Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance AT POST NANDGAON PODE TAH BALLARPUR DIST CHANDRAPUR | BALLARPUR | CHANDRAPUR | MAHARASHTRA | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹2.2 L
EMD Value
₹2,720
Closing Date
24 Nov 2022, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SAE, GSA
PO-Rajura, Dt-Chandrapur Maharashtra
Shifting of 11KV, 3.3KV and lighting lines near PWD road junction at Gouri-Pauni Merger scheme
2022_WCL_262708_1
ba3612-enm-0038-2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Gouri Sub Area
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,720
Yes
25 Nov 2022
18 Nov 2022
25 Nov 2022
18 Nov 2022
24 Nov 2022
18 Nov 2022
18 Nov 2022 - 21 Nov 2022
Amount
(The bidder to quote rates excluding GST . The bidders may note this while bidding for this tender. )
Supplying and erecting R.S.Joint(Girder)poles 100 x 116mm(23Kg/ m) with provided base plate in prescribed foundation as per specification No. OH-PL/Rs(11 Mtr. Long)
Making cement concrete foundation including excavation (60x60)cmx deep 1/6 of pole length in 1:3:6 cement concrete 20x25mm stone metal, 45cmx 45cm x45x /45cm dia x45cm. height plinth duly plastered, with necessary curing and finishing complete (for above 9m poles)
Supplying and erecting vee cross arm with ISM channel of 75x40x6mm, for 11kV HTOH line with arrangement to fix insulatorat 45mm from the end & horizontal distance between insulators1220 mm bent at angle of 60 degree keeping base 305 mm and thetotal vertical height of V cross arm as 460mm, and fixed on pole withMS clamp of 80x10 mm, nut bolts,washers complete as perspecification no. OH-PL/VCA
Supplying 100x50 mm with 4.7 mm thick web and 7.5 mm thick flange channel iron cross arm of suitable length for 2.4 m wide DP structure and erecting on DP with 50x6 mm clamp as per approved method of construction and complete as per specification No. OHPL/BKT
Supplying and erecting bracket for guarding, made from channel iron 1600 mm in length and 65x65x6 mm thick web and 7.3 thick flange erected on pole as per specification No. OH-PL/VCA
Supplying and erecting porcelain pin type insulator with nut bolts suitable for 11 kv line, complete as per specification no. OH-INS/PST
Supplying and erecting porcelain disc insulator suitable for 11 KV line, complete as per specification No. OH-INS/DI
Supplying and erecting ACSR conductor of size 6/1-3.66 mm complete.(Mink) (255 kg/km) as per specification no. OHCON/ ACSR
Supplying and erecting ACSR conductor of size - 6/1-4.72 mm (Dog) complete. (394 kg/km) as per specification no. OHCON/ ACSR
Supplying and erecting GI stay set for poles, including loop insulators at inaccessible height complete with anchor plate 300 x 300 x 6 mm, straining screws, GI stay wire 7/8 SWG, GI stay rod 20 mm x 1.8 m length and pole clamps duly erected in provided cement concrete foundation
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EAEP
Supplying and erecting hard drawn G.I. wire 8 SWG complete erected for overhead line with proper size of G.I. wire for binding with jumpering etc. (As per CSR 2017-18)
Supplying and erecting 75x40x6 mm with 4.4 mm thick web and 7.3 mm thick flange channel (top pin) with clamp of suitable length so as to maintain vertical clearance of 1065 mm for 11 kV,1320 mm for 22 kV between insulators for erection of top pin insulators complete as per specification no. OH-PL/VCA
Supplying and erecting guarding loop using G.l. wire no.8 SWG forL.T. overhead line of horizontal formation complete erected with20 SWG GI wire as binding wire and 50 mm. section on eachside, complete
Dismantling the existing pole above 6 m height with brackets, clamps, insulators, stay from the cement concrete foundation and making the site clear by refilling the pits with excavated materials and bringing it to the ground level.
Dismantling the existing overhead line including G.I. wires of all sizes without damaging & making the coils in suitable sizes
Total impact of GST for the purpose of CTC
P R Electricals
A K SURYAWANSHI
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .