Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.6 LAccepted-AOC 2ND FLOOR A I ESTATE MOHAN NAGAR GAZIABAD 2023R10524 | L1 | Accepted-AOC L1 | |
| 2 | L2₹80.8 L+₹4.5 L (5.83%)Rejected-Finance PLOT NO 901 A INDL AREA PHASE II CHANDIGARH 160002 | CHANDIGARH | CHANDIGARH | CHANDIGARH | 160002 | L2 | Rejected-Finance L2 |
Tender Value
₹71.2 L
EMD Value
₹1.4 L
Closing Date
22 Aug 2024, 5:00 pmClosed
PRAMESH Kumar
ED - Hisar
Construction of 200 Bedded Hospital in Sector-9 at Fatehabad (Solar water heating system and Solar Power Plant in main Admin Block and Mortuary Block)
2024_HRY_399869_1
2024F5364B19 10D7 4773 A782 5339D8931DE1666BAR
Open Tender
Electrical Works
Works
420 days
Fatehabad
2 documents required · 2 mandatory
₹5,000
₹1.4 L
Yes
17 Dec 2024
13 Aug 2024
23 Aug 2024
13 Aug 2024
22 Aug 2024
13 Aug 2024
Amount
[22.85.3]Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 3. 25 mm nominal outer dia Pipes
[22.88.4]Providing and fixing G.I. pipes complete with G.I. fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on wall 4. 32 mm dia nominal bore
[23.22.4.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 4.1. Supply and erection of double door sheet steel enclosure distribution board suitable for MCBS and ELCBS etc. recessed in wall including bonding to earth with all labour and material required to complete the job in all respect up to the entire satisfaction of the Engineer-in-Charge of the work. SPN DB Double Door 4 way ( 2 incoming and 2 outgoing)
[23.22.5.4]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.4. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. Double pole
[23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE
[32.70.3]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC (c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency (d) Data Monitoring System complete with accessories. (e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. (f) Lightning and surge voltage protection. (g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 3. Above 100 kWp and up to 500 Kwp
Supply and erection of Booster Motor 1 HP complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST) Make :- Kirloskar/ Crompton/ CRI
Supply and erection of Electric Heater with thermostat 5 KW complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.(Excluded GST) Make Green Energy/ Radiant/ Inter Solar.
Supply and erection of Temperatures meter for solar water heater complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.(Excluded GST) Make Green Energy/ Radiant / Inter Solar.
Supply and erection of Gate valve in 25mm complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST)Make:- Jindal / Tata/ Parkash.
Supply and erection of Gate valve in 32mm. complete all labor and material required to complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works.(Excluded GST) Make:- Jindal / Tata/ Parkash.
Supply and erection of cold water storage tank of 1000 LPD in Four layer with stand of MS in height 7.8ft. with (Civil work for Cold water Storage Tank and Hot water Pipe line and For Plant) complete with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works)(Excluded GST) Make :- Syntax/ Ganga/ Jindal.
Supply and erection of cold water storage tank of 500 LPD in Four layer with stand of MS in height 7.8ft. with (Civil work for Cold water Storage Tank and Hot water Pipe line and For Plant) complete with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works) (Excluded GST) Make :- Syntax/ Ganga/ Jindal.
Supply and erection of Electric Heater with thermostat 3 KW complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST) Make Green Energy/ Radiant/ Inter Solar
Supply and erection of pvc sheathed conductor cable copper 6sqmm 4 core 1100 volts grade in pipe of suitable site. Design, Supply, Installation, Testing. Commissioning of power cables/control cables, cable trays, glands with required accessories, etc. from all equipment, pumps to control panel complete as specified and shown in drawings with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST) Make Polycab/ RR kabel/ Grandlay.
Supply of LT Power Ard. Cables of Aluminium Conductor complete with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-in-charge of the work. Make:- Grandley/ KEI/ RR Kabel/ Polycab. (Rates are excluding GST) 16 Sqmm 2 Core Ard. Cable
Supply and erection of 25 mm dia GI Pipe B Class for hot water with 100mm Density of rock wool insulation with density 48kg/m3. complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST) Make:- Jindal / Tata/ Parkash
Supply and erection of 15 mm dia GI Pipe B class for hot -water with 100mm Density of rock wool insolation with density 48kg/m3 complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. (Excluded GST) Make:- Jindal / Tata/ Parkash.
Inter Solar Systems Pvt. Ltd. (BID ID -1145930)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .