| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAdmitted-Finance | ₹22.3 L | L1 | Admitted-Finance |
| 2 | L2₹26.7 LAdmitted-Finance 1ST FLOOR KRISHNA TOWERS OPP TO THRIKKAKARA TEMPLE THRIKKAKARA P O COCHIN 682 021 | ERNAKULAM | KERALA | 682021 | ₹26.7 L | L2 | Admitted-Finance |
| 3 | L3₹26.9 LAdmitted-Finance | ₹26.9 L | L3 | Admitted-Finance |
| 4 | L4₹27.7 LAdmitted-Finance | ₹27.7 L | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Bidder is technically disqualified due to non submission of qualification documents as per NIT |
| Sl No | Description | Qty | Unit | SM ENTERPRISES L4 | STERLING AND WILSON PVT LTD L2 | D R ENTERPRISE L3 | Parma Clima Technologies India Private Limited L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Providing and fixing of AHU copper cooling coil of 4 rows with size 1890 mm (W) x 1210 mm (H) for 9500 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified | 1 | each | 2,95,284 ₹3.0 L | 3,14,575.02 ₹3.1 L | 3,30,000 ₹3.3 L | 2,43,211 ₹2.4 L |
| 2.00 | Providing and fixing of AHU copper cooling coil of 6 rows with size 2410 mm (W) X 1400 mm (H) for 11000 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified | 1 | each | 6,53,476 ₹6.5 L | 5,96,838.1 ₹6.0 L | 5,65,000 ₹5.7 L | 4,86,423 ₹4.9 L |
| 3.00 | Providing and fixing of AHU copper cooling coil of 6 rows with size 1660 mm (W) X 1250 mm (H) for 8500 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified | 1 | each | 4,01,886 ₹4.0 L | 3,84,480.58 ₹3.8 L | 4,01,000 ₹4.0 L | 3,16,029 ₹3.2 L |
| 4.00 | Providing and fixing of AHU copper cooling coil of 6 rows with size 2420 mm (W) X 1400 mm for 12500 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified | 1 | each | 6,53,476 ₹6.5 L | 5,98,871.24 ₹6.0 L | 6,60,000 ₹6.6 L | 4,87,879 ₹4.9 L |
| 5.00 | Providing and fixing of AHU copper cooling coil of 4 rows with size 1740 mm (W) X 640 mm (H) for 6000 cfm CSAHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified | 1 | each | 1,43,788 ₹1.4 L | 1,94,272.84 ₹1.9 L | 2,80,000 ₹2.8 L | 1,36,897 ₹1.4 L |
| 6.00 | Providing and fixing of AHU copper cooling coil of 6 rows with size 1640 mm (W) X 440 mm for 4000 cfm CSAHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified | 1 | each | 1,39,761 ₹1.4 L | 1,95,898.88 ₹2.0 L | 2,40,000 ₹2.4 L | 1,03,401 ₹1.0 L |
| 7.00 | Dismantling of defective AHU copper cooling coil by cutting, welding etc. and shifting the same from existing position to dump yard withing 100 mtrs etc. complete as reuired | 6 | lot | 9,500 ₹57,000 | 28,450.98 ₹1.7 L | 5,000 ₹30,000 | 21,845 ₹1.3 L |
| 8.00Providing and fixing in position the following MS HEAVY class chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbow, tees, etc. and confirming to the specifications as detailed in the relevant chapter in the document. | |||||||
| 8.01 | 50 mm dia | 30 | meter | 5,500 ₹1.6 L | 30.68 ₹920.40 | 850 ₹25,500 | 1,151 ₹34,530 |
| 9.00Proving and fixing of following Chilled water pipe insulation with 25 mm thk. Al. Foil Faced Closed Cell Nitrial RubberXLPE pipe section.The pipe section shall be treated with thermal protection layer of pidilite or equivalent make covered with chiken wire mesh and 10mm thick cement sand plaster and 1 layes of terfelt and finally painted the bituminus paint in 2 layers. All the pipes will be as per IS 1239 with all necessary wooden supports on MS / Civil pedestals etc as required as per site condition and as per specification with MS Heavy class pipe, fittings etc complete as required.. | |||||||
Tender Value
₹28.4 L
EMD Value
₹57,000
Closing Date
6 Apr 2026, 2:00 pmClosed
Superintending Engineer
IPM Section, IIT Guwahati
Replacement of defective AHU Copper Coil and associated works in various places of Academic complex at IITG
2026_IITG_902859_1
IITG/IPM/NIT/C/2025-26/124
Open Tender
Electrical Works
90 days
IIT Guwahati
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
IIT GUWAHATI
₹57,000
21 May 2026
17 Mar 2026
7 Apr 2026
17 Mar 2026
6 Apr 2026
17 Mar 2026
Providing and fixing of AHU copper cooling coil of 4 rows with size 1890 mm (W) x 1210 mm (H) for 9500 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified
Providing and fixing of AHU copper cooling coil of 6 rows with size 2410 mm (W) X 1400 mm (H) for 11000 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified
Providing and fixing of AHU copper cooling coil of 6 rows with size 1660 mm (W) X 1250 mm (H) for 8500 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified
Providing and fixing of AHU copper cooling coil of 6 rows with size 2420 mm (W) X 1400 mm for 12500 cfm AHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified
Providing and fixing of AHU copper cooling coil of 4 rows with size 1740 mm (W) X 640 mm (H) for 6000 cfm CSAHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified
Providing and fixing of AHU copper cooling coil of 6 rows with size 1640 mm (W) X 440 mm for 4000 cfm CSAHU i/c positioning, cutting, welding, fixing etc. complete as required. The cooling coil should be AHRI-410 & UL certified
Dismantling of defective AHU copper cooling coil by cutting, welding etc. and shifting the same from existing position to dump yard withing 100 mtrs etc. complete as reuired
Providing and fixing in position the following MS HEAVY class chilled water piping, cut to required length and installed with welded joints, including all necessary fittings such as elbow, tees, etc. and confirming to the specifications as detailed in the relevant chapter in the document.
50 mm dia
Proving and fixing of following Chilled water pipe insulation with 25 mm thk. Al. Foil Faced Closed Cell Nitrial RubberXLPE pipe section.The pipe section shall be treated with thermal protection layer of pidilite or equivalent make covered with chiken wire mesh and 10mm thick cement sand plaster and 1 layes of terfelt and finally painted the bituminus paint in 2 layers. All the pipes will be as per IS 1239 with all necessary wooden supports on MS / Civil pedestals etc as required as per site condition and as per specification with MS Heavy class pipe, fittings etc complete as required..
50 mm dia
Proving and fixing of Condensate drain water pipe with all accessories complete as required.
providing and fixing of Condensate drain water insulation with 19 mm thk. Al Foil Faced Closed Cell Nitrial Rubber Pipe Section complete as required.
BUYBACK of defective AHU Cu Coil of following capacity
Buyback of AHU copper cooling coil of 4 rows with size 1890 mm (W) x 1210 mm (H) for 9500 cfm AHU i/c cutting, welding etc. complete as required
Buyback of AHU copper cooling coil of 6 rows with size 2410 mm (W) X 1400 mm (H) for 11000 cfm AHU i/c cutting, welding etc. complete as required
Buyback of AHU copper cooling coil of 6 rows with size 1660 mm (W) X 1250 mm (H) for 8500 cfm AHU i/c cutting, welding etc. complete as required
Buyback of AHU copper cooling coil of 6 rows with size 2420 mm (W) X 1400 mm for 12500 cfm AHU i/c cutting, welding etc. complete as required
Buyback of AHU copper cooling coil of 4 rows with size 1740 mm (W) X 640 mm (H) for 6000 cfm CSAHU i/c cutting, welding etc. complete as required
Buyback of AHU copper cooling coil of 4 rows with size 1640 mm (W) X 440 mm for 4000 cfm CSAHU i/c cutting, welding etc. complete as required
Please Enable Macros to View BoQ information
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
DetailNITFinal.pdf
Tender Documents • 0.63 MB
BOQ_948964.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid