Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.9 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹32.2 L+₹4.1 L (14.5%)Rejected-Finance 201 GANAPATI SANKUL AGASHIVNAGAR MALKAPUR KARAD SATARA MAHARASHTRA 415539 | SATARA | MAHARASHTRA | 415539 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹32.8 L+₹4.7 L (16.6%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹33.1 L+₹5.0 L (17.6%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹36.9 L+₹8.8 L (31.1%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
5 Nov 2024, 6:00 pmClosed
GE NAGROTA
GE NAGROTA
REPAIR MAINTENANCE OF EXTERNAL PIPE LINE WITH CONNECTED WORKS AND REPAIR MAINTENANCE OF DG SETS SECURITY LIGHTS PANELS AND OTHER MISC ITEMS AT 213 TRANSIT CAMP UNDER GE NAGROTA
2024_MES_677996_1
CANO GEN-62/2024-2025
Open Tender
Civil Works - Water Works
Item Rate
270 days
UNDER GE NAGROTA
Class D category a ii
8 documents required · 8 mandatory
₹500
Yes
GE NAGROTA
₹94,000
Yes
30 Nov 2024
5 Oct 2024
12 Nov 2024
5 Oct 2024
5 Nov 2024
19 Oct 2024
Amount
Schedule A Part -I Excavating in trenches n exe 1.5 m wide and not exceeding 1.5 m in depth getting out hard/dense soil complete all as specified and directed.
Returning filling in including spreading, levelling, watering and well ramming in layers n exc 25 cm in hard dense soil complete all as specified and directed.
Removing excavated surplus hard/dense soil to a distance not exceeding 50M and depositing where directed and at a level not exceeding 1.5M above the starting point.complete all as specified and directed.
Supply & Laying in trenches galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site for the following sizes including dismantling and taking out old unserviceable pipe line alongwith fittings from existing connections complete all as specified and directed. Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
150 mm bore pipe
100 mm bore pipe
80 mm bore pipe
50 mm bore pipe
40 mm bore pipe
25 mm bore pipe
20 mm bore pipe
15 mm bore pipe
Supply & Fixing galvanised steel water tubing of medium grade with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc and fixed complete to walls and ceilings or laid in floors including dismantling existing steel tubing and connections fixed at any location all as directed for the following sizes complete all as specified and directed. :- Note:- (i) The rates quoted inclusive of cutting, jointing and testing of the pipe.
40 mm bore pipe
25 mm bore pipe
20 mm bore pipe
15 mm bore pipe
S&F gun metal gate valves with iron wheel head screwed at both ends for iron pipes complete including dismantling of old unserviceable gate valve fixed at any location all as directed for the all as directed for the following sizes:-
50 mm bore
40 mm bore
25 mm bore
20 mm bore
S&F stop valves of cast copper alloy screwed down high pressure with crutch or butterfly handles screwed both ends for iron pipe or for unions and fixed to the following sizes complete all as specified and directed.:-
Bore of pipe 25mm.
Bore of pipe 20mm.
Bore of pipe 15mm.
Supply and fix cast iron sluice valve PN-1.6 conforming to IS 14846/2000, ISI Mark with MS spindle and iron wheel head with both ends flanged with new rubber gasket, bolts and nuts including dismantling of old unserviceable sluice valve fixed at any location all as directed for the following sizes:-
150mm bore
100mm bore
80mm bore
Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 100 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve complete all as specified and directed.
Material & Labour for CI non return valve (NRV) conforming to IS 5312, ISI marked with GM flap of size 150 mm and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable non return valve complete all as specified and directed.
Material & Labour for Construction of valve chambers with 150 mm thick PCC foundation 1:4:8 type D2 using 40 mm graded stone aggregate, 230 mm thick brick masonary wall with sub class 'B' bricks builts in cement mortar 1:4 10 mm thick plastering to brick masonary in cement mortar internally and externally upto 15 cm below ground level, 50 mm thick coping with PCC 1:2:4 type B1 using 20 mm graded crushed trap stone aggregate valve chamber frame cover made of mild steel angles of size 40mm x 40mm x 6mm and cover made of 2.5 mm thick mild steel sheet fixed with mild steel hinges - 02 Nos, locking arrangements with provision of locks and painting the steel surfaces with two coats of synthetic enameled paint over a coat of zinc chromate primer including neccessary earth work, excavation, dismantling of existing valve chmber of any size and pattern and at any position all as specified and directed by Engineer-in-Charge for the following sizes :-
1000CM x 1000CM X 1000CM (Internal Size)
900CM x 900CM X 900CM (Internal Size)
Servicing , painting and greasing & minor repairs of sluice valves of different sizes at any location including replacement of glands.
Attending emergency breakdown/ complaint of damaged water supply GI/ CI/ DI pipe lines in distribution system of and restoring the water supply by stopping the leakage occured by deputing skilled/ semiskilled man power for smooth functioning of water supply system complete, including excavation, returning filling in, ramming, & removing the soil to a distance n. exc. 50 m, cutting & threading all as directed by the EIC or as required at site. Note:-(i)The CI specials and lead joints shall be measured and paid separately as supply only (ii) The cost of necessary earth work and repair to damaged road shall deemed to be included in the quoted rates by the contractor and no extra payment shall paid on this account. (iii)The cost of JCB ( min. of 8 hours work ) for Attending complain shall deemed to be included in the quoted rates by the contractor and no extra payment shall paid on this account.
Supply only the following item to be incorporated against item No. 13
GI union of 50mm bore
GI union of 40mm bore
GI union of 15 mm bore
GI union of 20 mm bore
GI union of 25 mm bore
GI nipple of 40 mm dia 4 inch long.
GI nipple of 50 mm dia 4 inch long.
GI nipple of 15 mm dia 4 inch long.
GI nipple of 20 mm dia 4 inch long.
GI nipple of 25 mm dia 4 inch long.
GI sockets of 50 mm dia.
GI sockets of 40 mm dia.
GI sockets of 25 mm dia.
GI sockets of 20 mm dia.
GI sockets of 15 mm dia.
GI Elbow of 50 mm dia.
GI Elbow of 40 mm dia.
GI Elbow of 25 mm dia.
GI Elbow of 20 mm dia.
GI Elbow of 15 mm dia.
Run lead joints for 150 mm cast iron pipe including spun yarn complete.
Run lead joints for 100 mm cast iron pipe including spun yarn complete.
Run lead joints for 80 mm cast iron pipe including spun yarn complete.
Flanged Joint with rubber or fiber board gasket for 80 mm GI/CI/DI pipe including complete accessories.
Flanged Joint with rubber or fiber board gasket for 100 mm GI/CI/DI pipe including complete accessories.
Flanged Joint with rubber or fiber board gasket for 150 mm GI/CI/DI pipe including complete accessories.
Titan joints for 80 mm cast iron pipe including complete acessories..
Titan joints for 100 mm cast iron pipe including complete acessories.
Titan joints for 150 mm cast iron pipe including complete acessories.
Mechanical joints for 150 mm CI/DI pipe including complete accessories.
Mechanical joints for 100 mm CI/DI pipe including complete accessories.
Mechanical joints for 80 mm CI/DI pipe including complete accessories.
M & L for Cast iron fittings conforming to IS 1538-1989for spigot and socket / flanged pipe upto 150 mm bore such as bends (any type radius and angle) tapers any type (straight, bends) tee, joint piece single branch Y junctiondouble branch cross (all socket or socket and spigot or all flanged ends) coller caps and plug, connecting piece one end flanged and other socketed or spigot and bell mouth complete all as specified,
Supply and fix in repair column pipe for borewell made out of mild steel (MS) 100 mm bore 3 mtr length each welded with MS flanged drilled for nut bolts & washer including rubber gasket. (T&P) as required will be provided by the contractor.
Supply and fix in repair column pipe for Over Head Tank made out of mild steel (MS) 150 mm bore 6 mtr length each welded with MS flanged drilled for nut bolts & washer and rubber gasket including painting with two coat of synthetic enamel paint over a coat of red oxide primer, . (T&P) as required will be provided by the contractor.
Attending emergency breakdown of water supply installation as where directed. lifting defective submersible pumpset, column pipes (any number) from borewell, setting aside and stacking column pipes for reuse, transportation the pumpset to MES store yard for checking of repair work, transportation of serviceable pumpset from MES store yard to bore well, lowering of submersible pumpset with column pippes in the borewell as existing with new nut, bolts and washer including rubber gasket 3 mm thickand making water and electrical connections as existing for running of pump motors complete all as directed. The pumping set after repair shall be lowered as per the manufacture specification. complete all as specified & directed. Note:- (i) T&P required for lifting and lowering for submersible pump set column pipe (any number) shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor.
Repairs to submersible pumpset coupled with motor of capacity 25 to 45 HP 3 Phase, 415 volts onvolving the following operations and rates are included for the following functions and replacement of UNSV parts. (a) Opening of the defective Pump from motor at site, cleaning the covers and parts as applicable in presence of Engineer-in-Charge to ascertain the quantam of defects and repairs involved. (b) Transporting the defective Pump to contractors workshop for repairs as decided by Engr-In-Charge and carrying out the needful repairs.(c) Assembling the Pump with motor after repair.(d) Spray painting the repaired Pump externally with two coats of synthetic enamelled paint of shade as directed by Engr-in-Charge. (e) Transporting the repaired Pump to site, Assembling the Pump with motor and carrying out necessary test in presence of Engineer-in-Charge to establish the functionability of the repaired Pump upto the entire satisfaction of the Engineer-in-Charge. (f) Replacement of unserviceable part of pump like Thrust Bearing, bearing cover sleeve, intermediate shaft, stud ring, neck ring, stainless steel key/sleeve for immpeller shaft, shaft coupler, body bush thrust pad & repair/ Replacement of impeller etc of Pump.
Repairs/rewinding to submersible motor of Cap 25 HP,3 Phase, 415 volts dismanteled from submersible pump set complete as per existing gauge/size/turns super enemalled copper winding wire complete all as per directed by Enginner in Charge at site.
Repairs/rewinding to submersible motor of Cap 45 HP,3 Phase, 415 volts dismanteled from submersible pump set complete as per existing gauge/size/turns super enemalled copper winding wire complete all as per directed by Enginner in Charge at site.
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 150 mm bore and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve complete all as specified and directed
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 100 mm bore and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve all as directed.
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 80 mm bore and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve all as directed.
Material & Labour for CI non return butterfly valve, ISI marked with GM flap of size 50 mm bore and connected with necessary bolts, nuts & washers, gaskets etc complete including dismantling of old unserviceable valve complete all as specified and directed
Supply and fixing as in replacement of 'V' fan belt size C1500 C-57 for blower compressure (evaporator Motor) as per existing complete all as specified and directed
M&L for Servicing / maintenaace of Air Blowers coupled with electric driven AC induction Motor of cap 10 HP three phase including carrying out maintenace check along with following repairs (a) Dismantling of Twin lobe commpressor in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts and assembling the same after filling compressor oil No 320 or as existing, upto indicated level. (b)Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Assembling of motor with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (e) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers, Gear oil of compressor etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid separately under appropriate item of Schedule A
M&L for Servicing Maintenance of centrifugal pump set of sewage water discharge coupled with electrical motor AC of capacity 7.5 HP, three phase, carrying out maintenance check along with following repairs :- (a) Dismantling of centrifugal pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts. (b) Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Checking play of impeller and bushing of pupm and repair/replacement of bushes, gland, sleeves etc. (e) Assembling of motor and pump with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid separately under appropriate item of Sch
M&L for Servicing Maintenance of centrifugal pump set of sewage treated water discharge coupled with electrical motor AC of capacity upto 5 HP, three phase, carrying out maintenance check along with following repairs :- (a) Dismantling of centrifugal pump set in presence of MES representative and display all the parts without damage any portion for inspection of Engr in Charge to ascertain the serviceability of existing parts. (b) Heating, varnishing to stator, rotor with super qualityvarnish and drying out properly. (c) Cleaning, washing and greasing of ball bearing complete. (d) Checking play of impeller and bushing of pupm and repair/replacement of bushes, gland, sleeves etc. (e) Assembling of motor and pump with old serviceable parts and replacement of UNSV parts with new as ordered where necessary. (f) Installation of motor by making connections as per existing and testing on load complete. Note:- Any minor repair and replacement of parts like bearing,gasket, gland packing, Nuts bolts washers etc and labour cost to be included in the quoted rates. (ii) Rewinding of motor if required shall be measured and paid separately under appropriate item of Sch
M&L for Rewinding of AC induction motor 10 HP Three phase dismanteled from Blowers complete as per existing gauge/size/turns super enemalled copper winding wire complete all as per directed by Enginner in Charge at site.
M&L for Rewinding of AC induction motor 7.5 HP Three phase dismanteled from sewage water discharge centrifugal pump set complete, as per existing gauge/size/turns super enemalled copper winding wire complete all as per directed by Engr- in- Charge at site.
M&L for Rewinding of AC induction motor upto 5 HP Three phase dismanteled from treated water discharged centrifugal pump set complete as per existing gauge/size/turns super enemalled copper winding wire complete all as per directed by Enginner in Charge at site.
Material & labour for applying one coat of synthetic enamel paint to all GI/CI pipe, Sewage/Blower Pump motors surfaces of any size inside/out side of Sewage Treatment plant complete with existing colour and marking arrows and all points as existing all as directed by Engr-in-Charge.
Supply & Fix automatic star delta starter in sheet enclosure type (Motor rating 7.5 HP ) suitable for 3 phase,415V,50HZ pump set upto 7.5HP suitable for fixed in the existing electric panel including taking down existing defective star delta starter.
Supply & Fix in replacement of unserviceable star type rubber coupling suitable size for centrifugal pump set upto 10 HP complete as per sample.
Supply & Fix in replacement of unserviceable MS coupling suitable size for coupled to induction motor with centrifugal pump set upto 10 HP complete as per sample.
Supply & Laying in trenches Black Berlia HDPE (High density polyethylene) pipe of size 63 mm internal dia with all fittings such as bends, elbows, tees, unions, nipples, short pieces etc as required at site for the following sizes including dismantling and taking out old unserviceable pipe line alongwith fittings from existing connectionscomplete all as specified and directed Note :- (i) Excavation and earth work shall be measured and paid seperately under relevant item of Sch A (ii) The rates quoted inclusive of cutting, jointing and testing of the pipe.
Disconnecting and removing to workshop opening for repair automatic voltage stabilizer for automatic operation air cooled servo controlled type input voltage 260-440V and output voltage 420 V cap 50 KVA to 160 KVA complete all as specified and as specified and as directed Note : Replacement of the parts if any found worn out/defective shall be measured and paid for separately.
Dismantling and rewinding of dimmer coil with super enameled copper winding wire incl varnishing tapping and insulating material to get same capacity of 50 KVA to 160 KVA
Replacement of electronic circuit plate complete with DC transformers (PCB cold) complete capacity of 50 KVA to 160 KVA
Dismantling of old servo motor and supply and fix new servo motor of existing size and cap complete all as specified and directed.
Dismantling of old carbon brush with carbon holder incl S & F new one complete
Replacement of brass studs fixed for input and output of stabilizer with brass nuts for upto 160 KVA cap
Painting to voltage stabilizer old painted surface of steel after cleaning scrapping and preparing and filling cavities and providing two coat of synthetic enameled cream paint with spray gun process to voltage stabilizer of cap upto 160 KVA
Filtration, dehydration of Voltage Stabilizer oil as drain out from Voltage Stabilizer vide Sch 'A' srl item No. 37 here-in-above to make the oil fit for reuse by improving its dieelectric strength not less than 40 KV below 40 KV dielectric strength oil shall be replaced with new oil (new oil for toping / or for replacement shall be measured and paid separately under appropriate item of Sch 'A') here-in-after.
Supply, treating (dehydrating), filling new Voltage Stabilizer oil in Voltage Stabilizer for topping up levels or for replacement of unfit oil. New oil having dielectric strength not less than 60 KV and shall be conforming to IS 335.
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable of size 25 Sqmm for submersible pump motors Make Havells/ Finolex or equivalent make
Supply and fix Flat three core PVC insulated & PVC sheathed industrial cable for of size 35 Sqmmsubmersible pump motors Make Havells/ Finolex or equivalent make
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised iron strip 25×4mm as earthing lead dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion. connected to earthing test point complete all as specified & directed. Note (i) GI strip and protection pipe 40mm bore upto 7.5 RM lenghth included the quoted rate.
Cutting of existing DI pipe line of 150/100 mm bore in potion for taking connection including excavation and earth work complete all as specified and directed
Servicing of sluice valves cast iron body by greasing/oiling using T&P as required as per manufacturer’s instructions & providing gland rope of superior quality to stop any leakage of sluice valves of size 80 mm to 200 mm diameter including replacement of defective brass check nuts complete all as specified and direceted.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge.
M&L for Cleaning of over head water tank by draining out water from the tank, removing sludge, mud or any other foregin materials from the bottom and internal surface and cleaning by wire brushing, washing internally by using bleaching powder and applying 2 coats of lime washing including re writing the date of cleaning, capacity of the tank with white paint on black back ground & external painting applying two coat of cement base paint including painting of steel and iron surface like railings and CI pipe line etc (welding to steel railing / ladder if required) with two coats of synthetic enamel paint over a coat of primer etc complete for the following capacities all as directed by Engineer-in- Charge for following capacity :-
(a) 50000 gallons at 18m staging.
(b) 100000 gallons at 18m staging.
Material & labour for Pumping out liquid and Taking out setteled sewage sludge/silt from STP Screening Bed & Sewage Collection Chamber, with the help of sewage suction pump and transporting & Disposed off the material minimum 5 KM away from the site to a low lying area (Isolated/No man area) and covering with a layer of soil but not less than 25 cm thick as directed.
Material & labour for Pumping out liquid and Taking out setteled sewage sludge/silt from STP, Clarifire Chamber 01 & 02, sludge digester and reaction room complete, with the help of sewage suction pump and transporting & Disposed off the material minimum 5 KM away from the site to a low lying area (Isolated/No man area) and covering with a layer of soil but not less than 25 cm thick as directed.
Cleaning of STP, Clean water semi under ground sump (Ecko Lake) by draining out water from the sump with portable pump sets, removing sludge, mud or any other foregin materials from the bottom and cleaning internal surface by wire brushing, washing internally by using bleaching powder and applying 2 coats of lime washing including painting with cement base paint internal & external wall surface etc complete. Note :- (i) T&P required for cleaning the OHT/Sewage water tank shall be provided by the contractor. (ii) Necessary safety precautions for workmen shall be the responsibility of the contractor.
Supply and filling PP Floating media to top up the Bio reactors as per existing complete.
Surface excavation not exceeding 30 cm deep and average 15 cm deep and getting out for lifting/ taking out of sludge/silt accumulated inside drying sludge bed of 1-06 Nos bed of size 9.0x9.0x1.2 M, making necessary arrangements and disposal of the same to the out side of 213 Transit Camp Jammu complete all as specified and directed by Engineer in charge
Supply and mix bleaching powder stable Gde-I confrming to IS specification 1665/89 ( second revision ) minimum available chlorine percentage by mass 34%+1% in 25 Kg polythene HDPE bags duly marked date of manufacturing and batch No. of fresh lot. Make Vikram SBP brand of M/S Grasim industries LTD/M/s Rayalaseema Hi strength Hypo ltd?DCM Shriram ltd oer equivalent make approved by E-in-C's Br. Note : The contractor shall deliver the same as per the site requirement and direction of Engineer-in-charge.
Supply and mix calcium Hypo Chloride granular in factory sealed HDPE container ( 45 kg Each) decomposing at 177C, Mol Wt:142.98, Toxicity : Oral rat LD : 850 mg/kg having chlorination concentration level 70 %Make- Puri chlor (Sree Rayalaseema Hi- strength Hypo Ltd) of equivalent make as per approved by engineer-in-Charge (E-in-C's branch approved only)
Transporting air compressor and other allied equipment/ material to and from the site of T/well, installationo of machinery and dismantling there of.
M& L for Re-development of tubewell with air compressor of adequate capacity (not less than 250 cfm) as per specification till the availibility of sand free clear water, subject to minimum of 40 hrs of operation of air compressor.
M& L for Stablization and yield testing of tubewell by using Submersible pump of adequate capacity as per specification (subjected to minimum of 8 hrs of development with Submersible pump ) including conduction of sounding test (50000 for 8 Hrs).
Dismantling and and takingout Submersiable pumpset complete from well.
M& L for Lowering of Pumset complete with column pipe into well after completion of all operation and wrks including replacemnt of nuts, bolts, washers and gasket of suitable size.
M& L for Repair, servicing and comprehensive/ preventive maintenance of Engine part of DG set any make of Capacities 40KVA to 63 KVA, which include removal unserviceable worn out spare parts, cleaning of all components with necessary cleaning material, replacement of all spare parts and gaskets as per manufacturer spare part kit, engine oil change including overhauling, re-assembling of complete engine setting, timing setting, bleaching and engine testing, replacement of diesel filter,Engine oil filter, lubricating oil, rubber hose pipe, V belt, oil pipe, diesel pipe, repair kit, burnt oil part etc. and tightening of nuts bolts, washers greasing etc for proper running of DG sets all as directed at site complete. Note (i) Spares part, engine oil, fillters shall be measured and paid for separately as supply only . (ii) Cost of oiling, greasing, tightening of nuts, bolts and minor work etc are included in the unit rate quoted by the contractor.
Material & labour for replacement of Engine oil 20 W 40 during servicing of DG sets.
Supply only of Engine oil filter for DG set upto 63 KVA capacity.
Supply only of Diesel filter for DG set upto 63 KVA capacity.
Supply only of Air filter for DG set upto 63 KVA capacity.
Supply only of unserviceable fuel pipe for DG set upto 63 KVA capacity.
Supply only of asbestos rope any dia wrapped over the exhaust pipe complete
Repair and overhauling of self starter 12 V/ 24 V of DG set, upto 63 KVA Capacity, after opening nuts and bolts complete carrying out repair/ maint work for smooth functioning, testing complete and refixed same place as directed at site. Note :- (i) (Spare parts will be measured and paid separately as supply only)
Supply only of Field Coil to self starter 12V/24V of DG set upto 63 KVA complete.
Supply only of Armature winding to self starter 12V/24V of DG set upto 63 KVA complete.
Supply and fix in replacement of unsv Clutch assembly to self starter 12V/24V of DG set upto 63 KVA complete
Supply and fix in replacement of unsv Carbon Brushes to self starter 12V/24V of DG set upto 63 KVA complete
Supply only of Pinion Assembly to self starter 12V/24V of DG set upto 63 KVA complete
M&L for Repair and overhauling of dynamo of any DG set, upto 63 KVA capacity after opening nuts and bolts complete carrying out repair/ maint work for smooth functioning, testing complete and refixed same place as directed at site. Note :- (i) (Spare parts will be measured and paid separately as supply only ).
Supply only of Carbon Brushes to Dynmo of DG set upto 63 KVA complete
Armature rewinding to Dynmo of DG set upto 63 KVA complete
Supply only ofField Coil to Dynmo of DG set upto 63 KVA complete
M& L for Disconnecting and dismantalling the alternator unit of DG Set from the base plate of the DG set and transporting the workshop for repair, dismantaling the unit , further seperation the armature from the startor carefully, cutting and taking out the burnt winding of the alternator carefully, cleanning the slot and duly applying the insulation and assembling the stampings inserting the positiion in the startor incl applying slot insulation and rewinding of the alternator startor winding with super enameled copper conductor of the same gauge and the same number of turns as that of existing one including replacement of carbon brushes tapping the winding and bring out the coil conncetion for production of three phase 415 V 50 HZ AC supply preheating the winding and applying insulating warnish and drying the winding in oven and assembling the unit and transporting back to insatallation and fix on base plate and coupling with the DG set and testing complte all as specified and directed of following capacities:
M& L for Repair/maintenance of DG set Manual/AMF LT Panel by cleaning of all carbonized / corroded parts, checking of wiring and battery charging system if any in the panel replacement of lugs, single core copper cable 2.5 /4 Sqmm etc as required and making the panel serviceable of any size / any make including replacement of voltmeter, ammeter, power factor meter, indicator frequency meter etc all as directed by Engineer-in-Charge Note :- (i) (Spare parts like Voltmeter, Ammeter,Power Factor meter, Indicator lamp, Frequency Meter and MCB/MCCB will be measured and paid separately as supply only ). (ii) Cost of Lugs, tightening of nuts, bolts replacement of wiring and other minor work etc are included in the unit rate quoted by the contractor.
Supply only of Voltmeter, range 0 to 500 V into LT Panel of DG set upto 63 KVA complete
Supply only of Ammeter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply only of Frequency meter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply only of Power Factor meter, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply only of Indicator Lamp RYB, as per existing type or model into LT Panel of DG set upto 63 KVA complete
Supply only of MCB SPN 6-32 Amps 10 KA 230 volts "C" series complete
Supply only of MCCB TP 63 Amps adjustable thermal and fixed magnetic ,16 KA, 415 volts complete in LT Panel of DG set upto 63 KVA complete
Supply only of MCCB TP 100 Amps ,adjustable thermal and fixed magnetic ,16 KA, 415 volts complete in LT Panel of DG set upto 63 KVA complete
Supply only of battery terminal bolt type suitable for 180 AH battery as directed by Engineer-in-Charge.
Supply only of battery lead of copper conductor 25 Sqmm single core fitted with lead terminal on one side and other side with brass or lead terminal ( length of wire not less than1.5 Mtrs) as per site required and connection as directed by Engineer-in-Charge
Supply only of battery 12 Volts.150 AH including filling of required capacity electrolyte and transportation complete all as directed by Engineer-in-Charge.
Supply only of battery 12 Volts.180 AH including filling of required capacity electrolyte and transportation complete all as directed by Engineer-in-Charge.
Supply only of electrolyte distiled water to battery complete all as directed by Engineer-in-Charge.
Taking out injection nozzle from DG set transportation to authorised service centre for repairing and replacement of necessary parts calibration and re-fixing to DG set and testing complete all as directed by Engineer-in-Charge.
Material and Labour for servicing and overhauling and repairing complete alternator greasing cleaning of all stator and rotor, re-varnishing the stator and rotor winding with superior quality of varnish including heating and baking the same. Re-assembling the complete alternator, fixing in position and testing on load for the DG Set upto 63 KVA capacity Note :-(i) Cost of greasing, varnish, tightening of nuts, bolts replacement of wiring and other minor work etc are included in the unit rate quoted by the contractor.
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts complete all as directed by Engineer-in-Charge.
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with reputing cap 36KA complete all as directed by Engineer-in-Charge.
S &F on load Change Over switch side handle operated 415 V 4 pole of capacity 160 amps complete all as directed by Engineer-in-Charge.
S &F on load Change Over switch side handle operated 415 V 4 pole of capacity 100 amps complete all as directed by Engineer-in-Charge.
S & L cable XLPE insulated screened PVC bedded galvanized steel striper wire armoured electric power cables heavy duty with standard aluminium conductor,1100 volts grade,cross sectional area 3.5 core 50 Sqmm complete all as specified & directed.Note : Excavation, returning and refilling will be measured and paid separately.
All as per ser No 107 but 35 Sqmm 3.5 core
All as per ser No 107 but 25 Sqmm 4 core
Supply & fixing of Sand cushioning to under ground cable laid in trenches for laying of LT UG cable 8 cm depth before laying the cable and 15 Cm after laying and punned down to depth of 10 cm as per MES SSR Part -I ( 2009) all as specfied and directed. Note : Thickness of sand cushion after punning down will be measured and paid.
Material and labour for laying of bricks locally available sub-class 'B' brick (old size) for cable protection cover laid flat and dry in trenches over the cable perpendicular to the directon of cable complete all as specified and directed.
Material and labour for Cement concrete 1:3:6 type C-2 using 40mm graded stone aggregate in foundations, filling and mass concrete complete all as specified and directed.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of char coal dust and comman salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in type strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr including testing complete on completion complete all as specified and directed.
All as per sl item No. 113 above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note for item No. 113 & 114 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM included the quoted rate. (ii) The GI wire/strip or protection pipe beyond the 7.5 RM shall be measured & paid separetely
S&F of 90 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 9900 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in- Charge . Make: HPL cat Part HPLLEDSL9060E or eqivalent in PS
S&F of 60 W LED Street Light luminaire confirmining including all necessary arrangement for fixing on Pole made up SITC of high quality integrated LED street light with a miniumum system lumen of 6600 Lm and system wattage not exceeding 90 W with nominal efficiency 110 lumen/Watt. CCT of 5700K with SDCM of <5 and CRI>70. The houing should be of non- Corrosive high -pressure die cast aluminum with heat resistant toughened clear glass to with stand extreme environments with PF>0.95. Life time of 50K Hrs @L70. The ingress protection should be minimum IP 66 with IK rating of 07. The luminaire should have 5 KV internal 10 KV external surge protection in the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india. LM 79 and LM80 reports need to be submitted from NABL/UL accredited lab to verify above parameters .side entry mounted for 40 mm and above OD pipe bracket etc incl taking down old unsv light fittings complete all as specified and directed by Engr in Charge .Make: HPL cat Part HPLLEDSL6060E or eqivalent in PS
S&F of 120W LED Flood Light luminaire made up of Matt black ptextured powder coated pressure Die Cast aluminum housing and frame with heat resistant toughened clear glass fixed with SS screw/ Ant dust exposed lens, sturdiness and embossed brand name/ logo name of manufacturer on fixture . The luminaire should have a minimum system lumen output of 14400 lumens and 120 Watts. The fixture shall have a CRI of minimum 70. The fixture shall be designed for a sysytem life of 50000 hours @ 70 % lumen maintenence , Ingress protection of IP 66 (lamp and gear compartment ) and Mechanical impact resistance ratinfg of IK>=07. The fixture driver should have an operating voltage range of 120-277V, surge protection of internal 4 KV amd external surge protection of 10 KV, PF.0.95, THD<10%. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of india .LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters including complete electrical connection with fixing arrangenment on pole or wall and taking down unsv light fittings complete all as specified and directed by Engr-in-Charge .
Prakash Trading Corporation (BID ID -3153174)
M/S KALSI ENGINEERS AND CONTRACTORS (BID ID -3149195)
somyaenterprises (BID ID -3148186)
Nitika electricals and engineers works (BID ID -3149192)
M/s Ranpat Dev Infrastructure pvt ltd (BID ID -3153324)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .