Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAccepted-AOC OPP RAM MANDIR NALIYA KUTCH 370655 | KACHCHH | GUJARAT | 370655 | ₹1.7 Cr | L1 | Accepted-AOC Being L1 |
| 2 | L2₹1.8 Cr+₹2.2 L (1.23%)Rejected-Finance 0 TANDA VILLAGE KHAIRPUR TANDA AYODHYA VILLAGE TOWN POST MAKHDOOM NAGAR CITY AMBEDKAR NAGAR AMBEDAKAR NAGAR UTTAR PRADESH 224190 INDIA | AMBEDKAR NAGAR | UTTAR PRADESH | 224190 | ₹1.8 Cr+₹2.2 L (1.23%) | L2 | Rejected-Finance NOT Being L1 |
| 3 | L3₹2.0 Cr+₹23.1 L (13.2%)Rejected-Finance | ₹2.0 Cr+₹23.1 L (13.2%) | L3 | Rejected-Finance NOT Being L1 |
Tender Value
Refer Docs
EMD Value
₹2.4 L
Closing Date
15 Jul 2021, 6:00 pmClosed
CE CG GOA
HQ CE CG GOA 403806
PROVISION OF STRESS MANAGEMENT CENTRE CUM GYMNASIUM AT ICGS MUNDRA UNDER AGEICG JAKHAU
2021_MES_426072_3
82020/E8
Open Tender
Civil Works
Lump-sum
365 days
MUNDRA UNDER AGEICG JAKHAU
As per tender document
7 documents required · 7 mandatory
₹1,000
AGE(I)CG Jakhau
₹2.4 L
Yes
17 Aug 2021
31 May 2021
17 Jul 2021
31 May 2021
15 Jul 2021
15 Jun 2021
Amount
SCHEDULE "A" Part - I (BUILDING WORKS) Details of prepriced schedule is given in tender documents.
SCHEDULE "A" PART-II ( SITE CLEARANCE, EXCAVATION, & EARTHWORK) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-III (INTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IV (INTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-V (ROAD/PATH/HARDSTANDING) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VI (SEWAGE DISPOSAL) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VII (AREA DRAINAGE) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-VIII (EXTERNAL WATER SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-IX (EXTERNAL ELECTRIC SUPPLY) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART-X (WATER COOLER & AIR CONDITIONG) Details of prepriced Schedule is given in tender documents.
SCHEDULE "A" PART -XIII (MISCELLANIOUS ITEMS) Note:- This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col.' E ' signifies this fact only.
INTERNAL WATER SUPPLY S & F 15 mm Two way bib tap complete all as specified & directed.
INTERNAL ELECTRIC SUPPLY S & F of 24 W square shape fully diffused recessed mounted 2' X 2' LED luminaire with, metallic CRCA housing & powder coated body, initial luminous flux 3000 lm, luminous efficancy not less than 125 lm/W, initial CCT 6500 K, initial CRI greater than 80, initial chromaticity <5, L70B50 50000 hr, IP 20 and IK 02 protection, power factor not less than 0.90 and built-in driver conforming to IS 15885 (Part 2/Sec 13): 2012 complete with electrical connection through 3 core PVC insulated copper conductor unarmoured cable of suitable size from ceiling rose to the light fitting as specified and directed by engineer-in-charge. Make: BAJAJ Cat-Part No. 112774 BZRSQL 24W XE NW or equivalent model of Havells, Philips or Wipro
S & F of 36 W square shape fully diffused recessed mounted 2' X 2' LED luminaire with, metallic CRCA housing & powder coated body, initial luminous flux 3000 lm, luminous efficancy not less than 125 lm/W, initial CCT 6500 K, initial CRI greater than 80, initial chromaticity <5, L70B50 50000 hr, IP 20 and IK 02 protection, power factor not less than 0.90 and built-in driver conforming to IS 15885 (Part 2/Sec 13): 2012 complete with electrical connection through 3 core PVC insulated copper conductor unarmoured cable of suitable size from ceiling rose to the light fitting as specified and directed by engineer-in-charge. Make: BAJAJ Cat-Part No. 111904 BZRSQL 36W XL NW or equivalent model of Havells, Philips or Wipro
S & F 20 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: BAJAJ Cat-Part No. 112785 BCLAB 20W or equivalent model of Havells, Philips or Wipro
S & F 16 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: SYSKA Cat-Part No. SSK- RA1601- N or equivalent model of Havells, Philips or Wipro
S & F 10 W surface/wall mounted LED batten having high efficiency long life LED chips with luminous efficacy of > 100 lumen/W, independent isolated SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, polycarbonate diffuser, housed in powder coated white extruded aluminium channel housing and white coloured ABS end caps having input voltage 220- 240 V, input frequency 50- 60 Hz, PF > 0.95, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fixture complete all as specified and directed. Make: BAJAJ Cat-Part No. 112407 BCLSB 10 WH or equivalent model of Havells, Philips or Wipro
S & F 25 W LED Building security light having high efficiency long life LED module with SMD LED package mounted on MCPCB with high LED efficacy of ≥ 100 lumen/W, integral SMPS based constant current electronic LED driver with THD < 20%, surge voltage protection and other safety tests as per IS: 15885 (Part-2/Sec-13): 2012, IP 66 protection, high effiency polycarbonate cover with integrated lens housed in pressure die-cast aluminium alloy heat sink for effective thermal management, sturdiness, excellent corrosion resistance, separate optical and control gear compartment & top opening for easy maintenance, suitable for side entry, wall mounting with bracket 1.5 m long with including necessary electrical connection to the fixture with 3 core flexible Cu conductor cable of appropriate size and light grade GI pipe, including GI clamps, nuts, bolts & washers with two coats of synthetic enemal paint over a coat of red oxide primer complete all as specified and directed. Make: BAJAJ Cat-Part No. 169821 BCLST 25W LED I LED I or equivalent model of Havells, Philips or Wipro
S & F BEE five star rated BLDC energy efficient high-speed ceiling fan having 1200 mm blade sweep, air-flow not less than 215 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Havells Cat part No. ES-50 or equivalent model of Havells , Usha or Bajaj.
S & F BEE five star rated BLDC energy efficient high-speed ceiling fan having 1400 mm blade sweep, air-flow not less than 280 CMM, operating voltage 220-240 V and frequency 50 Hz, including a downroad of suitable size and electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fan complete all as specified and directed. Make: Havells Cat Part No Fusion 1400mm or equivalent model of crompton Usha or Bajaj.
S & F engery efficient non-metalic fresh air fan having blade sweep 250 mm, air delivery not less than 860 CMH, operating voltage 220-240 V and frequency 50 Hz, including electrical connection with 3 core flexible Cu conductor cable of appropriate size from ceiling rose to the fresh-air fan complete all as specified and directed. Make: Crompton Cat-Part No. VENTILUS 10" or equivalent model of Usha, Havells or BAJAJ
S & F vertical triple pole & neutral, double door, 6-way metallic modular distribution board conforming to IEC 61439-3, suitable for flush / surface mounting with provision for MCCB up to 250 A as incomer and SP/TP MCBs as outgoing, reversible metal door, fully insulated 250 A copper busbar for each phase, two fully insulated & shrouded neutral bars, two earthbars, cable ties for cable management, prefitted masking sheet, etc. having IK 09 & IP 43 protection complete all as specified and directed by engineer-in-charge. Make: Legrand, Schneider, L & T
S & F MCB for AC applications conforming to IS/IEC 60898-1-2002, having breaking capacity Icn = 10 kA, sliding bottom clamp, colour coded on/off indication on dolly, biconnect IP 20 protected lower terminals and sliding shutters, etc. complete all as specified and directed by engineer-in-charge. Make: Schneider, Legrand, Havells a) 6 A, SP MCB, C- curve
(b) 16 A, SP MCB, C- curve
(c) 20 A, SP MCB, C- curve
(d) 32 A, TP MCB, C- curve
(e) 32 A, FP MCB, C- curve
(f) 63 A, TP MCB, C- curve
(g) 63 A, FP MCB, C- curve
S & F 100 A four pole moulded case circuit breaker (MCCB), conforming to IEC 60947-2, having Ics = 100% of Icu = 25 kA, adjustable thermal setting (0.7 - 1 X In) and fixed magnetic setting with compression lug connectors and thermal magnetic trip unit (TMD) all complete as specified and directed. Make: Schneider, Legrand, Havells
M & L for earthing complete with galvanized steel earth plate electrode of 60 cm x 60 cm x 6 mm size, buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanised steel strip of size 32x6mm as earth lead, by means of bolts, buts, check nuts and washers of galvanised iron or steel, galvanized iron pipe of 40 mm diameter, connected to earthing test point, all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion and including excavation, earthwork, PCC earth pit of dimensions 550 mm X 550 mm (outer) and 300 mm X 300 mm (inner) and 250 mm deep, with a 10 mm thick CI cover, hinged to CI frame on ground level, GI watering pipe, funnel, etc. as all specified and directed.
SEWAGE DISPOSAL M & L for DWCPE Pipe 150 mm dia laid to slope in trenches jointed and tested complete all as specified.
EXTERNAL ELECTRIFICATION Supply , install, testing and commissioning LT Panel, Outdoor type dust and vermin proof, totally enclosed, platform mounted, factory made having front openable shutter, with locking arrangement made out of CRCA steel sheet 3.15 mm thick with MS angle iron frame work of size 40 mm x 40 x 6 mm thick, duly painted all as specified including necessary foundation bolts, PCC (1:2:4), type B-1 platform of suitable size for mounting the panel, suitable for 415 Volts, 50 Hz, three phase, 4 wire system with suitable insulated aluminium busbar of capacity not less than 200 Amps and shall be complete with internal wiring with copper conductor and including the following accessories:- (A) Main Incoming (i) MCCB conforming to IS: 13947 (Part-II), IEC-947, 4 pole, 100 Amps, 415 volts, 50 Hz, ruptunng capacity 25 KA, with adjustable thermal and fixed magnetic setting. 01 No. (ii) Multifunctional LED Panel meter to measure voltage, current, frequency, power, power factor, kWH, etc with all connected CTs, Accuracy Class 1.0 • 01 No. (iii) LED indicating lamps for RYB indication, Main ON, Standby Supply ON (5 lamps)· 01 Set (B) Main Outgoing (i) MCCB conforming to IS:13947 (Part-II), IEC-947, 4 pole, 32 Amps, 415 volts, 50 Hz, rupturing capacity 25 KA, with adjustable thermal and fixed magnetic setting · 03 No. (for AC and heavy load, Building lighting load and spare)
M & L for earthing complete with galvanized earth plate electrode in 60 cm x 60 cm x 6 mm thick buried directly in ground vertically at a depth not less than 2.25 meter below ground level with top edge of earth plate at depth not less than 1.5 mtr below ground level connecting to and including GI strip 32 mm x 6 mm by means of GI bolts, nuts, check nuts and washer light grade 40 mm dia GI protection pipe and connected to equipment, GI pipe medium grade 20 mm dia for watering and including funnel wire mesh, RCC pit cover and PCC 1 ;2:4 type B-1 including Rocksalt, charcoal, excavation and earth work disposal of surplus soil shown as plate No 3 of SSR part - I 1991 and all as specified complete. Note : - The unit rate quoted shall deemed to have included for GI protection pipe, GI earth strip up to 7.5 mtr, GI water pipe, wire mesh , funnel , excavation , RCC pit cover complete
WATER COOLER Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1.0 KVA including suitable fixing arragement complete all as directed by Engineer - In - Charge
AIR CONDITIONING Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5 % and of capacity 5 KVA including suitable fixing arragement complete all as directed by Engineer - In - Charge
nidhi construction co.
M/s Gujarat Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .