ENERGY AUDIT OF E/M INSTALLATION AND REPAIRS / RECTIFICATION OF CERTAIN CONNECTED ITEMS AT ARMY AREA UNDER GE(WEST) COLABA
2021_MES_438240_1
84028/W/E8
Open Tender
Civil Works
Item Rate
90 days
GE WEST COLABA
Please Refer The Tender Documents
7 documents required · 7 mandatory
₹500
GE WEST COLABA
₹30,000
16 Jun 2021
29 Apr 2021
20 May 2021
29 Apr 2021
19 May 2021
7 May 2021
29 Apr 2021 - 12 May 2021
Amount
M & L for Electrical safty energy audit of Main Recieving Station, Electric sub stations , HT/LT Switch gears, LT panel board and feeder piller boxes, HT/LT cable Net working system , water supply pumping installations and Air Conditioning Plants based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M(W) Colaba ,Mumbai as per following details : (i) conducting servy of electric Sub stations -13 Nos (ii) conducting servy of Pump houses -17Nos (iii) On ground site check of all LT Panel boards and feeder piller boxes. (iv) Checking of earth resistance , Load balancing (v) Checking of loose connections (vi) Testing of APFC Panels and power factor Identification and devlopment of energy conservation opportunities.(ENCON) (vii)Comparition and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture
M & L for Electrical safty energy audit of LIFT Installations and ,Fire fighting system based on inventory of energy using existing system and assumption of current operating conditions, calculations of energy uses under AOR of AGE E/M(W) Colaba ,Mumbai as per following details : (i) conducting servy of all Machine Rooms of lift -51 Nos (ii) conducting servy of fire fighting Pump houses -5Nos (iii) On ground site check of all control Panel boards and fire panel boards. (iv) Checking of earth resistance in Machine Room , Load balancing (v) Checking of loose connections (vi) Identification and devlopment of energy conservation opportunities.(ENCON) (vii) Comparition and cost benefit analysis by low medium and long term measures. (viii) Submission of energy audit report along with recommendations as per annexture . Notes : (i) Energy audit service provider must be having certification of BUREAU OF ENERGY EFFICIENCY (ii)Energy audit service provider must be having minimum experience of 10 years with Central Govt and Statae Govt. (iii)Energy audit service provider must be having all type testing digital instruments for thermography, earth resistance tester multimeter ,magger etc.
Supply and fix Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 95 Sqmm X 3.5 core including disconnecting /getting out old unserviceable cable piece complete all as specified and directed. Makes :(i) Cable Corporation of India, Mumbai, (ii) Havells india ltd, (iii) Universal Cables Ltd, Satna, (iv) Asian Cables (RPG), (v) Gloster, (vi) RPG Cables Ltd , Thane, (vii) Finolex, (viii) Polycab
Supply and fix Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 70 Sqmm X 3.5 core including disconnecting /getting out old unserviceable cable piece complete all as specified and directed. Makes : (i) Cable Corporation of India, Mumbai, (ii) Havells india ltd, (iii) Universal Cables Ltd, Satna, (iv) Asian Cables (RPG), (v) Gloster, (vi) RPG Cables Ltd , Thane, (vii) Finolex, (viii) Polycab
Supply and fix Cable, LT XLPE insulated screened, PVC bedded galvanized steel strip or wire armoured electric power cable heavy duly , IS-7098 Part-II, with stranded aluminum conductor LT 1100 volts grade of size 50 Sqmm X 3.5 core including disconnecting /getting out old unserviceable cable piece complete all as specified and directed. Makes : (i) Cable Corporation of India, Mumbai, (ii) Havells india ltd, (iii) Universal Cables Ltd, Satna, (iv) Asian Cables (RPG), (v) Gloster, (vi) RPG Cables Ltd , Thane, (vii) Finolex, (viii) Polycab
M&L in repairs earth continuity conductor or main earthing lead fixed to wall or recess or chases or buried in ground or drawn in GI pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including clamping jointing complete of size 25 x 3 mm aluminium strip all as diretced .
Supply and fixing for MCCB 3 Pole, 415 V, fixed type, 100 Amps in replacemnet at existing control panel boards with breaking capacity 16 KA all as specified and directed. Makes : (i) Larsen & Tubro, (ii) ABB, (iii) Legrand, (iv) Siemens, (v) Schneider
Supply and fixing for MCCB 3 Pole, 415 V, adujtable type, 160 Amps in replacemnet at existing control panel boards with breaking capacity 36 KA all as specified and directed. Makes : (i) Larsen & Tubro, (ii) ABB, (iii) Legrand, (iv) Siemens, (v) Schneider
Supply and lay graded coarse aggregate of 20mm size underneath of transformer yard all as specified and directed.
M&L for PCC 1:3:6 type C1 using 20mm grade stone aggregate as in Meter rooms and other electric installtions complete all as secified.
Taking down plastering on lathing (other than wire - netting), without removing lathing, in cement mortar from the existing transformer platform complete all as specified and directed.
M&L for rendering cement plaster 10mm thick 1:3, on fair faces of existing transformers platform complete all as specified and directed.
M & L for Earthing complete with GI earth plate electrode 60 cm X 60 cm X 6 mm thick, burried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.50 mtr below normal ground level connected to GI earth lead strip 32 x 6 mm dia by means of GI bolts, nuts, check nuts, washers made out of GI/steel, all as shown on electrical plate No3 of MESschedule part-I, earth lead strip connected to indicated position including concrete pit in PCC(1:3:6, C1),Precast RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/LT distribution panel connected with 70 Sqmm size of cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable by necessary excavation/earth work fro extend extra length of Cable and refixing the same, testing complete all as specified and directed.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/LT distribution panel connected with 95 Sqmm size of cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable by necessary excavation/earth work fro extend extra length of Cable and refixing the same, testing complete all as specified and directed.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/LT distribution panel connected with 120 Sqmm size of cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable by necessary excavation/earth work fro extend extra length of Cable and refixing the same, testing complete all as specified and directed.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/LT distribution panel connected with 150 Sqmm size of cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable by necessary excavation/earth work fro extend extra length of Cable and refixing the same, testing complete all as specified and directed.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/LT distribution panel connected with 240 Sqmm size of cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable by necessary excavation/earth work fro extend extra length of Cable and refixing the same, testing complete all as specified and directed.
S&F in repair aluminium lugs duly crimped at end termination of Transformer/LT distribution panel connected with 300 Sqmm size of cable including all allied works such as disconnecting cable from supply site, removing from gland, making equal length of each core of cable by necessary excavation/earth work fro extend extra length of Cable and refixing the same, testing complete all as specified and directed.
EESSI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .