deep from rail flange/ road level and 0.3 Mtrs to 0.6 Mtrs wide and back filling after placing of DWC/ RCC/GI pipe. (Placing of DWC/RCC/GI pipe covered separately). The ballast disturbed be screened and dressed as required by Engineer-in- charge or his representatives and road tarred immediately. For track crossing, Drg. No. CSTE/3644 Pg.7 of 11 and for Road Crossing, Drg. No. CSTE/3644 Pg. 5 of 11 are to be followed. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum 500.00 | — | 330.1 | 1,65,050 |
| 122 | Digging of cable trench 0.3 Mtrs. Deep and 0.3 Mtrs. Wide on Asphalted Platform / Road / Hard rocky area. Refilling with earth levelling of trenches & restoring the original surface of trenches. The sharp edges will be smoothened out in bottom of the chase and will be levelled properly. In hard rocky ground area, cables will be laid normally on layer of shifted earth of 0.05 mtrs thickness previously deposited at bottom of the trench and cables will be covered with layer of sand or shifted earth of 0.1 mtr thickness. In case sharp edges of rocky ground cannot be protected from shifted earth then GI/ CI /PVC /DWC/ HDPE pipes will be used, if numbers of cables are small. In case number of cables are large RCC duct will be used. In isolated cases, it can be given smooth surface by using either masonry bricks or cement concrete. A row of bricks shall then be placed length wise on the top and jointed with cement mortar and layer of concrete with cement plaster shall be provided on top of the same. Note: This item in hard rocky area will be operated only where normal depth i.e.l.2 mtr is not possible and it will be decided by site engineer/unit officer incharge of work. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum 500.00 | — | 605.41 | 3,02,705 |
| 123 | Digging of cable pit (min 2x2x1m) as per instruction of Site Engineer, supplying and filling of sand before and after coiling the cables, covering top of the cable pit with stones and providing brick masonry on all four sides of the cable pit and plastering thereafter. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | Numbers 1.00 | — | 15,051.67 | 15,051.67 |
| 124 | Laying of S&T Cables of various cores/ pairs/ quads in trenches/ GI pipes/ RCC pipes/ DWC pipes/ Trunking. This also includes laying of cables in track crossings & road crossings. Item includes provision of labels of coloured plastic adhesive tapes or any other identifiable material on each cable to give the cable number at each Gantry Post/hectometer post. (Cables will be meggered before and after its laying by contractor under supervision of Railway Representative and he will submit the meggering report of each testing). Length of the cable laid includes the length of the cable coiled for termination purposes. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | Running 85000.00 Metre | — | 10.95 | 9,30,750 |
| 125 | Cement concrete work for miscellaneous items in the ratio 1: 3: 6. Item includes excavation, ramming, curing and plastering with cement & sand mixture (aggregate not exceeding 3.8 cm.) (Aggregate cement & sand to be supplied by the contractor)(cum is Cubic Meter). Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum 2.00 | — | 4,366.61 | 8,733.22 |
| 126 | Providing brick masonry in ratio 1:6 cement and mortar including plastering with 1:4 cement and sand mixture both sides, 20 mm thick each with contractor's owned class II bricks, including excavation, curing, grouting, bolting etc. wherever required. Bricks sand and cement to be supplied by the contractor.(cum is Cubic Meter) Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution | cum 2.00 | — | 2,395.61 | 4,791.22 |
| 127 | Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest and conforming to RDSO Drg. No. SDO/ RDSO/E&B/001. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17 mm Dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply | Lot 10.00 | — | 21,098.23 | 2,10,982.3 |
| 128 | Installation of Unit Maintenance Free Earth as supplied under item no. 13010300 above It includes: ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm Dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest and conforming to RDSO Drg. No. S DO/RDSO/E&B/001 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after execution and testing. | Set 10.00 | — | 9,461.53 | 94,615.3 |
| 129 | Provision of Ring Earth for EI system which includes supply of all components of earthing & bonding system like earth electrode, earth enhancement material, earth pit, Equi- potential earth busbar, connecting cables and tape/strips and other associated accessories in accordance with RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest, consisting minimum 8 Nos. of earth pits connected in a ring to achieve less than 1 Ohms earth resistance for connecting EI equipments, relay racks, panel, power equipments as per Signal Engineering Practice. Diagram of ring earth should be supplied to Railway for Approval before execution. All related material as recommended by RDSO in Spec. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest, will be supplied by the contractor. basic material for one e a r t h pit is given below: (a) Copper bonded steel electrode of 3.0 m long, 17 mm Dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (f) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (g) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (h) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipments to SEEB (i) Supply of copper lug sleeve for 3/16 cable Note: Earthing arrangement for EI must be as per RDSO guidelines issued by RDSO vide TAN/3006 dated 30.06.2025 or latest. Inspection: RDSO Inspection Charges: Borne by Railways Payment Terms: 100% after Supply. | Station 1.00 | — | 1,82,923.54 | 1,82,923.54 |
| 130 | Installation, testing and commissioning of Ring Earth for EI system which includes installation of all components of earthing & bonding system like earth electrode, earth enhancement material, earth pit, Equi- potential earth busbar, connecting cables and tape/strips and other associated accessories in accordance with RDSO Spec. No. RDSO/SPN/197 Version 1.0 dtd. 04.07.2016 or latest consisting minimum 8 Nos. of earth pits connected in a ring to achieve less than 1 Ohms earth resistance for connecting EI equipments, relay racks, panel, power equipments as per Signal Engineering Practice. Diagram of ring earth should be supplied to Railway for Approval before execution. Installation of one earth pit includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 K g ) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and busbars to various equipments. Earth electrode of 17.20 mm Dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential busbar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential busbar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: Earthing arrangement for EI must be as per RDSO guidelines issued by RDSO vide TAN/3006 dated 30.06.2025 or latest. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after commissioning. | Station 1.00 | — | 45,730.88 | 45,730.88 |
| 131 | Supply and Installation of earth electrode including MS flat for signalling equipments on lever frame, apparatus cases, signal, relay racks, cable termination rack, block instrument etc. (supply & installation of earth electrode as per drawing no. RE/S&T/DRG/Tender/SK/398/94 for apparatus cases, signal post & other equipments as per instruction on earthing of S&T equipment. Laying of earth lead mild steel flat of size 35mmx6mm and fixing of lead MS flat to earth electrode and lever frame, signal post & apparatus cases as per Drg. No. CORE/S&T/ALD/SK/591/2008, 592/2008 and 593/2008 respectively and instructions on earthing at S&T equipment and providing cement enclosure for earth electrode as per drawing no. RE/S&T/Sig./Tender/SK/13/85 Alt. A) Note: This item requires for earthing of all the A/Cases & Signal as per RE standard. Inspection: Consignee Inspection charges: None Payment terms: 70% after supply, 20% after installation & 10% after commissioning | Numbers 30.00 | — | 8,199.86 | 2,45,995.8 |
| 132 | Supply of Digital Multi-meter with datalogging, Display count 50000, True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, Frequency Range upto 60MHz, with set of leads & carrying case. Model- Fluke 287 or Stanone/SMM180 or Keysight U1252B or Superior. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 2.00 | — | 53,008.89 | 1,06,017.78 |
| 133 | Supply of electronic Cable route tracer/locator with underground cable and pipe locating receiver and cable avoidance tool that provide location of armoured OFC, signalling and telecom, power cable etc. Model RD8200G or STLOC10GPS equivalent or superior. Minimum specifications- Battery life- 24 hours continuous use, Backlit LCD display, IP65, multi-frequencies -12 frequencies, Variable pitch & live sound, Depth Measurement- upto 10meters depth, digital 3-digit LCD readout with ± 3% accuracy. Datalogging with export facility to .csv/excel formats. Transmitter output power- 10W with multiple power setting options, Warranty-3 years. Inspection: RITES Inspection Charges: Borne by Railway Payment Terms: 100% after Supply. | Numbers 1.00 | — | 5,00,975.83 | 5,00,975.83 |
| 134 | Supply of Cable Fault locator with minimum specifications as, TDR range upto 10km, zero dead-zone, TDR resolution 0.1m, TDR accuracy ±0.01%., with 3 years warranty. Make: Tempo/Stanley Communication Model Sidekick Plus Kit Standard (1155-5001) or equivalent or superior. Inspection: RITES Inspection Charges: Borne by Railway Payment Terms: 100% after Supply. | Numbers 1.00 | — | 5,78,945.76 | 5,78,945.76 |
| 135 | Supply of Digital Cable Insulation Tester for measurement of cable insulation resistance with auto range 0-500 V DC. Modal: SIT 500 equivalent or superior from any reputed make Fluke or Megger or Stanone or Superior. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 2.00 | — | 10,457.72 | 20,915.44 |
| 136 | Supply of Digital Earth Resistance Tester for measurement of earth resistance with 3.5 digital LCD, 12.5 mm screen segment and Range -0.5 Ohms to 500 Ohms. Accuracy- ±2%. WACO or from any repudiated make. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply. | Numbers 2.00 | — | 10,540.73 | 21,081.46 |
| 137 | Standard Tool kit for signal maintenance (suitable for RE area working) with following items (with small size canvas log) (i) Insulated combination plier of 8" = 1no. (ii) Insulated long nose plier of (road wise) 6" =1 no. ( iii) Insulated wise stroper plier of 6"=1 no ( iv) Insulated screw driver set(5 piece) =1 set (v) Side cutting plier 6" =1 no (vi) Hex with frawise 12"= 1 no (vii) Double end spanner set (6 to 32mm) = 1 set (viii) Adjustable spanner set 8" =1 no (ix) Ball pin hammer 200 gm =1 no (x)Soldering iron 25 watt =1 no ( xi)Torch cell LED (3 cell) Eveready/jeep = 1no (xii) Auto ranging digital multi-meter (Branded) =1 n o (xiii) Crow bar steel/ tommy bar =1 no Inspection: Consignee Inspection charges: None Payment terms: 100% after supply | Set 1.00 | — | 6,331.74 | 6,331.74 |
| 138 | Supply of Vacuum Cleaner, Eureka Forbes or from any reputed make only as per specification given below:- Voltage-230V AC,50Hz, Input Power(IEC)-1000 Watt, Suction of the motor 1700 mm of water column , Airflow-30 litres/second, Dust collection capacity-61(dry), 81(wet), Variable power option-2 Speed, Blower function, Air filtraction-2 Stage, Hepa filter, Dust collection type-Washable dust bag, On board accessory storage. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply | Numbers 2.00 | — | 26,892.17 | 53,784.34 |
| 139 | Supply of Safety lock Godrej or Navtal make size as approved by site engineer. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply | Numbers 200.00 | — | 134.72 | 26,944 |
| 140 | Supply of Obstruction test piece 3mm/5mm as per sample approved by Engineer incharge. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Supply | Numbers 5.00 | — | 2,960.95 | 14,804.75 |
| 141 | Full Case | Numbers 25.00 | — | 143.82 | 3,595.5 |
| 142 | Half Case | Numbers 25.00 | — | 98.61 | 2,465.25 |
| 143 | Dismantling of Concrete foundation/ Demolishing RCC/CC/Stone work /Cutting Tarcarpenting/ CC Flooring/ Precast concrete slab/ Brick work including leading the debris inside Railway limit or outside Railway limit as directed by site in charge. This work to be done by contactors with his own vehicle and labour. (cum is Cubic Meter) Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | cum 4.00 | — | 704.02 | 2,816.08 |
| 144 | Complete painting and varnishing work at a station (3/4 Line). This includes painting of signal posts and fittings, apparatus cases, point machines, junction boxes, rail post etc. This also includes varnishing, letter writing on relays, terminal Nos., apparatus cases, point machine, Signal Nos. and other details as per Signal Engineering Manual and instructions of Engineer at site. The item includes painting of distances of main cable run from G.P nearest to cable run and painting of distances of signals from nearest line on the signals base. At least two coats of paint are to be applied besides primary coating of red oxide. This includes supply of paints, varnishes and all other material required for complete painting work at a station. This includes painting on existing functional units also. The painting shall consist of initial red oxide / base paint followed by at least two coats of the paint as per standard painting scheme. This item also includes painting of interlocked gate attached to the station. Location box no. shall be painted on both sides. Inspection: Consignee Inspection Charges: None Payment Terms: 100% after Execution | Station 1.00 | — | 44,463.2 | 44,463.2 |
| 145 | Supply & fixing of Crank Handle Box & SM's key box of size 450 mm x 250 mm x150 mm and made of 12 mm thick teakwood with a glass front, lock and sealing arrangement. All material like lock, teakwood, handles, hinges, glass sheet of 3 mm thick will be supplied by the contractor. Box will be polished and description will be written as per instructions of Engineer in charge. Inspection: Consignee Inspection Charges: None Payment Terms: 100 % after Execution | Numbers 2.00 | — | 2,203.51 | 4,407.02 |
| 146 | Supply of permanently Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt. 3 or latest. The item also includes supply of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: (i) RDSO/RITES if value of item in work more than 10 lakhs (ii) Consignee if value of whole item in work less than 10 lakhs as per extant instructions by Railway Board. Inspection Charges: (i)Borne by Railways (ii) None Payment Terms: 100% on Supply | Kilometre 2.00 | — | 58,145.01 | 1,16,290.02 |
| 147 | Laying of permanently Pre-lubricated HDPE duct, 40 mm OD, 33 ID as per RDSO specification No. RDSO/SPN/TC/45/2013 Rev. 2.0 Amdt. 3 or latest. The item also includes installation of all the accessories of HDPE duct like end caps, collars, bends, couplers etc. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | Kilometre 2.00 | — | 14,536.25 | 29,072.5 |
| 148 | Blowing/drawing of OFC cables in the HDPE duct along with all the protective work as per instructions of engineer incharge at site. Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Execution. | Kilometre 2.00 | — | 13,003.54 | 26,007.08 |
| 149 | Supply of VF Transformer (1120:470/1120:1120/ 470:470/470:600/ 1200:600 Ohm) as per Specification No. IRS-TC-76/2021 Ver 1.0 or latest (Cylindrical type) or IRS/TC/22/ 2021 Ver 1.1 or latest (Rectangular type). Inspection: Consignee Inspection Charges: None. Payment Terms: 100% after Supply. | Numbers 10.00 | — | 1,077 | 10,770 |
| Schedule total | ₹3,61,90,171.76 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-ACS10corrected.pdf
ATTACHMENT
ACSNo.1GCC-2022.pdf
ATTACHMENT
Correction slip No 2
ATTACHMENT
ACS-2toGCC-2022_2022-CE-1-CT-GCC-2022-POLICY_13.12.2022.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_3ACS-311.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_4ACS-4.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_5GCCApril-2022.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_6ACS-61.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_7ACS-7.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_8ACS-8.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_9ACS-9.pdf
ATTACHMENT
AdvanceCorrectionSlipNo_10ACS-10.pdf
ATTACHMENT
GCC2022correctionslipNo.11.pdf
ATTACHMENT
EI_Guidelines.pdf
ATTACHMENT
Offer-NWR-DaharKaBalajiStn.pdf
ATTACHMENT
PolicyguidlinesofSNTcablelayinginductsdtd11-03-202411_compressed.pdf
ATTACHMENT
TentativeESPofDKBJ.pdf
ATTACHMENT
TelecomCircularNo.09.pdf
ATTACHMENT
NIT25032026.pdf
ATTACHMENT
2.TD2026-27Dy.CSTE-GSU-JPDKBJTENDERDOCUMENT.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .