Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹5.8 LAdmitted-Finance | -41.25% | ₹5.8 L | L1 | Admitted-Finance |
| 2 | L2₹6.1 LAdmitted-Finance | -38.90% | ₹6.1 L | L2 | Admitted-Finance |
| 3 | L3₹6.9 LAdmitted-Finance WZ 66 SRI NAGAR RANI BAGH NORTH WEST DELHI DELHI 110034 | NORTH WEST DELHI | DELHI | 110034 | -30.52% | ₹6.9 L | L3 | Admitted-Finance |
| 4 | L4₹9.6 LAdmitted-Finance A 23 KUNJ VIHAR SOCIETY SHREE KRISHNA NAGAR SAKINAKA ANDHERI E MUMBAI 400 072 | MUMBAI | MUMBAI | MAHARASHTRA | 400072 | -3.30% | ₹9.6 L | L4 | Admitted-Finance |
Tender Value
₹9.9 L
EMD Value
₹19,846
Closing Date
18 Dec 2025, 1:00 pmClosed
Executive Engineer
12, Cavalry Lane, Engineering Department, University of Delhi, Delhi-110007
Electrical work to be carried out in room no. 9, 10, 11, 12, 13 (Central Store room) etc. and other allied work at Administrative Block University of Delhi
2025_DU_888788_1
CEET-7138
Open Tender
Electrical Works
20 days
North Campus
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
Registrar, University of Delhi
₹19,846
20 Jan 2026
6 Dec 2025
19 Dec 2025
6 Dec 2025
18 Dec 2025
6 Dec 2025
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel / PVC conduit as required.
3x2.5 sqmm
3x4 sq.mm
3x6 sq.mm
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.
3 Module (100mmX75mm)
6 Module (200mmX75mm)
12 Module (200mmX150mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
3 pin 5/6 amp socket outlet
15/16 amp switch
6 pin 15/16 amp socket outlet
Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connections, painting etc. as required.
Supply, installation, testing and commissioning of ceiling fan with Brush Less Direct Current (BLDC) Moter, Class of Insulation: B, 3 Nos. metal (Aluminium alloy) Blades, 30 cm long down rod, 2 nos. conopies, shackle kit, safety rope, copper winding, steel/ Al body power Factor not less than 0.9, service Value (CMM/W) minimum as below 350 RPM (Tolerance as per IS:374-2019), THD (Total Harmonic Distortion ) less than 10%, suitable for operstion with regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temprature rise= 75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230V, 50 Hz, single phase AC ceiling fan compliant to IS : 374: 019 fan supply, earthing complete as required.
1400mm, service value > 6.0 CM/Min./ Watt, air delivery 245 CM/ Min (Minimum)
Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. Group B
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and fixing of following sizes of Heavy class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
20 mm dia.
25 mm dia.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)12 way (4 + 36), double door
2.10 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps 4 pole
Providing and fixing 125 amps, 16 KA, TP MCCB with thermomagnetic release and terminal spreaders in existing cubical panel board including drilling holes in cubical panel, making connections, etc. as required.
Supplying and fixing 2 Module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed heavy class PVC conduit as required 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required 3.5c X 300 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of XLPE insulated and PVC sheathed aluminium conductor cable of 1.1 KV grade as required. 3.5c X 300 sq. mm
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Above 185 sq. mm and upto 400 sq. mm
Providing and fixing 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
Supply, installation, testing and commissioning of pre-wired, single box type fitting with one no. LED tube of frosted cover design, 18 watts, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/ wall , including connection with 1.5 sq.mm FRLS PVC insulated , copper conductor cable and earthing etc. as required. fitting equivalent to Philips make, CAT No. TPM 502 1xT- LED 22W. Tube equivalent to Philips make, CAT No. MAS LED tube 1200mm 18W 865 T81-2100lm
Supply, installation, testing and commissioning of one no. LED tube of frosted cover design,18Watts, 2100lm, 50000 burning hours, size 1200mm in existing single box or double box fitting complete as required, tube equivalent to Philips make, Cat No. MAS LED tube 1200 mm 18W 856 T8I 2100lm
Supply, installation, testing and commissioning of pre-wired, double box type fitting with one no. LED tube of frosted cover design, 18 watts, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/ wall , including connection with 1.5 sq.mm FRLS PVC insulated , copper conductor cable and earthing etc. as required. fitting equivalent to Philips make, CAT No. TPM 502 2xT- LED 22W. Tube equivalent to Philips make, CAT No. MAS LED tube 1200mm 18W 865 T81-2100lm
S/f of snap-on DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as Flat angle, end caps, internal/ external angle etc. as required at site.
Detection of fault in HT/ LT underground cable of all size with FLC machine which includes pin pointing of fault, disconnection of cable from both end complete as required for First Fault
Supplying, fixing one number XLPE insulated and PVC sheathed aluminium armoured conductor power cable confirming to 1.1 KV grade of size 3.5c x 300 sq.mm
Supplying and fixing of 630 amps 4 pole Changeover switch complete with all accessories i/c making connection etc. as required.