| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹24.1 L+₹74,140 (3.17%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L2 | Rejected-Finance Higher bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical Not Recommended as not enlisted in b(ii) category |
Tender Value
₹24.9 L
EMD Value
₹49,800
Closing Date
5 Nov 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
SH A K SINGH SE CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
UPKEEP OF EM INSTALLATIONS INCLUDING CONNECTED ITEMS AT NOFRA AREA UNDER GE GOMANTAK VASCO
2021_MES_466014_2
85453/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹49,800
Yes
1 Jan 2022
21 Oct 2021
8 Nov 2021
21 Oct 2021
5 Nov 2021
22 Oct 2021
60 days
Amount
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5m in depth getting out in hard/dense soil for laying and taking down UG cable any size complete all as specified and as directed
Excavation in trenches not exceeding 1.5 m width and not exceeding 1.5 in depth getting out soft disintegrated rock for laying and taking down UG cable of any size. Complete all as specified and as directed
M & L for sand cushion in trenches for cable protection complete all as directed and specified.
Supply and lay PCC cable cover class LV type I flat size 250mm x150mmx40mm all as directed and specified.
Supply and lay PCC cable cover class HV, type 1, flat size 300mm x 180mm x 40mm with ISI mark.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil. Complete all as specified and as directed
Removal of surplus soil to a distance not exceeding 50 m and depositing where directed all as specified and as directed
Supply and laying HT XLPE cable insulated , screened, PVC bedded , galvanised steel strip armoured, electric power cable (Heavy duty) with aluminium conductor, cross sectional area 95 Sqmm 3 core 11KV grade, including taking down of existing old cable complete all as specified and as directed
Taking down existing LT UG XLPE cable of followings sizes:-
(a) 50 Sqmm 3.5 Core
(b) 70 Sqmm 3.5 Core
(c) 95 Sqmm 3.5 Core
(d) 185 Sqmm 3.5 Core
(e) 240 Sqmm 3.5 Core
Laying only LT UG cable XLPE insulated armoured heavy duty 1100 volts grade with aluminium conductor multistandarded including centre gland, lugs, jointing materials etc laid in trenches or fixed it to wall of following sizes:- Note: Cable will be issued under schedule 'B' free for fixing/laying by the department & Contractor will collect the cable from storeyard of GE Gomantak Vasco .The rate of transportation & loading /unloading of cable is deemed to be included under quoted rate.
(a) 50 Sqmm 3.5 Core
(b) 70 Sqmm 3.5 Core
(c) 95 Sqmm 3.5 Core
(d) 185 Sqmm 3.5 Core
(e) 240 Sqmm 3.5 Core
M&L for GI tubing light grade for the protection of cable all as specified and as directed.
(a) 40 mm diameter
(b) 50 mm diameter
(c) 80 mm diameter
M&L for High density polyethylene pipes (HDPE) of pressure rating PN 6 (SDR 21) laid in trenches for cable protection complete all as specified and as directed of following sizes:-
(a) 40 mm diameter
(b) 50 mm diameter
(c) 90 mm diameter
(d) 110 mm diameter
M & L Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old burnt cable joint termination all as specified and as directed.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for outdoor end termination complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm including taking down old burnt cable joint terminationall as specified and as directed.
M & L Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 to 120 sqmm including taking down old burnt cable joint termination all as specified and as directed.
M&L for straight through joints (Epoxy) for UG cable including joint kits and labour complete for making joints suitable for 35 to 95 sqmm, 3.5 core, 1100 V grade cable. Complete all as specified and as directed.
All as per Item No.16 here in before, but for 120 to 150 sqmm 3.5 core, 1100 V grade cable complete all as specified and as directed
Supply & fixing MCCB 400 Amps, 36kA, 4 pole, 415 Volts, 50 Hz including taking down old one complete all as specified and as directed
Supply & fixing MCCB 250 Amps, 25kA, 4 pole, 415 Volts, 50 Hz including taking down old one complete all as specified and as directed
Supply & fixing MCCB 160 Amps, 16kA, 4 pole, 415 Volts, 50 Hz including taking down old one complete all as specified and as directed
Supply & fixing MCCB 100 Amps, 16kA, 4 pole, 415 Volts, 50 Hz including taking down old one complete all as specified and as directed
Material and labour for preparation of old painted surface of feeder pillar box/LT panel by removing all dust etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including of identification etc all as specified and as directed.
Disconnecting HT/LT cable and earthing connections of burnt/defective transformer of capacity 500 to 800 KVA , 11 KV/433 volts 3 phase from pole/floor mounted, taking from site of installation carefully with the help of Crane and transportation of the same to workshop for repairs, draining out the transformer oil, dismantling complete and taking out the core assembly and removing burnt out windings, dehydrating the core assembly, reassembling transformer after repair, replacement of complete gasket set, refilling the oil duly filtered / dehydrated, topping up with new oil, carrying out routine tests, welding work, leakage repairing and complete servicing including transportation back to site, testing and commissioning of the repaired transformer at site on full load after making cable and earthing connections complete all as specified and as directed. Note :- New transformer oil, Dehydration of transformer oil, LT /HT bushings/studs shall be measured and paid separately.
All as per item No 23 here in before, but for 400 KVA all as specified and as directed.
All as per item No 23 here in before, but for 125 to 200 KVA all as specified and as directed.
M&L for rewinding in repair of HT winding with Copper strip of suitable size/gauge, fixing the coil in position in core assembly and making connection as per original pattern including providing insulation, varnish, all as specified and as directed
(a) Transformer 500 - 800 KVA capacity
(b) Transformer 400 KVA capacity
(c) Transformer 125 - 200 KVA capacity
All as per item No. 26 here in before, but for LT limbs of following capacities :-
(a) Transformer 500 - 800 KVA capacity
(b) Transformer 400 KVA capacity
(c) Transformer 125 - 200 KVA capacity Notes for item No 26 & 27 : Guarantee of two years shall be provided by the contractor for rewinded limb.
S&F in repairs brass metal studs nut & washers suitable for 11 KV HT side of transformer upto 800 KVA all as specified and as directed
S&F in repairs brass metal studs nut & washers suitable for 11 KV LT side of transformer upto 800 KVA all as specified and as directed
S&F in repairs HT bushing suitable for upto 800 KVA Transformer complete all as specified and as directed
S&F in repairs LT bushing suitable for upto 800 KVA Transformer complete all as specified and as directed
S & F Temperature gauge suitable size for transformer of capacity 800 KVA all as specified and as directed
Supply and fill in repairs existing breather silica gel of superior quality for transformer breather all as specified and as directed
S&F in repairs transparent PVC material breather assembly for transformer upto 800 KVA capacity all as specified and as directed
M & L for transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine to remove impurities from oil such as moisture, dirt, air and other gases and to improve BDV upto 50KV at 2.5mm air gap all as specified and as directed. Note: Transformer oil filtration & dehydration by Ultra High Vacuum Double stage machine shall be done on existing installation place on same day.
M&L for new transformer oil for topping up or for replacement in Transformers /Servo Voltage stabilizer complete all as specified and as directed. Note: Oil shall be in company sealed barrel having BDV not less than 60 KV
M &L for Dismantling top cover, lifting complete core assembly of transformer taking out old gasket set and drain out existing complete oil servicing of complete transformer, painting inner surface replacing nuts bolts complete as required and reassemble the transformer including testing and installation at site for upto 800 KVA transformer all as specified and as directed. Note :- Oil, and HT/LT bushing shall be measured and paid separetly
M & L for preparation of old painted surface of installation by removing all dirt, dust, grease, oil etc and painting complete surface including connected accessories with one coat of synthetic enamel paint of approved colour including writing of identification Nos, capacity etc of transformers upto 800 KVA all as specified and as directed.
Shifting of transformer from one site to another in case of emergency by disconnecting HT/LT cable and earthing connections of transformer of capacity 200 to 500 KVA , 11 KV/433 volts 3 phase floor mounted incl making all electrical connections at the place of installation complete all as specified and as directed. Notes :- (i) The rate for transport and lifting of transformer by crane is deemed to be included in the rate quoted. (ii) The rate is deemed to be inclusive for disconnection & making connnections of transformer as required.
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 Hz AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper bus bar size 50x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :- (i) MCCB 320 Amps, 4 Pole, 36 kA, Adjustable thermal and fixed magnetic setting - 01 No (Incoming). (ii) MCCB 160 Amps, 4 pole, 25 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing).
(iii) MCCB 100 Amps, 4 pole, 25 kA, Fixed thermal and fixed magnetic setting - 02 No (Outgoing). (iv) S&F multi function digital meter with LCD display incl PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO) (v) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (vi) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
Supply and installation of LT panel 'KIOSK type' cubical, weather, dust and vermin proof (out door type) CPRI approved factory made suitable for operation on 1100 volts 3 phase, 4wire, 50 HZ AC electric supply, externally powder coated & internally painted with two coats of synthetic enamel paint over one coat of red-oxide primer, made out of 3mm thick CRCA steel sheet as size having opening and locking arrangement both from front and back side with cable tray of size not less than 20cm including copper busbar size 25x06 mm, fixing on angle iron size of 50x50x6mm including connected accessories and necessary PCC work 1:3 :6 type C-2 blocks complete with following accessories :-
(i) MCCB 160 Amps, 4 Pole, 16 kA, Fixed thermal and fixed magnetic setting - 01 No (Incoming). (ii) MCCB 100 Amps, 4 pole, 10 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing). (iii) MCCB 63 Amps, 4 pole, 10 kA, Fixed thermal and fixed magnetic setting - 01 No (Outgoing). (iv) S&F multi function digital meter with LCD display including PT and CT having CTR 50/5 (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) - 01 No (Make : L&T 4410 series Cat Part No. WL441010OOOO) (v) Indicators with neon lamp with RYB shade,240 volts 50 c/s of suitable capacity resistance - 01 set. (vi) Internal wiring with suitable size PVC insulated single core copper cable for connecting instruments-01 lot
M/L for earthing complete with steel earth plate eletrode 60cm x 60cm x6mm thick buried directly in ground vertically (earth pit not less than 2.25 mtr below ground level) with top edge of plat not less than 1.5 mtr below ground level connected to GI earth strip 25x4mm by means of bolts. nuts,check nuts and washers etc including protection pipe 40 mm dia up to 7.5m length , provision the earth lead to earth connection in ther main distribution box with lugs and GI nuts,bolts, earthing shall be done all as per shown electrical plate No 5 of SSR part 1 Including neccessary excavation disintergrated hard rock filling earth of 15 mm thick and privision of earth pit provision of 20mm dia eith funel PCC earth chamber 100mm thick precast RCC cover with suitable precast RCC frame and earth test point and testing in presence of Engineer-in-Charge. Note : GI earth strip upto 7.5 RM is included in the unit rate quoted.
M&L for servicing of 11 KV Indoor Vaccum Circuit Breaker (VCB) of any make at NOFRA sub station which includes disconnecting, removing old grease, re-greasing of moving parts with recommended grease and checking of the entire breaker trolley mechanism,checking of the closing and tripping time in milli seconds using high precision time scope timer, measurements of contact resistance and insulation values, cleaning the complete VCB by opening front and back doors, tightening of cable connections, checking & repairing the current circuit panel wiring, relay etc and re-assembling & re-installing the VCB back to its original position including testing and commissioning after completion of work all as specified and as directed. NOTE : The cost for minor spares such as operating handles, screws,nuts,bolts, washers indicating lamps, lamp holders, HRC fuses,fuse carriers etc shall be included in the rate quoted for the item. Servicing shall be carried out as per manufacturer recommended checklist.
M&L for cross arm bracing support to clamps and back plate fabricated from structural steel section like angles channels flat etc including nuts bolts and washers welding bending cold or hot drilling holes for bolts if any shape and size and incl applying two coats of aluminium paint over one coat of red oxide primer including dismantling of old cross arms all as specified and as directed.
M&L for HT 11 KV Disc type insulator with hardware, single disc assembly, polymeric insulator, socket type, including taking down old unsv insulatorall as specified and as directed.
S&F for Pin type polymer insulator including one galvanised mild steel spindle two GI washers and one GI iron nut for 11 KV grade including dismantling the old U/S insulator all as specified and as directed.
Dismantling of ACSR condctor of any size from pole all as specified and as directed.
M&L for aluminium conductor steel wire reinforced (ACSR) fixed as over head line incl lighting through pole and on insulator with aluminium binding wire and including jumpers complete all as specified and as directed.
M&L for dismantling the old one and installation of new sign board mounted on MS flat Angle iron frame and PUC/Acrylic board with neon writing letters should be machine cut as required include flat iron clamps & angle iron support for grouting /fixing on walls complete including computer printing/inject printing of wards/diagram/emblems etc all as specified and as directed. Note :- The matter in each case depending on the installation will be as given and finalised by the Engineer-in-charge. The rate quoted is deemed to include the same.
S&F cable route indicator, made out of precast RCC, embossed with 'HT UG cable 11kV' grouted in and including excavation and PCC 1:2:4, type B-2, using 20mm graded stone aggregate for refilling complete all as specified and as directed.
Bharat Sales Corporation
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .