Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹40.4 L+₹84,710 (2.14%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹40.7 L+₹1.2 L (3.03%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹41.9 L+₹2.4 L (6.05%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹41.9 L+₹2.4 L (6.11%)Rejected-Finance 40 6 UKHARA PO PRATAP PURA AGRA UP 282001 | AGRA | AGRA | UP | 282001 | L5 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | M/S OM Enterprises L3 | SahaDevSingh Constructions L8 | Attar Singh and Sons L5 | M/s S.M. Construction L1 | M/S MRITUNJAI SHARMA L2 | M/S APOORVA CONSTRUCTION L9 | M/S KAMAKHYA CONTRACTORS L6 | saroj constructions L4 | M/S RADHEY GOVIND ENTERPRISES L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Checking of LT Panel/Motor/Pump set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repairs required as per site requirement and replacing of worn out parts by expert engineer complete all as direced.
Note :- Unit rate includes detecting of any kind of fault in LT Panel/Motor/Pump set only and cost of replacement of worn out parts shall be measured and paid separately under respective items of BOQ. | 23 | Each Job | 5,000 ₹1,15,000 | 600 ₹13,800 | 633 ₹14,559 | 500 ₹11,500 | 632 ₹14,536 | 200 ₹4,600 Lowest | 630 ₹14,490 | 700 ₹16,100 | 4,000 ₹92,000 |
| 2.00 | Supply and fix in replacement starter for 1.5 to 2 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54, 230 Volt, Single Phase, with inbuilt amp & voltage meter, Rugged MU-2P contactor with wide band voltage, MU-2P Relay for reliable overload protection, heavy duty START & RUN condensers with FRLS internal wiring, and class H insulation complete all as specified and directed by engr-in-charge. | 10 | Each | 10,000 ₹1,00,000 | 3,500 ₹35,000 | 387 ₹3,870 Lowest | 3,500 ₹35,000 | 3,816 ₹38,160 | 5,000 ₹50,000 | 3,800 ₹38,000 | 4,000 ₹40,000 | 3,000 ₹30,000 |
| 3.00 | Supply and fix in replacement starter for 3HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54, 230 Volt, Single Phase, with inbuilt amp & voltage meter, Rugged MU-2P contactor with wide band voltage, MU-2P Relay for reliable overload protection, heavy duty START & RUN condensers with FRLS internal wiring, and class H insulation complete all as specified and directed by engr-in-charge. | 8 | Each | 10,000 ₹80,000 | 4,200 ₹33,600 | 4,453 ₹35,624 | 4,500 ₹36,000 | 4,452 ₹35,616 | 2,000 ₹16,000 Lowest | 4,450 ₹35,600 | 4,000 ₹32,000 | 4,000 ₹32,000 |
| 4.00 | Supply and fix in replacement Direct online starter for 5HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,415 Volt, extended wide band coil with FRLS internal wiring, star type-Air break and class H insulation complete all as specified and directed by engr-in-charge. | 2 | Each | 10,000 ₹20,000 | 7,500 ₹15,000 | 7,633 ₹15,266 | 6,000 ₹12,000 | 7,632 ₹15,264 | 2,300 ₹4,600 Lowest | 7,600 ₹15,200 | 7,000 ₹14,000 | 6,000 ₹12,000 |
| 5.00 | All as pr item No 4 above but 7.5 HP | 3 | Each | 15,000 ₹45,000 | 6,500 ₹19,500 | 6,933 ₹20,799 | 7,000 ₹21,000 | 6,932 ₹20,796 | 2,300 ₹6,900 Lowest | 7,000 ₹21,000 | 7,000 ₹21,000 | 8,000 ₹24,000 |
| 6.00 | Supply and fix in replacement fully automatic star delta starter for 10 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,3 phase, 415 Volt, 50 Hz, relay range 6-10 amps type MK1, with FRLS internal wiring and class H insulation complete all as specified and directed by engr-in-charge. | 4 | Each | 25,000 ₹1,00,000 | 7,200 ₹28,800 | 7,580 ₹30,320 | 8,000 ₹32,000 | 7,579 ₹30,316 | 5,000 ₹20,000 Lowest | 7,000 ₹28,000 | 8,000 ₹32,000 | 8,000 ₹32,000 |
| 7.00 | All as per item No 6 above but 12.5 HP | 4 | Each | 35,015 ₹1,40,060 | 6,800 ₹27,200 | 7,124 ₹28,496 | 8,500 ₹34,000 | 7,123 ₹28,492 | 2,000 ₹8,000 Lowest | 7,100 ₹28,400 | 9,000 ₹36,000 | 10,000 ₹40,000 |
| 8.00 | All as per item No 6 above but 15 HP | 3 | Each | 40,000 ₹1,20,000 | 8,000 ₹24,000 | 8,290 ₹24,870 | 10,000 ₹30,000 | 8,289 ₹24,867 | 2,000 ₹6,000 Lowest | 8,200 ₹24,600 | 12,000 ₹36,000 | 13,000 ₹39,000 |
| 9.00 | All as per item No 6 above but 20 HP | 3 | Each | 60,000 ₹1,80,000 | 15,000 ₹45,000 | 16,431 ₹49,293 | 16,000 ₹48,000 | 16,430 ₹49,290 | 2,300 ₹6,900 Lowest | 16,500 ₹49,500 | 15,000 ₹45,000 | 15,000 ₹45,000 |
| 10.00 | All as per item No 6 above but 25 HP | 4 | Each | 60,000 ₹2,40,000 | 15,500 ₹62,000 | 17,491 ₹69,964 | 18,000 ₹72,000 | 17,490 ₹69,960 | 500 ₹2,000 Lowest | 17,500 ₹70,000 | 17,000 ₹68,000 | 18,000 ₹72,000 |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
12 Aug 2025, 6:00 pmClosed
Maj Dinoop Kumar
GE (W) Agra
REPAIR/REPLACEMENT OF PUMPS, MOTORS, SUBMERSIBLE PUMP SETS ALONGWITH ALLIED WORKS TO WATER/SEWAGE SUPPLY INSTALLATION UNDER AGE E/M OF GE(WEST) AGRA
2025_MES_722258_1
8012/1123/E8
Open Tender
Civil Works
Item Rate
180 days
GE (West) Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (West) Agra
₹80,000
16 Oct 2025
24 Jul 2025
19 Aug 2025
24 Jul 2025
12 Aug 2025
6 Aug 2025
Amount
Checking of LT Panel/Motor/Pump set for detecting any kind of fault and attending the fault immediately at any time round the clock and carry out certain repairs required as per site requirement and replacing of worn out parts by expert engineer complete all as direced. Note :- Unit rate includes detecting of any kind of fault in LT Panel/Motor/Pump set only and cost of replacement of worn out parts shall be measured and paid separately under respective items of BOQ.
Supply and fix in replacement starter for 1.5 to 2 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54, 230 Volt, Single Phase, with inbuilt amp & voltage meter, Rugged MU-2P contactor with wide band voltage, MU-2P Relay for reliable overload protection, heavy duty START & RUN condensers with FRLS internal wiring, and class H insulation complete all as specified and directed by engr-in-charge.
Supply and fix in replacement starter for 3HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54, 230 Volt, Single Phase, with inbuilt amp & voltage meter, Rugged MU-2P contactor with wide band voltage, MU-2P Relay for reliable overload protection, heavy duty START & RUN condensers with FRLS internal wiring, and class H insulation complete all as specified and directed by engr-in-charge.
Supply and fix in replacement Direct online starter for 5HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,415 Volt, extended wide band coil with FRLS internal wiring, star type-Air break and class H insulation complete all as specified and directed by engr-in-charge.
All as pr item No 4 above but 7.5 HP
Supply and fix in replacement fully automatic star delta starter for 10 HP submersible pump, confirming to IS/ IEC 60947-4-1, IP-54,3 phase, 415 Volt, 50 Hz, relay range 6-10 amps type MK1, with FRLS internal wiring and class H insulation complete all as specified and directed by engr-in-charge.
All as per item No 6 above but 12.5 HP
All as per item No 6 above but 15 HP
All as per item No 6 above but 20 HP
All as per item No 6 above but 25 HP
Supply and fix in replacement 3 Pole Power contractors type MNX with AC coil, rating 18 Amps, conforming IS/ IEC 60947-4-1, IP-20,415 Volt, snap fit construction, nut retaining washer for quick termination and class H insulation complete all as specified and directed by engr-in-charge.
All as per item No 11 above but 25 Amp
All as per item No 11 above but 32 Amp
All as per item No 11 above but 150 Amp
All as per item No 11 above but 185 Amp
S&F in repair thermal over load relay type MN suitable for MNX contactors relay range 90-150 Amps including fixing arrangement complete all as specified and directed.
All as per item No 16 above but 9 to 15 Amps
All as per item No 16 above but 22 to 32 Amps
Dismantling of defective submersible pump set 20 HP with column assembly, pump bowl assembly of any size/capacity including disconnecting electrical and water line connection complete with lifting it with the help of chain pulley, clamp tripod and reassembling after repairing by lathe work and other machinery work as required and replacement of studs, nuts, bolts etc including re-fixing the same after making it serviceble in its existing position complete all as specified and directed.
All as per item No 19 above but pump set capacity 10-15 HP
All as per item No 19 above but pump set capacity 5 to 7.5 HP
All as per item No 19 above but pump set capacity 1 to 3 HP. Note (i) Defective spares for pump and column assembly shall be measured and paid separately under respective item here-in-after. (ii) After taking out submersible pump set for repair the contractor shall cover tube will with cap to avoid any accident. (ii) Defective spare parts of bowl assembly shall be measured and paid separately under items here-in-after.
Supply only the Gun Metal Impeller parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the Intermediate bowl parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the Bowl bush rubber parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the Bowl bush (Gun metal) parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the Cast iron impeller seal ring (neck ring) parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the Stainless steel running sleeve (Off sizes) parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the Pump shaft 25.4mm dia parts of submersible pump bowl assembly suitable for 10 to 20 HP complete all as directed
Supply only the CI Impeller parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the Intermediate bowl parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the Bowl bush rubber parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the Bowl bush (gun metal) parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the Cast iron impellor seal ring (neck ring) parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the Stainless steel running sleeve (off size) parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the Impellor locking keys stainless steel (off size) parts of submersible pump bowl assembly suitable for 5 to 7.5 HP complete all as directed
Supply only the PVC impellor parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Supply only the Intermediate bowl parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Supply only the Bowl bush rubber parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Supply only the Bowl bush (gun metal) parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Supply only the Cast iron impellor seal ring (neck ring) parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Supply only the Stainless steel runnig sleeve (Off size) parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Supply only the Impellor locking keys stainless steel (Off size) parts of submersible pump bowl assembly suitable for 1 to 3 HP complete all as directed
Dismantling of 01 to 03 HP Capacity defective submersible motor any make, cutting and taking out burnt out winding wire and M&L for rewinding the same with PVC insulated water proof conductor copper wire of best quality of existing gauge & turn and reassembling after replacement of bush, bearing, sleeves, grinding as required and polishing of rotor shaft etc including testing and refixing the same in existing position complete all as specified and directed. Note : Bush/bearing/sleeve/thrust plate shall be measured and paid separately under respective item here-in-after.
All as per item No 44 above but for 05 to 7.5 HP capacity
All as per item No 44 above but for 10 to 12.5 HP capacity
All as per item No 44 above but for 15 to 20 HP capacity
Supply only the Bush/bearing of suitable size (gun metal) suitable for 01-03 HP parts for the submersible motor all as directed.
All as per item No 48 above but 05/7.5 HP .
All as per item No 48 above but 10/12.5 HP .
All as per item No 48 above but 15 to 20 HP .
Supply only the Thrust Plate of suitable size (gun metal) suitable for 01-03 HP parts for the submersible motor all as directed.
All as per item No 52 above but 5/7.5 HP .
All as per item No 52 above but 10/12.5 HP.
All as per item No 52 above but 15 to 20 HP.
S&F in repairs submersible cable PVC insulated copper conductor 2.5 Sqmm 3 core 1100 volts grade complete all as specified and directed
All as per item No 56 above but 4 Sqmm.
All as per item No 56 above but 6 Sqmm.
M&L for 80mm bore, adopter nipple 50cm long GI flanged or socketed (for connecting column pipe to pump) complete all as specified and directed.
All as per item No 59 above but 100mm bore.
M&L for coupler for pump and motor of any capacity (submersible pump) complete all as specified and directed .
M&L for motor housing studs of any size complete all as specified and directed.
S&F Cast iron non return valve of size 100 mm bore, ISI marked both ends flanged including rubber gasket, MS bolts, nuts, washers and tersting complete all as specified and directed.
All as per item No 63 above but 80 mm bore.
Supply and packing pea gravel of 02 mm to to 06 mm size of the appoved quality as ordered to pack around the casing / slotted pipes in bore well complete all as specified and directed.
Developing tube wells by compressed air with minimum pressure of 10kg/Sqcm and minimum air discharge 450 CFM all as specified in IS 11189-1985 Para 4.3 complete all as specified and directed. Note : Compressor, pump, pipe and other allied items will be arranged by contractor and no extra payment will made by the department.
S&F MCCB 4 Pole, 415 V, Adjustable type, 160 Amps with breaking capacity 36 KA
S&F MCCB 4 Pole, 415 V, Adjustable type, 250 Amps with breaking capacity 36 KA
S&F MCCB 4 Pole, 415 V, Adjustable type, 400 Amps with breaking capacity 36 KA
S&F in repair single phase preventor for protection for submersible pump against over loading, reverse phase, single phasing complete all as specified and directed.
Taking up centrifugal pump set from its foundation at different location of installations by disconnecting electrically and machnically, transporting it to the workshop for dismantling the pump sets and back to installation after repairing/removing of unserviceable parts.
(a) 150 HP Capacity
(b) 100/120 HP Capacity
(c) 30 HP Capacity
(d) 15 to 20 HP
(e) 10/12.5 Capacity
(f) upto 5 Hp Capacity
M & L for re-winding of electric motor of centrifugal pump sets 3 phase 415 volts 50 Hz AC with super enamelled copper winding wire of existing weight & size incl cleaning of stator slot winding paper fixing startor incl cut x size warnshing and baking complete all as specified & directed by Engr-in-Charge for capacity :-
(a) 150 HP Capacity
(b) 100/120 HP Capacity
(c) 30 HP Capacity
(d) 15 to 20 HP
(d) 10/12.5 Capacity
(e) upto 5 Hp Capacity
Repairing of rotor assembly of centrifugal motor sets 3 phase 415 volts 50 Hz AC including dismantling and reassmbled at site complete all as specified & directed by Engr-in-Charge for capacity.
(a) 150 HP Capacity
(b) 100/120 HP Capacity
(c) 30 HP Capacity
(d) 10/12.5 Capacity
(e) upto 5 Hp Capacity
M&L painting of centrifugal pump set complete all as specified and directed by Engr - in - Charge including painting of SM No. and MES No. on the pump set for the capacity:-
(a) 150 HP Capacity
(b) 100/120 HP Capacity
(c) 30 HP Capacity
(d) 10/12.5 Capacity
(e) upto 5 Hp Capacity
Repairing/overhauling of centrifugal pump set incl cleaning of inside motor & pump set. Oiling greshing, gland packing filling and proper allignment incl repair/replacement of wear & tear are unserviceable part for
(a) 150 HP Capacity
(b) 100/120 HP Capacity
(c) 30 HP Capacity
(d) 15 to 20 HP
(d) 10/12.5 Capacity
(e) upto 5 Hp Capacity
Centrifugal pump set spare suitable for 150 HP pump set
(a) Ball bearing for motor of existing size
(b) Ball bearing pump set of existing size
(c) Roller bearing for pump set size
(d) Impeller made out of existing size
(e) Glands bush
(f) Neck Ring
(g) Cuppling complete of existing size
(h) Pump shaft incl key
(j) Rubber bush incl nut bolt and washer complete
Centrifugal pump set spare suitable for 100/120 HP pump set
(a) Ball bearing of motor of existing size
(b) Ball bearing pump set of existing size
(c) Roller bearing for pump set size
(d) Impeller made out of existing size
(e) Glands bush
(f) Neck Ring
(g) Cuppling complete of existing size
(h) Pump shaft incl key
(j) Rubber bush incl nut bolt and washer complete
S&F Centrifugal pump set spares suitable for 30 HP
(a) Ball bearing for motor of existing size
(b) Ball bearing pump set of existing size
(c) Impeller made out of brass of existing size
(d) Glands bush
(e) Neck Ring
(g) Cuppling complete of existing size
(h) Pump shaft incl key
(j) Rubber bush incl nut bolt and washer complete
S&F Centrifugal pump set spares suitable for 15-20 HP
(a) Ball bearing for motor of existing size
(b) Ball bearing pump set of existing size
(c) Impeller made out of brass of existing size
(d) Glands bush
(e) Neck Ring
(g) Cuppling complete of existing size
(h) Pump shaft incl key
(j) Rubber bush incl nut bolt and washer complete
S&F Centrifugal pump set spares suitable for 10/12.5 HP (Mono block)
(a) Ball bearing pump set of existing sizes and make.
(b) Impeller made out of CI of existing size
(c) Glands bush
(d) Neck Ring
(e) Coupling complete
(f) Pump shaft incl key
(g) Rubber bush incl nut bolt and washer complete
S&F Centrifugal pump set spares suitable for upto 5 HP (Mono block)
(a) Ball bearing of pump set of existing sizes and make.
(b) Impeller made out of CI of existing size
(c) Glands bush
(d) Neck Ring
(e) Coupling complete
(f) Pump shaft incl key
(g) Rubber bush incl nut bolt and washer complete
Material and labour for column pipe GI 'C' class for borewell 2" dia including threading and all connected works all as directed by Engr-in-Charge. Taking up of motor and lowering will be measured seperately.
Material and labour for column pipe GI 'C' class for borewell 3" dia including threading and all connected works all as directed by Engr-in-Charge. Taking up of motor and lowering will be measured seperately.
Taking out and dismantling of defective jockey pump set of 12.5 HP (Cap 10.8 cum / Hr Cap) with column assembly, pump bowl assembly, Gun metal Impeller, Intermediate Bowl, CI Impeller (Neck Ring), Bowl Bush Rubber/Gun Metal, etc Parts, including disconnecting electrical and water line connection complete with lifting it with the help of chain pulley, clamp tripod and reassembling after repairing by lathe work and other machinery work as required and replacement of studs, nuts, bolts and other defected parts etc including re-fixing the same after making it serviceble in its existing position complete all as specified and directed.
M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm size, buried directly in ground (earth pit not less than 3.25M deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to and including galvanized steel earth strip 32 x 6mm, including 40mm bore GI light grade protection pipe as earth lead strip connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150mm thick alternate layers of charcoal or cock dust & common salt 20mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) cover 50mm thick of precast RCC 1:2:4 type B-1 (using 20mm graded stone aggregate) duly reinforced with 8mm deformed or twisted bars @ 100mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/loose soil and deposited the surplus soil to a distance n.exc 50mtr away from starting point complete all as specified and shown in electrical plate No 3 of MES standard schedule of rates 2009 Part-I all as specified and directed.
Supply and fixing UPVC column pipe 80 mm bore 12 Kg working pressure standard grade for pump set including plastic rope for supporting of submersible motor necessary fitting and connection to submersible pump complete all as specified and directed.
All as per item No. 86 above but 100 mm bore
All as per item No. 86 above but 50 mm bore
Supply and fixing plastic rope 25 mm for supporting of submersible motor with necessary fitting and connection to submersible pump complete all as specified and directed.
Supply and fixing plastic rope10 mm for supporting of submersible motor with necessary fitting and connection to submersible pump complete all as specified and directed.
M & L in repairs 80mm bore Cast Iron sluice valve both ends flanged PN-1.6 with iron wheel (ISI Marked including nuts, bolts, washer and 3 mm thick rubber insertion sheet complete all as specified and directed.
All as per item No- 91 above but of size 100mm bore
All as per item No- 91 above but of size 150mm bore
All as per item No- 91 above but of size 200mm bore
M & L for CI Butterfly Valve 150 mm PN1.6 as PER BS EN 593 (BS 5155) IS 13095, Body Cast Iron IS:210 FG 260, Disc Ductile Iron IS 1865 Gr 400/15( Epoxy Coated) Stem SS ASTM A 276 Type 410 Seat-Nitrile/ EPDM Rubber Ends, Wafer Type to Suit Mounting between Flanges drilled to IS 1538 with Hand lever Operated.
Supply, laying testing, connecting XLPE armoured, LT 1100V grade (heavy duty) copper conductor cable,of following sizes confirming to IS7098(Part-I) 1988, laid in existing RCC covered duct/Sub way/along wall/MS bracket. Note : The Cables shall be fixed to LT panel with suitable size brass/stain less steel cable glants, copper lugs and rate deemed to be included in rate quoted for respective cable
a) 3 Core 95 Sqmm
b) 1 Core 70 Sqmm
M/S MRITUNJAI SHARMA (BID ID -3390548)
M/S OM Enterprises (BID ID -3391202)
saroj constructions (BID ID -3390065)
Attar Singh and Sons (BID ID -3391430)
M/S KAMAKHYA CONTRACTORS (BID ID -3389889)
M/S RADHEY GOVIND ENTERPRISES (BID ID -3390681)
SahaDevSingh Constructions (BID ID -3389243)
M/S APOORVA CONSTRUCTION (BID ID -3390534)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .