Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 CrAdmitted-Finance MD 1 236 SECTOR D1 LDA COLONY KANPUR ROAD LUCKNOW U P PIN 226012 | LUCKNOW | UTTAR PRADESH | 226012 | L1 | Admitted-Finance | |
| 2 | L2₹1.4 Cr+₹6.3 L (4.63%)Admitted-Finance PLOT NO 127 3 A RATNASAGAR FLATS SECTOR 19 GANDHINAGAR 382019 | GANDHINAGAR | GANDHINAGAR | GUJARAT | 382019 | L2 | Admitted-Finance | |
| 3 | L3₹1.4 Cr+₹7.4 L (5.39%)Admitted-Finance 103 HARIAKSH PLAZA HOSPITAL ROAD BHUJ KUTCH GUIARAT 370001 | BHUJ | KUTCH | GUJARAT | 370001 | L3 | Admitted-Finance | |
| 4 | L4₹1.5 Cr+₹8.1 L (5.88%)Admitted-Finance 21 GURUKRIPA PATIL LAYOUT GOPLA NAGAR NAGPUR 440022 | NAGPUR | NAGPUR | MAHARASHTRA | 440022 | L4 | Admitted-Finance | |
| 5 | L5₹1.5 Cr+₹9.7 L (7.04%)Admitted-Finance | L5 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Asha Enterprises L4 | divyarsh entrprise L2 | SNEH TRADERS L8 | DMA PROJECTS L7 | Panwar Construction Co. L5 | VIJAY CONSTRUCTION CO L3 | M/s Ram Singh Agarwal L6 | R K CONTRACTOR AND SUPPLIERS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed. | 295 | Cum | 110 ₹32,450 | 100 ₹29,500 Lowest | 100 ₹29,500 Lowest | 320 ₹94,400 | 175 ₹51,625 | 150 ₹44,250 | 150 ₹44,250 | 200 ₹59,000 |
| 2.00 | Excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 Sqm on plan and n.exc 1.5 mtr in depth and getting out complete in soft/loose soil complete all as specified and directed. | 327.16 | Cum | 300 ₹98,148 | 100 ₹32,716 Lowest | 330 ₹1,07,962.8 | 310 ₹1,01,419.6 | 160 ₹52,345.6 | 320 ₹1,04,691.2 | 140 ₹45,802.4 | 250 ₹81,790 |
| 3.00 | S & F of precast footing design for single column placement of size (base +pedestal) 1450 mm x 900mm x 800 mm ,have base of 1450 mm x 900mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 550 mm x 600mm (hollow part 250 mm x 250 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with BIS ,JIS, and ISO-9001 standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1015 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 117 | EACH | 28,000 ₹32,76,000 | 28,500 ₹33,34,500 | 46,000 ₹53,82,000 | 29,000 ₹33,93,000 | 32,000 ₹37,44,000 | 27,900 ₹32,64,300 | 32,370 ₹37,87,290 | 27,000 ₹31,59,000 Lowest |
| 4.00 | S & F of precast footing design for double column placement of size (base +pedestal) 1450 mm x 1125 mm x 800 mm ,have base of 1450 mm x 1125 mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 775 mm x 600mm (hollow part 250 mm x 475 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1280 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 42 | Each | 35,000 ₹14,70,000 Lowest | 36,660 ₹15,39,720 | 55,000 ₹23,10,000 | 36,000 ₹15,12,000 | 35,850 ₹15,05,700 | 35,680 ₹14,98,560 | 36,000 ₹15,12,000 | 35,000 ₹14,70,000 Lowest |
| 5.00 | S & F of precast I-shaped column of size 3000mm x 200mm x 200mm, having flange thickness of 60 mm and web thickness 80 mm will place on precast footing and will be grouted , having a bolts fixed at top of column, having 4 mm dia high tensile tendon steel 10 nos in each column which is made of high performance self compacting concrete (SCC) of M-40 grade, cured under controlled factory conditions through steam curing,. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. concrete mix design of IS:9103 with weight of each column at least 228 kg (tolerance limit 1.5%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 203 | Each | 7,000 ₹14,21,000 | 6,100 ₹12,38,300 | 8,200 ₹16,64,600 | 6,200 ₹12,58,600 | 7,000 ₹14,21,000 | 6,300 ₹12,78,900 | 7,273 ₹14,76,419 | 6,000 ₹12,18,000 Lowest |
| 6.00 | S & F of precast panel have both side design as approved by GE of size 3000mm x 1200 mm x 75mm having 4 mm dia high tensile tendon steel 10 nos in each panel which is made of high performance self compacting concrete (SCC) of M-40 grade with high tensile tendon steel, cured under controlled factory conditions through steam curing. All manufacturing process must comply with Indain standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each panel at least 675 kg (tolerance limit 1%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
Note:-
(i) Design given in the drawing is tentative, actual design will be as per sample approval.
(ii) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(iii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 318 | Each | 21,000 ₹66,78,000 | 20,202 ₹64,24,236 | 32,500 ₹1,03,35,000 | 21,000 ₹66,78,000 | 19,600 ₹62,32,800 | 20,345 ₹64,69,710 | 19,950 ₹63,44,100 | 19,000 ₹60,42,000 Lowest |
| 7.00 | M&L for Brickwork with (using old size bricks) fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. | 40 | Cum | 6,500 ₹2,60,000 | 6,400 ₹2,56,000 | 7,300 ₹2,92,000 | 5,570 ₹2,22,800 Lowest | 6,200 ₹2,48,000 | 6,500 ₹2,60,000 | 6,190 ₹2,47,600 | 6,250 ₹2,50,000 |
| 8.00 | M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) in foundation filling and mass concrete complete all as specified and directed. | 36.42 | Cum | 3,800 ₹1,38,396 | 3,550 ₹1,29,291 | 3,200 ₹1,16,544 Lowest | 4,200 ₹1,52,964 | 3,450 ₹1,25,649 | 3,700 ₹1,34,754 | 3,400 ₹1,23,828 | 3,500 ₹1,27,470 |
| 9.00 | Use & waste of form work rough finished surfaces of concrete side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work flat, vertical complete all as specified and directed. | 25.2 | Sqm | 400 ₹10,080 | 410 ₹10,332 | 380 ₹9,576 | 400 ₹10,080 | 325 ₹8,190 Lowest | 600 ₹15,120 | 400 ₹10,080 | 350 ₹8,820 |
| 10.00 | Use & waste of form work to sides of pillar, posts, struts, columns etc complete all as specified and directed. | 30.03 | Sqm | 400 ₹12,012 | 370 ₹11,111.1 | 600 ₹18,018 | 310 ₹9,309.3 Lowest | 325 ₹9,759.75 | 600 ₹18,018 | 400 ₹12,012 | 360 ₹10,810.8 |
Tender Value
₹1.5 Cr
EMD Value
₹2.9 L
Closing Date
12 Oct 2026, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (WEST) LUCKNOW
GE (WEST) LUCKNOW PINCODE-226002
SPECIAL REPAIR TO FENCING AND BOUNDARY WALL OF SURYA SAINIK INSTITUTE AND ALLIED WKS UNDER GE (WEST) LUCKNOW
2026_MES_789640_1
GE/W/LKO/T-95 OF 2026-27
Open Tender
Civil Works
Item Rate
150 days
GE (WEST) LUCKNOW
As per NIT and Tender document
8 documents required · 8 mandatory
₹1,000
GE (WEST) LUCKNOW
₹2.9 L
Yes
23 Nov 2026
16 Sept 2026
14 Oct 2026
16 Sept 2026
12 Oct 2026
30 Sept 2026
16 Sept 2026 - 23 Sept 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Demolition of brick work built in cement mortar or cement lime mortar complete all as specified and directed. | 295 | Cum | - | - |
| 2 | Excavation in trenches n.exc 1.5 m in depth for foundation n.exc. 10 Sqm on plan and n.exc 1.5 mtr in depth and getting out complete in soft/loose soil complete all as specified and directed. | 327.16 | Cum | - | - |
| 3 | S & F of precast footing design for single column placement of size (base +pedestal) 1450 mm x 900mm x 800 mm ,have base of 1450 mm x 900mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 550 mm x 600mm (hollow part 250 mm x 250 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with BIS ,JIS, and ISO-9001 standards. The curing process must be maintained using RO water and chiller plants for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1015 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 117 | EACH | - | - |
| 4 | S & F of precast footing design for double column placement of size (base +pedestal) 1450 mm x 1125 mm x 800 mm ,have base of 1450 mm x 1125 mm x 200 mm and hollow pedestal on base having dimensions of 550 mm x 775 mm x 600mm (hollow part 250 mm x 475 mm x 600 mm ), footing is made of high performance self compacting concrete (SCC) of M-25 grade has been placed on 100mm thick PCC 1:4:8 type D-2 (using 40mm graded stone aggregate) after proper compaction of soil, footing made with Fe 500/550d grade TMT steel reinforcement bars, cured under controlled factory conditions through steam curing. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each SCC footing at least 1280 kg (tolerance limit 3%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 42 | Each | - | - |
| 5 | S & F of precast I-shaped column of size 3000mm x 200mm x 200mm, having flange thickness of 60 mm and web thickness 80 mm will place on precast footing and will be grouted , having a bolts fixed at top of column, having 4 mm dia high tensile tendon steel 10 nos in each column which is made of high performance self compacting concrete (SCC) of M-40 grade, cured under controlled factory conditions through steam curing,. All manufacturing process must comply with indian standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made of automobile-grade, water-tight steel, enabling the production of highly accurate and consistent components. concrete mix design of IS:9103 with weight of each column at least 228 kg (tolerance limit 1.5%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
(i) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(ii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 203 | Each | - | - |
| 6 | S & F of precast panel have both side design as approved by GE of size 3000mm x 1200 mm x 75mm having 4 mm dia high tensile tendon steel 10 nos in each panel which is made of high performance self compacting concrete (SCC) of M-40 grade with high tensile tendon steel, cured under controlled factory conditions through steam curing. All manufacturing process must comply with Indain standards. The curing process must be maintained using RO water and chiller plants to avoid efflorescence for quality assurance. The formwork used for casting should be made automobile grade water tight steel enabling the production of highly accurate and consistent components. Concrete mix design of IS:9103 with weight of each panel at least 675 kg (tolerance limit 1%), complete all as specified and as shown in drg No 01/03 to 03/03 and directed as per Engineer-in-charge.
Note:-
Note:-
(i) Design given in the drawing is tentative, actual design will be as per sample approval.
(ii) The work pertaining to precast shall be executed by the contractor as per MoU from authorised technician through manufacturer of the precast factory. The sample of MoU is enclosed as per Appx 'B'. The contractor is advised quote their rate accordingly.
(iii) The contractor shall upload with the documents under Technical Bid (Cover-I) "Memorandum of Understanding: (MoU) with Rs 100/- Stamp Paper at least one manufacturers, failing which the bid shall be liable to be rejected. | 318 | Each | - | - |
| 7 | M&L for Brickwork with (using old size bricks) fly ash bricks, straight or curved on plan exc 6m mean radius, built in CM (1:4) complete all as specified and directed. | 40 | Cum | - | - |
| 8 | M&L for cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) in foundation filling and mass concrete complete all as specified and directed. | 36.42 | Cum | - | - |
| 9 | Use & waste of form work rough finished surfaces of concrete side of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams and similar work flat, vertical complete all as specified and directed. | 25.2 | Sqm | - | - |
| 10 | Use & waste of form work to sides of pillar, posts, struts, columns etc complete all as specified and directed. | 30.03 | Sqm | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.24 MB
FENCINGDrawing.pdf
Additional Documents • 0.81 MB
BOQ_885159.xls
BOQ • 0.30 MB
drawingBOUNDARY.pdf
Additional Documents • 1.46 MB
TenderT95.pdf
Tender Documents • 1.09 MB
CORREGENDUMTdate.pdf
PDF • 0.19 MB
CORREGENDUM.pdf
PDF • 0.01 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .