Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.0 LAccepted-AOC 203 NIVAAN LAXMI SOCIETY PLOT NO 169 SECTOR 19 KHARGAHAR NAVI MUMBAI 410210 | RAIGAD | MAHARASHTRA | 410210 | L1 | Accepted-AOC Being 1st Lowest | |
| 2 | L2₹32.0 L+₹4.4 L (15.9%)Rejected-Finance | L2 | Rejected-Finance Being 2nd Lowest | |
| 3 | L3₹32.1 L+₹4.5 L (16.2%)Rejected-Finance | L3 | Rejected-Finance Being 3rd Lowest | |
| 4 | L4₹34.3 L+₹6.7 L (24.2%)Rejected-Finance | L4 | Rejected-Finance Being 4th Lowest | |
| 5 | L5₹44.7 L+₹17.1 L (62.1%)Rejected-Finance GALA NO B 128 129 130 SATYAM INDUSTRIAL ESTATE OFF KARVE ROAD OPP SNDT COLLEGE ERANNDWANE PUNE 411038 PUNE MAHARASHTRA 411038 | PUNE | MAHARASHTRA | 411038 | L5 | Rejected-Finance Being 5th Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
4 Jan 2023, 6:00 pmClosed
CWE KARANJA
CWE KARANJA NAVAL STATION KARANJA URAN RAIGAD - 400704
CERTAIN ESSENTIAL REPAIR TO INTERNAL CONTROL PANEL, SWITCHGEARS AND INCL CONNECTED WORK OF CENTRAL AC PLANTS AT NAVAL STATION KARANJA
2022_MES_568254_1
84195-K/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
NAVAL STATION KARANJA
Please refer tender documents
8 documents required · 8 mandatory
₹500
GARRISON ENGINEER (NW) KARANJA
₹1 L
3 Mar 2023
9 Dec 2022
6 Jan 2023
9 Dec 2022
4 Jan 2023
23 Dec 2022
Amount
Supply and fix in repairs auto capacity regulator solenoid valve of Make : Rotex, 220V, 50Z or equivalent in Avcon, Accel cat part No 50 including connecting of interlock wiring, nuts, bolts, washers etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs coil for solenoid valve SP-180 cat part No 50-A of Make : Accel, Sporlan, Rotex connecting into liquid line including interlock wiring, nuts, bolts, washers, etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement power contactor 3 pole, type ML-1.5 with 2 NO + 2 NC aux contracts with standard coil voltage 415 volts, rating 25 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement power contactor 3 pole, type ML-2 with 2 NO + 2 NC aux contracts with standard coil voltage 415 volts, rating 32 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement power contactor 3 pole, type ML-3 with 2 NO + 2 NC aux contracts with standard coil voltage 415 volts, rating 40 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 4.5 to 7.5 Amp with single phasing protection complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 9 to 15 Amp with single phasing protection complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement bimetal overload relay type MN-02 of relay range, 14 to 23 Amp with single phasing protection complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement electronic timer 800 SQA working voltage 240V 50 Hz complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of air break contactor Model No 3TS3500-0A with auxiliary 3TX400--2A 1 NC 415 V, 50 Hz, AC complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB SP 5 to 32 amp rating 240V, 10KA 'C' curve complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB SPN 32 amp rating 240V, 10KA 'C' curve complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB SPN 40 to 63 amp rating 240V, 10KA 'C' curve complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB TP 40 to 63 amp 415V 10KA 'C' curve complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB TPN 16 to 32 amp 415V 10KA 'C' curve complete all as specified and as directed by Engr-in-charge.
Supply and fix for MCB TPN 40 to 100 amp 415V 10KA 'C' curve complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement MCCB 3 Pole, 415 V, fixed type, 25 to 100 Amps with breaking capacity 16 KA complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement MCCB 3 Pole, 415 V, fixed type, 400 Amps with breaking capacity 36 KA complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement power contactor 3 pole, type MNX 12, 1 NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement power contactor 3 pole, type MNX 18, 1 NO + 1 NC aux contracts with standard coil voltage 240 volts, rating 30 Amp complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs of Motor and Voltage protective device as per existing make and type complete all as specified and as directed by Engr-in-charge.
MVPD EC 5-30 A
MVPD EC 30-220A
Micro VPD (Split) 360-500V AC
Supply and fix in replacement of microprocessor of compressor upto 60 TR complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of microprocessor of compressor for 60 TR to 100 TR complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of microprocessor of compressor for 100 TR to 250 TR complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of single phase preventor type SPP VSP3 3 phase, 415 Volts, 50 Hz AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of CVT for chiller controller power supply 3 phase, 415 Volts, 50 Hz AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement of single phase preventor type SPP VSP3 3 phase, 415 Volts, 50 Hz AC complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sprinkler assembly complete with header nozzles made out of galvanised iron suitable to fix in cooling towers of 71 TR and above capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sprinkler assembly complete with header nozzles made out of galvanised iron suitable to fix in cooling towers of 61 to 70 TR capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sprinkler assembly complete with header nozzles made out of galvanised iron suitable to fix in cooling towers of 51 to 60 TR capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sprinkler assembly complete with header nozzles made out of galvanised iron suitable to fix in cooling towers of 31 to 50 TR capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs sprinkler assembly complete with header nozzles made out of galvanised iron suitable to fix in cooling towers of below 30 TR capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply, assembly and erection in repair of GI sheet with C & SS rectangular/square duct made out of L shapped hollow profile, duly factory boxed, incl all accessories such as corner, cleat, carraige bolt, gasket and appropriate sealant on longitudinal joint etc complete of size 24 gauge complete all as specified and as directed by Engr-in-charge.
Material and labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 50mm including the following complete all as specified and as directed by Engr-in-charge. (a) Cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of milllscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12mm/ 50mm at maximum intervals of 1.2m.
Material and labour in repair for duct insulation with resin bonded fibre glass wool roll of density 24 Kg/Cum, with factory laminated aluminium vapour barrier, thickness of insulation 40mm including the following complete all as specified and as directed by Engr-in-charge. (a) Cleaning the duct surface (to be insulated) by scrapping carefully with wire brush etc. to make the surface completely free of milllscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) Applying rubber based adhesive CPRX compound. (c) Sealing of all longitudinal joints and circular overlaps with and including aluminium foil tape 50mm wide, to make the insulation leakproof. (d) Securing the insulation with and including mechanically fastened nylon/ steel straps of size 12mm/ 50mm at maximum intervals of 1.2m.
Material and labour in repair for accoustic lining to the ducting by using FG crown 200x25mm thick rigid board density 32 Kg/cum covered with Rptissue and 28 gauge aluminium. Perforated sheet and using GI nuts, bolts and washer for the entire duct etc., complete all as specified and as directed by Engr-in-charge.
Supply and fix for supply / return / exhaust air grilles /of powder coated aluminium with aluminium volume control dampers with anti smudge ring and removable core complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs cooling tower fan assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 70 TR and above capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs cooling tower fan assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 61 to 70 TR capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs cooling tower fan assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 51 to 60 TR capacity AC plants complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs cooling tower fan assembly with low speed fan with noise level not exceeding 75 dBa made out of propeller type light weight solid/ hollow FRP rust resistant with statically and dynamically balanced blades suitable for 21 to 50 TR capacity AC plants. TR AC plants complete all as specified and as directed by Engr-in-charge. Notes for Item No. 40 to 43: (i) Fan speed shall not exceed 60 MPS. Outlet velocity of air shall not be less than 610 mtrs/ min. (ii) Fan shall be protected by a fan guard and bird screen of galvanised steel construction. (iii) G SS/ SS 304 fan guard shall be provided over the fan motor for protection against rain water.
Dismantling and removing old unserviceable compressor sealed unit of scroll type compressor carefully and supply, installation, testing new sealed compresor unit of capacity 12.5 TR Model No SZ185S4RC of Make Blue Star/ Danfoss complete with all standard accessories as per existing model installed at AC plant complete all as specified and as directed by Engr-in-charge. Notes: (i) Sealed unit shall be purchased from authorised dealers/agents (ii) Cost of labour, fixing & T&P shall be deemed to include in the quoted rate of this item. (iii) Unit rate quoted shall include for the necessary elelctrical check i.e checking of panel wiring to run the compressor smoothly. (iv) Before opening/ dismantling the compressor the freon gas to be taken in empty cylinder by the help Ice or as directed by Engineer-in-Charge.
Material and labour for rewinding of induction motor 2900 RPM, 3 phase, 50 Hz, 415 volt of compressor motor and AHU blower, chiller, condenser motor comprising of the following activities for induction motor of following capacities complete all as specified and as directed by Engr-in-charge. (i) Disconnecting and removing the electric motor from installed position and loading unloading, transporting to authorised/approved work shop. (ii) Dismantling existing burnt winding from the motor and rewinding complete with super enamelled copper winding wire of existing guage including all material such as insulated paper sleeves tape varnish etc complete for class F insulation and including shaft metalising, bearing cover slieving , necessary replacement of cooling fan, nut-bolt etc (iii) Loading, unloading and transporting motor & reinstalling in position and in alignment including electric conection commissioning and testing in actual working condition for 8 hours continuosly to check the performance on full load and designed RPM to the complete satisfaction of Engr-in-Charge all as specified and directed. (iv) M&L for replacement of 02 Nos of suitable size of ball bearing of existing size of the following type and capacity of induction motor.
Induction Motor of Capacity 50 HP
Induction Motor of Capacity 30 HP
Induction Motor of Capacity 15 HP
Induction Motor of Capacity 10 HP
Induction Motor of Capacity 7.5 HP
Induction Motor of Capacity 5 HP
Induction Motor of Capacity 3 HP
Induction Motor of Capacity 2 HP
Material and labour for repairs to leakages /damaged cooling coil by blocking/ by passing the corroded/ leakaged tube of DX coil, involving following activities:- (i) Removing the cooling coil from Air Handling unit and transport to the contractor /approved workshops. (ii) Leakage testing of the DX coil using nitrogen gas and finding the leakage tubes. (iii) Blocking/ By passing the leakaged copper tube and connect the copper tube with suitable new 'U' bends etc., by brazing. (iv) Straighten the fins of cooling coil using suitable brushes. (v) Painting of cooling coil with two coats of aluminium paint. (vi) Reasembling the cooling coil to the Air handling unit and again testing with nitrogen to the complete system for 08 hours for following capacity of the Air handling Units complete all as specified and as directed by Engr-in-charge.
2500 CFM to 5000 CFM
5500 CFM to 11000 CFM
12000 CFM to 18000 CFM
Above 18000 CFM and upto 25000 CFM
Material and labour for repairs to chiller of AC plant by blocking the damage/corroded tubes involving following activities:- (i) Disconnecting the side covers fo the chiller and the chiller valves from their existing positions. (ii) Leakage testing of the chilller using pressurized nitrogen gas and finding the leakaged tubes. (iii) Blocking the damaged /leaked tubes by brass plugs. (iv) Re-fixing the side covers of the chiller and the chiller valves from their existing positions with new nuts, bolts, rubber gasket and washer. (v) Testing the system for any leakage by using pressurized nitrogen gas and by vaccumising the system. (vi) Preparing the damage surfaces of chiller as per exisitng including repairs to damaged insulation and painting as per exisitng shade for following capacities of chillers complete all as specified and as directed by Engr-in-charge.
16 to 25 TR Capacity
26 to 50 TR capacity
51 to 90 TR capacity
Material and labour for repairs to condenser of AC plant by blocking the damaged/ corroded tubes involving following activities:- (i) Disconnecting the side covers of the condenser from their existing positions. (ii) Leakage testing of the condenser using pressurised nitrogen gas and finding the leaked tubes. (iii) Blocking the damaged /leaked tubes by brass plugs. (iv) Re-fixing the side covers of the condenser and the condenser valves from their existing positions with new nuts, bolts, rubber gasket and washers etc., and painting the surface with approved shade of synthetic enamel paints for following capacities of condenser complete all as specified and as directed by Engr-in-charge.
Upto 25 TR Capacity
26 to 50 TR capacity
51 to 130 TR capacity
Supply and fix for regenerable coarse type AHU filter of size 60cm x 60 cm x5 cm complete all as specified and as directed by Engr-in-charge.
Supply and fix for regenerable coarse type AHU filter of size 60cm x 50 cm x 5 cm complete all as specified and as directed by Engr-in-charge.
Supply and fix for regenerable coarse type AHU filter of size 60cm x 40 cm x 5 cm complete all as specified and as directed by Engr-in-charge.
Supply and fix for regenerable coarse type AHU filter of size 60cm x 30 cm x 5 cm complete all as specified and as directed by Engr-in-charge.
Supply and fixing in repair CI Non return valves PN 1 with matching flanges, hardware all as per IS:5312 of following sizes complete all as specified and as directed by Engr-in-charge.
50 mm bore
65 mm bore
80 mm bore
Supply and fixing in repair CI pot strainer/ Y strainer with matching flanges, gasket, hardware of following sizes complete all as specified and as directed by Engr-in-charge.
50 mm bore
65 mm bore
80 mm bore
Supply and fix in repairs protection caps made out of GI Sheet of thickness 1.6mm with three GI strip supports of size 25x3mm for fixing with the cooling tower including GI nuts and bolts for fixing complete all as specified and as directed by Engr-in-charge.
Material and labour for descaling of complete condenser units for central/ package type AC plants of following capacities by means of adding descaling chemical solution (HCL) or equivalent into the cooling tower sump as per requirements, and running the plant pump continuously till all the scale of pipes/shell are removed including removing side covers of condenser and cleaning the water tubes by means of nylon brushes till the scaling is removed and re fixing of covers including replacement of neoprene rubber gasket and refixing pipe connection etc., complete all as specified and as directed by Engr-in-charge.
Ccondenser unit of AC plant up to 60 TR
Condenser unit of AC plant 60 TR to 120 TR
Condenser unit of AC plant above 120 TR
Material and labour for repair of condenser pump/ chiler pump any type including replacement of impeler and bearings both side, replacement of main saft, outer body of the pump of following capacities complete all as specified and as directed by Engr-in-charge.
Chiler/condenser pump of Capacity 10 HP
Chiler/condenser pump of Capacity 7.5 HP
Chiler/condenser pump of Capacity 5 HP
Supply and fix in replacement MS ERW tubing medium grade 80mm dia for condenser water circulation pipes complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement MS ERW tubing medium grade 100mm dia for condenser water circulation pipes complete all as specified and as directed by Engr-in-charge.
Material and labour for nitrogen leak test entire system of the AC plant of Capacity upto 150 TR with Nitrogen gas. If found any leakage or reduction in the scale of pressure shall located and arrest the leakage immediately by soldering or an appropriate measure are to be taken to top the leakage permanently complete all as specified and as directed by Engr-in-charge.
Cleaning the cooling tower by applying wire brush, washing powder and other solvent by removing the deposited impurities sush as silt, dust particles mud/ sand inside the dume and around the fins,cleaning of base tray and grills, pot stainer, main shaft etc., and other connected items, servicing of fan motor including changing of bearings and greasing refixing the fan, frill and top cover including testing commissioning after reassembling complete including painting complete all as specified and as directed by Engr-in-charge.
Cooling tower of capacity up to 35 TR
Cooling tower of capacity 35 TR to 65 TR
Cooling tower of capacity 66 TR to 250 TR
Supply and fix in repairs of chilled water sensor as per existing make and type complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs strip heater finned 2 inch wide alluminised steel fins of 415 volt 1.5 to 3 KW capacity to match with the existing complete all as specified and as directed by Engr-in-charge.
Material and labour for thermal insulation to chilled water line, ducts, chillers, suction pipe with one coat of bituminous paint, polythelyne sheet, fiberglass wool insulation upto 50 mm thick, wiremesh and cover with 24 SWG aluminium clading complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs pressure gauge of range -30-150 complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs pressure gauge of range 0-200 complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs pressure gauge of range 0-300 complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs toggle switch of 5 Amp capacity complete all as specified and as directed by Engr-in-charge.
Supply and fix in repairs on-off push button pendants with elements red/green/orange complete all as specified and as directed by Engr-in-charge.
Supply and fix for rotational moulded polyethylene water storage tanks capacity 10000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position, taking down old unserviceable PVC tank complete all as specified and as directed by Engr-in-charge.
Supply and fix for rotational moulded polyethylene water storage tanks capacity 5000 Ltr (cylindrical vertical with closed top) hoisted and fixed in position, taking down old unserviceable PVC tank complete all as specified and as directed by Engr-in-charge.
Supply and fix in replacement V Belt complete all as specified and as directed by Engr-in-charge.
V Belt A-62
V Belt A-71
V Belt A-79
V Belt B-56
V Belt B-63
V Belt B-72
V Belt B-84
Supply, installation, commissioning and testing of factory made, CPRI type tested, indoor, cubical compartmental type HVAC panel in replacement of HVAC Panel Shivaji Auditorium AC Plant suitable size, conforming to IEC 61439-1 &2, IEC 61641, having both sides openable with hinged double doors and locking arrangement and IP 42 protection made out of 2mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labelling, painting to all internal and external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation (1:2:4) type B1, with danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal red colour, suitable for 3-Phase 4 wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length and size, including fixing lugs, bolts, screws etc., complete all as specified and as directed by Engr-in-charge. The HVAC panel shall comprise of the following: Busbar Chamber: INCOMER: (i) 01 Set (3L + N) of copper busbar of rated capacity 800 Amp, covered with PVC insulated sleeves including insulator, nuts, bolts, etc., with complete connection. Incoming: (i) 630 A, 415 V, ICS = 100% ICU = 36 kA, 50 Hz FP MCCB, conforming to IEC 60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5-10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm and Overload), etc.,- 01 Nos. (ii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts - 01 Nos. (iii) LED phase indicators (Red, Yellow, Blue) - 01 Set.
Outgoing: (i) 200 A, 415 V, Ics = Icu = 36 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lugs connectors and thermal magnetic trip unit (TMD)- 03 Nos. (for chillers) (ii) 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) and fixed magnetic settings with compression lugs connectors and thermal magnetic trip unit (TMD)- 01 Nos. (for AHU) (iii) 50 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 02 Nos. (for condensor pump) (iv) 32 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. (for cooling tower) (v) 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947- 2, 50 Hz, FP MCCB with adjustable thermal settings (0.70- 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD)- 01 Nos. (for Heater) (vi) LED phase indicators (Red, Yellow, Blue)- 12 Set (vii) Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Run hrs. On hrs & interupts - 12 Nos.
NOTES: (i) The panel shall be completely ethernet communication ready to communicate with energy management system and shall be web based application in-built. (ii) The Panel shall be with wireless energy sensor on incomer and outgoing feeders for monitoring (V, I, P, PF, Energy), voltage loss alarm, unbalance in phases. Same shall be communicated through Ethernet communication gateway to centralised Energy Monitoring System.
Material and labour for earthing complete with galvanized steel earth plate electrode of 600x600x6mm size, buried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to GI wire of 4mm diameter as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc., complete all as specified and as directed by Engr-in-charge. Notes: (i) The cost of GI earth continuity conductor with GI pipe 40mm medium grade upto 7.5m is deemed to be included in r/o above item. (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item.
Material and labour for earth contuinity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required GI wire of 4.0 mm diameter complete all as specified and as directed by Engr-in-charge.
Taking down defective /unserviceable air curtain (4 feet) of existing Make and capacity 1 to 1.5 m/sec air velocity at floor level, transporting to company authorized outlet, collecting company repaired air curtain of same make and transporting back to site, re-fixing at original position complete including testing and commissioning the machine onto the mounting plate and ensure the safety than fix it tighten with screw complete all as specified and as directed by Engr-in-charge.
Repair/ replacement of unserviceable blower moter, damaged blower, impillers unbalanced blower wheel of air curtain of capacity capacity 1 to 1.5 m/sec air velocity at floor level and remove, clean or replace air intake screen and filters of air curtain, obstruction in discharge path (i.e door headers, automatic door openers etc), check electrical connection, replace the fuse and servicing and overhauling complete unit complete all as specified and as directed by Engr-in-charge.
BRITE INDUSTRIES
JAVEED TRADERS
E M CONSTROL SYSTEM
M/s Vijay Airconditioning Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .