Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.0 CrAccepted-AOC 107 1F TOLLYGUNGE ROAD KOLKATA 700026 | KOLKATA | KOLKATA | WEST BENGAL | 700026 | ₹2.0 Cr Quoted ₹2.1 Cr | L1 | Accepted-AOC Being lowest tender |
| 2 | L2₹2.3 Cr+₹19.8 L (9.22%)Rejected-Finance | ₹2.3 Cr+₹19.8 L (9.22%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹2.3 Cr+₹20.2 L (9.41%)Rejected-Finance 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹2.3 Cr+₹20.2 L (9.41%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹3.1 Cr+₹96.9 L (45.1%)Rejected-Finance | ₹3.1 Cr+₹96.9 L (45.1%) | L4 | Rejected-Finance Higher than lowest tender |
Tender Value
₹2.5 Cr
Closing Date
28 Feb 2022, 6:00 pmClosed
BRIG AS CHONKER CHIEF ENGINEER KOLKATA ZONE
HQ CHIEF ENGINEER KOLKATA ZONE, MILITARY ENGINEER SERVICES, BALLYGUNGE MAIDAN CAMP, GURUSADAY ROAD, KOLKATA-700019
ADDN ALTN AND SPECIAL REPAIR TO NURSING OFFRS MESS P 94 AT CH EC KOLKATA
2022_MES_503284_1
89046/E8
Open Tender
Civil Works
Item Rate
270 days
GE ALIPORE KOLKATA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹2,000
Yes
GE ALIPORE KOLKATA
Exempted
24 Mar 2022
22 Jan 2022
3 Mar 2022
22 Jan 2022
28 Feb 2022
14 Feb 2022
Amount
Taking down old damaged cement plaster of any description including racking out joints hacking for key, scrubbing down with water upto 04 storied of building complete all as specified and as directed.
All as per item No. 1.01 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Chipping of unsound /weak concrete materials (including taking down old cement plaster) from slabs, beams, columns, lintel, chajja, fin, facia etc. by any means as directed by Engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign materials, loose concrete/aggregate etc and disposal of all debris out of MOD land and complete all as specified and as directed. (upto 4 storey of building) for 25mm average thickness for slabs/Chajja/ beam.
All as per item No. 1.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
All as per item No. 1.03 here-in-before but 50mm average thickness for beams/ lintels (upto 4 storey of building) complete all as specified and as directed.
All as per item No. 1.05 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Alll as per item No. 1.03 here-in-before but 60mm average thickness for column (upto 4 storey of building) complete all as specified and as directed.
All as per item No. 1.07 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Add or deduct for every 10 mm thickness extra (upto 4 storey of building) complete all as specified and as directed.
Alll as per item No. 1.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm) clear air gap by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical as per manufacturer's instruction followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer's instruction to give it a totally rust free finished steel surface complete all as specified and directed. upto 12 mm dia bar (upto 4 storey of building)
All as per item No. 1.11 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm) clear air gap by manual methods (using wire brushing, chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturer's instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge above 12 mm dia bar (upto 4 storey of building)
All as per item No. 1.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material and labour for providing single coat epoxy bond adhesive on prepared non metallic surface (existing surface) and applying by brush as per manufactureres instruction/ specifications. The bonding agents shall have minimum compressive strength of 40N/mm² complete all as specified and as directed (upto 4 storiey of building).
All as per item No. 1.15 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimum specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed. (upto 4 storey of building)
All as per item No. 1.17 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for introducing new reinforcement bars upto 12mm dia bars Fe 550CRS for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed. (upto 4 storey of building)
All as per item No. 1.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M & L for introducing new reinforcement bars above 12mm Dia bar Fe 550 CRS for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc complete all as specified and directed. (upto 4 storey of building)
All as per item No. 1.21 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete as per drawing and direction of Engr-in-charge including power drilling holes of appropriate diameters to a minimum depth equal to 12 times the diameters of shear key bar/levelling gauge, cleaning the drilled holes of loose dust by blowing, insertion of epoxy from cartridge, placing the shear key bar in position and allowing it to stay undisturbed for 24 hours. Rate shall be include cost of labour, all materials, T&P for power drilling in concrete, epoxy cartridge, plastic nozzle etc, complete incl cleaning the drilled holes of loose dust by blowing air complete all as spd and dir by Engr-in-charge. 12 mm dia Fe 550 CRS, 300mm long @ MS shear key of bar. The projection length of shear key shall be more than 10 times its diameter plus half of the thickness of cover to concrete plus bend length. (upto 4 storey of building)
All as per item No. 1.23 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as specified and directed by Engn-in-charge. 60 mm average thickness of Column (upto 4 storey of building)
All as per item No. 1.25 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as specified and as directed. 50 mm average thickness of Beam (upto 4 storey of building)
All as per item No. 1.27 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc. The micro concrete shall have a minimum 1 day compressive strength of 10 MPa and 28 days strength of 50 MPa, minimum tensile strength 5N/mm2 @ 28 days, minimum flexural strength 5N/mm2 @ 28 days and complete all as specified and as directed. Add or deduct for every 10 mm thickness extra (upto 4 storey of building)
All as per item No. 1.29 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply, mixing and application two component structural grade polymer modified reinstatement mortar, where local spalling has taken place or shuttering is not possible . The mortar can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimum compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementitious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimum compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimum flexural strength 6.5N/mm2 complete all as specified and directed. upto 25 mm average thickness and (upto 4 storey of building). Note :- Cement and Sand in proportion 1:2 (graded coarse sand) with polymer admixed in proportions approved by Engr-in Charge.
All as per item No. 1.31 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for applying curing compound over concrete surfaces as per manufactures instruction complete all as specified and as directed. (upto 4 storey of building).
All as per item No. 1.33 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Removal of all the existing Pipes from the Toilet Shafts and the External Plasters to be Chipped off. After Proper washing with Clean water and removal of any Algae or Fungi or any other Vegetation allow the wall to be dried. Coat the Wall with modified styrene butadiene emulsion for use as a bonding aid and gauging liquid for cementitious systems. Followed by 1:4 Cement Plaster Mixed with water proofing chemical as per manufacturers instructions .Install the New Spun Pipes for waste water once the Wall plaster gets Cured complete in all respect as specified and directed. ( Removal of pipe, preparation of surface to be measured and paid separately ) .(upto 4 storey high building)
All as per item No. 1.35 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for hoisting, assembly and fixing of double layer steel scaffolding to external perimeter of building duly cross braced and properly aligned for the functional aspect and safety of the building including dismantling, shifting & removal from site complete all as specified and as directed. ( upto 4 storey high building) Note: - Elevational area of the scaffolding facing the building shall be measured for payment.
All as per item No. 1.37 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply & application cementitious grouting admixture with the cement slurry at a dosage 225 ml per bag cement and injecting with high pressure by grouting pump through non return PVC nozzles prefix with rapid setting cementitious plugging mortar to fill all possible pores and gaps left with in the old concrete mass. When the flow of grout stops or shows refusals or grout flows out from the adjacent nozzle, pumping to be stopped and the nozzle to be tied up and allowed to set for 24 hours. The PVC nozzles to be sealed off with quick setting cementitious plugging mortar. Grouting operation to be carried out through next nozzle till the entire area is covered. The grouting holes to be finished by removing the protruded portion of nozzles and finishing flush with the surface, complete as per manufacturer’s instruction as specified and as directed. ( upto 4 storey high building)
All as per item No. 1.39 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm (upto 04 storey of building).
all as per item No. 1.41 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for bore packing of all the Spouts to be done with grouting admixture mixes with Cement Concrete / Mortar @225 ml per bag of Cement complete as per manufactures inspection and as directed by Engr-in-Charge (upto 04 storey high building)
All as per item No. 1.43 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F shear connector of 8mm dia Fe 550 CRS & requisite length on the surface to be repaired for the bonding between old and new concrete as per the locations instructed by the Engr-in-Charge. The shear connectors shall be of L shape and welded with existing reinforcement at least 100mm in length @ 200mm c/c both horizontally and vertically followed by coat of epoxy Zinc primer as per the specification mentioned in complete all as specified and as directed. (upto 04 Storey of Building).
All as per item No. 1.45 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Demolition of RCC of any description and in any position not otherwise specifically provided for complete all as specified and directed . (upto 04 storey of building).
All as per item No. 1.47 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork to sides of column, pillars, posts, stanchions for rough finished surface complete all as specified and as directed. (upto 04 storey of building).
All per item No. 1.49 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface complete all as specified and as directed. (upto 04 storey of building)
All as per item No. 1.51 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing horizontal or sloping and similar work exe 5 cm but not exe 10 cm thick complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.53 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork to chullah hoods, chajjas, troughs, parapets and similar items including edges for rough finished surface complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.55 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for RCC for chullah hoods, stairways(except spiral staircase) including steps (Square or spandril), string spices, carriages etc complete any section , straight or winding but excluding landings, RCC Water tank upto 1500 Ltrs, Type B0 1: 2:4 ( using 12.5 mm graded store aggregate) complete all as specified and directed. (upto 04 storey of building).
All as per item No. 1.57 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F TMT bars 10mm dia Fe 550 CRS and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.59 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F TMT bars 8 mm dia Fe 550 CRS cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips. (upto 04 storey of building).
All as per item No. 1.61 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F TMT bars 8 mm dia Fe 550 CRS and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips.complete all as specified and as directed. (upto 04 storey of building)
All as per item No. 1.63 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. (upto 04 storey of building).
M & L for Cement concrete in saucer drains Type B1 1:2:4 (20 mm graded aggregate) slope maintained as per site requirement complete all as specified and directed.
Demolition of Brickwork quoins, arches, pillars etc but excluding ashlar facings, dressed all store work and precast concrete articles built in cement mortar complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.67 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for brick work with sub class 'B' bricks built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius and all as directed. (upto 04 storey of building).
All as per item No. 1.69 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.71 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for Rendering 10mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement to match the existing surface complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.73 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for Rendering 20mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound applied as per manufacturers instructions shall be laid over 10mm thick plastered surface) with CM (1:4) on of brick work or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and as directed. (upto 04 storey of building). (Note: WPC shall be measured and paid separately).
All as per item No. 1.75 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply only water proofing compound in all respect complete all as specified and directed (upto 04 storey of building).
All as per item No. 1.77 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for Rendering 5mm thick with CM (1:3) on or concrete surfaces and finished the surface even and smooth as in ceiling to match the existing surface complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.79 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material & Labour for applying Finishing walls in new surfaces with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over and including 3mm thick wall care putty complete in all respect as specified and directed by the Engr-in-Charge. The Entire Building to be Coated with this product after all Repairing work complete in all respect as specified. (upto 04 storey of building) complete all as specified and as directed. Note:- Performance guarantee alongwith security deposit amount as specified in perticulars specification for Five (05) years shall be submitted by the contractor after physical completion of work.
All as per item No. 1.81 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material & Labour for applying Finishing walls in old surfaces with Acrylic Smooth exterior paint of required shade (Two coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over and including 3mm thick wall care putty with complete removal of existing paint complete all as directed by the Engr-in-Charge.. The Entire Building to be Coated with this product after all Repairing work complete in all respect complete all as specified and as directed. (upto 04 storey of building). Note:- Performance guarantee alongwith security deposit amount as specified in perticulars specification for Five (05) years shall be submitted by the contractor after physical completion of work.
All as per item No. 1.83 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L preparation of new plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.85 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L preparation of old surface and applying one coats of white wash on ceiling to match with the new one complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.87 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L preparation of new plastered surface and applying two coats of acrylic washable distemper over a coat of primer over 3 mm thick (minimum) cement base wall putty and complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.89 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coats of oil emulsion distemper over a coat of primer over 3 mm thick (minimum) cement base wall putty to match with the new surface on wall and complete all as specified and as directed. (upto 04 storey of building) .
All as per item No. 1.91 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L Preparing new plastered surfaces of wall and applying 3 coats of white wash on walls surface complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.93 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L preparation of old surface and applying one coat of white wash on wall surface complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.95 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Dismantling of floor hearth including cement mortar and backing coat, and rubbish off the premises (out of MOD land), complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 1.97 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Dismantling wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
All as per item No. 1.99 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for double charged vitrified ceramic tiles 10 mm thick (square /rectangular) polished light shade, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 Sqm (size of tile 800mm x 800mm x 10mm) in floor etc. set and jointed in neat cement slurry and pointed white or coloured cement to match the shade of the tiles complete all as specified and directed. (upto 04 storey of building). Note:- Backing coat/ screed bed shall be measured paid separately under respective items of BOQ.
All as per item No. 2.01 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for double charged vitrified ceramic tiles 10 mm thick (square /rectangular) polished light shade, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm (size of tile 800mm x 800mm x 10mm) as in Skirting/ Dado etc. set and jointed in neat cement slurry and pointed white or coloured cement to match the shade of the tiles complete all as specified and directed. (upto 04 storey of building). Note:- Backing coat/ screed bed shall be measured paid separately under respective items of BOQ.
All as per item No 2.03 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
All as per item No 2.01 here-in-before but size of each tile exceeding 0.42Sqm but not exceeding 1.00Sqm (1200mm x 600mm x 10mm) complete all as specified and as directed.
All as per item No 2.03 here-in-before but size of each tile exceeding 0.42Sqm but not exceeding 1.00Sqm (1200mm x 600mm x 10mm) complete all as specified and as directed.
M&L Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.07 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L backing coat/screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:4) as in dado/skirting complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L Non-skid coloured ceramic floor tiles not less than 08 mm thick ( Square / rectangular) area of each tile exc. 0.11 sqm but n exc 0.18 sqm in floor set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. (Note:- Screed bed shall be measured and paid separately under respective items of BOQ) (upto 04 storey of building).
All as per item No. 2.11 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L Glazed ceramic coloured wall tiles of size 450x350 x 7mm/ 450mmx 300mm x7mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed. (Note:- Rendering/backing coat shall be measured and paid separately under respective items of BOQ) (upto 04 storey of building)
All as per item No. 2.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M& L for 18 to 20 mm thick Granite (of any type and colour) machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including polishing complete all as sepacified and directed. (upto 04 storey high of bldg). Note : Size of Granite slab, colour and texture shall be approved by GE.
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed. (upto 04 storey of building). Note : Size of Granite shall be approved by GE.
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed. (upto 04 storey of building)
M&L for polishing of existing Terrazzo old tiles 20cm x 20cm x 20mm thick, with size of chips upto 12mm for treating the surface with beeswax polish complete all as specified and as directed by Engr-in-Charge. (upto 04 storey High of building)
All as per item No. 2.18 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F of Terrazzo tiles 20cm x 20cm x 20mm thick, with size of chips upto 12mm jointed and pointed in neat cement slurry in floors, and cut and polished complete all sepecified and directed by Engr-in-Charge. (upto 04 storey High of building)
All as per item No. 2.20 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking up or down 15mm steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and as directed.. (upto 04 storey of building).
All as per item No. 2.22 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring, etc and making good, cutting not exc 10 cm girth in Brick Walls complete all as specified and as directed by Engr-in-Charge. (upto 04 storey High of building)
All as per item No. 2.24 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F CPVC pipes 20 mm outer diameter of SDR 11 including plain CPVC SDR 11 fittings as in walls, ceiling, floor, etc. complete all as specified and directed.(upto 04 storey High of building)
All as per item No. 2.26 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking up or down 20mm steel tubing and connections, including cleaning for refixing or removal from site complete all as specified and as directed.. (upto 04 storey of building) .
All as per item No. 2.28 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F CPVC pipes 25 mm outer diameter of SDR 11 including plain CPVC SDR 11 fittings as in walls, ceiling, floor. etc complete all as specified and directed.(upto 4 storey of building)
All as per item No. 2.30 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repair 25mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.32 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repairs 15mm bore Brass CP bib cock fancy type with crutch or butterfly handle complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.34 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repair 15mm bore Brass CP stop cock fancy type, with crutch or butterfly handle complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.36 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F PVC connection 15 mm size pipe with PTMT nut of Length 600mm complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.38 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repair brass CP shower roses with or without swivel joints, with shower arm, 125mm size, including fixing to steel pipes or union complete all as specified and as directed. (upto 04 storey of building).
All as per item No. 2.40 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L 50 mm thick precast cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) slab flooring, bedded, and jointed in cement mortar 1:6 and pointed in cement mortar 1:3, complete all as specified and as directed. (upto 04 storey High of building)
S&F Chromium plated Soap dish, fixed to plugs with chromium plated brass screws complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 2.43 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repairs Vitreous China wash basin (white), flat back, size 550 x 400 mm, excluding taps, waste, chain and plug and porcelain stopper but including cutting for and pinning in ends of and brackets, waste pipe & CP Brass waste coupling of 32mm dia complete all as specified and as directed. (upto 04 storey of building). Note : Rate quoted under this item shall be deemed included fixing of plug and chain and connecting up to supply pipes, wastes or traps etc.
All as per item No. 2.45 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
All as per item No. 2.47 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repair 15 mm bore Fancy type Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. (upto 04 storey High of building).
S&F in repair 15 mm bore Pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered ‘Hot' or ‘Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed. (upto 04 storey High of building).
All as per item No. 2.51 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 15mm Brass CP Wall mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. (upto 04 storey High of building).
All as per item No. 2.53 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 32mm dia flexible PVC waste pipe for basin etc complete all as specified and directed. (upto 04 storey High of building).
All as per item No. 2.55 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S & F in repair Vitreous China wash down water closet pan (pedestal pattern) including sheat cover, white (excluding fixing bolts, flushing cistern and flush pipe) complete all as specified and directed (upto 04 storey High of building).
All as per item No. 2.57 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supplying and fixing in repairs 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipe complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 2.59 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repair Stainless steel kitchen rack / plate rack of size 31"x36"x10", made of stainless steel sheet not exc 1 mm thick etc complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building)
S&F in repair PVC (SWR) floor trap, plain with grating including jointing with solvent cement of 100mm dia complete all as specified and directed (upto 04 storey High of building).
All as per item No. 2.62 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F PTMT in repair grating of 100mm dia, fixed with cement mortar (1:3). complete all as specified and directed. (upto 04 storey High of building).
All as per item No. 2.64 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F PTMT tubular towel rail 450mm long, with and including CP brass screws and wooden/plastic cleats, weight not less than 170 gms complete, fixed in wall complete all as specified and directed. (upto 04 storey High of building)
All as per item No. 2.66 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms) complete all as specified and directed (upto 04 storey High of building).
All as per item No. 2.68 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F Toilet paper holder of Chromium Plated fixed to walls with chromium plated (CP) brass screws complete all as specified and directed. (upto 04 storey High of building)
All as per item No. 2.70 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in repair Chrome finish Health faucet with 1 m SS flexible tube, wall hooks and all necessary fittings complete all as specified and directed. (upto 04 storey High of building).
All as per item No. 2.72 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking down chowkat with PVC shutter (without taking off shutters from the frame) n. exc 1.5 sqm each and removing to store complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 2.74 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking down chowkat with shutter (without taking off shutters from the frame) area exc 1.5 sqm but n.exc 4 sqm each remove to store etc. complete all as specified and directed. (upto 04 storey High of building)
All as per item No. 2.76 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F for factory made solid PVC door frame of size 50mm X 47mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube (size19 sqmm MS tube of 19 gauge),fixing in opening as per specification & drawing complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 2.78 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; panelling of plain colour PVC sheet to be fitted in the MS frame (size 15 sqmm MS tube of 19 gauge) welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, supply and fixing in the frame complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building)
All as per item No. 2.80 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 125 mm long Aluminium handles, cast type, anodised complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building)
All as per item No. 2.82 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 100 mm long Butt hinges, stainless steel hinges fixed to shutter etc complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 2.84 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F Aluminium Hat pegs, solid body, 125mm to 175 mm complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 2.86 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 100 mm long Aluminium anodised, barrel tower bolts of extruded section all as specified and as directed.(upto 04 storey of building).
All as per item No. 2.88 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S & F Fixed type partly glazed, partly gauged. Solid PVC ventilator including 3mm thick frosted glass pane, 0.36mm dia & 1.4mm aperture stainless steel wire net, glazing clip, fastener etc complete all as specified and directed. complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 2.90 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply and fixing 3.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 2.92 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply & fixing Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples Complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 2.94 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supplying and fixing Mild Steel framed work such as grills, gratings, etc. with ends of bars soldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, railings and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed and design/shape approved by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 2.96 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material & labour preparation of new steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 2.98 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material & labour preparation of old steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 3.00 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for cement concrete ( 1:2:4) type B1 (using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 3.02 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Dismantling cast iron or reinforced concrete drain pipes of 100mm bore, jointed in cement mortar complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 3.04 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S/F PVC (SWR) vent cowl 110 mm dia complete all as specified and as directed.
S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints fixed to walls with clamps spacing 1000 mm C/C , complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 3.08 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 110mm bore PVC(SWR) bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 3.09 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S & F 110mm PVC (SWR) WC connector bent type complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 3.11 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S & F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 3.13 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material & labour preparation of old painted steel surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge (upto 04 storey of building).
All as per item No. 3.15 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Material & labour preparation of old painted wooden surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge (upto 04 storey of building).
All as per item No. 3.17 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F CPVC pipe fiitings of Brass Elbow/Socket of 20 mm outer dia complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 3.19 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F CPVC pipe fiitings of Brass Tee of 20 mm outer dia complete all as specified and directed. (upto 04 storey High of building)
All as per item No. 3.21 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F CPVC pipe fiitings of Female Brass Threaded Adaptor ( FTA / FBTA) of 20 mm outer dia . complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 3.23 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply and fixing in repairs 3.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 3.25 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Supply & fixing in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples complete all as specified and as directed. (upto 04 storey High of building).
All as per item No. 3.27 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 2nd Class hard wood Plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chanfered, put together with glue pinned at joints complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 3.29 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 35 mm thick 2nd class hard wood rail and style factory made plain framed, panelled shutter (two panel) with lock rail and panel of 9mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both faces complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 3.31 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 35mm thick 2nd class hard wood gauged & skeleton shutter factory made , open rebated & prepared to receive gauged, (without sash bar) edge of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauged etc, all as specified and directed. (upto 04 storey of building).
All as per item No. 3.33 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M & L for 18-20mm thick Granite (of any type) tiles machine cut, in skirting/ dado laid over cement screed and jointed with grey cement slurry, and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete complete all as specified and as directed. Note : Size of Granite slab, colour and texture shall be approved by GE
S&F 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary labours, articles n exc 200 cm each. (upto 04 storey High of building).
All as per item No. 3.36 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 3.38 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast al alloy all as specified and as directed. (upto 04 storey of building).
All as per item No. 3.40 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete all as specified and as bidirected by Engineer-in-Charge. (upto 04 storey of building).
All as per item No. 3.42 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L for 25x4mm size mild steel flat iron as in hold fast conforming to Fe-290 Gide E-165 complete all as specified and as directed by Engineer-in-charge. (upto 04 storey of building).
All as per item No. 3.44 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L PCC 1:2:4 Type B0 (using 12.5mm graded crushed stone aggregate) for fixing hold fasts, angle etc. complete all as specified and as directed. (upto 04 storey High of building)
All as per item No. 3.45 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S & F second class hard wood beads, straight (n exe 3 sq cm) for glazed or gauzed joinery, renewed, including mitres etc complete all as specified and as directed by Engineer-in-charge (upto 04 storey High of building).
All as per item No. 3.48 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking down door shutter exe 1 Sqm and n exe 2 Sqm each after resecuring or easing and adjusting including refixing in same opening (upto 04 storey High of building).
All as per item No. 3.50 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F in replacement Curtain rails with Decorative typre drappery Rod along with all fittings including barackets and knobs of 25 mm dia complete all as specfied and as directed. (upto 04 storey High of building).
All as per item No. 3.52 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M & L for Cub-boards shutters made with Particle board 18/19 mm thckness , medium density, flat pressed, single layer type or three layer type with BWR type adhesive, fixed with screws to timber nframe work fixed with screws to timber frame-work complete all as specified and as directed (upto 04 storey High of building)
All as per item No. 3.54 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M & L 6 mm thick teak wood lipping for Non asbestos fibre cement board for external complete all as specified and as directed (upto 04 storey High of building) .
All as per item No. 3.56 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S & F Aluminium Anodised Hasp and Staple, including bolt to hing plate and fixed with screws 100 mm size at any storey of building complete all as specified and as directed.
All as per item No. 3.58 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Use and waste of steel formwork flat fair finished surfaces to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 3.60 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking down steel window/ventilator with guard bar of any description and in any position not exceeding 1.5 Sqm each complete all as specified and directed (upto 04 storey High of building).
All as per item No. 3.62 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
Taking down of rolling shutter with frame area exc 6.0 Sqm but n.exc 10.0 sqm each remove to store etc complete all as specified and as directed.
Supply and fixing 1.00mm thick of laths steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete, push pull or manual type complete all as specified and as directed. (upto 04 storey High of building)
M & L for Crumple Joint with Aluminium Joints and Preformed Board 100 mm depth with chemicals all as per IS Code complete all as specified and as directed.
Stripping of old tar felt incl layer of plastic or mortar of any type of roof treatment carefully from roof surfaces (without damaging roof ) and including roughening of surface of old concrete roofing by picking, sweeping, cleaning and washing down with water to remove dust complete all as specified and as directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) finished with even and smooth without using extra cement for padding concrete with a slope of 1:40 complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar 1:4 mixed with Water Proofing Compound as per manufacture's instructions and top surface of rendering finished even and smooth to recieve water proofing treatment complete all as specifid and as directed. Note : Water Proofing Compound shall be measured and paid separately.
M&L cutting out cracks to "V" section in existing roofs of terracing cleaning out, wetting, grouting, with cement sand slurry 1:3 complete all as specified and as directed
M&L for providing PCC 1:2:4 type B1 (using 20mm graded stone aggregate) as in filling in depression on roof slab complete all as specified and as directed
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning width bleaching pouder as required, etc. and hoisting if required reconnecting and re-fixing in position,Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, etc exc 1000 ltr but not exc 2000 ltr complete all as specified and as directed (5 to 8 storey High of building).
Dismantling water tanks 1000 ltr capacity and removing to store 5 to 8 storey high of bldg complete all as specified and as directed
Supply and fixing 1000 Litre capacity rotational moulded polyethylene water storage tanks (multilayer.cylindrical vertical with closed top) with and including 25 mm dia PVC float valve .hoisted and fixed in position including taking down old one and deposited to store yard complete all as specified and as directed (5 to 8 storey High of building).
M&L for covering/filleting of sectional area exc. 25 sqcm but not exc. 50 sqcm in any position and to any shape in PCC 1:2:4 mix, type B1 (using 20 mm graded stone aggregate) incl all mitres, stops etc complete all as specified and as directed.
M&L APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove fabric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as per manufactures instruction and as directed by Engr-in-Charge (upto 4 storey high of building)
All as per item No. 3.76 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
M&L Rolled Mild Steel Fe- 290 (Gde E- 165)Framed work (in Mumty Door) as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and as directed.
M&L 0.71mm thick plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and as directed.
M&L Brickwork with sub class ‘B’ bricks in one brick thick honey comb walling, built in 1:4 cement mortar complete all as specified and as directed.
M&L Providing and injecting chemical emulsion for Post Constructional Antitermite Treatment along external wall where the apron is not provided using chemical emulsion at the rate of 7.5 litres per sq.m of the vertical surface of the sub-structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and as directed.
Removing building materials etc. (other than spoil) to a distance of 100m or under, beyond the lead included in the rates, including loading, unloading and stacking at the destination etc complete all as specified and as directed. (upto 04 storey High of building)
Removing building materials etc. (other than spoil ) to a distance of 1 Km of the lead included in the rates, including loading, unloading and stacking at the destination etc complete all as specified and as directed. (upto 04 storey High of building)
Removing building materials etc. (other than spoil ) to a distance of 5 km beyond the lead included in the rates, including loading, unloading and stacking at the destination etc complete all as specified and as directed. (upto 04 storey High of building).
Cutting of vegetation/plant/bush from wall, roof of Buildings up to extended root complete incl applying acid for stop further growth from any location of bldg up to 150 mm girth and making good disturbed surface witrh CM (1:4) or cement concrete type C -1 (1:3:6) using 20 mm graded aggregate incl necessary scaffolding complete all as specified and as directed. (upto 8 stroey Hight of building)
M&L PCC(1;2:4) type B1 using 20 mm graded agg as in Coping etc complete all as specified and as directed.
Extra for forming fair finished drain or channel including form, mould, mitred/stoped ends for 30cm inner girth complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30cm complete all as specified and as directed.
Surface dressing not exceeding 15 cm deep in soft/ loose soil complete all as specified and as directed.
M &L Cement concrete in foundations, filling and mass concrete Type D 2 (1:4:8) (40 mm graded stone aggregate) etc complete all as specified and as directed.
M & L 75mm thick Cement concrete type B-1, 1:2:4 (20mm graded stone aggregate) etc complete all as specified and as directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed.
M & L Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment etc complete all as specified and as directed.
M&L for Johnson endura checkered terracotta tiles of 400 X 400 X 10 mm thick set and jointed in neat cement slurry and pointed in white or colored cement to match complete all as specified and as directed.
M&L Non-skid coloured ceramic tiles 7 to 8 mm thick (square / rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed (upto 04 storey High of building). Note :- Screed bed shall be measured and paid separately under respective items of Sch 'A'.
All as per item No. 3.95 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F Aluminum Door with powder coated STANDARD Aluminum section of medium size and weight not less than 1.50 Kg/RM and conforming to catalogue of Jindal or equivalant. The door shall be of side hung type fixed and bottom with standard door spring, pintals etc. The bottom panel of the door shall be fitted with 12 mm thick pre laminated particle board decorated on both sides of approved color and 5 mm thick tinted glass in top panel complete incl all necessary fittings such as 02 Nos Handles of approved size and shape, 02 Nos Aluminum anodised tower bolts 200 mm long, 03 Nos of butt hinges and 01 No Mortice lock per shutter. The frame shall be with one or more rebates incl jointing cleats, glazing clips, standard rubber beading complete all as specified and as directed.
S&F for Powder coated aluminium sliding windows for (three tier) withwith shutter styles 40mm X 20 mm sheet thickness 1.5 mm Two shutter glass and one shutter of wiremess consisting of Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 100 mm X 44 mm X 1.5 mm thick section with or without rebate 5 mm thick tinted glass fixed with aluminum beads locking arrangements with each shutter incl aluminum grill complete all as specified and as directed (upto 04 storey High of building).
All as per item No. 3.98 here-in-before but from 5 storied to 8 storied of building complete all as specified and as directed.
S&F 4 mm thick E-board classic designer 595mm X 595 mm fixed as in false ceiling over powder coated aluminium grid suspended with GI hooks 6mm dia and clamp to the following section with all necessaery electrical fittings with light including taking down old unserviceable one complete all as specified and as directed. a) 25 X 25 X 1.5 mm (min thick) aluminium angle. b) 25 X 25 X 1.5 mm (min thick) aluminium cross Tee. c ) 25 X 25 X 1.5 mm (min thick) aluminium main Tee (upto 04 storey High of building).
S & F plywood for modular kitchen, grade BWR, type BB, fixed with Screws to timber frame work 12 mm thick including all necessary fitting complete all as specified and as directed.
S & F decorative laminate 0.9 mm thick type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufactures instruction complete all as specified and as directed.
S & F Brass locks with two lever, drawe, grade 1, size 50 mm including all necessary fitting complete all as specified and as directed.
S & F Brass drawers pulls, 3 screw plate with fixed dished pull 80 mm to 100 mm long including all necessary fittings complete all as specified and as directed.
S & F Ball catches with 8 mm dia steel ball and brass body and striking plate including letting in and fixed complete all as specified and as directed.
S & F 75 mm Butt hinges stainless steel and fixed including all necessary fittings complete all as specified and as directed.
S & F Brass handles 75 mm length, cast type polished bright including all necessary fittings complete all as specified and as directed.
M & L scond class hardwood plain fillets, square, retangular or triangular in section, clean sawn, secured with nails or brads not exc 3 sqm complete all as specified and as directed.
S & F SS cutlery Basket with Dimension (582 X 582 X 100 mm) including all necessary fitng, complete all as specified and as directed.
S & F SS Kitchen Thali Basket with Dimension (582 X 582 X 100 mm) including all necessary fittings complete all as specified and as directed.
S & F SS Cup and Saucer Modular Kitchen Basket with Dimension (582 X 582 X 150 mm) including all necessary fittings complete all as specified and as directed.
S & F Rectangular SS Plan Modular Kitchen Jali Basket With Dimension (582 X 582 X 150 mm) including all necessary fittings complete all as specified and as directed.
S & F Rectangular SS Plain 6mm 304 Grade (Full sheet) Modular Kitchen Basket for vegetable with Dimension ( 582 X 582 X 200 mm) including all necessary fittings complete all as specified and as directed.
S & F Left side SS Modular Kitchen Magic Corner / "S" Corner with Dimension of (600 X 400 X 250 mm) including all necessary fittings complete all as specified and as directed.
S & F Right side SS Modular Kitchen Magic Corner / "S" Corner with Dimension of (600 X 400 X 250 mm) including all necessary fittings complete all as specified and as directed.
S & F Zinc Coated SS steel ball type 24 " telescopic channel 1" width including all necessary fittings complete all as specified and as directed.
S & F SS Modular Kitchen wire Bin Holder Dimension (300 mm dia) with bin including all necessary fittings complete all as specified and as directed.
S & F SS Modular Kitchen Bottle Holder in two track Dimension (282 X 100 X 150 mm) including all necessary fittings complete all as specified and as directed.
S & F dual Motor 180+180 Watt or higher motor (2200 Cum/hr or more suction capacity) ktichen chimney including cutting holes and exhaust pipe and alll installation kit with incl all necessary fittings complete all specified and as directored.
Taking down copper/aluminium point wiring for one light/fan/socket/power point or buzzer controlled by one switch complete including fittings/fixtures such as switches,ceiling rose, holder, socket, light, fittings etc & making good disturbed surfaces of walls, ceilings etc all as specified and directed by Engr-in-Charge
Taking down carefully sub main wiring of size upto 10 Sqmm including making good disturbed surfaces of walls, ceilings etc all as specified and as directed.
Material and labour for point wiring concealed type in PVC conduit for one light/fan point controlled by one way switch,with 1.5 sqmm PVC insulated copper cable multistranded conductor 1100 volts grade (FRLS) (Red colour cable used for live connection, Black colour cable used for neutral connection and green cable used for earthing connection,Separate cable for earthing and neutral to be used for each individual circuit from the distribution board/Switch board) controlled by one way switch drawn through and including appropriate size of PVC casing capping/conduit with all accessoriese for surface/concealed wiring including 1.5 sqmm PVC insulatedun shealthed copper cable multistrand conductor 1100 Volts grade (FRLS) for continuity earth wire connected to each point and sunk cast pressed steel terminal box made out of MS sheet 1.2 mm thick for mounting of fittings like switch, socket and fan regulator with 3mm thick laminated/bakalite sheet cover all complete as specified and as directed.
All as per item No 4.22 here-in-before but for 3 Pin socket outlet 5 Amps same board with other switches with cable 1.5 Sq mm size all complete as specified and as directed.
All as per item No 4.22 here-in-before but for 3 pin 5 Amps socket outlet on independent board with 1.5 Sqmm all complete as specified and as directed..
All as per item No 4.22 here-in-before but one 3 pin socket outlet independent but below the switch board of light points in the same vertical plane, with cables, 1.5 Sqmm size all complete as specified and as directed.
All as per item No 4.22 here-in-before but for 5 pin 15 Amps switch socket combination on independent board with 2.5 Sqmm cable complete all as specified and as directed.
All as per item No 4.22 here-in-before but for one buzer point controlled by one bell switch complete all as specified and as directed.
All as per item No 4.22 here-in-before but for one light point controlled by two 2 way swithces with cables 1.5 Sqmm size complete all as specified and as directed.
All as per item No 4.22 here-in-before but for power socket pt with 4 Sqmm cable and 2.5 Sqmm earth continuity wire complete all as specified and as directed.
M & L for socket outlet 2 in 1, 3 pin, 5A, flush type, 240 Volts, flush type complete all as specified and as directed.
M & L for switch socket combination 2 in 1, 5 Amps, 240 V Flush type, uneversal complete all as specified and as directed.
M & L for switch socket combination 5 pin 5/15 Amps,Shuttered flush type, 240 Volts, universal complete all as specified and as directed.
Supplied & fixed single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 240 Volt 20 Amps complete all as specified and as directed.
S & F Buzzer, Ding Dong AC 230 Volt single pole complete all as specified and as directed.
M&L for bell push 5 Amp complete all as specified and as directed.
S & F switch piano type 5 Amp single pole one way complete all as specified and as directed.
S & F switch piano type15 Amp single pole one way complete all as specified and as directed.
S & F Switch piano type 5 Amp single pole two way complete all as specified and as directed.
S & F for ceiling rose surface backelite 65 x 50mm three terminal complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for btten fittings complete all as specified and as directed.
S & F stepped type electronic fan regulator flush type on the existing complete all as specified and as directed.
Supply & fixing main stream battens fitting LED 20 watt tube light fitting 1x 4 feet long battens fitting and all accessories, tube, prewired and flexible wire twin core from ceiling rose to terminal block including taken down old unserviceable and make good the disturbed surface complete all as specified and as directed. Cat Part No. LHEXBLP7PN1W020 of make Havells or equivalent Modal of Phillips/CG.
Supply & fixing in repair 1X2 feet, 9 watt LED tube main stream battens fittings nano diffuser technology to ensure minimum loss in light transmitted, zero mercury content green lighting solution with and including 1X2 feet LED tube including necessary accessories and electric connection complete Cat Part No.LHEXBLP7IN1W009 of make Havells or equivalent Model of Phillips/CG.
Supply and fix in repair 2'x2' energy efficient recess mounting 24 watt LED lumanaries fixing for POP ceiling housing including LED lamps other accessories and necessary electric connection after and including taking down old unserviceable fittings complete all as specified and as directed. Cat Part No.LHEBAEP7IZ1W024 of make Havells or equivalent Model of Phillips/CG.
Supply and fixing LED lights fitting 1X 16W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-Charge
M & L for MCB SP of rating 6 to 32 Amps 240 V of capacity 10 KA complete all as specified and as directed.
M & L for MCB SPN of rating 40 to 63 Amps Amps 240 V,of capacity 10 KA complete all as specified and as directed.
M&L MCB Isolator Triple pole and neutral 415 Volt and current carrying capacity 63 Amp complete all as specified and as directed.
Taking down MCB DB of any capacity and making good disturbed area complete all as specified and directed by Engr-in-Charge
Supply and fixing in repair MCB DB TPN (double door) 4 Ways 415 volt including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed by the Engr-in-Charge.
Supply and fixing in repair MCB DB SPN (double door) 8 Ways 240 volt including bus bar neutral link, earth bar and din rail, recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and directed by the Engr-in-Charge.
M & L Sheet Metal enclosures for DB's for MCBs Single pole & neutra 4 way 240 volt with out bus bar single door complete all as specified and directed by the Engr-in-Charge.
Material and labour for concealed sub main wiring in PVC conduit pipe along with earth wire with FRLS PVC insulated copper conductor, single core, cable in surface of size 2 x 6 sq mm + 1 x 6.0 sq mm earth wire. into rigid non metalic PVC conduit of suitable size ISI Marked including of all accessories complete all as specified and directed by the Engr-in-Charge. Note:- Two run of 06 sqmm cable, one run of 06 sqmm cable and one run of PVC conduit will be measured as single length.
Material and labour for concealed sub main wiring in PVC conduit along with earth wire with FRLS PVC insulated copper conductor, single core, cable in surface of size 2 x 2.5 sq mm + 1 x 2.5 sq mm earth wire. into rigid non metalic PVC conduit of suitable size ISI Marked including of all accessories complete all as specified and directed by the Engr-in-Charge. Note:- Two run of 2.5 sqmm cable, one run of 2.5 sqmm cable and one run of PVC conduit will be measured as single length.
Material and labour for concealed sub main wiring in PVC conduit along with earth wire with FRLS PVC insulated copper conductor, single core, cable in surface of size 4 x 10 sq mm + 2 x 10 sq mm earth wire.into rigid non metalic PVC conduit of suitable size ISI Marked including of all accessories complete all as specified and directed by the Engr-in-Charge. Note:- Four run of 10 sqmm cable, two run of 10 sqmm cable and one run of PVC conduit will be measured as single length.
Supply and fixing of exhaust fan AC 230/240V, 300 mm sweep complete with louvre including provision of hole for fixing of exhaust fan complete all as specified and directed by the Engr-in-Charge.
Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in ltiple optics complete with IP 65/66 protection complete all as specified and directed by the Engr-in-Charge.
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm hick, buried directly in ground (earth pit not less than 2.25 metres deep below round level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical Plate No.3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed.
S&F Earth continuity conductor or main earthing lead fixed to wall on batten or ecess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or ny other indicated situation for loop earthing etc. as required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
S&F for Test point terminal block made of gun metal or phosphorous bronze size 75 x 75 x 25 mm, drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw including removing of existing test teminal block complete all as specified and directed by the Engr-in-Charge.
M&L for removing existing aluminium strip for roof conductors & down conductors/ and making straight of suitable size and screws etc complete all as specified and directed.
S&F Aluminium strip 25 x 3.15 mm with saddles and fixing screws etc for roof conductors and down conductors above ground in high rise bldg of G+3 complete all as specified and directed.
Supply and fixing porcelain vitreous white insulator, fixed on wall / roof / block with galvanised iron nuts, bolts and washers for separating the aluminium or GI earthing strip and wall / roof / block complete all as specified and directed.
Fixing only MCB SP/SPN/TPN of any discreption including necessary connection with suitable size of copper cable complete all as specified and directed.
Supply and fixing TPN vertical type DBs double door 08 way (for Single / Three Phase Outgoing) suitable for MCB / RCCB / Isolator as incomer complete all as specified and directed.
Supply and fixing DPX 3 160 thermal magnetic protection MCCB 160 Amps 4 Pole 25 KA complete all as specified and directed.
Supply and fixing Blanking Plate For DB complete all as specified and directed.
M & L for removing of existing Energy meter of any capacity and make from wall disconnect all electric connection and replacement unsv component including re-fixing arrangement by means of suitable size lugs,wire and screws etc complete make good of disturbed surface testing etc complete all as specified and directed.
Taking down fan, sealing cable end, dismantling blades and removing fan and blades to store and replacement minor parts of metal bush, ball bearing and refixing to its original location after painting of ceiling fans complete, with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
Supply and fixing in repair digital timer switching ON/OFF lights and other electric divices according to the daily sun rising/setting of time with combination function for creating switching programs according to the astronomical time and or fixed preset times including taking down old unserviceable and make good the disturbed surface complete all as specified and directed.
S&F ceiling fan of size 1200mm sweep, single phase heavy duty with their all accessories fixed properly on roof surfaces including making hole to fixing 'S" hook including cutting of roof/ceiling finishing with cement plaster and making good to the distuberd surface of roof internal sides and two coats of distumber to match with the existing colour white/colour wash including connecting/testing complete all as specified and directed.
S&F Down Rod of Size 60 cm with suitable arrangment for cealing fan hanging from S frame hook complete all as specified and directed.
Materials & labour for power supply unit consisting of starter with 20 amps over load protection, MCB-20 amps, 2 pin & earth plug socket including MS/PVC box & top cover for AC complete all as specified and directed.
Material and Labour for concealed sub main wiring in PVC conduit with PVC (FRLSH) insulated & unshaethed two runs of 4.0 sqmm single core multistrand copper conductor cable 1100 Volts grade alongwith one run of 2.5 sqmm PVC(FRLSH) insulated & unshaethed copper conductor cable 1100 Volts grade, connected to common earth dolly as earth continuity conductor drawn through and including PVC casing capping of suitable size including making good of disturbed surfaces complete all as directed by the Engr-in-Charge. [Note: - Two runs of 4.0 sqmm and one run of 2.5 sqmm cable and one run of casing capping shall be considered as one unit.]
Supply and fixing vertical storage type water heater (Geyser) of capacity 25 Ltrs with copper tank, 230 volts fixing the geyser with four Nos of rag bolts and making the electrical/water supply connection including testing after installation complete all as specified and directed.
Supply and fixing for single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCBs, 230 volts flush type with fuse & neon indicator complete all as specified and directed.
Supply and fix PVC inlet connector pipe 450mm long for geyser, heavy duty,with brass coupling both ends sutiable to fix inlet of geyser complete all as specified and directed.
Supply and fix 450mm long brass CP connection with 2 nuts without nipple suitable for geysers complete all as specified and directed.
Supply and fixing of GI pipe 25 mm dia for connection for incoming cold water and outgoing hot water all as specified and directed by Engr-in- cahrge .
Supply and fixing stop valves , cast copper alloy , screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed of size 25mm dia complete all as specified and directed.
Supply and fixing bib taps, cast copper alloy fancy type with with crutch or butterfly handle, screwed both ends for iron pipe or for brass ferrule and fixed of size 15 mm dia complete all as specified and directed.
DNS CONSTRUCTION COMPANY
NIRMAL SALES CORPORATION
CHOWDHURY CONSTRUCTION CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .