| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹79.7 LAccepted-Finance | L1 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 2 | L2₹93.4 L+₹13.7 L (17.3%)Accepted-Finance | L2 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 3 | L3₹97.0 L+₹17.3 L (21.7%)Accepted-Finance | L3 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 4 | L4₹97.5 L+₹17.8 L (22.3%)Accepted-Finance | L4 | Accepted-Finance TECHNICALLY AND FINANCIALLY QUALIFIED | |
| 5 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | TZ Engineering Works L2 | M/S KHAN ELECTRICAL ENTERPRISES L3 | SSF Construction And Supply Enterprises L1 | M/S Northern Electricals L4 |
|---|---|---|---|---|---|---|---|
| 1.0033KV LINE BAY/TRANSFORMER BAY Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of | |||||||
| 1.01 | 33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type) | 2 | No | 3,80,000 ₹7,60,000 | 3,30,000 ₹6,60,000 Lowest | 4,95,000 ₹9,90,000 | 4,22,000 ₹8,44,000 |
| 1.02 | 33kV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port | 1 | No | 3,50,000 ₹3,50,000 | 3,30,000 ₹3,30,000 | 3,40,000 ₹3,40,000 | 2,90,000 ₹2,90,000 Lowest |
| 1.03 | 33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port | 1 | No | 4,00,000 ₹4,00,000 | 4,30,000 ₹4,30,000 | 3,47,000 ₹3,47,000 Lowest | 4,30,000 ₹4,30,000 |
| 1.04 | 33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA) | 2 | No | 55,000 ₹1,10,000 | 40,000 ₹80,000 | 90,000 ₹1,80,000 | 28,000 ₹56,000 Lowest |
| 1.05 | 33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA) | 2 | No | 50,000 ₹1,00,000 | 40,000 ₹80,000 | 80,000 ₹1,60,000 | 27,000 ₹54,000 Lowest |
| 1.06 | 33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ) | 6 | No | 50,000 ₹3,00,000 | 20,000 ₹1,20,000 Lowest | 60,000 ₹3,60,000 | 55,555 ₹3,33,330 |
| 1.07 | 33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ) | 3 | No | 40,000 ₹1,20,000 Lowest | 45,000 ₹1,35,000 | 50,000 ₹1,50,000 | 55,555 ₹1,66,665 |
| 1.08 | 30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less | 9 | No | 12,000 ₹1,08,000 | 5,000 ₹45,000 Lowest | 30,000 ₹2,70,000 | 20,000 ₹1,80,000 |
| 1.09 | 33 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m | 9 | No | 2,000 ₹18,000 | 1,000 ₹9,000 Lowest | 3,000 ₹27,000 | 2,400 ₹21,600 |
Tender Value
₹99.5 L
EMD Value
₹2.0 L
Closing Date
13 Nov 2025, 2:00 pmClosed
EX ENGINEER STD PULWAMA
OFFICE OF THE EX ENGINEER STD PULWAMA
SITC of Electrical Equipments with structures for proposed 6.3 MVA Sub Station at Transit Camp Barsoo Awantipora
2025_PDD_291798_2
STD-PUL-NIT29 OF 2025-26
Open Tender
Electrical Works
Turn-key
60 days
SUB DIV AWANTIPORA
as per enit and sbd
2 documents required · 2 mandatory
₹2,000
Yes
EX ENGINEER STD PULWAMA
₹2.0 L
Yes
25 Nov 2025
18 Oct 2025
14 Nov 2025
18 Oct 2025
13 Nov 2025
18 Oct 2025
18 Oct 2025 - 8 Nov 2025
Amount
33KV LINE BAY/TRANSFORMER BAY Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of
33 kV VCB (36 kV, 1250A, 26.2 kA, Outdoor Type)
33kV C&R Panel along with O/C, E/F relays, mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps with RS-485 port, DLMS Compliant with RS-485 port
33 kV C&R Panel along with O/C, E/F and differential relays (IEC61850), mimic diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port
33 kV Isolator with Earthing Blade (36kV,1250A, Outdoor, 3 poles, 25 kA)
33 kV Isolator without Earthing Blade (36KV,1250A, Outdoor, 3 poles, 25 KA)
33 kV Current Transformer (33 kV, 1Φ, Multi Ratio Multi Core, Outdoor) (1 No. per Φ)
33 kV Voltage Transformer (33 kV/110 V, 1Φ, Multi-Core, Outdoor), (1No. per Φ)
30 kV Lightening Arrestors (30 kV, 10kA, Station class, ZnO, Polymer) gap less
33 kV Polymer Post Insulator 36kV,170kV Impulse, creepage distance 1224m
Nonimal Bore 200, 5.9 mm Thick
Galvanised Steel Structures
Galvanised Nuts & Bolts
12 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
6 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
4 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
2 Core 2.5 mm² Control cable copper Armoured , 1.1 kV Grade, ISI, FRLS.
Lugs, Ferrules etc.
200 mm² ACSR Conductor Panther
T Clamps
Single Tension Fittings
Polymeric composite Disc Insulator 36KV, Lightening Impulse 170kV Positive and 180kV Negative, creepage distance 900mm,min failing load 70kN
Earth wire 7/4.00 mm sq.
GI flat for earthing 50x6 mm
INDOOR SWITCHGEARS Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of
11 kV VCB Panel Board (12 kV, 1250A, 25 kA, Outdoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3- phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port scada compatible For 6.3 MVA (1+5)
11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type (4/5/6 Sets)
11 kV 630 mm² Single Core XLPE Cable (with one spare length) armoured, FRLS
11 kV 3-Core XLPE 300 mm² armoured, FRLS
11 kV Indoor Heat Shrinkable Cable Termination Kits
11 kV Outdoor Heat Shrinkable Cable Termination Kits
11 kV Indoor Heat Shrinkable Cable Termination Kits
11 kV Outdoor Heat Shrinkable Cable Termination Kits
11 kV Isolator, double break,3-pole, 600Amp, horizental mounting Type, with Earth Switch.
11 Mtr. Long Pole(ST-410 SP56)
G.I Pipe of Dia 150mm, 5.9 mm Thick 11' long (12 No.s) with G.I Base & top Plate 8 mm Thick using grouting /dash fasteners
Galvanised Steel Structures
Galvanised Nuts & Bolts
AUXILLARY SUPPLY EQUIPMENTS FOR STATION Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of
100 kVA,33/0.433 kV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Copper wound)
9 Mtr. Long Pole (ST-410 SP33)
33 kV, Lightening Arrestor,(33 kV ,10 kA ,Station class,ZnO, Polymer) gapless
33 kV GO swtch (36kV,800 A, Outdoor ,3 poles,25 kA).
33 kV Horn Gap Fuse set
Galvanised iron of sorts
Galvanized Nuts & Bolts of sizes
95 mm² XLPE LT Cable 1 Core, armoured, FRLS
Cement bottoming 1:2:4 mix as per Standards 0.48 cum per pole
Earthing of 100 kVA SubStation--Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Earthing Complete by GI Pipe 40 mm 3 mtr long through GI Strip 25x3mm
Red Oxide
Aluminium Paint
MCCB ‐ 160 Amps , 36 kA, 4P Ics=100% Icu at 415 (kA rms)
a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply including 4 way DC connector with MCB
Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
Yard lightening Supply,Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of
Yard Lighting by way of Providing 9 Mtr long ST poles (ST410 SP33) with 2 No.s of 100 W LED flood lights on each pole complete with earthing , and cement bottoming (1:2:4) of 0.48 cum,earthing,painting incl all power cable/wiring acessories and MCB complete in all respects and Providing and fixing of Arms – To be made from M. S. Pipe (approx. 1500 mm long) of suitable diameter, welded with the cap (supported by suitable stiffener plate), keeping suitable opening for cable entry incl connection of lights with 25 sqmm multi stranded FRLS with upto termination box
Yard Lighting by way of Providing 8 Mtr long ST poles (ST410 SP33) with 2 No.s of 101 W LED flood lights on each pole complete with earthing , and cement bottoming (1:2:4) of 0.4 cum earthing,painting incl all power cable/wiring acessories and MCB complete in all respects and Providing and fixing of Arms – To be made from M. S. Pipe (approx. 1500 mm long) of suitable diameter, welded with the cap (supported by suitable stiffener plate), keeping suitable opening for cable entry.
10 mm² Cable (2C) from LT Line to meter ,1.1k V Grade, Armoured, XLPE FRLS type for yard lightening to be laid in HDPE
Providing and laying of 2.5 Sq.mm 3-core copper flexible cable to laid in HDPE pipe from source to pole terminations boxes including fixing of thimbals/Lugs and cable glads.
Providing and laying of HDPE 40mm pipe underground by way of excavation upto 1 feet in all type of soil and backfilling the cavity after laying of pipe.
Providing and fixing of Static automatic light control circuits Ip-66 rated including testing and commissioning complete
Installation of Power Transformer Loading, Transportation, insurance, Unloading, Carriage and Delivery at Site including installation,Testing and Commissioning of
33KV/11KV 6.3 MVA Power Transformer (To be provided by Deptt from Central Store Div Pampore)
Providing of T&P/Safety Equipment Items
Supply of CO2 type Fire Extinguishers of 6.8Kg capacity fitted with trolley, delivery hose horn, wheel type release value etc (complete) class C
Supply of tool kit as per IS standard with latest amendments suitable for Job
Supply of manually operated crimping tool of 3D or dowels make
Supply of aluminium ladder 40ft long, folded type (5-6mm thick) with rope and pully complete
Safety shoes (insulated, anti-slip)
Arc flash suit / Flame-retardant clothing for Arc protection during switching
Electrical safety gloves (Class 2 or above)
Safety helmet (insulated type) as per standard with latest amendments
Reflective jacket for Visibility within yard
Discharge rod / Earthing rod as per standard with latest amendments
Operating rod (insulated link stick)
Rubber mat (11 kV rated) (2x6)ft 10mm
Supply and installation of Sand Bucket Stand fabricated from MS angle iron (40×40×5 mm) suitable for hanging four (4) nos. MS sand buckets, each of 9–10 litre capacity, painted red and marked “SAND” in white letters, filled with clean dry river sand, including protective canopy, sign board, and all accessories complete and direction of Engineer-in-Charge. Unit: Each Set (4 buckets + stand + sand + signage)
Danger boards (“33 kV / 11 kV – Danger Danger”)
Safety goggles / face shield
TZ Engineering Works (BID ID -2630991)
M/S KHAN ELECTRICAL ENTERPRISES (BID ID -2632653)
M/S Northern Electricals (BID ID -2632584)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.17 MB
GTP.pdf
Other Document • 0.47 MB
BOQ_944150.xls
BOQ • 0.31 MB
SBD29.pdf
Tender Documents • 1.65 MB
33KVequipmentSpecifications.pdf
Other Document • 5.85 MB
EQUIPMENTFOUNDATION.pdf
Other Document • 5.97 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .