Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹2.3 LQualified Make: Matrix
Model: MATRIX ETERNITY GENX12SAC 4*16*24 15 19 GIDC WAGHODIA N | Make: Matrix
Model: MATRIX ETERNITY GENX12SAC 4*16*24 | ₹2.3 L | L1 | Qualified |
| 2 | Disqualified Make: Panasonic
Model: PANASONIC KX NS300SX B3 NANDKISHOR INDUSTRIAL ESTATE MAHAKALI CAVES ROAD NEAR PAPER BOX ANDHERI EAST MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | Make: Panasonic
Model: PANASONIC KX NS300SX | - | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
28 May 2018, 3:00 pmClosed
pabx system-EPABX Average Turn Over of Last 3 Years 8000 Lakh (s) Experience with Gov. Required 10 Year (s) Pabx System-EPABX ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based )
Hybrid ( Microprocessor based also supporting SIP extension )
Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 24 24
48
64
96
128
160
1 92
224
256
320
384
44 8
576
704
832
960
108 8
1600
2112
2624
313 6
3648
4160
4672
0 Expandable Upto (TDM/FSX Ports) 128 128
512
1024
129 6
1500
1800
2048
400 0
6000
NA Number of Digital Extensions 16 4
8
16
24
32
NA Number of Analogue Junction/FXO ports 4 4
12
NA Number of SIP Extensions 64 4
25 6
4096
NA 1/11 SIP Extensions expandable upto 256 32
102 4
800 0
NA Number of SIP Trunks NA 4
NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) NA 50
100
200
400
600
10 00
2000
3000
4000
50 00
NA Integrated Protection Module(IPM) false If YES
number of Integrated Protection Module(IPMs) NA 50
NA CARDS CARDS Type of Cards Supported BRI
PRI
E1
E&M
Radio Interface
GSM BRI
GSM
NA Number of Ports per Card Supported NA 1
2
4
6
NA GATEWAYS Type of Gateways Supported Universal Gateway
SIP
FXO
FXS
Radio
E&M - Number of Ports per Gateway Supported 4 - CONSOLE Type of Operator Console Key phone based PC based
Key phone based
Server Based
NA Number of Operator Console 1 1
6 4
NA SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA 1
3
5
7
9
10
11
NA "Number of Hot Standby Servers out of Total Servers
included in the Scope of Supply" 0 - Server Form Factor Rack - Rack Size (RU)/Space Required for each Server 4 - Processor Make AMD - Processor Configuration & Description 32 BIT RISC PROCESSOR - Total Number of processor NA 1
NA Number of Redundant Processors Included in the Total Number NA 1
NA 2/11 of Processor Number of Cores per Processor NA 2
14
18
20
22
26
28
30
N A Type of RAM DDR3 - RAM Size (in GB) NA 4
N A T ype of Hard Disk Drive NA - Capacity of Hard Disk Drive (in TB) NA 1
NA Hot Swap Components Power Supply Unit
Fans
HDD Power Supply Unit
HDD
NA Network Interface Integrated Dual Gigabit(auto) Ethernet supporting IPv4 and IPv 6
USB
HDMI
VGA
WiFi - SOFTWARES Applcation Software Type/Capabilities Call Server Software
Hot StandBy Server Software
Unified Communication Server Software
Network Management Server Software Call Server Software
Network Management Server Software
NA Type of Licence Perpetual Perpetual
Subscription Based
NA Name of Softwares SARVAM UCS ENT - Name of the OEM MATRIX - OEM Model/Part Number ETERNITY GE - Software Description CALL SERVER SOFTWARE - Software Version V1R5 - Date of Launch of Version 2018 - Free supports/updates during validity of license YES - SOFTWARE FEATURES Analog Extention/FXS ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under YES YES
NO
NA ( For Convensional PBX ) 3/11 ""EXTENSION AND TRUNK/JUNCTION"" ) "Digital Extension ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "Analog Junction/FXO ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "SIP extension ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "SIP trunk ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "PRI Trunk ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) 4/11 "Radio Interface ( If Yes
Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "GSM ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "E1 Trunk ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NA ( For Convensional PBX ) "E&M ( If Yes
Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES
NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 16 8
NA Number of Direct Station Selection Keys per Console 16 - Number of Media Channel/Ports Supported 128 8
NA Number of IP-TDM Concurrent Calls(2 users per call) Supported 128 4
550
NA Call Buffer Memory true 5/11 System If Call Buffer Memory Available
Number of Records 2000 100
250
500
1000
200 0
NA Hot Standby Redundant CPU false If YES
Number of Hot Standby CPU Cards NA 1
NA Hot Standby Redundant PSU (Power Supply Unit) false If YES
Number of Hot Standby Redundant PSU Cards NA 1
NA Inbuilt Voice Mail for EPABX System true If Voice Mail Available
Number of Voice Mail Channels 16 4
NA Available for Voice Mail
Number of Hours of Recording 4 4
5 12
NA Auto Attendant Facility true - If Available
Number of Auto Attendant Channels 4 - ASMDR/CDR true Voice Logger NA Inbuilt
Inbuilt External Connecting facility
NA If YES
Number of Simultaneous Calls that can be Recorded in Voice Logger NA - Security Feature(for server based) MD-5
Radius authentica tion
802.1X
SRTP - Supported Functionalities (for server based) UCS
LDAP
NMS - Supported Codecs G711
G729
G723
H264
VP8 - Any other features IP at core
universal slots
expandable up to 240 TDM & 999 SIP users
21 party audio conference. - SYSTEM/EXTENSION/AT System Features Automatic Route Automatic Route 6/11 TENDANT CONSOLE FEATURES Selection facility
DID facility(Direct inward dialing)
DOD facility(Direct outward dialing)
DISA facility(Direct inward station access)
DOSA facility(Direct outwards station access)
Multi Level Voice DISA facility
Privacy of Call
Facility for connecting recorded voice answering
ASMD R/CDR
Programmable class of service for (STD/ISD/LOCAL) dialing as per need
Caller ID information for both internal and external callers (over Analogue
ISDN PRI)
unique authorization codes for every users
Automatic call back
Call waiting
Music-on-hold facility
Call budgeting
Least cost routing
Mix-mode dialing
Provision for remote logins
Interactive Voice Response System(IVRS)
Extensio n to Extension dialing Selection facility
Extensio n to Extension dialing Extension Features Call forwarding
Consultatio n Hold
Brokers Call
Automatic call transfer
Conference call
Call pick up
Call re routing
Auto call disconnection
Dynamic STD Lock
Paging on key phone
Background music
Password control
Virtual Telephony
Howler Tone
Call parking
Auto answer/Auto off
Emergency call facili ty
Missed/Dialed/Receiv ed Call Lists
Last Caller Call back
Password display suppression
Personal Call forwarding
Personal 7/11 Identification Number
Hotline
Preset Conference Calls
Direct Call billing in rupees
Call billing printout
Calling line ide ntification(CLI)
Remote Maintenance
Other Extension features Identification Number
Other Extension features Attendant Console Features Answering an incoming call
Call queuing
Serial Call
Call waiting display
Automatic Call Distribution
Call Hold
Trunk offering
Night service
Head phone connectivity
Other Attendants console Features Answering an incoming call
Other Attendants console Features Voice Prompts and Announcement true - If yes
Number of Levels of IVRS NA 1
NA POWER SOURCE Supply Voltage 230V AC
50HZ 230V AC
50HZ
48V DC
NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup NO - FCBC NA YES
minimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA 10A
12.5A
25A
50A
NA Protection against over current and accidental reversal of polarity on the input side and against over current
over voltage on the output side YES - OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10
0
10 Maximum Operating Temperature (Degree C) 45 35
40
45
50
55 Operating Humidity (RH) (% ) 95 80
85
90
95 8/11 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES - TEC approval Certificate number TEC/WR/I/PBX-004/03/1 22.DEC.17 DATED 19.12.2017 - Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence true - Test Report Number and date (not a part of biddable parameter) RP-1516-045698 DATED 29.02.2016 - Name and Address of the Test lab(not a part of biddable parameter) - - Test reports consist of verification of all the features & functional parameters & environmental tests true - conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true INSTALLATION AND MAINTENANCE Installation and Commissioning With With
Without Chemical Earthing to achieve resistance < 2ohm false 9/11 Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System PROPER VENTILATED SPACE TO EPABX. - OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES - Operation & Maintenance terminal Provided - Training provided to buyers true If YES
Details of training On site training for 3 days On site training for 3 days
On site training for 5 days
NA Packing List ETERNITY GENX12SAC-1 WITH 24 SLT
4CO
16DKP
PSU
CPU
SERVICES Warranty 1 1
10 Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System
PROPER VENTILATED SPACE TO EPABX. - Compliance to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Daniel Raj F 400093
EXPORT INSPECTION AGENCY - MUMBAI E - 3
MIDC Andheri 1 15 EMD Required No ePBG Required No 10/11
104994
GEM/2018/B/14982
pabx system-EPABX
15 days
Maharashtra; Mumbai Suburban
PRODUCT
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| pabx system-EPABX Average Turn Over of Last 3 Years 8000 Lakh (s) Experience with Gov. Required 10 Year (s) Pabx System-EPABX ( 1 ) Technical Specifications Specification Specification Name Values Allowed Values EXTENSION AND TRUNK/JUNCTION EPABX system Implementation Tech nology/Architecture Hybrid ( Microprocessor based also supporting SIP extension ) Conventional ( Card/microcontroller based ) | - | - | - |
| Hybrid ( Microprocessor based also supporting SIP extension ) | - | - | - |
| Server Based ( Switching through Call Server Application ) Number of Analogue Extensions/FXS Ports 24 24 | - | - | - |
| 48 | - | - | - |
| 64 | - | - | - |
| 96 | - | - | - |
| 128 | - | - | - |
| 160 | - | - | - |
| 1 92 | - | - | - |
| 224 | - | - | - |
| 256 | - | - | - |
| 320 | - | - | - |
| 384 | - | - | - |
| 44 8 | - | - | - |
| 576 | - | - | - |
| 704 | - | - | - |
| 832 | - | - | - |
| 960 | - | - | - |
| 108 8 | - | - | - |
| 1600 | - | - | - |
| 2112 | - | - | - |
| 2624 | - | - | - |
| 313 6 | - | - | - |
| 3648 | - | - | - |
| 4160 | - | - | - |
| 4672 | - | - | - |
| 0 Expandable Upto (TDM/FSX Ports) 128 128 | - | - | - |
| 512 | - | - | - |
| 1024 | - | - | - |
| 129 6 | - | - | - |
| 1500 | - | - | - |
| 1800 | - | - | - |
| 2048 | - | - | - |
| 400 0 | - | - | - |
| 6000 | - | - | - |
| NA Number of Digital Extensions 16 4 | - | - | - |
| 8 | - | - | - |
| 16 | - | - | - |
| 24 | - | - | - |
| 32 | - | - | - |
| NA Number of Analogue Junction/FXO ports 4 4 | - | - | - |
| 12 | - | - | - |
| NA Number of SIP Extensions 64 4 | - | - | - |
| 25 6 | - | - | - |
| 4096 | - | - | - |
| NA 1/11 SIP Extensions expandable upto 256 32 | - | - | - |
| 102 4 | - | - | - |
| 800 0 | - | - | - |
| NA Number of SIP Trunks NA 4 | - | - | - |
| NA MAIN DISTRIBUTION FRAME(MDF) MDF(Number of pair) NA 50 | - | - | - |
| 100 | - | - | - |
| 200 | - | - | - |
| 400 | - | - | - |
| 600 | - | - | - |
| 10 00 | - | - | - |
| 2000 | - | - | - |
| 3000 | - | - | - |
| 4000 | - | - | - |
| 50 00 | - | - | - |
| NA Integrated Protection Module(IPM) false If YES | - | - | - |
| number of Integrated Protection Module(IPMs) NA 50 | - | - | - |
| NA CARDS CARDS Type of Cards Supported BRI | - | - | - |
| PRI | - | - | - |
| E1 | - | - | - |
| E&M | - | - | - |
| Radio Interface | - | - | - |
| GSM BRI | - | - | - |
| GSM | - | - | - |
| NA Number of Ports per Card Supported NA 1 | - | - | - |
| 2 | - | - | - |
| 4 | - | - | - |
| 6 | - | - | - |
| NA GATEWAYS Type of Gateways Supported Universal Gateway | - | - | - |
| SIP | - | - | - |
| FXO | - | - | - |
| FXS | - | - | - |
| Radio | - | - | - |
| E&M - Number of Ports per Gateway Supported 4 - CONSOLE Type of Operator Console Key phone based PC based | - | - | - |
| Key phone based | - | - | - |
| Server Based | - | - | - |
| NA Number of Operator Console 1 1 | - | - | - |
| 6 4 | - | - | - |
| NA SERVER SPECIFICATIONS REQUIREMENTS Total Number of Servers Included in the Supply NA 1 | - | - | - |
| 3 | - | - | - |
| 5 | - | - | - |
| 7 | - | - | - |
| 9 | - | - | - |
| 10 | - | - | - |
| 11 | - | - | - |
| NA "Number of Hot Standby Servers out of Total Servers | - | - | - |
| included in the Scope of Supply" 0 - Server Form Factor Rack - Rack Size (RU)/Space Required for each Server 4 - Processor Make AMD - Processor Configuration & Description 32 BIT RISC PROCESSOR - Total Number of processor NA 1 | - | - | - |
| NA Number of Redundant Processors Included in the Total Number NA 1 | - | - | - |
| NA 2/11 of Processor Number of Cores per Processor NA 2 | - | - | - |
| 14 | - | - | - |
| 18 | - | - | - |
| 20 | - | - | - |
| 22 | - | - | - |
| 26 | - | - | - |
| 28 | - | - | - |
| 30 | - | - | - |
| N A Type of RAM DDR3 - RAM Size (in GB) NA 4 | - | - | - |
| N A T ype of Hard Disk Drive NA - Capacity of Hard Disk Drive (in TB) NA 1 | - | - | - |
| NA Hot Swap Components Power Supply Unit | - | - | - |
| Fans | - | - | - |
| HDD Power Supply Unit | - | - | - |
| HDD | - | - | - |
| NA Network Interface Integrated Dual Gigabit(auto) Ethernet supporting IPv4 and IPv 6 | - | - | - |
| USB | - | - | - |
| HDMI | - | - | - |
| VGA | - | - | - |
| WiFi - SOFTWARES Applcation Software Type/Capabilities Call Server Software | - | - | - |
| Hot StandBy Server Software | - | - | - |
| Unified Communication Server Software | - | - | - |
| Network Management Server Software Call Server Software | - | - | - |
| Network Management Server Software | - | - | - |
| NA Type of Licence Perpetual Perpetual | - | - | - |
| Subscription Based | - | - | - |
| NA Name of Softwares SARVAM UCS ENT - Name of the OEM MATRIX - OEM Model/Part Number ETERNITY GE - Software Description CALL SERVER SOFTWARE - Software Version V1R5 - Date of Launch of Version 2018 - Free supports/updates during validity of license YES - SOFTWARE FEATURES Analog Extention/FXS ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of Analog Extension/FXS Offered under YES YES | - | - | - |
| NO | - | - | - |
| NA ( For Convensional PBX ) 3/11 ""EXTENSION AND TRUNK/JUNCTION"" ) "Digital Extension ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of Digital Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "Analog Junction/FXO ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of Analog Junction/FXO Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "SIP extension ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of SIP Extension Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "SIP trunk ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "PRI Trunk ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of PRI Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) 4/11 "Radio Interface ( If Yes | - | - | - |
| Number of Software/Licences shall be Commensurate Equal to the Number of Radio Interface Offered under ""EXTENSION AND TRUNK/JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "GSM ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of GSM Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "E1 Trunk ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of E1 Trunk Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NA ( For Convensional PBX ) "E&M ( If Yes | - | - | - |
| Number of Software Licences shall be Commensurate Equal to the Number of E&M Offered under ""EXTENSION AND TRUNK JUNCTION"" )" YES YES | - | - | - |
| NO GENERAL FEATURES of EPABX SYSTEM Number of Conference Participants Supported 16 8 | - | - | - |
| NA Number of Direct Station Selection Keys per Console 16 - Number of Media Channel/Ports Supported 128 8 | - | - | - |
| NA Number of IP-TDM Concurrent Calls(2 users per call) Supported 128 4 | - | - | - |
| 550 | - | - | - |
| NA Call Buffer Memory true 5/11 System If Call Buffer Memory Available | - | - | - |
| Number of Records 2000 100 | - | - | - |
| 250 | - | - | - |
| 500 | - | - | - |
| 1000 | - | - | - |
| 200 0 | - | - | - |
| NA Hot Standby Redundant CPU false If YES | - | - | - |
| Number of Hot Standby CPU Cards NA 1 | - | - | - |
| NA Hot Standby Redundant PSU (Power Supply Unit) false If YES | - | - | - |
| Number of Hot Standby Redundant PSU Cards NA 1 | - | - | - |
| NA Inbuilt Voice Mail for EPABX System true If Voice Mail Available | - | - | - |
| Number of Voice Mail Channels 16 4 | - | - | - |
| NA Available for Voice Mail | - | - | - |
| Number of Hours of Recording 4 4 | - | - | - |
| 5 12 | - | - | - |
| NA Auto Attendant Facility true - If Available | - | - | - |
| Number of Auto Attendant Channels 4 - ASMDR/CDR true Voice Logger NA Inbuilt | - | - | - |
| Inbuilt External Connecting facility | - | - | - |
| NA If YES | - | - | - |
| Number of Simultaneous Calls that can be Recorded in Voice Logger NA - Security Feature(for server based) MD-5 | - | - | - |
| Radius authentica tion | - | - | - |
| 802.1X | - | - | - |
| SRTP - Supported Functionalities (for server based) UCS | - | - | - |
| LDAP | - | - | - |
| NMS - Supported Codecs G711 | - | - | - |
| G729 | - | - | - |
| G723 | - | - | - |
| H264 | - | - | - |
| VP8 - Any other features IP at core | - | - | - |
| universal slots | - | - | - |
| expandable up to 240 TDM & 999 SIP users | - | - | - |
| 21 party audio conference. - SYSTEM/EXTENSION/AT System Features Automatic Route Automatic Route 6/11 TENDANT CONSOLE FEATURES Selection facility | - | - | - |
| DID facility(Direct inward dialing) | - | - | - |
| DOD facility(Direct outward dialing) | - | - | - |
| DISA facility(Direct inward station access) | - | - | - |
| DOSA facility(Direct outwards station access) | - | - | - |
| Multi Level Voice DISA facility | - | - | - |
| Privacy of Call | - | - | - |
| Facility for connecting recorded voice answering | - | - | - |
| ASMD R/CDR | - | - | - |
| Programmable class of service for (STD/ISD/LOCAL) dialing as per need | - | - | - |
| Caller ID information for both internal and external callers (over Analogue | - | - | - |
| ISDN PRI) | - | - | - |
| unique authorization codes for every users | - | - | - |
| Automatic call back | - | - | - |
| Call waiting | - | - | - |
| Music-on-hold facility | - | - | - |
| Call budgeting | - | - | - |
| Least cost routing | - | - | - |
| Mix-mode dialing | - | - | - |
| Provision for remote logins | - | - | - |
| Interactive Voice Response System(IVRS) | - | - | - |
| Extensio n to Extension dialing Selection facility | - | - | - |
| Extensio n to Extension dialing Extension Features Call forwarding | - | - | - |
| Consultatio n Hold | - | - | - |
| Brokers Call | - | - | - |
| Automatic call transfer | - | - | - |
| Conference call | - | - | - |
| Call pick up | - | - | - |
| Call re routing | - | - | - |
| Auto call disconnection | - | - | - |
| Dynamic STD Lock | - | - | - |
| Paging on key phone | - | - | - |
| Background music | - | - | - |
| Password control | - | - | - |
| Virtual Telephony | - | - | - |
| Howler Tone | - | - | - |
| Call parking | - | - | - |
| Auto answer/Auto off | - | - | - |
| Emergency call facili ty | - | - | - |
| Missed/Dialed/Receiv ed Call Lists | - | - | - |
| Last Caller Call back | - | - | - |
| Password display suppression | - | - | - |
| Personal Call forwarding | - | - | - |
| Personal 7/11 Identification Number | - | - | - |
| Hotline | - | - | - |
| Preset Conference Calls | - | - | - |
| Direct Call billing in rupees | - | - | - |
| Call billing printout | - | - | - |
| Calling line ide ntification(CLI) | - | - | - |
| Remote Maintenance | - | - | - |
| Other Extension features Identification Number | - | - | - |
| Other Extension features Attendant Console Features Answering an incoming call | - | - | - |
| Call queuing | - | - | - |
| Serial Call | - | - | - |
| Call waiting display | - | - | - |
| Automatic Call Distribution | - | - | - |
| Call Hold | - | - | - |
| Trunk offering | - | - | - |
| Night service | - | - | - |
| Head phone connectivity | - | - | - |
| Other Attendants console Features Answering an incoming call | - | - | - |
| Other Attendants console Features Voice Prompts and Announcement true - If yes | - | - | - |
| Number of Levels of IVRS NA 1 | - | - | - |
| NA POWER SOURCE Supply Voltage 230V AC | - | - | - |
| 50HZ 230V AC | - | - | - |
| 50HZ | - | - | - |
| 48V DC | - | - | - |
| NA Provision for Inbuilt Battery Charging Arrangement for providing Battery Backup NO - FCBC NA YES | - | - | - |
| minimum current Rating of FCBC at chrging voltage of 48V (Ampere) NA 10A | - | - | - |
| 12.5A | - | - | - |
| 25A | - | - | - |
| 50A | - | - | - |
| NA Protection against over current and accidental reversal of polarity on the input side and against over current | - | - | - |
| over voltage on the output side YES - OPERATING CONDITIONS Minimum Operating Temperature (Degree C) 0 10 | - | - | - |
| 0 | - | - | - |
| 10 Maximum Operating Temperature (Degree C) 45 35 | - | - | - |
| 40 | - | - | - |
| 45 | - | - | - |
| 50 | - | - | - |
| 55 Operating Humidity (RH) (% ) 95 80 | - | - | - |
| 85 | - | - | - |
| 90 | - | - | - |
| 95 8/11 TEST REPORT DETAILS AND TESTS TEC approval as per the latest TEC specifications YES - TEC approval Certificate number TEC/WR/I/PBX-004/03/1 22.DEC.17 DATED 19.12.2017 - Availability of the test report from Central Government/NABL ILAC acredited lab to prove conformity to the specification including Environmental Test Sequence true - Test Report Number and date (not a part of biddable parameter) RP-1516-045698 DATED 29.02.2016 - Name and Address of the Test lab(not a part of biddable parameter) - - Test reports consist of verification of all the features & functional parameters & environmental tests true - conformity to Dry Heat for 16 hours at maximum specified temperature degree C in accordance with IS:9000/part-3/sectio n-5/1977 latest true conformity to Cold Test for 4 hours at minimum specified temperature degree C in accordance with IS:9000/part-2/sectio n-4/1977 latest true conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 h each at a temperature of 40 degree C & 95% RH in accordance with IS:9000/part-5/s ection-1/1991 latest true INSTALLATION AND MAINTENANCE Installation and Commissioning With With | - | - | - |
| Without Chemical Earthing to achieve resistance < 2ohm false 9/11 Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System PROPER VENTILATED SPACE TO EPABX. - OPERATION & MAINTENANCE SUPPORT The scope of supply include one set of operation and maintenance manual for each equipment YES - Operation & Maintenance terminal Provided - Training provided to buyers true If YES | - | - | - |
| Details of training On site training for 3 days On site training for 3 days | - | - | - |
| On site training for 5 days | - | - | - |
| NA Packing List ETERNITY GENX12SAC-1 WITH 24 SLT | - | - | - |
| 4CO | - | - | - |
| 16DKP | - | - | - |
| PSU | - | - | - |
| CPU | - | - | - |
| SERVICES Warranty 1 1 | - | - | - |
| 10 Recommendation Information regarding Supporting Hardware Required to meet the Performance Capabilities of the System | - | - | - |
| PROPER VENTILATED SPACE TO EPABX. - Compliance to STC of the Product Yes - * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Daniel Raj F 400093 | - | - | - |
| EXPORT INSPECTION AGENCY - MUMBAI E - 3 | - | - | - |
| MIDC Andheri 1 15 EMD Required No ePBG Required No 10/11 | - | - | - |
Exempted
1 Jun 2018
18 May 2018
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_104994.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .