| 3 | L3₹19.3 L+₹91,940.61 (5.00%)Rejected-Finance 0 3 SHASTRI STREET FEROZEPUR CITY PB 152002 | FEROZEPUR CITY | FEROZEPUR | PUNJAB | 152002 | L3 | Rejected-Finance Not Lowest tenderer | |
| 4 | L4₹20.6 L+₹2.2 L (11.8%)Rejected-Finance | L4 | Rejected-Finance Not Lowest tenderer |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(E) Ferozepur cantt
GE(E) Ferozepur cantt
REPAIR/ MAINT OF LT OH / LT UG DISTRIBUTION SYSTEM, REPAIR/ REPLACEMENT OF SERVICE CONNECTION AND ALLIED WORKS FOR AOR OF BDE AND ARTY BDE UNDER GE (EAST ) FEROZEPUR CANTT
2023_MES_573017_1
8061/GE/E/FZR/22-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE(E) Ferozepur cantt
Please refer tender documents
8 documents required · 8 mandatory
₹500
Yes
GE(East) Ferozepur cantt
₹40,000
Yes
22 Feb 2023
4 Jan 2023
1 Feb 2023
4 Jan 2023
30 Jan 2023
18 Jan 2023
Amount
Excavation in trenches not exc 1.5 metre wide and not exc 1.5 metre deep for foundation of poles/stays/cable etc and getting out in soft /loose soil complete all as specified and directed.
All as per item No 1 above but depth exceeding 1.5m and n eexceeding 3.0m
Returning , filling in and including spreading, levelling watering and well ramming in layers each n.exc 25cm thick in soft/loose soils complete all as specified and directed.
Removing surplus soil to a distance not.exc 50 mtr and depositing where directed at a level not.exc 1.5 mtr above the starting point. complete all as specified and directed.
M& L for Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed. Note:-The punned down thickness shall be measured and paid
Supply and laying well burnt, sub class 'B' brick old size for cable protection compete all as specified and directed
M&L for cement concrete (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation of poles filling and mass concrete complete all as specified and directed.
M&L for cement concreted (1:3:6) type C-2 using 40 mm graded crushed stone aggregate in foundation of pole/ stay assembly/feeder pillar box/LT panel,etc, including necessary form work and fair finsh to exposed surfaces without using extra cement etc complete all as specified and directed.
M&L Cement concreted (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified and directed.
Dismantling & taking out old damaged PCC/Steel pole of any size and removing from site of work complete all as specified and directed.
Dismantling & taking out old damaged stay assembly complete with stay wire, loop type insulator, wornout clamps etc of any size and removing from site of work complete all as specified and directed.
Dismantling and taking down old wornt out ACSR conductor of any type and size complete all as specified and directed.
Dismantling & taking down old wornt out MS clamps/cross arms/channels complete with nuts & bolts etc complete all as specified and directed.
Dismantling and taking down old U/S insulators of any type and size complete all as specified and directed.
M&L Cross arms bracings, supported clamps and back plates, fabricated from structual steel sections, drilling holes for bolts, in any shape or size as indicated or directed and including necessary welding bending cold or hot inclusive of nuts, bolts, washers and applying/painted with two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed
Supply and fixing LT Pre-stressed concrete pole 9.0 metres long of cross section 102 mm x 172 mm at top and 102 mm x 279 mm at bottom class 10 complying with requirement of IS 1678-1978 including painting of poles with two coats of synthetic enamel paint over a coat of primer in black and white strips upto 1.5 mtr height from top of PCC complete all as specified and directed (Note:- Necessary earth work and PCC shall be measured and paid separately).
Supplying and fixing stay assembly comprising of galvanised stay bow 40 cm long, 14 mm dia complete with 20 mm dia stay rod of 215 cm long with threaded ends and GI nut, two numbers thimbles, MS clamps made out of 40 x 6mm flat iron including nuts, bolts & washers, 300 x 300 x 6 mm stay plate , including painting of exposed MS work with two coat of aluminium paint over a coat of red oxide primer complete all as specified and as shown in electrial plate No 1 of SSR Part-I.complete all as specified and directed . Note: Necessary earth work , loop type insulator and stay strand shall be measured and paid separately under appropriate item of schedule/BOQ.
S & F in replacement of galvanised stay strand 7/4 mm size complete all as specified and directed.
M&L Aluminium conductor, steel reinforced (ACSR) of different sizes including jointing and stritching for over head lines on LT poles including binding, jumpers, line taps etc complete all as specified and directed
S & F loop type insulator, porcelain, vitreous white brown of green of size 90mm x 140 mm and clearance of hole 25.5 mm complete all as specified and directed.
S & F pin type, porcelain, viterous, white brown or green insulator including mild steel spindle & nut, two galvanised iron washers, one galvanised iron nuts 100 mm height , 65 mm dia for 1100 volts complete all as specified and directed.
S & F shackle type porcelain viterous white brown or green insulator for working pressure 1100 V of 90 mm dia and 75 mm height etc incl galvanised mild steel straps made out of flat iron 31 mm incl 12 mm dia bolts, nuts, washers etc complete all as specified and directed
Stretching only of loosened existing ACSR conductor (Per Span consisting of any number and size of wire) any size, by opening the binding wire from insulator and re-fixining after streching with proper sag including strenghtening of ACSR conductor and re-binding the same on insulators and binding complete all as specified and directed . NOTE :- The unit rate includes attending the complaints of snapping of conductors as and when occured and as intimated .
S&F in replacement LT line poly proplain composite phase separators moulded type suitable for horizontal/vertical 2 lines LT overhead lines complete all as specified and directed
S&F in replacement LT line poly proplain composite phase separators moulded type suitable for horizontal/vertical 3 lines LT overhead lines complete all as specified and directed
S&F in replacement LT line poly proplain composite phase separators moulded type suitable for horizontal/vertical 4 lines LT overhead lines complete all as specified and directed
M&L for Pruning of tree branches of any size /dia from LT/HT overhead line up to a minimum clearance of 2.5 mtr from over head conductor including and required T &P and transportation for disposal complete all as specified and directed
M/L for Clearing of bushes/small plants upto root level around and surroundings areas E/M installations (i.e.Two Poles/ Four poles structure, outdoor-substation yards, pump house & E/M installations etc) including surface dressing n.exc 15 cm deep and removing debris to a distance n.exc 50m complete all as directed
M&L for painting to LT Panel complete with two coats of synthetic enamel paints over a coat of red oxide including preparation of old painted surface by scraping down etc and other necessary fabrication work like replacement of hinges ,locking Knobs, bending and welding work required for hinges etc as per required at site complete all as Specified and directed Note :- The cost of item rate includes removal of old unservicable MCCBs of any type and capacity New MCCBs,Voltmeter, Ammeter and Aluminium bus bar will be measured and paid separately under respective item of BOQ.
M&L for repair of Outdoor type LT Panel/Feeder pillar by relacement of Front & Rear doors/ shutters, made out of CRCA Sheet 3.15 mm thickness with necessary fabrication work like replacement of hinges, locking knob bending, welding and paining with two coats of synthetic enamel paints over a coat of red oxide primer to matching with existing panel color as required at site complete all as specified and directed
Supply & Fixing Aluminium Bus Bar of Suitable rating as per existing Item complete all as specified and directed
M&L for Supply and spreadinng graded coarse aggregate of nominal size 20mm in outdoor LT sub stns complete all as specified and directed.
M&L Painting of old LT PCC/ Steel tubular pole upto 1.5 mtr height from PCC, with two coats of synthetic enamel paint with black and white strips and including wiriting pole No including preparartion of old painted surface complete all as specified and directed
M&L Painting of steel tubular pole of any size with two coats aluminium paint over a cooat of red oxide primer including preparatin of old painted surface and including wiriting pole No complete all as specified and directed .
Taking down old faulty LT UG Cable of size 25 to 70 Sqmm 3.5 core complete all as specified and directed
Taking down old faulty LT UG Cable of size 95 to 240 Sqmm 3.5 core complete all as specified and directed
Taking down/Workout faulty LT UG Cable of size 300 to 400 Sqmm 3.5 core.complete all as specified and directed
Supplying, laying and connecting XLPE insulated and sheathed armoured 1100 volts grade heavy duty electric cable with multistranded aluminium conductor laid in trenches/duct' through pipe, in floor , along the poles including aluminium thimble or aluminium line tape of size 25 sq mm 3.5 core nominal cross section area complete all as specified and directed. ( Note:- Excavation, earth work, sand cushioning , GI pipe & protection clamps shall be measured and paid separately.)
All as per item No 38 above but size 35sq mm 3.5 core
All as per item No 38 above but size 50 sq mm 3.5 core
All as per item No 38 above but size 70 sq mm 3.5 core
All as per item No 38 above but size 95 sq mm 3.5 core
All as per item No 38 above but size 120 sq mm 3.5 core
All as per item No 38 above but size 150 sq mm 3.5 core
All as per item No 38 above but size 185 sq mm 3.5 core
All as per item No 38 above but size 240 sq mm 3.5 core
All as per item No 38 above but size 300 sq mm 3.5 core
All as per item No 38 above but size 400 sq mm 3.5 core
Supplying, laying and connecting XLPE insulated and sheathed armoured 1100 volts grade heavy duty electric cable with multistranded aluminium conductor laid in trenches/duct, through pipe, in floor , on poles including aluminium thimble or aluminium line tape of size 10 sq mm 2 core nominal cross section area including disconnecting and taking out old/burnt out service cable complete all as specified and directed. ( Note:- Excavation, earth work, sand cushioning , GI pipe & protection clamps shall be measured and paid separately.)
All as per item No 49 above but size 16 sq mm 2 core
All as per item No 49 above but size 10 sq mm 4 core
All as per item No 49 above but size 16 sq mm 4 core
S&F in replacement of MCCB adjustable thermal and adjustable magnetic setting with overload short circuit and earth fault protection of capacity, 400 Amps, 4 Pole ICS=100% ICU , 36 KA with overload variation 80-100% complete all as specified and directed .
S&F in replacement of MCCB adjustable thermal and adjustable magnetic setting with overload short circuit and earth fault protection of capacity, 250 Amps, 4 Pole ICS=100% ICU ,36 KA with overload variation 80-100% complete all as specified and directed. Make - ABB,SIEMENS & SCHNEIDER as approved by GE
S&F in replacement of MCCB adjustable thermal and adjustable magnetic setting with overload short circuit and earth fault protection of capacity, 200 Amps, 4 Pole ICS=100% ICU , 36 KA with overload variation 80-100% complete all as specified and directed .
S&F in replacement of MCCB adjustable thermal and adjustable magnetic setting with overload short circuit and earth fault protection of capacity, 160 Amps, 4 Pole ICS=100% ICU , 25 KA with overload variation 80-100% complete all as specified and directed.
Supply and laying GI pipe "light grade " 100mm bore for cable protection including taking out old/broken/rusty pipe complete all as specified and directed
All as per item No 57 above but size 80 mm bore complete all as specified and directed
All as per item No 57 above but size 50 mm bore complete all as specified and directed
All as per item No 57 above but size 40 mm bore complete all as specified and directed
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated with aluminium solid conductor served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire,one twin core cable flat or circular of size 10 sq mm complete all as specified and directed
All as per item No 61 above but size 16 sq mm complete all as specified and directed
M&L for pinpointing of 1.1 KV underground LT cable fault of any size with help of cable fault locating machine (CFL Machine) consisting of DC Testing,Thumping system and DIGI point Sensor complete to locate the exact fault location (1'st fault) all as specified.
VK ENTERPRISES
Marwaha Builders
M/S Sandhu Const.Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .