| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.9 L+₹4.8 L (23.6%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹25.9 L+₹5.7 L (28.3%)Rejected-Finance 0 MANPUR CHITBARAGAON CHITBARAGAON BALLIA UTTAR PRADESH 221713 | BALLIA | UTTAR PRADESH | 221713 | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹27.1 L+₹6.9 L (34.2%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 5 | L5₹29.7 L+₹9.6 L (47.4%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 May 2023, 6:00 pmClosed
GE 881 EWS C/o 56 APO
GE 881 EWS C/o 56 APO
REPAIR TO FENCING, GATES, WALLS, DRAIN, PROTECTIVE WORKS AND MISC WORKS AT SURANKOTE IN THE AOR OF STN HQ KG AND REPAIR/ REPLACEMENT TO E/M INTERNAL FITTINGS/ FIXTURES AND WIRING IN VARIOUS UNITS AT BG, HAMIRPUR, JWG AND MENDHAR IN THE AOR OF STN HQ
2023_MES_590947_2
GE/PNH-18/2023-24
Open Tender
Civil Works
Item Rate
270 days
GE 881 EWS C/o 56 APO
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE 881 EWS
₹90,000
Yes
24 Jul 2023
25 Apr 2023
23 May 2023
25 Apr 2023
16 May 2023
10 May 2023
Amount
B&R PORTION:- Dismantling posts or struts (wood, steel or RCC) any section, including taking out embedded portion and making good disturbed ground posts embedded in concrete complete all as specified and directed.
Taking down carefully old galvanised stranded steel barbed wire from old RCC posts and removing from site complete all as specified and directed.
Demolition of reinforced concrete in ground floors and pavings not exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Demolition of cement concrete (un reinforced) in ground floors and paving n exc. 15 cm. thickness, below or above ground level complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry built in cement mortar including all quoins arches pillars etc, complete all as specified and directed.
Dismantling mild steel work of any description complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (40mm graded aggts) as in foundation and mass concrete where required as per direction of Engineer-in- charge complete all as specified and directed.
M&L for MS work for fencing post and struts made from angle iron and flat iron in any section including cutting tops to shape , drilling holes and notching for fixing of wires etc confirming to Fe -290 or Fe -330, complete all as specified and directed.
S & F galvanised 2 strand, steel barbed wire, 2.20mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, includdigng, securing or tying at crossings with and provisiion of galavnised (Zink coating 60 gsm) mild steel wire, staples or steel pins, etc as directed each line wire to measured complete all as specified and directed.
Supply only chain link MS zink coated 60gm/sqm as per IS 4826 fencing of any mesh size and 3mm dia of wire complete all as specified and directed. NOTE: This item shall be measured and paid as per actual weight or standard weight as per SSR which ever is less.
Fixing only chain link fencing including line wire, any mesh size and any type of standards rails straining bolt etc including provision of binding wire complete all as specified and directed.
S&F mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M & L for TMT bars 6mm to 8 mm dia and cut to length bent to shape and binding with MS wire (annealed) not less than 0.9mm Dia complete all as specified and directed.
S&F mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,length of bolt 5 to 10 cm long and dia of neck not exc 15 mm complete all as specified and directed.
S&F concertina coil made to shape as dia exc 450 mm but n exc 600 mm put on top of wall in between Y shaped angle iron post and secured with necessary binding wire complete all as specified and directed by Engr in charge.
M&L for brick work with sub class ‘B’ bricks, straight or curved on plan exc. 6 m mean radius, built in cement mortar 1:6, complete all as specified and directed.
M & L for Walling of random rubble, brought upto course, built in CM 1:6 complete all as specified and directed.
All as per item No. 18 above but except stone complete all as specified and directed.
M&L for boulder filling hand packed tightly (any thickness) at back of walls over arches etc, and raising (or lowering) to the required level compete all as specified and directed.
M&L for rendering 20 mm thick in cement mortar 1: 4 on other than fair faces of brick work or stone masonary surfaces, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for rendering 15 mm thick in cement mortar 1: 4 on fair faces of brick work or concrete surfaces, chajja and suspended work finished even and smooth without using extra cement, complete all as specified and directed.
M&L for raking out joint/pointing to random rubble or polygonal rubble stone masonry uncoursed or brought upto courses built in CM complete all as specified and directed.
M& L for raised pointing in cement mortar (1:4) brought upto courses built in CM complete all as specified and directed.
M&L for applying two coats of cement base paint over alkali resistant priming coat on walls including preparation of new plastered or un-plastered surfaces of wall complete all as specified and directed.
M&L for applying one coat of cement base paint on walls including preparation of old plastered or un-plastered surfaces of wall complete all as specified and directed.
M&L for applying two coats of cement base paint on walls including preparation of un-plastered surfaces of wall complete all as specified and directed.
S&F framed work such as grills, gratings, steel gate , purlin etc., with ends of bars shouldered and/or riv-eted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 gde E-165 complete all as specified and directed.
M&L for preparation of new untreated surfaces of steel any description over 10 cms width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified and directed.
M&L for providing precast cement concrete 1:3:6, type C-1 (using 20 mm graded crushed stone agg) as in PCC bonders set in CM 1:6 complete all as specified and directed.
M&L for reinforced cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc. complete all as specified and directed.
S&F in repair Reinforced concrete pipes, class NP2, laid and jointed complete with collars complete all as specified and directed.
M&L for 100mm thick PCC 1:2:4 type B1 (using 20 mm graded stone aggregate) as in floor/hardstanding and finishing the cement concrete surface complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in sub base and flooring complete all as specified and directed.
M & L for plain cement concrete 1:2:4 type B-2, using 40mm graded crushed stone aggregates as in surfaces channels and drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner grith in cement concrete, using extra cement including forms, moulds mitred/stopped ends etc. complete all as specified and directed.
M&L for chequered cement concrete tiles with chemical resistant coating if size 300x300x 25mm thick, set & jointed in neat cement slurry in floors and pointed with grey cement mixed with pigments, laid over and including 20mm thick screed bed in CM 1:6, complete all as specified and directed.
M&L for PCC 1:2:4 Type B1(using 20mm graded agg) in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
M&L for 75mm thick PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) as in sub base to chequered/interlocking tiles complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS-15658-2006 of 80mm thickness M-40 Grade,laid jointed pointed with grey cement and no pigments, complete all as specified and directed by Engr-in-Charge. Note: The sample shall be got approved by GE before bulk procurement & lot shall be got tested independently by the GE.
M&L for sand filing under floor incl spreading and levelling in layers not exc 25 cm thick complete all as specified and directed.
S&F in repair PVC (SWR) pipes 110 mm dia of bore single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
E&M PORTION:- Taking down carefully copper/ aluminium unserviceable/ perished point wiring (light, fan, socket or power complete including fixture and fittings such as switches, ceiling roses, pandents, regulators, sockets, light fittings,removing material from site for taking credit etc and making good disturbed surfaces of wall, floors, complete all as specifiecd and directed.
M&L for point wiring with two single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable and one single core 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including PVC casing & caping (ISI marked) of suitable size with PVC boards of appropriate sizes and all requisite accessories such as PVC elbow, Tee, collars, bends etc. with PVC terminals box & cover for mounting swtches, sockets, fan regulator etc for mounting switches, sockets, fan regulators etc complete all as specified and as directed for the following :-
One light/fan point controlled by one way switch 6 Amp complete all as specified and directed.
One ligh point controlled by two, two way switch 6 Amp complete all as specified and directed.
One 3/5 pin socket outlet 6 amp on same board complete all as specified and directed.
One 3/5 pin socket outlet 6 amp independent board complete all as specified and directed.
One bell point controlled by one way switch 6 Amp complete all as specified and directed.
All as per srl item No 45 here in before but for one 3 pin socket outlet 16/20 Amp independent with two single core 2.5 Sqmm size cable as phase & neutral and one single core 2.5 Sqmm as in continuous earth wire complete all as specified and directed.
S&F in repair ceiling rose, 3 terminal, surface bakelite 65 mm x 50mm, PVC/poly carbonate, insulated body, complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp single pole one way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano flush type 6 Amp two way, (ISI marked), complete all as specified and directed.
S&F in repair switch piano bell push flush type 5 Amp single pole one way (ISI marked) complete all as specified and directed.
S&F in repair socket outlet 2 in 1, 3 pin, 5 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket multipurpose combination 2 in 1, 5 pin, 6 Amp flush type universal, complete all as specified and directed.
S&F in repair Switch socket outlet multipurpose combination 2 in 1, 6 pin, 5 and 15 Amp flush type universal, complete all as specified and directed.
S&F in repair Lamp holder PVC/Polycarbonate type with back plate suitable for batten fittings, complete all as specified and directed.
S&F in repair stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. for 1200 / 1400mm sweep, complete all as specified and directed.
S&F in repair electric bell ding dong type 230 volts AC supply 50 Hz complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repair LED lights fitting 1x 20W, 220V, (power factor not less than 0.9) AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
Supply and fixing in repair inverter LED batten 1x 20W, with square profile and polycarbonate channel, lithium iron battery with charging time of 8 to 10 hours and backup tile upto 04 hours with driver, holder incl LED tube light connecting up with with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed. Make : Havells cat part No. LHEXACP7FN1W020 or equivalent make as specified in PS
Supply and fixing in repair inverter LED bulb 9 watt including all connected items, complete all as specified and directed. Make : Havells cat part No. LED 9 W INVERTER BULB B22 CDL or equivalent make as specified in PS
S & F in repair surface mounted square/round type decorative LED light fittings 18 watt connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S & F in repair surface/wall mounted LED light fittings, 2 feet long with 10 W LED ready to use complete all as specified and directed.
Supply and fixing in repair LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F in repair gate light fittings, outdoor type, high power , 20 watt, IP65 luminaire, prewired with suitable pole for mounting complete all as specified and directed. Make: Havells cat part No. Coral Opal IP65 or equivalent make as mentioned in PS
Supply and fixing in repair LED building security light fitting 30 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
S&F in repair LED driver suitable for 34 watt LED ceiiling light fittings and making connection to fitting complete all as specified and directed. Make:-Havells cat part No-LEDDRIVER36V36WS or Equivalent cat part of make as specified in Appx 'A' to P.S.
S&F in repair single pole and neutral enclosure with a two pin and metal earth plug and socket complete with & incl one single pole MCB of 20 Amps complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, TPN double door (IP43), 4 ways built in bus bars suitable for 415 volts, AC, 50 Hz and suitable for FP MCCB as incommer and out going SP/TP MCBs complete all as specified and directed. Note:- MCBs shall be measured and paid separately.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 4 ways built in bus bars suitable for 240 volts, AC, 50 Hz , including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 8 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair sheet metal enclosure for DBs, SPN double door (IP43), 12 ways with 200 amps rated bus bar suitable for 240 volts, AC, 50 Hz, including connecting both incoming and outgoing cable termination with proper taping, lagging testing and commissioning complete all as specified and directed.
S&F in repair MCB TPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCTNF040 - DHMGCTNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB SPN 40-63 amps 415 volts 10 KA 'C' series, complete all as specified and directed. Make:-Havells cat part No- DHMGCSNF040 - DHMGCSNF063 or Equivalent cat part of make as specified in P.S.
S&F in repair MCB single pole 6 to 32 amps 240 volts 10 KA 'C' series complete all as specified and directed. Make:-Havells cat part No-DHMGCSPF006-032 or Equivalent cat part of make as specified in P.S.
Taking out old unsv exhaust fan from site and replacement of exhaust fan made up of sturdy engineering plastic complete with louvers shutter, voltage 230 V, 50 Hz, 1200 RPM, copper winding of sweep 300mm incl all connecting accessories complete all as specified and directed by Engineer-in-charge.
S&F in repair of PVC counduit non matalic rigid, of size 25 mm dia (external) incl all accessories use for fixing of conduit on wall and ceiling etc, complete all as specified and directed.
S&F in repair PVC casing caping of size 25 mm incl all fixing accessories complete all as specified and directed.
S&F in repair flexible PVC conduit of approved quality of size 25 mm incl all fixing accessories complete all as specified and directed.
S&F Earthing complete with galvanized steel earth plate electrode 60cmx 60cmx6mm thick buried directly in ground (earth pit not less than 2.25m deep below normal ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to galvanized iron wire 4.0mm dia by means of bolts, nuts and washers of galvanized iron or steel, protected by GI light grade pipe 15mm bore including GI light grade water pipe 20mm dia with funnel all as shown in electric plate No. 3 of 2009 SSR Pt-I and testing complete including earth work in any type of soil, PCC 1:2:4 type B-1 as in earthing pit and cover 50mm thick reinforced with 6mm dia MS round bar @ 10cm C/C both way and MS frame, common salt, charcoal and testing on completion including dismantling unsv earthing, complete all as specified and directed.
S&F in repair Sub main wiring with single core cable 2x 6 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 6 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 6 Sqmm and one run of pvc conduit/casing caping shall be measured as one unit.
S&F in repair Sub main wiring with single core cable 2x 4 Sqmm FRLS insulated unsheathed stranded copper conductor cable 1100 Volts grade including surface PVC casing caping medium grade alongwith 1x 4 Sqmm FRLS insulated unsheathed copper conductor cable as earth wire connected with main earth dolly, complete all as specified and directed. Note:-Three wire of 4 sqmm and one run of PVC conduit/casing caping shall be measured as one unit.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat or circular of size 6 Sqmm 2 core & including taking down old old unsv service cable connection, complete all as specified and directed.
S&F 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor served with PVC tape and over all PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia GI suspension wire, one twin core cable flat of circular of size 10 Sqmm 2 core including taking down existing old service connection, complete all as specified and directed.
Repair and maintenance of unserviceable ceiling fan of 1200mm/1400mm sweep at contractor's work shop, incl dismantling complete the ceiling fan parts, inspecting serviceability of all the parts, refixing of serviceable parts after cleaning and replacement of unserviceable parts with company's genuine parts i.e. capacitor, bearing, bushes, shaft, bracket, rubber bush, connecting wire, PVC connector, aluminium clamp for rod, bracket, bush rod, greasing/oiling etc assembling, cleaning and testing of ceiling fan complete all as specified and directed. Note: (i) Unserviceable parts as above shall be measured and paid separately under relevant items of Sch 'A' item No 84 to 92 as supply only. (ii) Rewinding of stator will be measured & paid for separately under relevant item of Sch 'A'. (iii) Cost of minor part i.e. Cotter pin, screws shall be deemed to included in the cost of quoted rate.
Supply only bearing good quality for ceiling fan 1200mm/1400mm sweep ISI marked complete all as specified and directed.
Supply only Gun metal bush for ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Supply only capacitor 2.5 mfd ISI marked complete all as specified and directed.
Supply only brass bracket assy for hanging the ceiling fan 1200mm/1400mm sweep complete all as specified and directed.
Supply only 3 core flexible wire 40/.0076, white colour from ceiling rose to fan connector complete all as specified and directed.
Supply only stator shaft for ceiling fan complete all as specified and directed.
Supply only fan blade for ceiling fan 1200 mm sweep of existing make complete all as specified and directed.
Supply only fan blade for ceiling fan 1400 mm sweep of existing make complete all as specified and directed.
Supply only canopy (top/bottom) of ceiling fans any make /size of colour matching with existing canopy/ fan colour complete all as specified and directed.
M&L for removing of old burnt winding of any size , type and rewinding of stator winding with superior quality copper wire with insulation complete all as specified and directed.
M&L for painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler, one coat after cleaning all dust etc complete all as specified and directed.
M&L for Replacement of down rod of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.45 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality complete all as specified and directed by Engineer in charge.
All as per item No 52 above but of length 0.60 Mtr complete all as specified and directed.
Repair and maintenance of unserviceable exhaust fan of any cap and sweep by dismantling the exhaust fan parts, inspecting the serviceability of parts, refixing of serviceable parts after cleaning, replacement of unerviceable parts i.e. beaing, bush, capacitor, connecting wires, fan blade, locknut, rubber pad etc, oiling/greasing, cleaning and testing of exhaust fan complete all as specified and directed. Note: (i) Unserviceable parts replaced shall be measured and paid separately under relevant items of Sch 'A' item No 98, 99 & 102 as supply only. (ii) Rewinding of stator winding shall be measured & paid for separately under relevant item of Sch 'A'. (iii) Cost of minor part i.e. screws shall be deemed to included in the cost of quoted rate.
Supply only double ball bearing (ISI marked) for exhaust fan of 200 mm sweep to 450 mm sweep fan complete all as specified and directed.
Supply only gun metal bush for Exhaust fan of any capacity. complete all as specified and directed.
M&L for rewinding of 450mm sweep exhaust fan motor with superior quality copper winding wire with insulation complete all as specified and directed.
M&L for rewinding of 300mm sweep exhaust fan motor with superior quality copper winding wire with insulation complete all as specified and directed.
Supply only blade of exhuast fan of 200 mm sweep to 450 mm sweep as per existing make complete all as specified and directed.
M&L for preparation of painted surfaces of exhaust fan of any make and size by scrubbing old and applying one coat of synthetic enamel paint by spray painting complete all as specified and directed by Engr-in-Charge.
M&L for Disconnecting electric & water connection to geyser of capacity 25/35/50 litr, taking down from existing position, dismantling and inspecting all the parts for its serviciability, cleaning of serviceable parts i.e. base assembly, connecting lead, thermostat, electric contact, electric wiring, indicators, safety valves etc re-fixing in the same in position, testing complete all as specified and directed by Engr-in-Charge. Note: (i) Unserviceable parts replaced shall be measured and paid separately under relevant items of Sch 'A' item No 105 to 116 as supply only. Notes: (i) The defective parts to be replaced shall be measured and paid separately under relevant item of Sch 'A' as supply only (ii) Cost of minor items i.e. screws, nuts, bolts etc shall be deemed to be included in this item
Supply only heating element of capacity 2 KW, ISI marked suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only heating element of capacity 1.5 KW, ISI marked suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only thermostat, ISI marked suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only indicator lamp suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only geyser safety valve suitable for existing size, type & make of geyser complete all as specified and as directed.
Supply only PVC pipe connection of heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature complete all as specified and as directed.
Supply only aluminium/chromium type flecxible connection, heavy duty for inlet, outlet connection suitable to withstand the pressure and temperature complete all as specified and as directed.
Supply only inner tank made out of steel sheet conforming to IS, suitable for 25 litres capacity of geyser, vertical type complete all as specified and as directed.
Supply only inner tank made out of steel sheet conforming to IS, suitable for 35/50 litres capacity of geyser, vertical type complete all as specified and as directed.
Supply only non return valve made out of brass fixed in vertical position of suitable dia complete all as specified and as directed.
Supply only new base assembly with inlet and outlet pipe made out of steel sheet with gasket and proper size of nuts, bolts and washer etc suitable for 25 litres capacity of geyser complete all as specified and as directed.
Supply only new base assembly with inlet and outlet pipe made out of steel sheet with gasket and proper size of nuts, bolts and washer etc suitable for 35/50 litres capacity of geyser complete all as specified and as directed.
M/S PARSHOTAM KUMAR GUPTA
NATIONAL TRADING COMPANY
M/S Farooq Ahmed Bhat
HUSSAIN ENTERPRISES
VIKAS ENTERPRISES
M/S BADRI NATH GUPTA
M/S KHAN ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .