Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹1.4 L+₹10,270 (8.06%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹1.4 L+₹10,370 (8.14%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹1.5 L+₹20,160 (15.8%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹1.7 L+₹44,840 (35.2%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹2.3 L
Closing Date
13 Dec 2021, 9:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive_Engineer
EE, EandM, Division, APWD, Prothrapur, Port Blair
Construction of 03 Nos Science Lab D/S for Govt Senior Secondary School Havelock SW Providing IEI of 01 No Lab
2021_APWD_4441_1
NIT No. 59/EE/EandM/21-22 2nd Call
Open Tender
Electrical Works
Item Rate
30 days
South Andaman
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
31 Dec 2021
1 Dec 2021
13 Dec 2021
1 Dec 2021
13 Dec 2021
6 Dec 2021
2 Dec 2021 - 4 Dec 2021
75 days
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required a) Group-C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required (For Light Plugs to be used in non residential Building)
Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Supplying and fixing brass batten/ angle holder including connection etc. as required
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) a) 4 way (4 + 12), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single Pole
Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) 40 A
Supplying of 18W LED Tube Light Fitting T5 RETRIFIT TUBELIGHT equivalent to C&S Cat No. TARIKA / 18W, LT4F18WLEDT5/WD with LED Lamp or its equivalent etc., as required.
Supplying of 9W LED Lamp equivalent to Crompton Cat No. LLP0101051 AELIUS LXD LED LAMP 9W BC 6500K or its equivalent etc., as required.
Supplying of AC Ceiling Fan (1200 mm) Sweep without regulator Similar to make Crompton Empower (ISI Marked) or its equivalent etc., as required.
Supplying of 900 mm sweep Ceiling Fans Similar to Usha Non Decorative Ceiling Fan Model Swift or its equivalent etc., as required.
Supplying and Fixing of Street Light Fitting 25W Similar to Make - Polycab, Model PCGLS T1 25W, 5700K and suitable GI Pipe or its equivalent etc., as required.
Supplying of 15W Surface LED down light Fitting similar to Make Bajaj Sleek Model BGSLO SLEEK SURFACE 15W WH SQ or its equivalent etc., as required.
M/s G K Construction
NAVJEEVAN ENTERPRISES
M/s Sai Electrical Works
C. KUMAR
DILIP RAJ
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .