Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.6 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.9 L+₹23,063.20 (1.17%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹22.8 L+₹3.2 L (16.1%)Rejected-AOC 306 SHIV BARI MARG PANCHVATI NAGAR BATHINDA 151001 PB | BATHINDA | BATHINDA | PUNJAB | 151001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹24.2 L+₹4.5 L (23.1%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹24.6 L
EMD Value
₹49,220
Closing Date
8 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE AF Bhisiana
HQ CWE AF Bhisiana
CWE(BHI)/BHI-56/2022-23
2023_MES_580089_1
CWE(BHI)/BHI-56/2022-23
Open Tender
Civil Works
Item Rate
180 days
AF STN BHISIANA
AS PER COVER 1
6 documents required · 6 mandatory
₹500
Yes
GE AF Bhisiana
₹49,220
Yes
17 Mar 2023
9 Feb 2023
10 Mar 2023
9 Feb 2023
8 Mar 2023
24 Feb 2023
9 Feb 2023 - 16 Feb 2023
Amount
Supply, install , testing and commissioning of Eco feriendly 25 KVA disel engine driven generating set with acoustic enclosure made out of CRCA sheet powder coated . Specially designed lifting arrangement/hooks, meet the latest CPCB, norms of 75 dBA @ 1 mtr distance and as per the testing guide line of CPCB. DG set shall be confirming to IS 10001/10002 and alternator as per : IS 13364 water cooled type self starting system with 24V DC supply , 3 phase 4 wire AC 415 Volt +5% at 1500 RPM, 50 HZ, 0.8 PF self exciled, self regulated, automatic voltage regulation, class H insulation type alternator. With AMF panel for automatic automatic starting at mains failure installed with the following accessories. Eco friendly for emmission and noise diesel engine confirming to BS/IS standard water cooled complete under NTP condition with a provision for 10% over load for one hour on 12 hours running with he following : Engine : * 3 Cyllinder ,In-line 4 Stroke,radiator cooled engine * Well designed air handling system with dry type ,replaceable paper element air cleaner with restriction indicator,Air to Air after cooling for 25 KVA ,Optimised turbocharger for increased attitude capabilites. * Best in class fuel economy with Inline fuel pump with A1 class mechanical governing ,spin on fuel filter * Standard intergral set mounted radiator system,designed and testedfor 50 Deg cel ambient temprature * Full flow spin on lube oil filter,first fill of lube oil and coolant,Electrical starter motor with soft start engagement feature,Battery charging altenator 1X12 V DC battery required AH Alternator : * Brushless type,screen procted,Revolving field ,self excited alternator conforming to IS/IEC 60034-1 * Dedicated winding specially designed for 3Phase operation,better motor starting capability,best in class efficiency,compact design with sealed bearing for longer life and lesser maintenance. * Impregnation on all wound component for better mechanical strength.
Supply, installation, testing and commissioning of transformer outdoor type oil natural air natural (ONAN) cooled, oil immersed copper wound step down complete with first fitting of IS 1180 ISI marked filtered and dehydrated transformer oil and other standard fittings/accesssories as per particular specifications and seven position off circuit tap changer (tapping range +5% to -10% in steps of 2.5% each)with vector group Dyn-11 with HV and LV cable boxes with cable glands as per cable sizes, as persite requirement , HT 11 KV 3 phase 4 wire 50 HZ as per level- III of IS 1180:2014of capacity 25 KVA, 11/0.433V complete all as specified. Note : (i) Pre dispatch inspection of transformer shall be carried out by rep of Accepting officer at manufacturer premises with in overall cost quoted by the contractor . Nothing extra shall be payable on this account at later stage (ii) After installation of the transformer the same shall also be tested by IEM / SEI and all the equipment /instrument shall be arranged by the contractor for testing. The cost of the same shall also be included in the item rate. (iii) Supply, installation, testing and commissioning of transformer outdoor type oil natural air natural (ONAN) cooled, oil immersed copper wound step down complete with first fitting of IS 1180 ISI marked filtered and dehydrated transformer oil and other standard fittings/accesssories as per particular specifications and seven position off circuit tap changer (tapping range +5% to -10% in steps of 2.5% each)with vector group Dyn-11 with HV and LV cable boxes with cable glands as per cable sizes, as persite requirement , HT 11 KV 3 phase 4 wire 50 HZ as per level- III of IS 1180:2014of capacity 25 KVA, 11/0.433V complete all as specified. (iv) Plinth of required size and design as per manufacturer shall be in the part of this job including earth work.
Supply, laying & testing cable XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with standard alluminium conductor 11000 volts grade of size 3 core 95 sqmm, complete all as specified and directed.
Supplying and laying synthetic rubber insulated mats 2 mm thick for voltage upto 3.3KV for electric purpose as per IS15652-2006,(superseding IS 5424) suitable for electric shock safety of size 2X1m, complete all as specified and directed.
Supplying and laying synthetic rubber insulated mats 2.5mm thick for voltage upto 11 KV for electric purpose as per IS15652-2006,(superseding IS 5424) suitable for electric shock safety of size 2X1m, complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, complete all as specified and directed.
M & L for Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
Supply installalation commissioning and testing of outdoor HT Feeder pillar box of size 1200X1200X1000mm and 3.15 mm thick CRCA Sheet weather and vermin proof CPRI approved with copper bus bar 800 Amps supported on 6 Nos HT bus bar insulator suitable for 12kv, HT cable 11KV 3 core of size upto 185 sqmm including provision of cable entries with glands locking arrangements and angle iron frame and legs of 90 cm long using 60x60x6 mm size MS angle iron fixed in plinth complete with construction of Plinth of size 2500X2500X1000mm floor in PCC 1:4:8 type D2 base including neccessary excavation earth work, complete all as specified and directed.
M&L for Chain link fencing including straining and fixing to steel posts and straning bolts in PCC 1:4:8 type D2 base of appropriate size including neccessary excavation earth work, complete all as specified and directed.
Supply, Install , testing and commissioning of LT panel of suitable size for 3 Phase 415 Volts outdoor type made out 3.15 mm thick CRCA sheet of sides of the panel board and 200 amps rated Alumunium bus bar, insulated with PVC sleaves and coloured with (red, yellow,blue and black) CTR and internal wiring with suitable size of PVC insulated copper wire , use with angle iron 50x50x6 mm frame bottom of the panel board , grouted by using PCC foundation 1 : 2 : 4 type C1 with 20 mm graded stone aggregate , thimbling and cable entry boxes with cable gland incl powder coated complete with following (Main panel) :- (a) MCCB 4 pole 63 amps 25KA,adustable type - 01 No incoming (b) MCCB 4 pole 40 amps 30 KA,adjustable type - 03 Nos (outgoing) (c) Multifunction meter 3PH, size 96x96 sqmm digital type (d) LED Indicator lamp RYB (3 Nos) - 01 Set
Excavation in trenches soft and loose soil not exc. 1.5 m wide and not exceeding 1.5m depth for foundation of poles/laying of cables/stay/strut etc not exceeding 10 Sqm on plan and getting out in soft/loose soil, complete all as specified and directed.
Returning, filling including spreading, leveling watering and well ramming in layers not exceeding 25 cm, complete all as specified and directed.
Removing excavated material (soil) n.exc 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point, complete all as specified and directed.
Material and labour for providing sand as in sand cushioning to under ground cable including punning down of sand in layers, complete all as specified and directed.
Material and labour for cable protection cover of UG LT cable by old size bricks common burnt clay building bricks sub class `B’ laid dry and flat abutting each other with width equal to length of brick and gap between adjacent brick not exceeding 10mm, complete all as specified and directed.
Material and labour XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 70 sqmm 4 core, complete all as specified and directed.
Material and labour XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 35 sqmm 4 core, complete all as specified and directed.
Material and labour for PCC cable protection cover, class HV, Type 1, flat, of size 300mm x l80mm x 40mm for HT UG cable and gap between adjacent cover not exceeding 10mm , complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including GI strip of size 32x6mm upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc, complete all as specified and directed.
Material and labour for earthing complete with galvanized steel earth plate electrode 600x600x6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level,the earth electrode surrounded by adequate quantity of charcoal dust and salt to a packed thickness of 15cm on all side and including connected to and including GI strip of size 25 x 4 mm upto 7.5 mtrs long by means of nuts and bolts, check nuts and washers of GI and connected to earhing test point and earth dolly all as shown in electrical plate No 3 of MES SSR part I and testing on completion including necessary excavation and earth work in any type of soil,PCC(1:3:6)type C1 chamber,pre-cast RCC slab 50mm thic in cement concrete (1:2:4),type B1,reinforced with welded steel wire fabric or XPM,(weight not less than 4 Kg per Sqm) with cast iron frame,funnel with watering pipe 20mm dia medium grade,wire mesh and lugs,GI protection pipe,15mm dia,light grade,7.5 mtr long for protection of earth lead upto test point etc, complete all as specified and directed.
Supply and fixing of cable route indicator made out of cast iron and embedded HT cable and size of the cable on the plate of size 80 mm dia 5 mm thick and grouting lugg of suitable size including in PCC foundation of suitable size, complete all as specified and as directed.
Supply and fixing of GI tubing 100mm light grade galavanised with all fitting complete for cable protection under road crossing/on pole/wall or similar position, complete all as specified and directed.
Material and labour for making bore below the road for crossing the GI pipe medium grade for cable protection and fill the putty on both sides of the GI pipe after crossing the armoured cable to avoid the water inside, complete all as specified and directed.
Aman Enterprises
M/s Luxmi Constructions
REYANSH GARG AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .