DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF AIR CONDITIONING WORK THROUGH VRF/VRV SYSTEM FOR HUB BUILDING, IIT INDORE
2022_IITI_729347_3
IITI/IDO/M/HVAC/HUB/2022-23
Open Tender
Miscellaneous Works
Item Rate
60 days
IIT Indore Simrol Campus
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹11,277
16 Mar 2023
1 Feb 2023
9 Feb 2023
1 Feb 2023
8 Feb 2023
1 Feb 2023
Amount
Supply of inverter scroll compressor with variable refrigerant flow system with R410A connected with multi-indoor unit. Outdoor unit shall be factory assembled waterproof casing constructed from heavy gauge mild steel penal with epoxy coated painting the unit shall be complete factory wired & tested with necessary controls. The compressor fins shall be covered with anti-corrosion resin. Unit shall be equipped with oil recovery system to ensure stable operation with along refrigerant piping. VRF Outdoor Unit with the Capacity of 8.0 HP
Supply of 4 Way cassette unit with the capacity of 1.0 TR
Cordless remotes
Supply of Y-Refnet joint for refrigerant
SITC of seam less and eddy current tested hard drawn copper pipe insulated refrigerant piping. The insulation shell be closed cell elastomeric nitril rubber in sleeve using 19mm for supply and return piping. The insulation shell be class O the refrigerant piping shall be include all couplings and elbow etc. PVC sleeve to be provided wherever the copper pipe passing through walls. The refrigerant pipe shall be tested at 550 PSIG with nitrogen. Acetylene gas shall be used for brazing and low pressure nitrogen passed through pipe to removed carbon deposit .
SITC of drain pipe: Rigid UPVC drain pipe with 6mm Nitril rubber insulation complete with fitting , U trap etc & as specified to the nearest toilet with required civil work & finishing the same.
Electrical Cabling for VRF system SITC of communication between indoor and outdoor unit (3core x1.5sqmmm cu wire) laid in conduct.
Outdoor Fabricated MS stand SITC of M.S. Epoxy painted table stand for condensing unit with vibration isolator, grouting for complete platform type stand for outdoor unit.
Installation, testing commissioning with pressurized testing & vacuumizing to recommended manufacture specification, pressure testing, nitrogen flushing of air conditioning system of VRF/VRV Indoor and outdoor units with inverter compressor.
Outdoor unit Cooling capacity: 8HP
4-Way cassette units capacity: 1.0 TR
SITC Charging of refrigerant Gas 410A and Oil for Outdoor units
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .