Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.0 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹26.5 L+₹89,252 (3.48%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹26.6 L+₹92,895 (3.62%)Rejected-Finance LIG 10 VIVEK NAGAR NAVIBAGH BHOPAL MADHYA PRADESH 462038 | BHOPAL | MADHYA PRADESH | 462038 | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹26.9 L+₹1.3 L (5.05%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
5 Nov 2022, 6:00 pmClosed
GE BHOPAL
GE BHOPAL BAIRAGARH BHOPAL
REPAIRS TO SEWAGE LINE SEPTIC TANKS SOAKAGE PITS AT SI LINES REPAIR MAINT OF SEWAGE PUMP HOUSES AND FIRE PUMP HOUSE AT BAIRAGARH AND REPAIR MAINT OF DG SET 750 kVA 03 Nos IN MH BHOPAL AND REPAIR MAINT OF DG SET AT VARIOUS LOCATIONS AT BAIRAGARH
2022_MES_556598_1
8940/E8
Open Tender
Civil Works
Item Rate
335 days
BHOPAL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE BHOPAL
₹70,000
Yes
13 Feb 2023
10 Oct 2022
7 Nov 2022
10 Oct 2022
5 Nov 2022
24 Oct 2022
Amount
Note :(i) Please refer Sch A/ BOQ Notes before quoting the tender for all phases/ items mentioned below. (ii) Amount of Schedule of credit shall be deducted offline Note: This work comprises of (i) REPAIRS TO SEWAGE LINE, SEPTIC TANKS, SOAKAGE PITS AT SI LINES UNDER GE BHOPAL (ii) REPAIR/ MAINT OF SEWAGE PUMP HOUSES AND FIRE PUMP HOUSE AT BAIRAGARH (iii) REPAIR/ MAINT OF DG SET (750 kVA) (03 Nos) IN MH BHOPAL AND REPAIR/ MAINT OF DG SET AT VARIOUS LOCATIONS AT BAIRAGARH The qty of individual part shall not vary beyond deviation limit specified in tender.
REPAIRS TO SEWAGE LINE, SEPTIC TANKS, SOAKAGE PITS AT SI LINES UNDER GE BHOPAL
Demolition of reinforced cement concrete in ground floors and paving n exc 15cm thickness (below and above ground level) complete all as specified and directed.
Demolition of brickwork built in cement or cement lime mortar complete all as specified and directed.
Demolition and breaking up drain pipe of 100/150mm internal (SGSW) pipe/PVC/RCC set in cement mortar and disposel of unservicable material and rubbish to a distance not exc 100m complete all as specified and directed.
Demolition and breaking up drain pipe of 200mm internal (SGSW) pipe/PVC/RCC set in cement mortar and disposel of unservicable material and rubbish to a distance not exc 100m complete all as specified and directed.
Demolition and breaking up drain pipe of 300mm internal (SGSW) pipe/PVC/RCC set in cement mortar and disposel of unservicable material and rubbish to a distance not exc 100m complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in hard/dense soil complete all as specified and directed.
M&L for Cement concrete 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
M&L for Brick work with fly ash bricks (Modular), straight or curved on plan exceeding 6m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls, ceilings, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L rendering 15mm thick on fair faces of brick or concrete surface in CM 1:4 finished even and smooth without using extra cement complete all as specified and directed
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in surface channels and drains, complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed
Extra for forming fair finished drain or channel 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc, complete all as specified and directed
Use and waste of form work to soffits of suspended slabs as in roof slabs,floor slabs,landings and similar work not exceeding 200mm thick for rough finished flat surfaces, complete all as specified and directed
S&F Mild steel TMT bars 6 to 8mm dia as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Providing precast reinforced cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate in cover slabs (for manholes etc), shelves and similar articles with plain faces including necessary moulds and setting in cement mortar 1:4 complete all as specified and directed. (Note:- Reinforcement shall be measured and paid separately.)
S&F PVC (SWR) pipes 160 mm IS-15328 (nominal diameter & Class 1) single or double socketed in any length with elastomeric sealing ring type or solvent cement joints laid in trenches as specified and directed.
S&F reinforced concrete pipes, class NP3, 150 mm bore, laid and jointed with collars complete all as specified and directed.
S&F reinforced concrete pipes, class NP3, 300 mm bore, laid and jointed with collars complete all as specified and directed.
S&F reinforced concrete pipes, class NP3, 150 mm bore, laid and jointed with collars complete all as specified and directed.
S&F Salt glazed stoneware drain pipes 150 mm bore, grade ‘A’, laid in trenches, including testing and jointed complete all as specified and directed.
S&F Salt glazed stoneware drain pipes 200 mm bore, grade ‘A’, laid in trenches, including testing and jointed complete all as specified and directed.
S&F Salt glazed stoneware drain pipes 300 mm bore, grade ‘A’, laid in trenches, including testing and jointed complete all as specified and directed.
M&L for laying DWCP 150mm dia pipes in trenches class SN-8 conforming to IS 16098 (Part-2) in 6 mtr length with coupler, complete all as specified and directed
M&L for laying DWCP 200mm dia pipes in trenches class SN-8 conforming to IS 16098 (Part-2) in 6 mtr length with coupler, complete all as specified and directed
M&L for laying DWCP 300mm dia pipes in trenches class SN-8 conforming to IS 16098 (Part-2) in 6 mtr length with coupler, complete all as specified and directed
Cutting into existing manhole for connecting new sewage line 150/200mm bore including making good to disturbed portion with benching and haunching, plaster etc and forming new bracnch channel (1/2 round of 3/4 section) if required in cement concrete 1:2:4 type B-1 and smooth finished, reforming benching as required, complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick each layer as in soil complete all as specified and as directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Cleaning of existing sewage line of any dia by rodding, flushing etc and taking out blocked sludge through existing manhole or sewage pit and burried in suitable pit dug out for the purpose covered with excavated soil including new pit, complete all as specified and directed
Cleaning of manhole with full of sludge any depth by manually or any other method and taking out sludge / grit and deposited in new pit dug out for the purpose covered with excaveted soil including digging out pit, complete all as specified and directed
Cleaning of septic tank / soakage well sludge chamber (inlet & outlet) etc of any depth including cleaning of sludge/grit from last manhole to septic tank by manually or any other method. Taking out sludge / grit complete including removing /depositing all spoils/sludge in new pit dug out for the purpose covered with excavated soil including digging out pit, complete all as specified and directed
Cleaning of sewage line from WC/Gully trap to first manhole / cleaning of WC in first floor to first manhole including removal of sludge by rodding or by another method, complete all as specified and directed.
Cleaning of bathroom floor trap to first manhole / cleaning of bathroom floor trap in first floor to first manhole including removal of sludge by rodding or by another method, complete all as specified and directed.
Taking out water/Sludge/Waste from septic tank, soak well sludge chamber manually or by pumping taking out sludge / grit complete including removing / depositing all spoils/sludge in new pit dug out for the purpose covered with excavated soil, complete all as specified and directed
Demolition of stone slabs and tiles of any description or thickness in floors, aprons, walls, etc, laid bedded and pointed in any mortar complete all as specified and directed.
M&L for Non skid ceramic coloured joint free tiles 7mm to 8mm thick (square/rectangular), area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 15mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Machine cut Kota stone slab flooring 20-25mm thick with and including 20mm thick cement screed base in CM 1:3, laid and jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and mirror polishing complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing tiles/ rubbish off the permises to a distance not exceeding 250m complete all as specified and directed.
M&L for Glazed ceramic coloured tiles 350mm x 250mm x 7mm thick or 450mm x 350mm x 7mm thick, in vertical surfaces such as skirting, dados and risers to steps, etc set and jointed in neat cement slurry and pointed in white or coloured cement to match tiles with & including 10mm thick rendering in CM 1:3 complete all as specified and directed.
S&F in repairs Vitreous china squatting pan ‘Orissa’ pattern, ISI marked, size 580 x 440 mm, white with integral foot rests including provision of cement concrete bedding & ‘P’ or ‘S’ trap complete all as specified and directed.
S&F in repairs vitreous china wash down water closet pan, pedestal pattern, ISI marked, white, including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminium hinging device complete all as specified and directed.
S&F 15 mm bore, bib cock two way with flange, cast copper alloy, fancy type, chromium plated screwed down for iron pipe and fixed in repairs, complete all as specified and directed .
S&F hand shower (health faucet) brass with 1.0 mter long flexible tube and wall hook complete all as specified and directed. [MAKE:- Prayag (Cat No.BEA-81) or equivalent in MARC/ JAQUAR/ make as per Appx 'C' (list of make) as approved by GE]
S&F in repairs Plastic water closet seat cover, any colour, closed pattern with flat bottom, and mild steel chromium plated for aluminised hinging device, complete all as specified and directed.
S&F in repairs Vitreous china wash basin, ISI marked, white, flat back, size 550 x 400mm, including CP waste coupling, 32mm dia PVC waste pipe of suitable length, brackets and cutting for and pinning in ends of brackets, complete all as specified and directed.
S&F Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot’ or ‘Cold’ with long screwed shanks and fly nuts, screwed for iron pipe 15mm bore complete all as specified and directed
S&F in repairs PVC low level flushing cistern 10 litres capacity, ISI marked, white, with all fitting and fixtures including brackets, PVC connection of 450mm long and 32 mm bore PVC flush pipe, complete all as specified and directed.
&F in repairs Vitreous china bowl urinal flat back, white, with grating and union for discharge pipe including connections to flush pipe and outgoing pipes, complete all as specified and directed.
M&L in repair 75mm dia PVC (SWR) floor trap plain with CP grating including jointing with solvent cement, complete all as specified and directed.
S&F PVC (SWR) pipes, double socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, double socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) pipes, single socketed, in any length with rubber ring joints, laid in trenches, floors or fixed to walls, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 75 mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius, 110 mm bore complete all as specified and directed.
S&F PVC (SWR) branch piece single (Y) equal or unequal bend, 75 mm bore, complete all as specified and directed.
S&F PVC (SWR) branch piece single (Y) equal or unequal bend, 110 mm bore, complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 75mm bore complete all as specified and directed.
S&F PVC (SWR) junction single (single T), equal or unequal, 110mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl, 75mm bore complete all as specified and directed.
S&F PVC (SWR) vent cowl, 110mm bore complete all as specified and directed.
M&L for mild steel Rolled/tubular sections as in manhole cover and frame as per specified jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410-W (Gde E-250) quality B, complete all as specified and directed
S&F of 1.6 mm thick Mild steel, plain black sheet in hearths; covering to man holes, water tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc, complete all as specified and directed
M&L for Preparation of old surfaces of wall including brooming , scraping down and applying two coat of white wash on walls complete as specified and directed.
M&L for Preparing new or previously untreated steel & iron surfaces of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over & including a coat of red oxide zinc chrome primer complete all as specified and directed.
M&L for Factory made, machine pressed, M-40 grade concrete interlocking paver blocks (glossy/reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 80 mm thickness with & including 50 mm thick sand cushion and joints filled with sand complete all as specified and directed.
M&L for taking out old existing interlocking paver blocks any thickness, size & type from the existing location including sand dust, stacking properly the serviceable tiles for reuse; removal of the unserviceable materials & disposal to low lying areas at a distance not exceeding 250m and relaying the paver blocks by providing 50 mm thick stone dust cushion and joints filled with sand complete all as specified and directed. [NOTE: The quoted rate is deemed to include for coarse sand & dust as required at site.]
M&L for Factory made, machine pressed, M-35 grade concrete interlocking paver blocks (glossy /reflective type), with grey cement and pigment, any shape and size conforming to IS:15658-2006 (ISI Marked) of 60 mm thickness with & including 50 mm thick sand cushion and joints filled with sand complete all as specified and directed
M&L for rendering 15mm thick in cement mortar 1: 6 on faces of brick work or concrete surfaces, finished even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces of wall and applying two coat of white wash on walls complete all as specified and directed.
M&L for grouting with cement mortar with mechanical pressure through nozzles HD PVC 10 CM long 25mm dia to stop cracks /leakagesand seepage from wall floor nozzles shall be fixed at 1 mt c/c in stagered manner and mortor (CM 1:1) mixed with WPC shall be filled with pressure to stop leakage (seepage in cracks, concrete, walls or floor) till rejection finishing the nozzles by concrete mix with appoxy after treatment including taking down plaster, complete all as specified and directed.
Providing & Laying in surrounding of Joints of Pipe of any dia etc of first coat of ShaliUrethane/liquiurethane BTD, water based single component white coloured polyurethane liquid membrane having solid content over 80%, service temperature from Minus 20 deg C to +100 dg C, Zero VOC content and with excellent UV stability; conforming to ASTM C 836 and 6083 of STP Make/ IWL/Pedilite/TEXPUR of Texsa/ Hyperdesno of Alchimica/ New Flex of W R Grace using @ 0.5Kg/Joint and laying, ShaliGeo Text 50 or ShaliGeo Text nylon/ glass fibre net with an overlap of 50mm while the surface is tacky and allow to dry for 10 to 12 hrs, thereafter applying second coat of ShaliUrethane/liquiurethane BTD @ 0.5Kg/Joint saturating the reinforcement core and allow it to cure for overnight all deck pipe, are to be coated and terminated at the outer surface of the Pipe surrounding, complete all as specified and directed.
M&L 50 mm Sand stone slabs in foothpath, sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan and not exceeding 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in HARD ROCK complete all as specified and directed.
S&F in repairs Vitreous china urinal sensor operated starwhite including fixing to walls and complete installation and union for discharge pipe including connections to flush pipe and outgoing pipes, complete all as specified and directed. [MAKE:-JAQUAR (Cat No.60021) or equivalent make as per Appx 'C' (list of make) as approved by GE]
S&F in repair of vitreous China wash down water closet pan, casket type (pedestal pattern), with integral seat cover and flush tank, coloured, complete all as specified and directed. [MAKE:-HINDWARE (Cat No.92045) or equivalent make as per Appx 'C' (list of make) as approved by GE]
S&F in repairs Vitreous China Urinal Half Stall type, white with union for discharge pipe including waste pipe and urinal spreader fixing with 15mm dia pipe complete all as specified and directed
Attending day to day complaint of different type of sewage work such blockage of WHB, WC, urinals, sink, bottle trap, floor trap, nahani trap, 'P' or 'S' traps of WCs, gully trap, vertical CI/SWR pipes of any dia including junction holes of any description of various units area, single living accn, JCOs/OR/Offrs Md accn and any other accn in SI Lines area, repairing of CI/SWR pipes joints (lead/cement/adhesive joints), cleaning of sewage lines, manholes of any size and depth and making it fully functional and removal of sludge/mud out side of defence land on all days excluding sundays and holidays by employing 02 x safaiwala (mazdoor) with proper dress and tools to entire satisfaction of Engr-in-charge complete all as specified and directed
REPAIR/ MAINT OF SEWAGE PUMP HOUSES AND FIRE PUMP HOUSE AT BAIRAGARH
S&F Copper cable of size 25 sqmm single core, 440 Volt 50 Hz, draw in PVC conduit not less than 25 mm including taking out old cable, complete all as specified and directed.
S&F foot valve 80mm size Cast iron body flange type ISI marked including nut, bolt all connected fitting including taking down old foot valves complete all as specified and directed.
S&F foot valve 100mm size Cast iron body flange type ISI marked including nut, bolt all connected fitting including taking down old foot valves complete all as specified and directed.
S&F in replacement automatic starter of star delta in sheet metal enclosure type, wall mounting suitable for centrifugal pump /submercible pump/monoblock pump pump of 3 phase, 415 volt, 50 hz, suitable relay range in 5 to 30 Amp, ML contactor, ML over load relay all including taking out old starter single phase preventer fittngs complete all as specified and directed.
S&F in replacement of MCCB 4 pole, 63 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
S&F 80mm bore CI pipe flange ends centrifugally cast, class A , in any length, laid in trenches complete all as specified and directed.
S&F 100mm bore CI pipe flange ends centrifugally cast, class A, in any length, laid in trenches complete all as specified and directed.
S&F in replacement of MCCB 4 pole, 100 Amp 36 kA breaking capacity, including suitable size copper lugs and connected fittings, complete all as specified and directed.
S&F in replacement power contactor, type ML-4, 3 pole, 415V, 50Hz, 3 Phase, with auxilary contacts 2 N L&T (Cat No -SS90910) L&T /Legrand/ Seimens/ Schinider as approved by GE]
S&F in replacement power contactor, type ML-6, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schenider as approved by GE]
S&F in replacement power contactor, type ML-2, 3 pole, 415 V, 50Hz, 3 Phase with auxilary contacts 2 NO + 2 NC complete all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schenider as approved by GE]
S&F in replacement electronic timer for Star Delta Starter type, timing range 3-30 sec, 415 V, 50 Hz complete all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schenider as approved by GE] ]
S&F in replacement thermal over load relay for Star Delta Starter type, timing range 5-30 amp, 415 V, 50 Hz complete all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schinider as approved by GE]
S&F in replacement thermal over load relay for Star Delta Starter type, timing range 66-120 amp, 415 V, 50 Hz complete all as specified and directed. [Make :- L&T / Legrand/ Seimens/ Schenider as approved by GE]
S&F in replacement automatic starter of 60 hp star delta in sheet metal enclosure type, wall mounting suitable for centrifugal pump of 60 HP, 3 phase, 415 volt, 50 hz, relay range 60 -110 Amp, ML6 contactor, ML over load relay all including single phase preventer fittings complete all as specified and directed. Make: Havells/L&T/ Crompton greaves as approved by GE]
Disconnecting / Dismantling of 5/15/20 HP Non Clog motor Pump /VTP /submersible pump / centrifugal pump Set assy from its foundation at Sewage Pump House / pump house Bairagarh and transporting to civil workshop for repair complete and taking back after repairing, fixing to its existing position and making all connections.Dismentling and opening of pump assy for checking out defects. Taking out shaft from pump and carrying out lathe work on shaft for checking and making straightness. Taking out of old worn out brass impeller and M&L for filling material on worn out part , grinding, poilshing and carrying out complete lathe work, refixing on shaft and check for its smooth functioning and balancing complete all as specified and directed. NOTE:- (i) Spares/parts shall be paid under relevent item here-in-after under as supply only. (ii) Cost of Minor spare parts; which are not included in subsequent items given herein-after but are required for making the motor functional is deemed to be included in the quoted rate.
Removing of burnt winding, cleaning of slots and Rewinding of 5/15/20 HP motor with new high class insulated copper wire of existing gauge, insulation paper, varnishing, heating etc. complete all as specified and directed.
Supply only the following parts suitable for 5/15/20 HP Non Clog motor Pump/VTP/submersile pump as per original manufacturers specification complete all as specified & directed.
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor shaft
Bearing suitable for pump set
Supply & fixing the following parts suitable for 60 HP centrifugal pump as per original manufacturers specification complete all as specified & directed.
Bowl bush
Impeller
Neck ring
Shaft sleeve
Pump shaft
Coupling
Coupling key
Impeller key
Stud with nuts
Thrust bearing
Lower housing bush
Upper housing bush
Rotor shaft sleave
Drain plug
Water seal
CI Bowl
Rotor shaft
Bearing suitable for pump set
S&F in repair Round copper lugs, 25mm dia, complete all as specified and directed.
S&F in repair Round copper lugs, 35mm dia, complete all as specified and directed.
S&F in repair Round copper lugs, 50mm dia, complete all as specified and directed.
S&F in repair Round copper lugs, 16mm dia, complete all as specified and directed.
M&L for cleaning of existing drainage system (Approx 100 m length) of Filter Pump House and cutting grass around 3 metre both sides, complete all as specified and directed.
Supply, fabrication and fixing MS channel/ pipe fitting/barrel piece /lateral pipe as per site requirement including nut, bolt, washer, welding etc and fibre board gasket complete and making joint leak proof including dismantling old structure complete all as specified and directed.
REPAIR/ MAINT OF DG SET (750 kVA) (03 Nos) IN MH BHOPAL AND REPAIR/ MAINT OF DG SET AT VARIOUS LOCATIONS AT BAIRAGARH
Servicing of DG sets of capacity from 110 KVA to 200 KVA Make- Ashoka wand, Ruston & cummins at 250 running hours or 6 months whichever is earlier including replacement of defective / warnout parts by new spares such as filters, gaskets, V belts Engine oil, rubber hoses, worm drive clamps, nuts & bolts and B check kit complete all as specified and directed. (Note- Supply only Spare parts will be measured and paid saperately under relavent item )
Supply only the following for repair of 110 KVA to 200 KVA DG set :-
(a) Element fuel filter Cat No-3238203
(b) Element fuel filter Cat No-3238493
(c) Kit supper by pass filter Element Cat No-3879488
(d) Plug pipe Cat No- S-995
(e) Plug pipe Cat No- S-915 A
(f) Plug pipe Cat No- 67622
(g).Hose flexible Cat No- AK-5033 SS
(h) Cotrol Safety(Water), Part No-194505
(j) Control Safety (Lub Oil) , Part No-194504
Servicing of DG sets of any capacity from upto 50 KVA Make- Kirlosker, Ruston & cummins at 250 running hours or 6 months whichever is earlier including replacement of defective / warnout parts by new spares such as filters ,gaskets , V belts Engine oil, rubber hoses , worm drive clamps ,nuts & bolts and Bchack. KIT complete all as specified and directed. (Note- Supply only Spare parts will be measured and paid saperately under relavent item )
Supply only the following for the repair of 50 KVA DG set :-
(a) Element fuel filter
(b) Element oil filter
(c) Kit supper by pass filter Element
(d) Plug pipe Cat No- S-995
(e) Plug pipe Cat No- S-915 A
(f) Plug pipe Cat No- 67622
(g).Hose flexible
(h) Cotrol Safety(Water),
(J) Coppling Suitable for exising DG Set with Lubjoy rubber coppling
Servicing of DG sets of any capacity from 320 KVA Make- Cummins at 250 running hours or 6 months whichever is earlier including replacement of defective / warnout parts by new spares such as filters ,gaskets , V belts Engine oil, rubber hoses , worm drive clamps ,nuts & boltsand Bchack. KIT complete all as specified and directed. (Note- Supply only Spare parts will be measured and paid saperately under relavent item )
Supply only following for repair of 320 KVA DG set :-
(a) Element Lub oil Cat No-3238204
(b) Element Fuel filter Cat No-3238493
(c) Kit supper by pass filter Element Cat No-3879488
(d) Belt V Cat No- 3001600
(e) Belt V Cat No- 178567
(f) Hose flexible Cat No- AK-5041 SS
(g) Hose flexible Cat No- AK-6045 SS
(h) Hose flexible Cat No- AK-6065 SS
(j) Hose flexible Cat No- AK-10075 MS
(k) Hose flexible Cat No- AK-10024 SS
(l) Hose flexible Cat No- AK-10030 SS
(m) Hose flexible Cat No- AK-6054 ST
Supply only, diesel filter suitable for followling capacities of DG sets:- (a) 50 KVA and upto 110 KVA Primery & secondary set Make-Ruston
Supply only Air cleaner elements inner and outer for 50 KVA. to 200 KVA DG sets of cummins make .(Inner & outer)
Supply only Air cleaner elements inner and outer for 320 KVA. DG sets of cummins make .Cat No-3226018, 3226019 (Inner & Outer )
Supply only Battery turminal heavy duty brass with nut & bolts complete.
Supply only Petrolium jelly in 1 kg plastic sealed container.
Supply only Battery lead for 180 AH 12 volts battary copper conductor PVC insulated multisranded 1.5 mtr longe duly fixed with turminals & lugs .
Supply only Bty link lead with Bty terminal of +/- terminal 0.3 mtr long
Supply only Oil pressure gauge suitable for YDA series DG set
Supply and filling in sump / topping up engine oil, multi grade 20w / 40 in engine or replacement of engine oil Make :- Indian oil / Hindusthan petrolium / Castrol / Pried /Servo
Repair overhauling & removal of leakage from radiator & refixing it duly repaired, cleaning descaling, welding brazing etc. incl. Replacement of rubber hoses & clips etc. complete in all respect of the followling capacities of DG sets :-
(a) 100 KVA to 320 KVA
(b) 10 KVA to 100KVA
Repair / overhauling of self starter 10KVA - 320 KVA incl. Replacement of carbon brusses, bearing, bushes, rewinding of armature and fild etc. and varnishing complete all as directed (for the 12 volt make lucas).
Spray painting of DG sets, Alternator, Panel, diesel tank and base frame etc. with one coat of synthetic enamel paint as per MES colour code after cleaning of old painted surface rubbing of old paint and preperation of surface for paint etc complete all as directed by EIC for the following capacity DG set:-
(a) 110 KVA to 200 KVA
(c) 10 KVA to 100 KVA
S&F heat proof Asbestos rope 12 mm dia in engine exhaust pipe including dismantling of worn out Asbestos rope and minor welding / tightening in leakage exhaust complete all as directed conforming to IS specification fire proof /flame proof.
Calibration and over hauling FTP or PT Pump of 10 KVA t0 50 KVA DG Set with replacement of the following parts :- (a) Delivery valve - 06 Nos. (b) Bearing - 02 Nos. (c) Elements - 06 Nos. (d) Main spring - 06 Nos. (e) Gasket sets. (f) Seal. (g) Cap screw. (h) 'O' ring - 01 Set. (j) Governer assembly - 01 Set. (k) Screen filter.
Dismantling of old self starter of capacity 24 volts from engine and shifting to civil workshop for repair/overhauling of the self starter by rewinding of one field coil, repair and rewinding of armature and return to the existing place after repairing.
Earthing complete with GI steel earth plate electrode 60cm x 60cmx6.3mm thick barried directly in ground vertically to a depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 mtrs below level ground, connected to GI iron or steel earth wire 4mm dia (8 SWG) by means of nuts, volts checks nuts and washers made of GI iron or steel earth wire protected by GI iron pipe 15mm bore, medium grade and connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, pre-cast RCC over slab 30cmx30cmx10cm with one lifting handle made of 8mm dia MS bar funnel wire mesh, 20mm bore GI or steel pipe medium grade for watering, charcoal or coke and salt in alternate larges, necessary excavation and earth work in any type of soil complete all as shown in electrical plate No 5 of MES schedule Part-I and testing after completion.
Supply only the following items for various DG Sets :-
(a) Battery 12 volts 92 AH Make Exide.
(b) Battery 12 volts 180 AH Make Exide.
(f) Rubber coupling.
Repairing of diesel engine generating set, capacity from10 KVA to 110 KVA and dismantling of the engine strip opening etc. (a) Valve seat cutting and fixing of the valve guide. (b) Griding and polishing of crank shaft complete. (c) Fixing of the cylinder liner. (d) Cylinder block line bearing and threading of existing holes. (e) Fixing of the piston ring complete. (f) Repair to cylinder head, injector sleeves including fixing and testing complete. (Note : All spare parts for replacement/fixing shall be supplied under relevant items).
Testing of collected water sample from NABL /aprroved GOI lab from Bairagarh complete all as specified and directed.
(a) Main filter pump house, Bairagarh
(b) TRS Pump House, Bairagarh (at 115 ER Unit Area)
(c) Key personnel Pump House< MES Colony Area
(d) 21 CGSR Pump House
(e) Swimming Pool Bairagarh
S&F Change Over switch 4 pole 250 Amps, 50 KA complete all as specified and directed. Make L&T/siemens/Schneider
S&F Change Over switch 4 pole 450 Amps, 50 KA complete all as specified and directed Make L&T/siemens/Schneider
Repair & comprehensive maintenance of DG sets of any make of the following capacities which include replacement of worn out spares such as fuel filter, oil filter, lubricating oil hoses, V- belt, Oil pipes, fuel pipe, water pump, cut out and tightening of nut bolts, washers etc of DG sets complete all as specified and directed.
750 KVA capacity
10 KVA capacity
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 750 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 10 KVA by authorised representative of manufacturer (OEM) by "B" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 10 KVA by authorised representative of manufacturer (OEM) by "C" check of Engines complete all as specified and directed.
Periodical maintenance of DG set 10 KVA by authorised representative of manufacturer (OEM) by "D" check of Engines complete all as specified and directed.
M&L for Replacement of the following spare parts for 10 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahendra complete all as specified and directed:-
Head Gasket Kit complete
Fuel Filter
Lubricating Oil Filter
Hose Pipe Set
M&L for Replacement of the following spare parts for 750 KVA of Make:- Kirloskar / Greaves Crompton / Cummins / Mahendra complete all as specified and directed:-
Head Gasket Kit complete
Fuel Filter
Lubricating Oil Filter
Hose Pipe Set
Dismantling and taking down radiator assy from engine of any capacity for repairs including descaling, bracing as necessiated to plug leakages, M&L for transporting of the radiator of capacity 750 KVA and repair/maintenance to the radiator fins with the help of cleaning coil solution and cleaning the radiator complete and repair to the leakage places by means of gas welding and including initial filling up coolant and re-fixing after repairs including replacement of worn out nut bolts, washers, etc; and testing complete all as specified and directed.
Dismantling and removing fuel injection pump from DG set for repairs including re-calibration at authorised service centres, replacement of necessary spare parts such as delivery valves, plunger, 'O' ring, springs etc and refixing, testing complete all as specified and directed of the following capacity:-
750 KVA capacity
10 KVA capacity
Repair / Overhauling of self starter 12 / 24 Volt of any make / capacity including replacement of minor items such as carbon brushes, nuts, bolts etc; all as necessitated complete all as specified and directed. Note:- All additional spares as required will be measured and paid seperately under relevant items.
M&L for Replacement of following spares for self starter 12 / 24 V complete all as specified and directed :-
Field coil
Armature
Clutch assembly
M&L for Replacement of battery lead, copper conductor 25 Sq mm, multi stranded, PVC insulated with suitable terminals at both ends complete all as specified and directed.
M&L for Replacement of Fan belts as per sample for DG sets of capacity:-
750 KVA capacity
10 KVA capacity
M&L for Replacement of fuel flexible pipe, heavy duty with check nuts for DG sets of any make/capacity complete all as specified and directed.
Dismantling of alternator assy 750 KVA DG Set and taking out regulating transformer carefully and rewinding of regulating transformer including refitting and testing complete all as specified and directed.
Dismantling of alternator assy 10 KVA DG Set and taking out regulating transformer carefully and rewinding of regulating transformer including refitting and testing complete all as specified and directed.
M&L for Replacement of only water pump suitable for DG sets of following capacity:-
750KVA capacity
10 KVA capacity
M&L for Replacement of Control Safety (Lub oil) for 750 KVA DG Set complete all as specified and directed.
M&L for Replacement of Control Safety (Water) Part No. for 750 KVA DG set complete all as specified and directed.
M&L for Replacement of S.D. Valve for 750 KVA DG set complete all as specified and directed.
M&L for Replacement of Oil Coolent additive concentrate pack of 10 Ltr suitable for DG Set complete all as specified and directed.
Supply only Distilled water in 5 ltr PVC Container complete all as specified and directed.
M&L for Replacement of air filter outer & inner element for 750 KVA D G set as per sample complete all as specified and directed.
M&L for Replacement of air filter outer & inner element for 10 KVA D G set as per sample complete all as specified and directed.
Taking out unserviceable alternator from 750 KVA DG set and removing starter and rotor, removing old burnt out winding wire and rewinding the stator of suitable size with super enameled copper wire and insulating materials complete including re-assembling the complete alternator, fixing in position and testing on load complete including replacement of bearing of suitable size – 01 Set complete all as specified and directed.
S&F in replacement On load changeover switches, 4 pole, 200 Amp manual changeover in open execution complete all as specified and directed. Make - L&T (Cat No.CO22000OOOA) or equivalent in Havells/C&S as approved by GE.
S&F in replacement On load changeover switches, 4 pole, 100 Amp manual changeover in open execution complete all as specified and directed. Make - L&T (Cat No.CO11000OOOO) or equivalent in Havells/C&S as approved by GE.
S&F in replacement maintenance free lead acid battery 12 volt, 180 Ah with minium 24 months warranty) of complete all as specified and directed. [MAKE:- EXIDE / TATA / AMARON]
S&F in replacement of complete Engine controller HMI remote unit display power command with mother board for 750 KVA DG Set complete all as speified and directed. Make of DG Set : Cummins Cat Part No -300-6315-02 PCC 3300
Schedule of credit (calculation will be done off line) Rs. 67116.65
Adamya Group Of Company
PRAGATI ELECTRICALS AND ELECTRONICS
RAJPATI CONSTRUCTION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .