| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹82,420Accepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹83,680+₹1,260 (1.53%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹86,589
EMD Value
₹1,732
Closing Date
8 Feb 2023, 9:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
EE, EandM Division, APWD, Prothrapur
Construction of Shop for Ongees at Dugong Creek Little Andaman SW Providing IEI
2023_APWD_9083_1
NIT No 13/EE/EandM/22-23 3rd Call
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹1,732
3 Mar 2023
30 Jan 2023
8 Feb 2023
30 Jan 2023
8 Feb 2023
4 Feb 2023
31 Jan 2023 - 3 Feb 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. a) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Supplying and fixing metal box of 150 mm X 75 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required.
Supplying and fixing metal box of 180 mm X 100 mm X 60 mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 A & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing of Surface mounted LED Batten fitting for 20 Watt T-8 Lamp similar to Havells Cat No. LHFYBYPNIA1W022 and LED20W Lamp similar to Cat No. C&S Cat NO. LT4F20WLEDT8/WD or its equivalent. etc., as required.
Supplying and Fixing of LED Bulkhead : e- TARA SERIES a utility suitable for indoor and outdoor applications similar to C&S Cat No. CG80IB10WLED 10 Watt or its equivalent. etc., as required.
Supplying of AC Ceiling Fan (1200 mm) Sweep ISI Marked 5 Star rated i/c down rod of standard length 30 cm with all accessories similar to Havells ES - 50 or its equivalent. etc., as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) a) 2 + 8 Way, Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2000mm, outer dia 50 mm, inner dia 25 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Providing and fixing hot press moulded SMC Meter Box of Size 350 x 250 x 150 mm for accommodating one LT Single Phase KWh meter with cut out similar to make sintex cat No. GSJB 3525 or its equivalent. etc., as required.
DAYAL HALDER
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .