Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance 11TH FLOOR ECO CENTRE BUSINESS TOWER P NO 4 EM BLOCK SECTOR V KOLKATA 91 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | Admitted-Finance |
| 2 | Admitted-Finance 1ST FLOOR FLAT NO 103 SCHEME NO 51 234 AVANTIKA NAGAR INDORE INDORE MADHYA PRADESH 452006 | INDORE | MADHYA PRADESH | 452006 | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Technically not Qualified |
Tender Value
₹15.8 L
EMD Value
₹31,690
Closing Date
5 Jan 2023, 3:00 pmClosed
Executive Engineer
Executive Engineer Electrical, Works Organization, Hauz Khas, IIT Delhi, New Delhi- 110016
Comprehensive Annual Maintenance Contract for Package, Ductable and VRV/VRF Type ACs installed in various location at IIT Delhi.
2022_IIT_732197_1
IITD/WORKS (SP-4063)/2022
Open Tender
Miscellaneous Works
Works
365 days
Indian Institute of Technology Delhi
As per tender documents
11 documents required · 11 mandatory
₹0
₹31,690
18 Jan 2023
30 Dec 2022
6 Jan 2023
30 Dec 2022
5 Jan 2023
30 Dec 2022
Amount
Comprehensive maintenance of water-cooled package, ductable and VRV/VRF type air-conditioners includes the following work: - 1. Replacement of all kinds of defectives components parts and PCB cards etc. 2. Rewinding of motors with suitable enameled copper wire of suitable size (ISI Marked). 3. Providing and topping up the refrigerant gas in all types of air-conditioners with the complete refrigeration line and compressor, after leakage testing with nitrogen within 48 hrs. Failing which, a compensation amounting to Rs. 2000.00/day shall be lived on the firm and be deducted from the bill. As when required on site. 4. Replacement of defective Compressors installed in the package, ductable and VRV/VRF type air-conditioners from the respective manufactures of the compressors [Blue star, Kirloskar, Tecumsheh, Carrier, Votlas] Compressors shall be get replaced from the manufacture installed in the Air-conditioners including providing and changing the refrigerant gas in the water/air cooled package type air-conditioners, ductable type air-conditioners and VRV/VRF type air-conditioners with the complete refrigeration line and compressor after leakage testing with nitrogen within 48 Hrs of award of work or as and when required on site. 5. De-scaling of all type of condensers and cooling coil with fins of (3.0TR, 5.0TR, 7.5TR, 8.5TR, 11.0TR, 12.0TR, 16.0TR and 22.0TR) package and ductable type air-conditioners with chemical Sunshine including brushing and flushing with caustic soda etc. twice in a year. First time within seven days of award of work, next in six months after work or as required on site. [One job means 1 AC per six months] 6. Comprehensive maintenance of electrical panels including replacement of all kinds of defective component, retightening and cleaning with CTC/CRC or equivalent chemical (i) Contractor shall carry out Preventive maintenance of all electrical and electronic operating panels and starters of all the package and ductable type air-conditioning system and will replace the defective parts within 24 hrs. Secondly, preventive maintenance on time as per schedule and when required as per the following. A) Package type Air-Conditioning System. I) Block-III-311 to 318 (Air-Cooled)- 3nos x 16.00TR=48TR II) Block-VI LT-1 (Air-Cooled)- 2nos x 11.00TR=22TR III) Block-VI LT-2 (Air-Cooled)- 2nos x 11.00TR=22TR IV) NRF VI-114 to 121 (Air-Cooled)- 3nos x 11.00TR=33TR V) TX-115 (Air-Cooled)- 2nos x 5.50TR=11TR VI) III-119 (Air-Cooled)- 1no x 11.00TR=11TR VII) ETSC (Air-Cooled)- 1no x 16.00TR=16TR VIII) ETSC (Air-Cooled)- 2nos x 22.00TR=44TR IX) II-401 (Air-Cooled)- 2nos x 5.50TR=11TR X) II-402 (Air-Cooled)- 1no x 8.50TR=17TR XI) IRD Mezzanine Floor (Air-Cooled)- 2nos x 16.50TR=33TR XII) IRD Conference Hall I-Floor (Air-Cooled)- 2nos x 11.00TR=22TR XIII) CRF LAB Block-V LT-11 (Air-Cooled)- 3nos x 8.50TR=25.5TR B) Ductable Type Air-Conditioning System I) Block IV LT-2, 136 (Air-Cooled)- 1nos x 5.50TR=5.5TR II) TX-122 (Air-Cooled)- 2nos x 7.50TR=15TR III) T&P Unit (Air-Cooled)- 2nos x 5.50TR=11TR IV) KSBS Science (Air-Cooled)- 1no x 3.00TR=3TR (Air-Cooled)- 1no x 5.50TR=5.5TR (Air-Cooled)- 1no x 7.50TR=7.5TR (Air-Cooled)- 1no x 8.50TR=8.5TR V) MS-108 (Air-Cooled)- 2nos x 3.00TR=6TR VI) RCA Package type unit 7nos x 5.5TR=38.5TR VII) Vishwakarma Bhawan-(Air-Cooled) 4nos x 11TR=44TR VIII) Vishwakarma Bhawan-(Air-Cooled) 1no x 8.5TR=8.5TR IX) Vishwakarma Bhawan-(Air-Cooled) 4nos x 16TR=64TR X) Vishwakarma Bhawan-(Air-Cooled) 7nos x 16.5TR=115.5TR C] VRV/VRF type Air-Conditioning System I] Dean faculty- 1no x 12TR capacity=12TR II] Dean Planning-1no x 12TR capacity=12TR III] KSBS- 1no x 12TR capacity=12TR IV] Student Counselling office – 1 x 7.5HP = 7.5HP V] Gulmohar Guest House dining hall- 1no x 12TR capacity=12TR All their preventive maintenance will be carried out in the presence of AE/JE
G. D. Enterprises
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .