Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 CrAdmitted-Finance NOT AVAILABLE | ₹1.5 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.5 Cr+₹1.6 L (1.11%)Admitted-Finance | ₹1.5 Cr+₹1.6 L (1.11%) | L2 | Admitted-Finance |
| 3 | L3₹1.5 Cr+₹2.3 L (1.59%)Admitted-Finance | ₹1.5 Cr+₹2.3 L (1.59%) | L3 | Admitted-Finance |
| 4 | L4₹1.6 Cr+₹15.4 L (10.5%)Admitted-Finance B 157 MANSAROVAR GARDEN NEW DELHI 110015 | WEST | DELHI | 110015 | ₹1.6 Cr+₹15.4 L (10.5%) | L4 | Admitted-Finance |
| 5 | L5₹1.7 Cr+₹19.6 L (13.3%)Admitted-Finance | ₹1.7 Cr+₹19.6 L (13.3%) | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | NCI Global Infratech L4 | Sansun Contractors Pvt.Ltd L2 | M/s S.K.Industries L5 | Baljeet Builders and Interior Decorators L1 | VB ENGINEERS L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00NOTE: ITEMS MENTIONED AS 0 (ZERO) QUANTITY ARE RATE ONLY ITEMS. PLEASE QUOTE THE RATES FOR THOSE ITEMS. CIVIL WORKS | ||||||||
| 2.00 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
a) In cement mortar | 32 | CUM | 1,350 ₹43,200 | 350 ₹11,200 Lowest | 1,250 ₹40,000 | 400 ₹12,800 | 1,000 ₹32,000 |
| 3.00 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | 400 | Sqm | 48 ₹19,200 | 15 ₹6,000 Lowest | 35 ₹14,000 | 40 ₹16,000 | 35 ₹14,000 |
| 4.00 | Dismantling tile work in floors,walls and roofs laid in cement mortar including stacking material within 50 metres lead. a) For thickness of tiles 10 mm to 25 mm ( including removal of cement mortar from the walls ) | 800 | Sqm | 48 ₹38,400 | 50 ₹40,000 | 40 ₹32,000 Lowest | 40 ₹32,000 Lowest | 40 ₹32,000 Lowest |
| 5.00 | Dismantling steel work in hollow/Builtup sections including dismembering and stacking within 50 metres lead | 2,000 | Kg | 5 ₹10,000 | 10 ₹20,000 | 5 ₹10,000 | 5 ₹10,000 | 3 ₹6,000 Lowest |
| 6.00 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix | 10 | CUM | 1,800 ₹18,000 | 750 ₹7,500 | 1,500 ₹15,000 | 400 ₹4,000 Lowest | 1,000 ₹10,000 |
| 7.00 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. | 12 | CUM | 1,800 ₹21,600 | 1,800 ₹21,600 | 2,000 ₹24,000 | 400 ₹4,800 Lowest | 1,500 ₹18,000 |
| 8.00 | Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. | 79 | SQM | 48 ₹3,792 | 80 ₹6,320 | 150 ₹11,850 | 30 ₹2,370 Lowest | 60 ₹4,740 |
| 9.00 | Dismantling Plinth Protection including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. | 20 | SQM | 48 ₹960 | 40 ₹800 Lowest | 100 ₹2,000 | 40 ₹800 Lowest | 100 ₹2,000 |
| 10.00 | Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 5
0 meters lead as directed by Engineer-in-charge. | 25 | SQM | 18 ₹450 Lowest | 40 ₹1,000 | 35 ₹875 | 30 ₹750 | 50 ₹1,250 |
Tender Value
₹1.8 Cr
EMD Value
₹3.5 L
Closing Date
27 May 2024, 3:00 pmClosed
Principal
Sri Guru Gobind Singh College of Commerce, Opp TV tower, Pitampura New Delhi-110034
E-Tender for Civil and Interior Works
2024_DU_807410_1
SGGSCC/E-TENDER/2024-25/02
Open Tender
Civil Works
Works
180 days
SGGSCC
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
Principal Sri Guru Gobind Singh College of Commerc
₹3.5 L
26 Jul 2024
15 May 2024
28 May 2024
15 May 2024
27 May 2024
15 May 2024
Amount
NOTE: ITEMS MENTIONED AS 0 (ZERO) QUANTITY ARE RATE ONLY ITEMS. PLEASE QUOTE THE RATES FOR THOSE ITEMS. CIVIL WORKS
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. a) In cement mortar
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Dismantling tile work in floors,walls and roofs laid in cement mortar including stacking material within 50 metres lead. a) For thickness of tiles 10 mm to 25 mm ( including removal of cement mortar from the walls )
Dismantling steel work in hollow/Builtup sections including dismembering and stacking within 50 metres lead
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:3:6 or richer mix
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling Plinth Protection including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling aluminium/ Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 5 0 meters lead as directed by Engineer-in-charge.
Removal of toughened glass panel from existing window including stacking within 50 metres lead
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead : A) Of area 3 sq. metres and below
Dismantling of existing sanitary fittings and fixtures including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (existing admin block toilet)
Demolishing existing drain with drain cover including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Dismantling of existing Electrical light poles & Underground Electrical Cables including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. ( for construction of Ladies Toilet New Staff Room)
Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
Dismantling of Loose concrete cover from RCC beam, column & Slab using mechanical chisel including cleaning of concrete surface to remove any loose concrete at all heights/depths including scaffolding as required by the engineer in charge including stacking of serviceable materials and disposed of unserviceable materials upto a lead of 50 meters.
Dismantling of existing Wooden Cabinets including stacking of serviceable material and disposal of unserviceable material within 50 metres lead. (In Admin Office Area)
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. a) All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations , floor etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering-All level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete at all levels. Thermo-Mechanically Treated bars. (Only TATA Or SAIL). Thermo-Mechanically Treated bars of grade Fe-500D or more.
Centering and shuttering including strutting, propping etc. and removal of form for all works at all levels: Foundations, footings, bases of columns, Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. Suspended floors, roofs, landings, balconies and access platform , Lintels, beams, plinth beams, girders, bressumers and cantilevers, Columns, Pillars, Piers, Abutments, Posts and Struts, Stairs, (excluding landings) except spiral-staircases, Weather shade, Chajjas, corbels etc.,including Edges of slab and breaks in floor & wall. PLYWOOD FORM WORK.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 10mm dia.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 12mm dia.
RE-BAR WORK : Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars for sunshades/balconies including fixing the steel bars in position using using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make but excluding the cost of reinforcement, all complete as per direction of Engineer-In-Charge. 16mm dia.
Shotcreting RCC. columns, beams and slabs etc. in layers with approved design mix concrete having the specified minimum characteristic compressive strength [with ordinary Portland cement, coarse sand and graded stone aggregate of 10 mm maximum size in proportion as per design criteria] including the cost of centering and shuttering at edges and corners etc. as directed by Engineer in-Charge Note: Rates shall include the providing necessary ground wires etc. The levelling gauges, if used, shall be paid for separately. Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/ tapping with a blunt metal instrument. 50 mm thick in Grade M 25 with cement content not less than 330 kg per cum
Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make. (NITO BOND)
Micro Concreting- Providing and laying high strength free flow micro concrete (aggregate should be less that 10mm) over the repaired columns/ beams/ slabs etc. at all height and depths , cured, complete to the satisfaction of the engineer incharge. Formwork to columns shall be removed after 48 hours. Average thickness 32 mm.
Micro Concreting- Providing and laying high strength free flow micro concrete (aggregate should be less that 10mm) over the repaired columns/ beams/ slabs etc. at all height and depths , cured, complete to the satisfaction of the engineer incharge. Formwork to columns shall be removed after 48 hours. Average thickness 50 mm.
Providing & Fixing in position Metal Decking Sheets ( Pennar/ CRIL Deckspan/ Tata Bluscope/ inter arch roofing/ raj mohan) roofing 1.0 mm thk @ minimum 10.34 kg per sq.m for supporting RCC Slab (permanent shuttering) including edge trims cutting, trimming, fixing, leak proofing of joints etc. complete.
Providing, Supply and fixing of Shear Studs 19mm x 125mm
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:4 (1 cement : 4 coarse sand)
Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. Cement mortar 1:4 (1 cement :4 coarse sand)
Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry.
Providing & laying Brick bats using broken bricks Brick bats 25mm to 115mm compacted by mechanical means in required slope as per directions of engineer in charge.
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb area and along crack line including drilling of holes of required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required spacing and making the hole & crack dust free by blowing compressed air, sealing the distance between injection nipple with adhesive chemical of approved make and allow it to cure complete as per direction of Engineer-In-Charge.
Providing and injecting approved grout in proportion recommended by the manufacturer into cracks/honey-comb area of concrete/masonry by suitable gun/pump at required pressure including cutting of nipples after curing etc. complete as per directions of Engineer-in- Charge. (The payment shall be made on the basis of actual weight of approved grout injected.) Stirrer mixed SBR Polymer (of approved make) modified Cement slurry made with Shrinkage Compensating Cement in concrete/RCC work.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelling and dash fasteners to be paid for separately) : a) Anodised or Powder coated aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15 ( minimum 3mm thick aluminium section/Patam Door Frames of Jindal/Hindalco only)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber /neoprene gasket etc. complete (minimum 2mm thick aluminium section of Jindal/Hindalco only) Anodised or Powder coated aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15). Aluminium Doors and Windows shall be provided with EBCO make HANDLES. QUOTED Rates shall be inclusive of EBCO make handles.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge :With Toughened Glass of 6mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge : With Toughened Glass of 8mm thickness
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge : With frosted glass panes of 5.5 mm thickness.
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge : With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing 12 mm thick pre-laminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. Pre-laminated particle board with decorative lamination on both sides.
Filling the gap in between aluminium frame & adjacent RCC/ Brick/Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. Upto 5mm depth and 5 mm width
Providing and fixing ISI marked flush door shutters conforming to IS: 2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands finished with 1mm thick Laminate on both faces of shutter : (Flush door only of Duro / Green/ Century/ Virgo make and laminate only of Merino, Sundek, Century, Duro make) 35 mm thick including ISI marked 3 no's 4 inch long Heavy Duty Stainless Steel butt hinges with necessary SS screws complete
Extra for providing melamine polish finished C.P. teakwood lipping size 35 mm x 18 mm size on all four edges of flush door shutters (over all area of door shutter to be measured).
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to wooden frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand:6 graded stone aggregate 20 mm nominal size).
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing bright finished brass handles with screws etc. complete: EBCO/ HETTICH/ GODREJ/DORMA/DORSET makes only a) 125 mm
Providing and fixing bright finished brass 100 mm mortice latch and lock, ISI marked, with six levers and a pair of anodised (anodic coating not less than grade AC 10 as per IS : 1868) aluminium lever handles of approved quality with necessary screws etc. complete. HETTICH/ GODREJ/ EBCO/ DORMA/ OZONE/ GOLDEN LOCKS/DORSET make only.
Providing & Fixing 12mm HPL Board Toilet Partition as per approved color with all necessary Accessories: Standard – Stainless Steel a) SS Adjustable Leg b) SS Coat Hook c) SS Door Knob d) SS Lockset with indicator e) SS Hinge f) SS U channel g) SS Toprail h) SS Door stopper Channel j) Screws & Wall Plugs k) Noise Deafening tapes for grooves in doors & Pilasters ( Approved Makes : Greenlam Sturdo Series/ Merino Titan Standard Series/ Stylam Cuboid Series )
Providing and fixing 2' x 2' grid false ceiling (tiles and frame) at all heights of size 595X595mm of approved texture, design and pattern as per DSR 2021 item no.12.52.4 . 12.5 mm thick fully Perforated Gypsum Board tile made from plasterboard having glass fibre conforming to IS:2095 part I, of size 2'x2', having perforation of 9.7x9.7 mm at 19.4 mm c/c with center borders of 48mm and the side borders of 30 mm, backed with non woven tissue on the back side, having an NRC (Noise Reduction Coefficient) of 0.79, with 50 mm resin bonded glass wool backing. Heavy Duty T GRID OF - India Gysum 12mm thick high NRC Ceiling Tile of Armstrong , India Gypsum or Gyproc Make
Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per DSR 2021 item no.12.45.3 . 12.5 mm thick tapered edge gypsum moisture resistant board of Armstrong , India Gypsum or Gyproc Make
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 200mm in RCC beams, lintels, columns and slabs to introduce steel bars including fixing 16mm dia 200mm ANCHOR ROD of steel grade 5.8 (hilti/fisher make) in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make all complete as per direction of Engineer-In-Charge.
Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100mm upto 300mm in RCC beams, lintels, columns and slabs to introduce steel bars including fixing 20mm dia 300mm ANCHOR ROD of steel grade 5.8 (hilti/fisher make) in position using epoxy resin anchor grout of Hilty HIT-RE 500 V3 make all complete as per direction of Engineer-In-Charge.
Providing, fabricating and supplying and fixing panels of aluminium composite panel cladding in pan shape in metallic colour of approved shades made out of 4mm thick aluminium composite panel material consisting of 3mm thick FR grade mineral core sandwiched between two Aluminium sheets (each 0.5mm thick). The aluminium composite panel cladding sheet shall be coil coated, with Kynar 500 based PVDF / Lumiflon based fluoropolymer resin coating of approved colour and shade on face # 1 and polymer (Service) coating on face # 2 as specified using stainless steel screws, nuts, bolts, washers, cleats, weather silicone sealant, backer rods etc.
Supply and Installation of Modular Office Cupboards (Upto 600mm Deep) in existing NICHE Specifications: Size: As per site availability Shutter Thickness: 25mm thick pre-laminated HDF board (Greenlam, Virgo, Duro, or Bhutan Tuff) - approved finish Hardware, Handles and Locks: Godrej, Dorset, Dorma, Hettich, or Ebco make only Carcase Material: 18mm thick pre-laminated HDF board (Greenlam, Virgo, Duro, or Bhutan Tuff) - approved finish Shelves: Minimum 1 per 4 sq.ft. of cupboard space Handles: 125mm long Price shall be Inclusive of all labor and materials complete upto the satisfaction of the engineer incharge.
Providing PVC moulding / architrave for door frame/cupboard made up of extruded solid foam PVC profile having homogenous fine cellular structure with smooth outer integral skin, minimum 30 mm width and minimum 12 mm thick suitable for fixing to frame. The molding shall be snap fitted in the groove provided in the frame & fixed with PVC solvent adhesive/ cement and self tapping screws (of required size) complete as per direction of Engineer-in-Charge.
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for Flooring, kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade (Basic cost Rs. 110 per sqft) Area of slab over 0.50 sqm
Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete
Providing and laying Ceramic Rectified floor tiles of size 600 x 600mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colors, laid on 20 mm thick cement mortar 1:4 (1 Cement: 4 Coarse sand), including grouting the joints with white cement and matching pigments etc. complete. . Basic cost of tile Rs. 50/- per sqft
Providing and fixing Ist quality rectified ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. Basic Cost of Tile Rs. 50/- per sqft
Extra for Fixing glazed/ Ceramic/ Vitrified floor/wall tiles with quick-set tile adhesive of MYK LATICRETE.
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :25 mm thick
52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer's specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75mm deep chase
Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete.
Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc as per DSR 2021 item no.22.7.1. With average thickness of 120 mm and minimum thickness at khurra as 65 mm.
Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) after surface preparation, first layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. (b) laying second layer of Fibre glass cloth when the first layer is still green. Overlaps of joints of fibre cloth should not be less than 10 cm. (c) third layer of 1.5 mm thickness consisting of slurry of cement @ 1.289 kg/sqm mixed with water proofing cement compound @ 0.670 kg/sqm and coarse sand @ 1.289 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on wall and tucked into groove in wall all around. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
SHEET ROOFING WORK: Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofing up to any pitch, including fixing with polymer coated 'J' or 'L' hooks, bolts & nuts 8mm dia. G.I plain/bitumen washers complete but excluding the cost of purlins, rafters, trusses etc. The sheets shall be manufactured out of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violet stabiliser in resin system under approximately 2400 psi and hot cured. They shall be of uniform pigmentation and thickness without air pockets and shall conform to IS 10192 and IS 12866.The sheets shall be opaque or translucent, clear or pigmented, textured or smooth as specified. 2 mm thick corrugated (2.5" or 4.2" or 6") or step-down (2" or 3" or 6" ) as specified.
Providing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 1.00 mm thick with zinc coating not less than 275 gm/m²
Extra for straight cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter for chimney stacks, sky light etc.: 1.00 mm thick
Extra for circular cutting in C.G.S. sheet roofing for making opening of area exceeding 40 sq. decimeter: 1.00 mm thick
Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per approved drawings and direction of Engineer-In-Charge. The joints shall be of extruded aluminum base members with, self aligning and self centering arragement support plates asper ASTM B221-02. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system that is capable of accommodating multidirectional seismic movement without stress to its components. System shall consist of metal profile that incorporates a universal aluminum base member designed to accommodate various project conditions and roof treatments. The cover plate shall be designed of width and thickness required to satisfy movement and loading requirements and secured to base members by utilizing manufacturer’s pre-engineered self-centering arrangement that freely rotates / moves in all directions. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminum extrusion cavity to allow freedom of movement and flexure in all directions including vertical displacement. The Joint System shall resists damage or deterioration from the impact of falling ice, exposure to UV, airborne contaminants and occasional foot traffic from maintenance personnel. Provision of Moisture Barrier Membrane in the Joint System to have water tight joint is mandatory requirement. (Material shall confirm to ASTM 6063). Roof Joint of 100 mm gap
Supplying and applying pre tested and approved water based concrete curing compound to concrete/ masonry surface, all as per manufacturer’s specification and direction of Engineer-in-charge. a) Non pigmented wet curing compound
Providing and fixing factory made precast RCC drain covers,having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineerin-charge.
12 mm cement plaster of mix (Brick work shall be provided with PVC chicken wire mesh on either side before plastering) 1:3:3 (1 cement: 3course sand: 3 fine sand)
18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). (Brick work shall be provided with PVC chicken wire mesh on either side of joints before plastering)
Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.
6 mm cement plaster 1:3 (1 cement : 3 fine sand) finished with a floating coat of neat cement and thick coat of Lime wash on top of walls when dry for bearing of R.C.C. slabs and beams
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1cement: 4 coarse sand)
External painting works: External painting works at all heights and levels as per procedure mentioned including 1) Surface preparation (scrapping, sanding, cleaning) 2) A liberal coat of Wall Primer as per manufacturers specification 3) Painting 2 or more coats of Exterior Weather Proof Paint in various colors (Asian/ ICI /Shalimar/ Berger/ Nerolac) 4) Horizontal surfaces like the tops of chajjas and parapets must be given an additional coat for greater protection Contractor’s scope includes all materials, tools & plants, paint brushes & rollers of approved makes, ropes, lifts, ladders, safety equipment’s, scaffolding and all other equipment’s as may be required to complete the works successfully. (The rates include all labour, materials and items of work required to complete the work successfully up to the satisfaction of the owner)
Internal painting works: Internal painting works at all heights and levels as per procedure mentioned including 1) Surface preparation (scrapping, sanding, cleaning) 2) One coat of Wall Primer as per manufacturers specification 3) Coat of White cement based putty (JK/BIRLA) 4) One liberal coat of wall primer over wall putty 5) Painting 2 or more coats of Premium acrylic emulsion of interior grade, having VOC content less than 50 grams/ litre in various colors (Asian/ ICI /Shalimar/ Berger/ Nerolac) Contractor’s scope includes all materials, tools & plants, paint brushes & rollers of approved makes, ropes, lifts, ladders, safety equipment’s, scaffolding and all other equipment’s as may be required to complete the works successfully. (The rates include all labour, materials and items of work required to complete the work successfully up to the satisfaction of the owner)
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/ 10 sqm over an under coat of primer applied @ 0.80 ltr/ 10 sqm of approved brand and manufacture. Approved make: Asian, Dulux, Nerolac, Berger.
Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
SHEET CLADDING WORK: Providing & fixing at all heights, levels and locations colour finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss/Frame members in slope or required pitch or curvature with Hex cap headed self-drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/framework shall be paid separately). 0.71 mm, Aluminium Color coated troughed profile with center to center pitch of 200 mm, depth of 32 mm, overall profile width1092 mm, cover width 1000mm. Approved makes: JSW COLOURON PLUS, TATA BLUESCOPE, HINDALCO EVERLAST.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer- in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective ofduration of scaffolding. Note: - This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done.
Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube posts/horizontal members/bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with 30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for traffic diversion such as traffic signals during construction at site for day and night, glow lamps, reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading provided shall be retained in position at site continuously i/c shifting of barricading from one location to another location as many times as required during the execution of the entire work till its completion. Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and works required to execute the job. The barricading shall not be removed without prior approval of Engineer?in-Charge. (Note :- One time payment shall be made for providing barricading from start of work till completion of work i/c shifting. The barricading provided shall remain to be the property of the contractor on completion of the work)
Auto glow/Night Glow Signage :- Design, Composition, Supply & Installation of Digitally printed auto glow film on HP Latex Printer with gloss vinyl pasted on 3mm acrylic sheet and fixing with SS Mirer screw/Double sided tap. Size 600mm x 300mm
Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineerin -charge AS PER DSR 2021 ITEM NO. 26.91 (Note: RATES TO BE INCLUSIVE OF necessary SS fasteners and SS screws )
Providing and fixing “dovetex” or equivalent tiles for external wall cladding to match the size, Texture and colour, of the tiles used in the existing building. Wall surface should be given a coat of 12 mm to 15 mm thick cement plaster (1: 5). 1 cem : 5 coarse sand and to fix the tiles with 6 mm thick cem. mortar 1 : 3 ( 1 cement : 3 coarse sand) while the base plaster is still fresh (i.e. within 24 hours.)
Providing and laying 60mm thick factory made cement concrete interlocking paver block of M -30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of Engineer-in-charge..
Wiring for the light points with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires of approved make in concealed or surface mounted 25 mm dia 16 gauge MS Conduit including providing and fixing of 6 amps single pole modular switch of approved quality colour make & design in 1.6 mm thick GI box and earthing of fixtures and the outlet box with 1.5 sq.mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) a) Primary point
Wiring for the light points with 1.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible FRLS wires of approved make in concealed or surface mounted 25 mm dia 16 gauge MS Conduit including providing and fixing of 6 amps single pole modular switch of approved quality colour make & design in 1.6 mm thick GI box and earthing of fixtures and the outlet box with 1.5 sq.mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) Secondary point (Controllling switch and GI box included in item no. 1)
Wiring for 250 volts single phase and neutral 16 amps modular switch socket outlet with universal pins with 3 x 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) Primary point for 16 amps switched socket outlet
Wiring for 250 volts single phase and neutral 16 amps modular switch socket outlet with universal pins with 3 x 4 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 4 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. (including circuit wiring from DB to switch Board) secondary point looped with primary point
Wiring for 250 volts single phase and neutral 6 amps modular switch socket outlet with universal pins with 3x2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 6/16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 2.5 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. Primary point for 6 amps switched socket outlet
Wiring for 250 volts single phase and neutral 6 amps modular switch socket outlet with universal pins with 3x2.5 sq.mm PVC insulated copper conductor 1100 volts grade stranded flexible "FRLS" wire in concealed or surface mounted 25 mm dia 16 gauge MS conduit / existing raceway including providing and fixing of 6/16 amps 3 pin modular switched sockets of approved make and design in 1.6 mm thick GI box with grid plates and earthing the third pin of each socket outlet with 2.5 Sq mm PVC insulated copper conductor stranded flexible "FRLS" wire. secondary point looped with primary point
Wiring for Exhaust fan point with 1.5 sq. mm. insulated copper conductor 1100 volts grade stranded flexible "FRLS" wires of approved make in concealed or surface mounted 25 mm dia 16 guage MS Conduit including providing and fixing of 6 amps flush mounted switch at the normal switch level in 2 mm thick GI box and 6 amps 3 pin flush mounted socket near exhaust fan and earthing of exhaust fan through the third pin of the socket outlet and GI box with 1.5 sq. mm. PVC insulated copper conductor flexible "FRLS " wire.
Providing and fixing in position the following 2mm thick FRLS PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design. 20 mm dia FRLS PVC conduit
Providing and fixing in position the following 2mm thick FRLS PVC rigid conduits concealed or exposed as called for including all accessories i.e. bends, junction boxes, with cover plates of approved make and design. 25 mm dia FRLS PVC conduit
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class pvc conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire.
Supplying of following 1100 volt grade XLPE FRLS insulated PVC sheathed copper conductor armoured cable as per specification. 4 core 16 sq.mm
Supplying of following 1100 volt grade XLPE FRLS insulated PVC sheathed copper conductor armoured cable as per specification. 4 core 6 sq. mm
Supplying of following 1100 volt grade XLPE FRLS insulated PVC sheathed copper conductor armoured cable as per specification. 3 core 6 sq. mm.
Supply, installation, testing and commissioning of the following cubicle type 1.6 mm thick CRCA sheet steel enclosed and partitions to segregate phases recessed in wall or surface mounted final distribution boards of the following description. Distribution board shall be powder coated and double door construction and in four tier configuration. 6 way TPN DB with 12 No 10/16/20/32 amps SP MCB as outgoing and 3 No. 32 amps DP RCCB’s of 100 mA leakage current including 1 No. 16 amps 4 Pole MCB as incomer & separate neutral link for each phase and earth bar.
Supply, installation, testing and commissioning of the following cubicle type 1.6 mm thick CRCA sheet steel enclosed and partitions to segregate phases recessed in wall or surface mounted final distribution boards of the following description. Distribution board shall be powder coated and double door construction and in four tier configuration. 8 way, Double door TPN DB with 12 No 10/16/20/32 amps SP MCB as outgoing and 3 No. 32 amps DP RCCB’s of 100 mA leakage current including 1 No. 16 amps 4 Pole MCB as incomer & separate neutral link for each phase and earth bar.
Supplying, fixing, testing and commissioning of 8 SWG GI wire including all necessary fixing accessories and effecting connections.
Chemical Earthing with 3mtr. long 250 Microne Copper bonded UL listed Rod including accessories and providing masonary enclosure with cover plate having locking arrangement and 50Kg. Chemical etc as required.
Providing and fixing 25mm x 5 mm G.I strip on surface or in recess for connections etc. as required.
Supply, installation, testing and commissioing of Propeller fan upto 300 mm sweep of approved make complete with louvars and all accessories as required.
Supply, installation, testing and commissioing of the following lighting fixtures and fans with all fixing accessories etc. as required. IP 66 10 watt LED Bulk Head Luminarie made up of high pressure die cast aluminium housing with polycarbonate cover having symmetric optics with minimum 600 lumens output system (Havells HEXAFT10WLED857SSYMBOPC or approved equivalent in Wipro/ Philips)
Supply, installation, testing and commissioing of the following lighting fixtures and fans with all fixing accessories etc. as required. Recessed mounted 15 watt LED down lighter made up of high pressure die cast aluminium housing complete as required. ( Havells INTEGRANEODLR12WLED840S or approved equivalent in Wipro/ Philips)
Supply, installation, testing and commissioing of the following lighting fixtures and fans with all fixing accessories etc. as required. Philips Motion Sensing 20w Led Batten or approved equivalent from WIPRO / Havells.
Supply, installation, testing and commissioing of the following lighting fixtures and fans with all fixing accessories etc. as required. Supply of 1200 mm long 20 watt LED luminiare (PHILIPS SMART BRITE BATTEN BN 100C LED or approved equivalent from WIPRO, HAVELLS)
Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
Providing and fixing white vitreous china extended wall mounted water closet of size 620X 355X745mm of approved shape including providing and fixing of white vitreous china cistern with dual flushing fitting of flushing capacity 3 liter/6 liters (Adjustable to 4liter/8liters) including sheet cover , and cistern fittings, nut bolt gasket etc complete. Wall hung EWC (Hindware Cornice E.W.C & Cistern Suit Cat. No.20096(P-15) & 21056 of size 790x370x710 or approved equivalent)
Providing and fixing wash basin with C.I. Brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls whereever require : Providing and fixing Round Washbasin size 490mm dia Hindware in counter basin Cat No.-10052 or approved equivalent, CP brass single lever mixer fitting with pop-up waste Hindware Cat. No.F310014 or approved equivalent.
Providing and fixing uplasticised PVC connection pipe with brass unions : 45 cm length a)15 mm nominal bore
Providing and fixing C.P. brass angle valve for basin, wc points of approved quality conforming to IS:8931 (Make Hindware, Code:F850073 ) a) 15 mm nominal bore
Bib Cock: Providing and fixing in position 1 Way bib cock C.P. brass to IS:8931 (Make Hindware, F520004 )
Providing and fixing toilet paper holder of approved quality conforming to IS standards. (Make : Hindware, Code:F880003 )
Providing and fixing of CP brass Health faucet for wc with 8mm dia 1.25mtr. Long pipe and wall hook fixed to wall with rawl plug and CP brass screws complete.(Make Hindware, Code: F160110 )
Providing and fixing white vitreous china flat back half stall urinal with white consealed P.V.C flushing cistern with pressmetic valve of hindware make , with fittings, standard size concealed pipe, spreaders with unions and clamps (all in C.P brass) with waste fitting as per IS : 2556, C.I trap with outlet grating and other coupling in C.P brass including painting of fittings and cutting and making good the walls and floors whereever required (Make :CERA CALORIGO Cat No. : S4020114 Urinal 310 x 300 x 555 mm)
Providing & fixing TOUGHENED GLASS HINDWARE WALL HUNG URINAL DIVISION 450 X 900 MM X 8 mm: SU81OSC(C)-STD-CR
Providing and fixing automatic soap Dispenser Kimberly-Clark Professional® Aquarius® Skin Care Dispenser (69480), Hand Soap and Sanitiser Dispenser, 1 Dispenser / Case AQUARIUS® PRODUCT CODE #69480
Providing and fixing PTMT angle stop cock 15mm nominal bore,weighting not less than 85gms.
Providing and fixing 350mm bottle trap without drain in polished chrome of approved quality & make and as per the direction of Engineer- in-charge. (Make Hindware, Code:F850003 or approved equivalent from CERA)
Floor Trap / Drain: Providing and placing in position Cockroach Floor Trap / Drain in nickel bearing stainless steel compliance to Hindware/ Kohlar make floor drain cover consisting of grating frame, inner filter and outer filter of apropriate size as per approved by site incharge / consultant complete as required
Providing and fixing Janator sink with C.I. brackets, C.P. brass chain with rubber plug 40mm C.P. brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete including painting of fittings and brackets, cutting and making good the wall wherever required: NK SB1 M SIZE: 610 X 460 X 255
Providing and fixing 6mm thick toughened glass mirror of size 900mm x 1200mm including making suitable holes in the mirrors and fixing and mounting the mirror on the wall with suitable Stainless steel mounts of approved makes complete upto the satisfaction of the engineer incharge.
Providing and fixing mirror of superior glass of (ASAHI/SAINTGOBAIN/MODI make) and of required shape and size with plastic molded frame of approved make and shade with 6 mm thick hard board backing 450mm X 1500mm
Providing & fixing 6 mm thick SS grating with rim of approved design including setting in floor with cement mortar to match with floor finish as per approved by engineer incharge. (For floor trap/ urinal trap).125 mm dia
Providing and fixing floor drain with 65mm x 50 mm GI Elbow with cement mortar compelete in all respect
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 [Class-1] pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 [Class-1] pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 [Class-1] pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 25 mm nominal bore
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 [Class-1] pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 32 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 [Class-1] pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal outer dia Pipes
Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) : 25 mm nominal bore
Providing and fixing gun metal gate valve with C.I. wheel of approved quality(screwed end) : 40 mm nominal bore
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with sealring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,including all accessories including T, Bend, inlet mouth,PVC pipe clips etc. complete. (i) Single socketed pipes. A)110 mm diameter
Soil Waste & Waste Water: Providing, placing in position and fixing PVC SWR Pipe with rubber ring and SWR fittings [coupler, sand @45, bend with door, doubly, single tee, reducing tee, reducing coupler, singley, door cap, single tee, double tee, rubber ring extra, offset band, pipe clamp] Compliance to IS : 14735 on elevation [vertical wall cladding / stacking] of approved make of following diameter. 110mm dia nominal outer diameter
Soil Waste & Waste Water: Providing, placing in position and fixing PVC SWR Pipe with rubber ring and SWR fittings [coupler, sand @45, bend with door, doubly, single tee, reducing tee, reducing coupler, singley, door cap, single tee, double tee, rubber ring extra, offset band, pipe clamp] Compliance to IS : 14735 on elevation [vertical wall cladding / stacking] of approved make of following diameter. 50mm dia nominal outer diameter
Soil Waste & Waste Water: Providing, placing in position and fixing PVC SWR Pipe with rubber ring and SWR fittings [coupler, sand @45, bend with door, doubly, single tee, reducing tee, reducing coupler, singley, door cap, single tee, double tee, rubber ring extra, offset band, pipe clamp] Compliance to IS : 14735 on elevation [vertical wall cladding / stacking] of approved make of following diameter. 40mm dia nominal outer diameter
Soil Waste & Waste Water: Providing, placing in position and fixing PVC SWR Pipe with rubber ring and SWR fittings [coupler, sand @45, bend with door, doubly, single tee, reducing tee, reducing coupler, singley, door cap, single tee, double tee, rubber ring extra, offset band, pipe clamp] Compliance to IS : 14735 on elevation [vertical wall cladding / stacking] of approved make of following diameter. 32mm dia nominal outer diameter
Soil, Rain & Waste Water Pipe on Ground Floor: Providing, placing in position and fixing PVC SWR pipe Type-B Compliance to IS - 13592 with rubber ring and SWR fittings [coupler, sand @45, bend with door, doubly, single tee, reducing tee, reducing coupler, singley, door cap, single tee, double tee, rubber ring extra, offset band, pipe clamp] Compliance to IS : 14735 resting in plan on 75mm thick and 250mm wide in cement concrete [1:2:4 mix (1 cement : 2 coarse sand : 4 stone aggregate of 10mm and down size)] bed and all around encasing, plastering with 1:3 cement mortar, back filling the excavated earth, watering, ramming complete and on elevation [vertical wall cladding / stacking] of approved make with gradient between 1 in 40 to 1 in 110 in plan as the case of following diameter. 160mm dia nominal outer diameter
Soil, Rain & Waste Water Pipe on Ground Floor: Providing, placing in position and fixing SWR pipe Type-B Compliance to IS - 13592 with rubber ring and SWR fittings [coupler, sand @45, bend with door, doubly, single tee, reducing tee, reducing coupler, singley, door cap, single tee, double tee, rubber ring extra, offset band, pipe clamp] Compliance to IS : 14735 resting in plan on 75mm thick and 250mm wide in cement concrete [1:2:4 mix (1 cement : 2 coarse sand : 4 stone aggregate of 10mm and down size)] bed and all around encasing, plastering with 1:3 cement mortar, back filling the excavated earth, watering, ramming complete and on elevation [vertical wall cladding / stacking] of approved make with gradient between 1 in 40 to 1 in 110 in plan as the case of following diameter. 110mm dia nominal outer diameter
Providing & fixing square mouth S.W Gully Trap & Catch Basin class SP-1 complete with C.I gratting brick masonry chamber with water tight C.I cover with frame of 300x300mm size (inside) the weight of cover to be not less thn 4.50 kg and frame to be less than 2.70 kg as per standard design :
Constructing brick masonry manhole in cement mortar 1:4 (1 cement : 4 coarse sand ) with R.C.C top slab with 1:2:4 mix (1 cement :2 coarse sand :4grade stone aggregate 20 mm norminal size) foundation concrete 1:4:8 (1 cement :4 coarse sand :8 grade stone aggregate 40 mm norminal size) inside p lastering 12 mm thick with mortar 1:3(1 cement : 4 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4)1 cement :2 coarse sand :4grade stone aggregate 20 mm norminal size) finished with a floating coat of neat cement complete as per standard design : Inside size 900x800 mm and 45 cm deep including CI cover with frame (light duty ) 455x610 mm internal dimensions, total weight cover and frame not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ): With common burnt clay F.P.S (non modular) brick of class designation 7.5
Making connection of drain or sewer line with existing manhole including breaking into and making good the walls, floors with cement concrete 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) cement plastered on both sides with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement and making necessary channels for the drain etc. complete : For pipes 100 to 250 mm diameter
Sansun Contractors Pvt.Ltd
VB ENGINEERS
NCI Global Infratech
M/s S.K.Industries
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.39 MB
BOQ_848626.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .