GE Minniebay
GE Minniebay Junglighat Post Minniebay Port Blair 744103
PROVN OF CHAIN LINK FENCING AND SECURITY LIGHT AND GUARD ROOM AT MAIN GATE IN MARCOS UNDER GE MINNIEBAY PORT BLAIR
2023_MES_617537_2
8286/E8
Open Tender
Civil Works
Item Rate
180 days
Minniebay Port Blair
As per tender documents
10 documents required · 10 mandatory
₹500
GE Minniebay
₹97,000
Yes
9 Dec 2023
25 Sept 2023
25 Oct 2023
26 Sept 2023
23 Oct 2023
10 Oct 2023
Amount
Surfaces excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m depth for foundation, etc., and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
Material and labour for Plain Cement Concrete Type D2 1:4:8 Nominal mix (using 40 mm graded stone aggregate) in foundations, filling and mass concrete.
M & L for hardcore of gauge not exceeding 63 mm of broken granite stone, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all as specified and directed by Engineer-in-Charge.
Removing Excavated soils not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-30 Design mix using 20 mm graded stone aggregate as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-30 Design mix using 20 mm graded stone aggregate as in Columns, pillars, piers, posts and struts including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-30 Design mix using 20 mm graded stone aggregate as in Beams, cantilevers, bressummers, lintels over 1.5m span including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete M-30 Design mix using 20 mm graded stone aggregate as in slabs supported on walls, beams and columns in floors, roof landings, balconies, shelves,chajjas and the like including formwork complete all as specified and directed by Engineer-in-Charge.
M&L CRS Fe-550D grade TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L CRS Fe-550D grade TMT bars 6 mm to 8 mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed by Engineer-in-Charge.
M&L for pre-cast cement concrete block masonry with solid blocks,Type C1,1:3:6 (20mm graded aggregate) exc 10 cm in width and setting in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick plain Cement Concrete Type C2,1:3:6 Nominal mix (using 40 mm graded stone aggregate) in plinth protection laid in panels with contraction joint complete all as specified and directed by Engineer-in-Charge.
M&L for non Skid ceramic tiles 7 to 8 mm thick(square/ rectagular) area of each tile exceeding 0.11 sq m but not exceeding 0.18 sqm , in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm screed in cement mortor 1:6 complete all as specified and as directed by Engineer in Charge.
M&L for glazed ceramic,coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match over 10mm thick rendering in Cm 1:4 wall complete all as specified and as directed by Engineer in Charge
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet, used instead of Plain colour PVC sheet & edges will be printed to match with printed sheet, reinforced with MS square tube & fixing in opening complete all as specified and directed by Engineer-in-Charge.
S&F for Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded wood grain printed (Rudhraksh) PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and wood grain printed colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of wood grain printed colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with 5mm thick x15mm wide PVC sheet beading used inside stiles and rails and decorative PVC beading of 10mm x 10mm (900)and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing
S&F 100 mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised type C-21 complete all as specified and directed by Engineer-in-Charge.
S&F Aluminium anodised barrel tower bolts of extruded sections 150 mm size complete all as specified and directed by Engineer-in-Charge.
S & F 150 mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed by Engineer-in-Charge.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
M & L for rendering 5mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 on concrete or block masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge. Note: Water proofing compound will be measured and paid separately
M&L for rendering 5mm thick on concrete surfaces ( roof ceiling and soffit of chajjas), in CM (1:3) finished even & smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Supply only Integral water proofing compound.
M&L for preparation of newly plastered surfaces of walls and applying two coats of oil bound distemper over a coat of chalk whiting on plastered surfaces, complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of newly plastered surfaces of ceiling and applying two coats of cement based paint over a coat of chalk whiting on plastered surfaces complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of new surfaces and providing necessary scaffolding & safety precautions and cleaning the surfaces free from any loose paint, dust,greases,growth of fungus,algae or moss using wire brush and levelling the surface even and smooth using mechanical sander and finally applying water by pressure jet washer of max pressure of 170 bar with automatic pressure relief system. The following process shall be initiated only after the above surface preparations :- (a) Filling the surface cracks using crack seal compound on required consistency using electric mixer. (b) Filling the dents and holes using wall care putty in appropriate ratio using electric mixer.(c) Applying one or two coats of damp proof primer (primer coat) using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.(d) Applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm Anti algal weather coat 100% acrylic smooth emulsion paint using Airless spray technology with max working pressure of 22.8 Mpa/3300 psi and capable of operating single spray gun with a max material hose length of 30m.
Note : (i) Work shall be executed only through authorised applicator duly approved by Manufacturer of Paint and certificate in this connection shall be submitted by the Contractor. (ii) The affected area of the wall due to dampness shall be ascertained by moisture meter of power input 9v Display 60 LEDs using colour code scale and Moisture measurement of each location shall be submitted along with RAR. (iii) The contractor shall upload MOU letter with any one of Paint manufacturer within 28 days of receipt of acceptance copy failing which contract shall be liable for cancellation. Authorised applicator shall have valid authorisation letter from the manufacturer The authorisation letter needs to be valid for the complete period of execution of the painting work. (iv) After preparation of the surface, Engr-in-Charge shall inspect and approve the same before applying primer and finishing coats. (v) The equipments to be used in the work shall be certified by the manufacturer with whom the MOU been entered into.The specification and details of the equipments and tools pertaining to this item is denoted on Particular Specification.Manual method of paint application is not allowed and also Penalty shall be levied if appropriate tools & equipments pertaining to smart periodicals not used. (vi) Proper masking arrangement shall be carried before the application of primer or paint. (vii) The other coat of Primer and Paint shall be applied only after the completion of drying time and comply with recoating period as per manufacturer instructions.
S&Ffor 75 mm PVC (SWR) Nahani trap, with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F for 100 mm PVC (SWR) floor trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed by Engineer-in-Charge.
S&F for 125X100mm PVC (SWR) gully traps,square or round mouthed,type complete all as specified and directed by Engineer-in-Charge.
S&F for 100mm bore PVC (SWR) bend including adhesive complete all as specified and directed by Engineer-in-Charge.
S&F for 75mm bore PVC (SWR) bend including adhesive complete all as specified and directed by Engineer-in-Charge.
S&F for vitreous china squatting pan"Orissa pattern" size 580 mm x 440 mm white with integral foot rest etc. ( excluding cistern and flush pipe) including S or P trap, CI socket & provision of concrete bedding and making good to floor all as specified & directed by Engineer-in-charge.
S & F 10 Liters capacity,ISI marked PVC Valve less, Syphonic action type, low level flushing cistern, white, with inlet ball valve, float, handle, flush pipe of polyethylene of low or high density of PVC, 32mm dia including brackets and connections to pipe complete all as specified and as directed by Engr-in-Charge.
S&F for vitreous china wash hand basin, white flat back size 550x400 mm including brackets ,32mm dia waste coupling, brass chromium plated, 32mm dia PVC waste pipe etc with long screwed shanks and fly nuts, complete all as specified and directed by Engineer-in-Charge.
S&F for 15mm bore pillar tap, cast copper alloy, with capstain head, chromium plated,screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts, fancy type, screwed for iron pipe, complete all as specified and directed by Engineer-in-Charge.
S&F PVC connections 15mm size with PTMT nuts of length 600mm complete all as specified and directed by Engineer-in-Charge.
S&F for Bib taps 15mm bore cast copper alloy chromium plated with crutch or butterfly handles,fancy type, screwed down, screwed for iron pipes complete all as specified and directed by Engineer-in-Charge.
S&F for Stop Valves, 15mm dia, cast copper alloy with capstan head, Chromium Plated, Fancy Type, screwed down high pressure with crutch or butterfly handle with long shank and cup [concealed type] for iron pipe etc complete all as specified and directed by Engineer-in-Charge.
S&F for brass chromium plated shower rose with 150mm long CP shower arm 125mm size revolving type suitable for 15 mm bore pipes complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 20 mm outer dia CPVC pipes SDR 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
Supplying and laying of 25mm outer dia CPVC pipes SDR 11 fittings on walls / ceiling or laying in floors complete all as specified and directed by Engineer-in-Charge.
S&F for CPVC Brass elbow suitable for 20mm outer dia CPVC pipes complete all as specified and directed by Engineer-in-Charge.
S&F for CPVC Brass Tee suitable for 20mm outer dia CPVC pipes complete all as specified and directed by Engineer-in-Charge.
S&F for CPVC tank adaptor suitable for 25mm outer dia CPVC pipes complete all as specified and directed by Engineer-in-Charge.
S&F for CPVC union suitable for 25mm outer dia CPVC pipes complete all as specified and directed by Engineer-in-Charge.
S&F for CPVC ball valve suitable for 25mm outer dia CPVC pipes complete all as specified and directed by Engineer-in-Charge.
S&F for Anodised aluminium frame (minimum anodisation is 50 microns) for doors, windows ventilators with one or more rebates including joining cleat for fixing etc
S & F in repairs Aluminium anodised (minimum anodisation is 50 microns) Door / window / Ventilator/partition frames and shutters (02 Nos glazed & gauzed), side hung type, without sash bars, standard aluminium grills, necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, handles, locking arrangements etc., complete with standard aluminium sections, complete all as specified and as directed (Note for 51 to 52:- Weight of various Aluminium sections handles and locking arrangements shall only be considered for measurement for payment. However cost of rubber packing given in the item shall be deemed to be included in the rate quoted (NOTE :- Glass panels, prelaminated particle boards, glass & aluminium wire cloth as applicable will be measured and paid separately as supplied only).
Supply only Aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples complete all as specified and directed by Engineer-in-Charge.
Supply only 5.5mm thick sheet glass ordinary quality, in squares n. exc 0.5sqm each pane complete all as specified and directed by Engineer-in-Charge.
Supply only 12mm thick Prelaminated particle board, interior grade, prelaminated both sides with decorative choice laminations, fixed with screws to aluminium frame work complete all as specified and directed by Engineer-in-Charge.
Material and labour for APP modified waterproofing treatment over existing RCC roof slab with following specification including brushing off the surface to receive the treatment obtain the required surface and then providing 10mm screed bed with water proofing compound with required slope complete as directed :- Note : Rendering and WPC shall be measured and paid separately under relevant item of this schedule (a) Applying bituminous primer @ 1.2 kg/Sqm on the prepared dry roof surface. (b) Laying 4mm thick APP membrane Plain finish weight not less than 3 to 4 kg per sqm by torch application with minimum 10cm side lap and 15cm end lap and membrane shall be taken to the parapet through a fillet and shall be tucked inside up to height of 300mm.(c) Applying bituminous primer @ 1.2 kg/Sqm and applying 20 mm thick hydraulically pressed cement tiles over screed of cement plaster 1:3 with water proofing compound jointed and pointed. [Note : The laying of membrane shall be got done through an authorized applicator of manufacturer of APP membrane].
S&F for framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed by Engineer-in-Charge.
S&F Mild steel work in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc Fe 410-W (Gde- E- 250) quality- A complete all as specified and directed by Engineer-in-Charge.
M&L for preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of zinc yellow metal primer complete all as specified and as directed by Engr-in-Charge.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and directed by Engineer-in-Charge.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm thick Cement concrete type D2, 1:4:8 Nominal mix (using 40 mm graded stone aggregate) in sub base of flooring/ hard standing.even & smoth without using extra cement incl formwork complete all as specified and directed by Engineer-in-Charge.
M&L for Chequered cement concrete tiles 25mm thick with grey cement and pigments, set, jointed and pointed in neat cement slurry in floors over 15mm thick cement screed in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
surface dressing n.exc 15 cm deep in soft/loose soil complete all as all as specified and as directed
Excavating over areas, n exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge.
All as per item No. 65.00 exc 1.5 m but n exc 3m in depth complete all as specified and directed by Engineer-in-Charge.
M&L for Reinforced cement concrete Design mix) type B-1, 1:2:4 using 20 mm graded aggregate in Beams, cantilevers, bressummers, lintels over 1.5m span incl formwork complete all as specified and directed by Engineer-in-Charge.
M&L for reinforced cement concrete (Design mix) type B-1, 1:2:4 using 20 mm graded aggregate in slabs supported on walls, beams and columns in floors, roof landings, balconies, shelves,chajjas and the like including formwork complete all as specified and directed by Engineer-in-Charge.
M&L for loose filling with aggregates of gauge 40 to 80 mm in soakage pits, soakage wells complete all as specified and directed by Engineer-in-Charge.
M&L for 150 mm dia PVC (SWR) drain pipes laid in trenches and joints including adhesives/ rubber solvent solution complete all as specified and directed by Engineer-in-Charge.
M&L fof PCC 1:3:6 Nominal mix type C-2 as in Concrete bed to drain 150mm bore pipes including packing under, and hunching against the sides of pipes after they are laid and tested; complete all as specified and directed by Engineer-in-Charge.
M&L for precast RCC 1:2:4 type B-1(using 20mm graded stone aggregate) as in cover slab including necessary reinforcement complete all as specified and directed by Engineer-in-Charge. Note: Mild steel bars of any dia required for cover slab shall deemed to be included in this quoted rate.
S&F for Cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles complete all as specified and directed by Engineer-in-Charge.
S&F for 110 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
S&F for 110 mm dia PVC(SWR) bend any radius complete all as specified and directed by Engineer-in-Charge.
S&F for 110mm dia PVC(SWR) vent cowl complete all as specified and directed by Engineer-in-Charge.
M & L for RCC M-30 Design Mix, using 20mm graded stone aggregate as in Walls, retaining walls, basement walls, ballast walls and the like, any thickness above top of footings including attached pilasters and buttresses etc incl formwork complete all as specified and directed by Engineer-in-Charge.
S&F for 75 mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by Engineer-in-Charge.
M&L for stone boulder filling as in weep holes complete all as specified and directed by Engineer-in-Charge.
M&L for back filling of retaining walls using approved earth obtained from excavation in the subject work complete all as specified and directed by Engineer-in-Charge.
Exavation in post holes in hard/ dence soil not exc. 0.5 cum and removing surplus soil to a distance not exc 50 mtr and making good the surface.
M&L for mild steel framed work such as posts , railing and fancing work and similar work to conforming to Fe-290 Gde E-165 complete all as specified and directed by Engineer-in-Charge.
S&F in repair PVC coated chain link MS galvnized fencing mess of size 50x50mm , having 3mm dia wire with minimum 1mm thick PVC coating [5mm overall dia] complete fixed to any type of standards, rails, straining bolts , etc complete all as specified and directed by Engineer-in-Charge. Note : The supply only of MS flat iron, Rod & MS bolts shall be measured and paid under relevent items of this schedule.
S&F for Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc complete all as specified and directed by Engineer-in-Charge. Note : Each line of wire shall be measured and paid accordingly in this item.
Supply only MS bars 10mm dia for support to chain link fencing complete all as specified and directed by Engineer-in-Charge.
Supply only flat iron as in fillets fort securing wiremess including necessary drilling holes for bolts and welding confirming to Fe-310-0 complete all as specified and directed by Engineer-in-Charge.
Supply only screw bolts 10mm dia machine made hexagonal or square head at one end screwed the other or screwed both ends to be fitted with washers & one hexagonal or square not exc 150mm long complete all as specified and directed by Engineer-in-Charge.
Surface excavation n exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in hard / dense soil complete all as specified and directed by Engineer-in-Charge.
M&L in repair for stainless steel of grade SS-304 ,mirror polished square ,rectangular or circular pipe of different size of security gate, balusters and railing,chain or letters of any height etc , including stainless steel arc welding and bright finishing by polishing with grinding etc,complete all as specified and directed by Engineer-in-Charge.
S&F Precast PCC concrete poles of 9 meter long having 152 mm x 152 mm at top and 152 mm x 260 mm at bottom including necessary Earth work,PCC foundation coping etc including two coats of aluminium paint with one coat of primer along with yellow and black strips of relevant size as instructed in IS code complete all as specified and as directed by Engineer-in -charge.
Supply and fixing energy efficient LED street light fitting of 70 watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficacy more than 100 lumens/watt individual LED'S should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for driver and fitting including making electrical connection along with bracket all as specified and directed by Engineer-in-Charge. Make : Havells Cat part No. ENDURAOMNIPLUSSL70WLED757SASYTOPC
Supply and laying PVC LT UG Cable 1100 Volt grade heavy duty with XLPE insulated aluminium conductor served with an inner sheathening of PVC tape armoured with galvanised steel wire or tape and over all PVC Sheathed stranded conductor of size 16 Sqmm 4 Core complete all as specified and directed by Engineer-in-Charge. Note :- (i) Excavation, earth work, sand cushioning, brick protection, cutting of road and pipe shall be measured & paid separately under appropriate item of this Schedule.
M&L for Sub main wiring complete with 2 runs of 2.5 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm PVC casing caping in surface/PVC conduit/steel conduit on surface (as required) along walls roofs etc including 2.5 sqmmm size pvc insulated unsheathed copper earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note: (i) All three wire/cable (phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run/four runs of cable and one run/two runs of earth conductor and PVC Conduit/Casing Caping be measured as one length.
Supply, Install, Test and Commissioning of LT feeder pillar box outdoor type fabricated out of 3.0 mm thick CRCA sheet double door, CPRI approved complete with powder coating with seven tank process mounted on M.S angle Iron frame of size 40x40x6mm, duly grouted with PCC reqd with the following:-(a) S & F copper bus bar 300 Amp with cloured heat shrinkable insulated sleeve 415 Volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm- 01 Set.(b) S&F MCCB FP 200 Amps 25 KA - 01 No
Supply and fixing LT cable junction box,IP 65 rated dust and water proof made out of PVC non- metallic sheet FRP type, factory made, size of box 250x200x100mm deep with swiveling cover and locking clamp, consisting of aluminium bus bar strip 150mm x 30mm x 3mm, 4 Nos mounted on PVC insulator and provision of incoming/outgoing cables with grommets, including in built 6Amp MCB, SP, 9/10KA one No complete all as specified and as directed by Engineer-in-charge.
Material and labour for mild steel work made out of MS flat like clamps ,bolts and nuts etc and connected items including painting with 2 coats of aluminium paint after a coat of primer complete all as directed by Engineer-in-Charge.
Material and labour of of Plain Cement Concrete (1:4:8) type D-2 Nominal mix using 40mm graded stone aggregate as in foundation of electric poles /structs etc including necessary form work complete all as directed by Engineer-in-Charge.
Material and labour of Plain Cement Concrete (1:3:6) type C-1 using 20mm graded stone aggregate as including coping including necessary form work and fair finish to exposed surfaces without using extra cement complete all as directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate of size 60cm x 60cm x 0.63 mm thick buried directly in ground. Vertically total depth not less than 2.25 mtr below normal ground level with top edge of earth plate at depth of not less than 1.5 mtr below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 32 x 6mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 32 x 6mm) including GI protection pipe 40mm light grade dia for protection of stip upto test point all as directed GI pipe medium grade 20mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, all as provided at least 50cm away from the earth pit and not just on earth pit including testing on completion.
Supply and lay And testing,commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100Volts grade, with stranded aluminium conductor of size 50 Sqmm x 3.5 Core,Suitable gland ,crimping ,lugging ,Before and after laying of cable insulation test report to be submitted to Engineer-in-Charge.
All as per item No.100 above but capacity of 25 sqmm x 3.5 core complete all as directed by Engineer-in-Charge.
Supply and fixing GI pipe light grade 40 mm bore for cable protection fixing to poles with clamps/along wall/floor/under road/across the drain or nallah including clamps nuts etc all as specified and directed by Engineer-in-Charge.
Excavation in hard / dense soil Including road/PQC cutting etc not exceeding 1.5m wide and n exc 1.5m depth and getting out including forming of bottom for laying cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 50 mm and inner dia 38 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engineer-in-Charge.
Supply, laying of Telerex DWC (double Wall corrugated) HDPE pipe ISI marked of outer dia of 90 mm and inner dia 75 mm polethylene including couplers, bends, cap etc., with smooth internal and profiled external surface for non pressure under ground cable complete all as specified and directed by Engineer-in-Charge.
Material and labour for earthing complete with galvanized iron of street or earth plate of size 60cm x 60cm x 0.63 mm thick buried directly in ground. Vertically total depth not less than 2.25m below normal ground level with top edge of earth plate at depth of not less than 1.5m below ground level surounded from all sides with alternate layers of charcoal and common salt and connected to GI earth strip 25 x 4mm thick by means of GI bolts, nuts washers & check nuts and soldering the strip, electrode connected to panel board or on poles or on transformer (including making of test point with GI strip of size 25 x 4mm) including GI protection pipe 40mm light grade dia for protection of stip upto test point all as directed GI pipe medium grade 20mm bore for watering including providing funnel and wire mesh CI frame and 10 cm thick suitably reinforced RCC pit cover PCC chamber pit with PCC 1:3:6 type C2 using 40mm graded stone aggregates complete including excavation and earth work, all as provided at least 50cm away from the earth pit and not just on earth pit including testing on completion.
Supply and fixing energy efficient LED Flood light fitting of 200 watt epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficacy more than 100 lumens/watt individual LED'S should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided with inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for driver and fitting including making electrical connection all as specified and directed by Engineer-in-Charge. Note: The cost of assembling the unit shall deemed to be included in this quoted rate.
M & L point wiring with 1.5 Sq.mm (nominal area) PVC sheathed multi strandard copper conductor pvc insulated 1100 volt FRLSH grade single core cable drawn through concealed and including rigid steel enamelled conduit medium grade ISI marked minimum 25 mm size and its accessories complete along with 1.5 Sqmm PVC sheathed multi strandard copper conductor pvc insulated 1100 volt FRLSH single core cable but in green colour as continuous earthing wire and connecting to common earth dolly completely concealed ,ceiling/roofs with and including 1.2 mm thick MS sheet terminal boxes duly fabricated flush mounting in the wall for mounting switches,switch socket combinations fan regulators etc., as required with 3 mm thick plastic laminated sheet top cover all as directed and specified for the following.
(a) One light /fan point controlled by one switch
(b) One 3/5 pin socket outlet 5 Amps on the same board with other switches
(c) One 3/5 pin socket outlet 5 Amps on Independent board
All as per item No.109 here in before but with 2.5 Sqmm single core PVC sheathed multi strandard copper conductor pvc insulated 1100 volt FRLSH cable for one three pin socket 15 Amps socket on independent board including continuous earth wire PVC insulated 2.5 Sqmm PVC sheathed multi strandard copper conductor PVC insulated 1100 volt FRLSH cable to common earth dolly all as specified and directed by Engineer-in-Charge.
S&F switch piano, flush button type, single pole, one way 5 amps all as specified and directed by Engineer-in-Charge.
S&F socket outlet 2-in-1, 3 pin, 5 amps flush type all as specified and directed by Engineer-in-Charge.
S&F of switch socket combination 2 in 1, 5amps flush type all as specified and directed by Engineer-in-Charge.
S&F of Switch socket combination 3 pin 16amps, flush type all as specified and directed by Engineer-in-Charge.
S&F ceiling rose, surface bakelite 65 mm x 30 mm, 3 terminals all as specified and directed by Engineer-in-Charge.
S&F Electronic dimmer type (movable) regulator 230 volt all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring complete with 2 x 1.5 sqmm, single core, multi stranded copper conductor FRLSH PVC insulated and sheathed cable 1100 volts grade, drawn in 25mm PVC casing caping in surface/PVC conduit on surface (as required) along walls roofs etc including 1.5 sqmm size single core, multi stranded copper conductor FRLSH PVC insulated earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engineer-in-Charge. Note: (i) All three wire/cable (phase, neutral and earth) should be run through for each individual circuit from the DBs. (ii) Two run/four runs of cable and one run/two runs of earth conductor and PVC Conduit/Casing Caping be measured as one unit length.
S&F in replacement DB SPN 8 way with category of protection double door type IP-42 factory made with tinned copper 200 Amps rated bus bar suitable for MCBs,all as specified and directed by Engineer-in-Charge. Note : SPN distribution board shall be fixed in the wall such that front cover shall be seen flush with the wall surface
Supply and fixing 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 to 32 AMP, complete with connection testing and commissioning all as specified and directed by Engineer-in-Charge.
Supply and fixing 240V, 10 KA 'C' curve miniature circuit breaker (MCB) of SPN and current carrying capacity 32amps, complete with connection testing and commissioning all as specified and directed by Engineer-in-Charge.
Supply & Fix 1200mm sweep ceiling fan 5 star rated, BLDC, 240 volt , Opal . White/brown including rod minimum length 1.5 m and bush , nut bolts , capacitors including drilling on roof and fixed 1 to 1.5 feet rod and connecting bolts etc complete all as specified and as directed by Engr-in-Charge. Make : Havells model No Effciencia Neo or equivilant makes mentioned in list of makes
Supply & Fix Exhaust fan , 300mm Sweep 240 volt , 1400RPM,Opal . White/brown including making hole suitable size for fixing 300 mm sweep exhaust fan making good distribution and after fixing exhaust fan flap cover tobe fixing on behind exhut fan hole , nut bolts , capacitors including all acessories all as specified and directed by Engineer-in-Charge.
Supply & Fix wall mounting fan , 450mm Sweep 240 volt, Single Phase IP 65 protection with die cast alluminum hosing, jerk free oscillation & smooth running comprising of high performance high speed motor for higher air delivery incl provision of three core flexible PVC cable with stranded copper conductor size 1.5 sqmm connecting up to the ceiling rose including all accessories, metalic conduit all as specified and directed by Engineer-in-Charge.
S & F LED tube light fitting, 1x20w, 230v .Surface and wall mounted LED batten, elegant dia cast aluminium batten for designer homes bright LED source with uniform light out put , 2400 lm , surge protection of 2 KV with wide voltage protection 160-360 V in provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver. & connecting up with twin core twisted flexible copper conductor cable with suitable size all as specified and directed by Engineer-in-Charge.
Supply and fix Security light fitting LED type,20watts 240 Volts luminous shall be more than 2000 lumen, efficiency not less than 100 lm/Watt , and accessories complete mounted on 25 mm dia light grade GI pipe bracket 1.0m long bent to shape, mounted on wall,connection complete all as specified and directed by Engineer-in-Charge.
Supply and fix LED light fitting 1x9w /1X10w bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size, all as specified and directed by Engineer-in-Charge.
Supply and fix ultra slim elegance LED lighting fixture with extruded aluminium heat sink, integrated electronic driver, 10 watts 5700K (2ft) energy efficient and environment friendly, all as specified and directed by Engineer-in-Charge.
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size all as specified and directed by Engineer-in-Charge.
Supply and lay And testing,commissioning of LT UG cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) 1100Volts grade, with stranded aluminium conductor of size 25 Sqmm x 2 Core,Suitable gland ,crimping ,lugging ,Before and after laying of cable insulation test report to be submitted to Engineer-in-Charge.
M/s Pooja Enterprises
BISAKHA PLUMBING WORKS
Usha Builders
bansal construction
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .