| 1 | L1₹7.9 CrAdmitted-Finance | ₹7.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹8.2 Cr+₹33.2 L (4.23%)Admitted-Finance | ₹8.2 Cr+₹33.2 L (4.23%) | L2 | Admitted-Finance |
| 3 | L3₹8.8 Cr+₹97.2 L (12.4%)Admitted-Finance | ₹8.8 Cr+₹97.2 L (12.4%) | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Gaikhonlung Panmei L3 | Nongthombam Motilal Singh L2 | PARKER CONSTRUCTIONS L1 |
|---|---|---|---|---|---|---|
| 1.00(SH:- Construction of 20 SM Barrack- G+I) | ||||||
| 2.00GROUND FLOOR | ||||||
| 3.00EARTH WORK | ||||||
| 4.00 | Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge.(a)All kinds of soil. | 102.14 | m3 | 281 ₹28,701.34 | 261 ₹26,658.54 | 250 ₹25,535 Lowest |
| 5.00 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m. | 34.05 | m3 | 235 ₹8,001.75 | 218 ₹7,422.9 | 209 ₹7,116.45 Lowest |
| 6.00 | Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km . | 72.37 | m3 | 1,383 ₹1,00,087.71 | 1,283 ₹92,850.71 | 1,231 ₹89,087.47 Lowest |
| 7.00CONCRETE WORKS | ||||||
| 8.00 | P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size). | 30.65 | m3 | 12,509 ₹3,83,400.85 | 11,604 ₹3,55,662.6 | 11,136 ₹3,41,318.4 Lowest |
| 9.00R.C.C WORKS | ||||||
| 10.00 | Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 45 cm bore dia and length 15.00 m from existing G.L i/c reinforcement complete as per drawing and technical specifications. | 48 | Each | 1,18,462 ₹56,86,176 | 1,09,891 ₹52,74,768 | 1,05,462 ₹50,62,176 Lowest |
Tender Value
₹6.4 Cr
EMD Value
₹12.7 L
Closing Date
19 Jun 2025, 1:00 pmClosed
Executive Engineer-I
MPHC Office Complex
Infrastructure Development of INA Head Quarter Moirang, Bishnupur District, Manipur
2025_MPHCL_2760_1
01/EE-I/MPHC/2025-26/BPR
Open Tender
Civil Works
Works
180 days
As per Tender Documents
As per Tender Documents
11 documents required · 11 mandatory
₹25,000
MD MPHC Ltd.
₹12.7 L
20 Jun 2025
5 Jun 2025
19 Jun 2025
6 Jun 2025
19 Jun 2025
9 Jun 2025
7 Jun 2025 - 18 Jun 2025
Amount
(SH:- Construction of 20 SM Barrack- G+I)
GROUND FLOOR
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge.(a)All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km .
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 45 cm bore dia and length 15.00 m from existing G.L i/c reinforcement complete as per drawing and technical specifications.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c)Lintels, beams, plinth beams, girders, bressumers and cantilevers,
(d)Shelves (Cast in situ)
(e)Edges of slabs and breaks in floors and walls.
(f) Stairs, (excluding landings) except spiral-staircases.
BRICK WORK
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructuee above plinthlevel up to floor V level in: (i) cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand).
WOOD WORKS
Providing wood work in frame sof doors,windows,clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length (hold fast lugs or dash fastener shall be paid for separately : (a) Local bestquality Teak wood .
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows including ISI marked M.S butthinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately,all complete as per direction of Engineer-in-charge.(a)Local best quality Teak wood.(i)35 mm thick shutters.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing ISI marked oxidised M.S.sliding door bolt swith screws etc. complete(i) 300 x 16 mm
Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete :(a) 250x10mm
Providing and fixing bright finished brass handles with screws etc.complete : (a) 125 mm
FLOORING
Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with grey cement slurry including rubbingand polishing complete with :(i)Makrana white second quality.
FININSHING
12 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand) finished with a floating coat of neat cement.
STEEL WORKS
Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats,square rorround bars etc.including priming coat with approved steel primer all complete.
ROOFING & CEILING
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-sections 35 x15 x1.5 mm size main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600x 1200 mm centre to centre including fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (i) New work (two or more coats) over and including priming coat with cement primer.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed of dry brick ballast 40mm nominal size wellrammed and consolidated and grouted with fine sand includingfinishing the top smooth.
Brick edging 7cm wide 11.4cm deep to plinth protection with Istclass common burnt clay F.P.S. (non modular) bricks includinggrouting with cement mortar 1:4 (1 cement: 4 fine sand).
FIRST FLOOR
R.C.C WORKS
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(b)Lintels, beams, plinth beams, girders, bressumers and cantilevers,
(c )Shelves (Cast in situ)
(d) Edges of slab and breaks in floors and walls (i) Under 20cm wide
BRICK WORK
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructuee above plinthlevel up to floor V level in: (i) cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand).
WOOD WORKS
Providing wood work in frames of doors,windows,clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length(hold fast lugs or dash fastener shall be paid for separately : (a) Local bestquality Teak wood .
Providing and fixing panelled or panelled and glazed shutter sfordoors,windows and clerestory windows including ISI marked M.S butthinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately,allcompleteas per direction of Engineer-in-charge.(a)Local best quality Teak wood.(i)35 mm thick shutters.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete(i) 300 x 16 mm.
Providing and fixing bright finished brasst ower bolts (barreltype) with necessary screws etc. complete :(a) 250x10mm.
Providing and fixing bright finished brass handles with screws etc.complete : (a) 125 mm.
FLOORING
Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with grey cement slurry including rubbing and polishing complete with :(i)Makrana white second quality.
FININSHING
12 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
STEEL WORKS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(i) Hot finished welded type tubes.
Providing and fixing M.S. round holding down with nuts and wahser plates completes.
Providing and fixing M.S.grills of required pattern in frames of windows etc.withM.S.flats,square or round bars etc.including priming coat with approved steel primer all complete.
ROOFING & CEILING
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-sections 35 x15 x1.5 mm size main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600x 1200 mm centre to centre including fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with(i) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (i) New work (two or more coats) over and including priming coat with cement primer.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood).
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
SEPTIC TANK - 15 USERS CAPACITY
Earth work in excavation by mechanical means (Hydraulic Excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, including getting out the excavated soil and disposal of surplus excavated soil as directed,within a lead of 50 m.(i) All kinds of soil.(a) Lift upto 1.5 m.
Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (a) C.C. 1:3:6 (1 cement :3 Local coarse sand :6 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 (1 cem :2 Local coarse sand:4 graded stone aggrt.20mm n/size).
Providing and laying in position specified grade of reinforced cement concrte excluding the cost of centering, shuttering,finishing and reinforcement- All work upto plinth level (a) 1:1.5:3 (1 cement : 1.5 Local coarse sand : 3 graded stone aggrt. 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Local coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete up to plinth level/Above Plinth level.(a) Thermo-Mechanically Treated bars.
Centering & shuttering including strutting , propping etc and removal of form for : (a) Foundation footings, bases of columns etc. and mass concrete.
(b) Suspended floor , roof , landing, balconies ans access platform with water proof ply 12mm thick .
(c ) Edges of slab and breaks in floors and walls (i) Under 20cm wide
Brick work with 1st class common burnt clay FPS ( non modular) bricks in foundation and plinth in cement mortar 1: 4 (1 Cem:4 Local coarse sand) .
15 mm cement plaster 1:3 (1 cement: 3 Local coarse sand) finished with afloating coat of neat cement on the roughside of single or half brick wall.
P/F C.I. Cover with frame (for manhole and chambers) (i) 600 mm x 450 mm (heavy duty) (38 Kg).
(C). WATER SUPPLY & SANITARY FITTING
Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580 x 440mm with integral type foot rests.
Providing and fixing 600x450 mm beveled edge mirror ofsuperior glass (of approved quality) complete with 6 mm thickhard board ground fixed to wooden cleats with C.P. brass screwsand washers complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P.brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever required: (a) White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap .
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : (A). Kitchen sink without drain board (i) 610x460 mm bowl depth 200 mm.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (a) External Works.
(i) 25 mm dia
(ii) 40 mm dia
(iii) 100 mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.(A) Concealed work, including cutting chases and making good the wall etc.
(i) 15 mm dia
Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 :(a) 15 mm nominal bore.
Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 (a) 15 mm nominal bore.
Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet : (i) 150mm diameter
Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms.
Providing and fixing PTMTtowel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.(a) 450 mm long towel rail with total length of 495 mm, 78 mm wideand effective height of 88 mm, weighing not less than 170 gms.
P/F 125 mm dia grating with waste hole.
Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (i) 25 mm dia.
Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.
(SH: Providing IEI in the 20 SM Barrack (G+1)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 5/16 amps switch
© 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W012 complete with connection etc as reqd.(Havell's)
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged,connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F bus bar chamber with 4 strips copper bus bar length 300mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
(a)10 amp MCB "C" Curve
(a)20 amp MCB "C" Curve
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH:- Fencing of VIP Parking and Newely Acquired Area)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, asdirected by the Engineer-in- Charge.(a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 35 cm bore dia and of length 8.0m from existing G.L i/c reinforcement complete as per drawing and technical specifications.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending, binding and placing in position complete
( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(a) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
BRICK WORKS
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
FININSHING
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand) finished with a floating coat of neat cement.
Supply & Installation of sand stone cladding 25mm thick with all accessories e.g.Dholpur stone slab 25 mm thick etc to fix the panels on the top of the structure,Panel system will be fixed on the top of supporting structure in such a way that the system will ensure clear and opaque walls .
Providing and fixing steel gate partly grills and partly M.S. sheet 3.16 mm thick with M.S. angle frame of 65 X 65 X 6 mm including handles, hold fasts, locking arrangment and applying a priming coat of red lead paint ( as per standard design).
Providing & fixing SHS 25X25X3mm grills of required pattern to frames vertically and horizontally with Arrow at required end of frames based on Architectural drawing .. i/c priming,painting etc. Complete as per direction of Engineer-in-Charge.
(SH: Providing External Compound Lighting)
S/F integral LED post lantern "S" type 16 watt complete with all accessories i/c connection etc. as reqd.
SITC 160 watt LED High bay with excellent heat sink along with IP66 protection perfect solution for outdoor applications i/c connections etc. as reqd. Havells JETAIRISFLS 160W LED 757 PW BLTG.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
Supplying & installation of carbon dioxide type fire extinguisher suitable for fires involving materials like oil, electric & delicate machineries) capacity: 4.5 kg (ISI marked).
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
(SH:- GAZEBO)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, asdirected by the Engineer-in- Charge.(a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 40 cm bore dia and length 8.0 m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
BRICK WORK
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
STEEL WORKS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(i) Hot finished welded type tubes.
FLOORING
Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with grey cement slurry including rubbingand polishing complete with :(i)Makrana white second quality.
ROOFING & CEILING
Providing & Fixing of Metal Singles with Cement Fiber Board 19mm thick including bitumen adshive etc as diected by Engineer In Charge
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-sections 35 x15 x1.5 mm size main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600x 1200 mm centre to centre including fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Supply & fixing of 50 mm thick panels of size 2400/2700/3000 mm length and 600 mm wide having Tongue & Groove joint system for walls, partitions and floor. The panels are made of two fibre reinforced cement sheets enclosing a light weight aerated concrete core composed of cement & binders. The fibre reinforced cement sheets are confirming to IS 13000-1990 or IS-14862-2000 Classification Type A(with upto amendment took place). These panels need to meet transverse load & modulus of rupture requirements as per ASTM-E-72:98 & IS 2380 Part4. The panels are laid on G.I floor channel of 1 mm thick and 14x50/75x25 mm and ceiling channel of size 38x50/75x38 mm. The rate should include hard ware, Labor, transport, lifting charges and wastages etc. as a complete item of work excluding finising, fitting etc and partions laid as per specification, drawing & as directed by engineer incharge.
Providing and fixing anodised aluminium grill of approved design/pattern,with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @200 mm centre to centre, including cutting the grill to proper openings size for fixing and operation of handles and fixing approved anodisied aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in charge.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (i) New work (two or more coats) over and including priming coat with cement primer.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed of dry brick ballast 40mm nominal size wellrammed and consolidated and grouted with fine sand includingfinishing the top smooth.
Brick edging 7cm wide 11.4cm deep to plinth protection with Istclass common burnt clay F.P.S. (non modular) bricks includinggrouting with cement mortar 1:4 (1 cement: 4 fine sand).
(SH: Providing IEI in the Gazebo 3 nos.)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
(SH:- Construction of Kitchen cum Dining Hall)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, as directed by the Engineer-in- Charge.(a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 45 cm bore dia and length 15.00 m from existing G.L i/c reinforcement complete as per drawing and technical specifications.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c)Lintels, beams, plinth beams, girders, bressumers and cantilevers,
(d)Shelves (Cast in situ)
(e)Edges of slabs and breaks in floors and walls.
BRICK WORK
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructuee above plinthlevel up to floor V level in: (i) cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand)
WOOD WORKS
Providing wood work in frames of doors,windows,clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length(hold fast lugs or dash fastener shall be paid for separately : (a) Local bestquality Teak wood .
Providing and fixing panelled or panelled and glazed shutter sfordoors,windows and clerestory windows including ISI marked M.S butthinges bright finished of required size with necessary screws,excluding panelling which will be paid for separately,allcompleteas per direction of Engineer-in-charge.(a)Local best quality Teak wood.(i)35 mm thick shutters.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing ISI marked oxidised M.S.sliding door bolts with screws etc. complete(i) 300 x 16 mm
Providing and fixing bright finished brass towe rbolts(barreltype)with necessary screws etc. complete :(a) 250x10mm
Providing and fixing bright finished brass handles with screws etc.complete : (a) 125 mm
FLOORING
Marble stone flooring with 18mm thick marble stone (sample ofmarble shall be approved by Engineer-in-charge) over 20 mm(average) thick base of cement mortar 1:4 (1 cement : 4 coarsesand) laid and jointed with grey cement slurry including rubbingand polishing complete with :(i)Makrana white second quality.
FININSHING
12 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand) finished with a floating coat of neat cement.
STEEL WORKS
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(i) Hot finished welded type tubes.
Providing and fixing M.S. round holding down with nuts and wahser plates completes
Providing and fixing M.S.grills of required pattern in frames of windows etc.withM.S.flats,square or round barsetc.including priming coat with approved steel primer all complete.
ROOFING & CEILING
Providing and fixing false ceiling with 12 mm thick plain/ semi perforated or with design ceiling tiles of BWP type phenol formaldehyde synthetic resin bonded pressed particle board conforming to IS:3087 finished with a coat of aluminium primer on both sides & edges and two coats of synthetic enamel paint of approved quality on exposed face fixed to a grid made out of anodised aluminium (with 15 micron anodic coating) T-sections 35 x15 x1.5 mm size main runners and cross runners 23.5x19x1.5 mm fixed to main runners placed 600 mm centre to centre both ways so as to form a grid of 600 mm square. The frame work shall be suspended from ceiling by level adjusting hangers of 6 mm dia M.S rod fixed to roof slab by means of ceiling cleats. The suspenders shall be placed 600x 1200 mm centre to centre including fixing to the frame with C.P brace screws and applying a priming coat of zinc chromate yellow primer (aluminium frame work shall be paid separately).
Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm)with EPDM seal,complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trussesand including cutting to size and shape wherever required with(i) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and fixing precoated galvanised steel sheet roofing accessories , Zinc coating 120gsm as per IS: 277 in 240mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws or with polymer coated J or L hooks, bolts and nuts and or G.I. seam bolts and nuts, G.I. plain and bitumen washers complete : (i) Ridges plain (500 - 600mm). (a) Precoated galvanised iron profile sheets 0.50 mm thick.
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade (i) New work (two or more coats) over and including priming coat with cement primer.
Finishing walls with textured exterior paint of required shade : (i) New work (Two or more coats applied @ 3.28 ltr/10 sqm) over and including base coat of water proofing cement paint applied @ 2.20kg/10 sqm.
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Applying priming coat :- (b) With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/steel works:
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture.
Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed of dry brick ballast 40mm nominal size wellrammed and consolidated and grouted with fine sand includingfinishing the top smooth.
Brick edging 7cm wide 11.4cm deep to plinth protection with Istclass common burnt clay F.P.S. (non modular) bricks includinggrouting with cement mortar 1:4 (1 cement: 4 fine sand).
(SH: Providing IEI in the Kitchen-cum-Dining Hall
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
(a) 5/6 amps switch
(b) 15/16 amps switch
© 3 pin 5/6 amps socket outlet
(d) 6 pin 15/16 amps socket outlet
SITC surface mounted LED downlighter with white powder coated Al.housing with intrgrated electronic driver 15 W 840 LHEAAGPIA2W012 complete with connection etc as reqd.(Havell's)
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
S/F fan hook i/c bolt & nuts.
S/F 48"sweep (1200mm) AC ceiling fan complete with down rod,canopy, 3 (three) blades with regulator etc.as reqd. (Make Bajaj/Usha/Crompton)
S/F stepped type electronic fan regulator on the existing modular plate sewitch box i/c connection but excluding modular plate etc.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power LED as light source Havell's JETACOMPECTOFL50W LED 757LTG complete with connection as rqd. (Havell's)
P/F 60 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+6 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH:- VIP Parking)
(Roadwork)
Providing laying and compacting Granular Base/Sub base with naturally occuring Sand Gravel Material free from organic ore other deleterious constituent spreading with Motor Grader and compacted by rolling with power roller of 8-10 capacity in layers not exceeding 150mm (spread thickness)
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering : All work upto plinth level (i) 1:3:6 ( 1 Cement: 3 Kanhaighat coarse sand : 6 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. (a) Mild steel and Medium\Tensile steel bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(SH:- Wall of Valour & Footpath)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, asdirected by the Engineer-in- Charge.(a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 35 cm bore dia and of length 8.0m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C.work including bending, binding and placing in position complete ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c)Lintels, beams, plinth beams, girders, bressumers and cantilevers,
FININSHING
Brick work with Ist class common burnt clay F.P.S.(non modular)bricks in superstructure above plinth level upto floor V level in all shapes and sizes in : in cement mortar 1:4 (1 Cem:4 C/Sand)
UV Printing on Tiles Size 2'by2'(4sq.ft) @Rs.160per sq.ft, 42 Nos.Making & Installation of 2D Stainless Steel 304 Grade with Granite Stone ''ITEFA KURBANI ITMAD" Size 4'by1' (4sq.ft) @Rs.2500 per sq.ftMaking & Installation of 2D Stainless Steel 304 Grade with Granite Stone ''''I SHALL ALWAYS....TO INDIA" MEITEI LANGUAGE" Size 4'by4' 16sq.ft)@Rs.2500 per sq.ft Making & Installation of Inauguratio (n Nameplate with UV Printing on Stainless Steel Plate Size 7'x2'(14sq.ft) @Rs.1450 per sq.ft Making & Installation of Sandwich "NETAJI SUBHAS CHANDRA BOSS" photo UV printing on 3mm Acrylic with ACP frame Size 4'x4'(16sq.ft) @Rs.2500 per sq.ft(a) Transportation Charge
FOOTPATH & GROUND DEVELOPMENT
EARTH WORK
Banking excavated earth in layers not exceeding 20 cm. in depth,breaking clods,watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads, flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m. (i) All kinds of soil
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - (a) 1:4:8 (1 cem :4 Coarse sand: 8 graded stone aggrt. 40mm nominal size).
Providing and laying 40 mm thick factory made cement concrete interlocking paver block (Rubber Moulded ) of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with coarse sand etc. all complete as per the direction of the engineer-in -charge.
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
15 mm cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the roughside of single or half brick wall.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces : (i) Two coats
Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with thickness of existing ground prepared with proper level and ramming with the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge.
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base of cement mortar 1 : 4 ( 1 cement: 4 coarse sand ) laid and pointing with cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer -in - Charge.(i) Polished Granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Holticulture and Local Grass.
(SH:- WASHROOM)-2(Two) Nos
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, asdirected by the Engineer-in- Charge.(a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
Supplying and filling in plinth with sandy soil under floors including,watering,ramming consolidating and dressing complete with a lead of 15 Km .
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:5:10 (1 cement :5 kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing Cast-in-situ reinforced cement concrete under reamed piles of 1:1.5:3 (1 cem:1.5 c/sand:3 gr.st.aggrt 20 mm n/size) of 40 cm bore dia and length 8.0 m from existing G.L i/c reinforcement complete as per drawing and technical specifications
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c)Lintels, beams, plinth beams, girders, bressumers and cantilevers,
(d)Shelves (Cast in situ)
(e)Edges of slabs and breaks in floors and walls.
BRICK WORK
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructuee above plinthlevel up to floor V level in: (i) cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand).
WOOD WORKS
Providing wood work in frames of doors,windows,clerestory windows and other frames,wrought framed and fixed in position with hold fast lugs or with dash fastener of required dia and length(hold fast lugs or dash fastener shall be paid for separately : (a) Local bestquality Teak wood .
Providing and fixing panelled or panelled and glazed shutters for doors,windows and clerestory windows including ISI marked M.S butthinges brigh tfinished of required size with necessary screws,excluding panelling which will be paid for separately,all completeas per direction of Engineer-in-charge.(a)Local best quality Teak wood.(i)35 mm thick shutters.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with10mm dia bolts,nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : 3 coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing IS Imarked oxidised M.S.sliding door bolts with screws etc. complete(i) 300 x 16 mm
Providingandfixingbrightfinishedbrasstowerbolts(barreltype)with necessary screws etc. complete :(a) 250x10mm
Providingandfixingbrightfinishedbrasshandleswithscrewsetc.complete : (a) 125 mm
P/F Stainless steel(Ashirvad) Mortice Lever door bolts 300X16 mm with screws & nuts complete.
P/F Stainless steel(Ashirvad) Mortice Cylindrical door bolts 300X16 mm with screws & nuts complete.
P/F Stainless steel(Ashirvad) Tower bolts with screws & nuts complete.(a) 250x10mm
P/F Stainless steel(Ashirvad) Handles with screws & nuts complete,(a) 175mm
Providing and fixing Stainless steel(Ashirvad). hooks and eyes.(i)150mm
FLOORING
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm ( average ) thick base
FININSHING
12 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster of mix : (i) 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand) finished with a floating coat of neat cement.
Providing and fixing at all height false ceiling including providing and fixing of frame work made of special sections, power pressed from M.S. sheet and galvanised with zinc coating of 120 gms/ sqm (both sided inclusive) as per IS : 277 and consisting of
Fully Perforated Gypsum Plaster Board of size 1200 x 2400 x 12.5 mm having approx. 15% perforated size and pattern as approved by the Engineer-in-charge and as per manufacter's specification, with all 4 sides tapered and backed by acoustical tissue with N
Providing and applying white cement based putty of average thickness 1mm,of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :(i) Water thinnable cement primer
Finishing walls with Deluxe Multi surface paint system for interiors and exteriors using Primer as permanufacturers specifications :(i) Two or more coats applied @ 1.25 ltr/10 sqm. over and including one coat of Special primer applied @0.75 ltr/10 sqm.
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :(i)Two coats
Applying priming coat :- (a) With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)
Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture
Making plinth protection 50mm thick of cement concrete 1:3:6 (1cement : 3 coarsesand : 6 graded stone aggregate 20 mm nominalsize) over 75mm bed of dry brick ballast 40mm nominal size wellrammed and consolidated and grouted with fine sand includingfinishing the top smooth.
Brick edging 7cm wide 11.4cm deep to plinth protection with Ist class common burnt clay F.P.S. (non modular) bricks includinggrouting with cement mortar 1:4 (1 cement: 4 fine sand).
Providing and fixing WATER STORAGE TANKS (Sintex) with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level. (a)1000 litres net capacity storage tanks
50 User Septic tank Vide drg, no. MPHC/A-C2/75
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : -
(a) 1:3:6(1 cem :3 Coarse sand: 6 graded stone aggrt. 40mm nominal size).
(b) 1:2:4 cem :2 Coarse sand:4 graded stone aggrt. 20mm nominal size).
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 coarse sand:3 Kanhaighat graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(a) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply)
(c)Lintels, beams, plinth beams, girders, bressumers and cantilevers,
(d ) Suspended floors, roofs, landings, balconies and access platform,
(c) Edges of slab and breaks in floors and walls (i) Under 20cm wide
Brick work with Ist class common burnt clay F.P.S. (non modular)bricks in foundation and plinth in: (i) (1 Cem: 4 C/Sand)
Half brick masonry with Ist class common burnt clay F.P.S. (non modular) bricks in superstructuee above plinthlevel up to floor V level in: (i) cement mortar 1:4 (1 cement : 4 Kanhaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand)finished with a floating coat of neat cement.
SANITARY ITEMS
Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend White vitreous china dual purpose WC pan with white solid plastic seat and l
Providing and Fixing wash basin with C.I. brackets, 15mm C.P bass pillarrs taps, 32mm C.P brass waste of standard patter, i/c painting of fittings and brackets,cutting and making good the walls whereever required a) white vitreous china flat back wash basin size 450x300mm with single 15 mm C.P brass pillar tap.
Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :(i) Range of four half stall urinals with 10 litre P.V.C. automatic flushing cistern each .
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600 X 20 mm SONA C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type).
Providing and fixing Jacquer two in one bib cock of superior quality.a) 15 mm diameter .
Providing and fixing Royale stop cock of superior quality . (a) 15 mm diameter.
Providing and fixing PVC( Supreme) soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. (a) 110 mm
Providing and fixing PVC ( Supreme) soil, waste, rain water and vent pipes including all requisite fittings, jointing of pipes & fittings with solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in charge. (a) 50 mm
Providing and fixing 100mm PVC( Supreme) plain bend of required degree.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. (i)50 mm nominal outer dia Pipes
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes
(SH: Providing IEI in the Toilet Block 3 W.C. - 2 nos. (Gents & Ladies)
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in surface/recessed pvc conduit with modular type switch, modular plate suitable size GI-box and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
P/L 4mm2 twin core pvc ins.(heavy duty) Cu. cond. armoured cable of 1.IKV grade in size not exceedng 25mm2 direct in ground i/c excavation, sand cushioning protective covering and refilling the trench etc.as reqd.
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan, making good the damaged, connection testing commissioning etc. as reqd.
S/F 305mm sweep exhaust fan complete with accessories i/c connection etc. as reqd.
P/F 30 amp MCSPN switch unit 240/250v with rewireable fuses i/c drilling holes on the board connection, earthing the body etc.as reqd.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Earthing with G.I.earth pipe 4.5mt.long and 40 mm dia. i/c accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.as reqd.
Extra for using salt and charcoal for pipe electrode as reqd.
P/F 4.06mm dia.copper wire on surface or in recess for loop earthing etc.as reqd.
(SH:- Construction of 20,000 K/litres capacity Ground Sump)
EARTH WORK
Earth work in excavation by mechanical means (Hydraulicexcavator)/ manual means over areas (exceeding 30cm in depth.1.5m in width as well as 10 sqm on plan) including getting out anddisposal of excavated earth, lead upto 50m and lift upto 1.5m, asdirected by the Engineer-in- Charge.(a)All kinds of soil
Filling available excavated earth (excluding rock) in trenches, plinth sides of foundation etc. in layers not exceeding 20cm in depth consolidating each deposited layer by ramming & watering lead upto 50m and lift upto 1.5m.
CONCRETE WORKS
P/L cement concrete in foundation and plinth excluding the cost of centering and shuttering : - 1:3:6 (1 cement :3 kanhaighat coarse sand :6 graded stone aggrt. 40mm nominal size).
R.C.C WORKS
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1.5:3 (1 cement :1.5 coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement :1.5 Kanhaighat coarse sand:3 graded stone aggregate 20 mm nominal size.)
Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete up to plinth level. ( a ) Thermo-Mechanically Treated bars.
FORMWORK
Providing form works i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for in-situ reinforced concrete to and plain concrete work in(using 12mm shuttering ply).(a) Foundation footings, bases of columns etc. and mass concrete.
(d)Shelves (Cast in situ)
(e)Edges of slabs and breaks in floors and walls.
(f) Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc
FININSHING
15 mm cement plaster 1:3(1 cement:3 kanhaighat coarse sand) finished with a floating coat of neat cement.
Nongthombam Motilal Singh (BID ID -8976)
Gaikhonlung Panmei (BID ID -8975)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.80 MB
Drawing.pdf
Additional Documents • 7.66 MB
Document.pdf
Tender Documents • 6.97 MB
BOQ_3017.xls
BOQ • 0.50 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .