Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC GC ROAD ABDUL LATIF ROAD PO TITAGARH KOLKATA 700119 | 24 PARAGANAS NORTH | WEST BENGAL | 700119 | L1 | Accepted-AOC lowest bidder | |
| 2 | L2₹26.6 L+₹5.0 L (23.1%)Rejected-Finance 6A BANAMALI GHOSHAL LANE KOLKATA 700034 | KOLKATA | WEST BENGAL | 700034 | L2 | Rejected-Finance HIGHER BIDDER | |
| 3 | L3₹26.9 L+₹5.3 L (24.6%)Rejected-Finance 38 BAGUIATI ROAD KOLKATA 700059 | 24 PARAGANAS NORTH | WEST BENGAL | 700059 | L3 | Rejected-Finance HIGHER BIDDER | |
| 4 | L4₹42.5 L+₹20.9 L (96.4%)Rejected-Finance ABANI APARTMENT 1ST FLOOR 6 2 TALBAGAN ROAD WEST PO NONACHANDANPUKUR BARRACKPORE KOLKATA 700 122 | KOLKATA | 24 PARAGANAS NORTH | WEST BENGAL | 700122 | L4 | Rejected-Finance HIGHER BIDDER | |
| 5 | Rejected-Technical BMC 1 54 GANTI NETAJI PALLY PO GANGANAGAR KOLKATA 700 132 INDIA | 24 PARAGANAS NORTH | WEST BENGAL | 700132 | - | Rejected-Technical REJECTED DUE TO NOT BELONG TO APPROPRIATE CATEGORY |
Tender Value
₹19.5 L
EMD Value
₹39,000
Closing Date
1 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
VIVEK TANENIA
GARRISON ENGINEER (CENTRAL) KOLKATA T37 NAPIER ROAD HASTING KOLKATA 700022
REPAIR MAINT OF EXTERNAL ELECTRIC SUPPLY AND EXTERNAL WATER SUPPLY WORKS AT AIRFORCE CAMP BALLYGUNGE AND REPAIR REPLACEMENT OF INTERNAL FITTINGS FIXTURES BLDG SAFETY DEVICES GEYSERS FN REPAIRS AND CONNECTED ITEMS AT AF CAMP UNDER GE (CENTRAL) KOLKATA
2023_MES_621521_1
8636/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
KOLKATA
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (C) KOLKATA
₹39,000
Yes
18 Mar 2024
4 Oct 2023
2 Nov 2023
4 Oct 2023
1 Nov 2023
20 Oct 2023
4 Oct 2023 - 19 Oct 2023
Amount
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc and getting out in soft/loose soil for laying of water supply pipe line /under ground cable complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 Cm as in soft/loose soil complete all as specified and directed.
Removing excavated material ( soils of any type) not exc. 50 m and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
Supply and laying dry coarse sand as in cushioning of under ground electric cable in trenches, laid to a uniform thickness of 23 Cm (15 Cm under the cable & 8 Cm over the cable) and gently punned down to 18 Cm thickness complete all as specified and as directed by the Engr-in-Charge. Note:- Thickness after punning down shall be measured for payment.
Supply and laying in trenches Bricks, sub class 'B' over burnt (kiln burnt) old size bricks, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
Laying only in trenches Old serviceable bricks obtained from taking out old unserviceable XLPE cable, laid flat dry with width of the bricks laid to the axis of the cable for protection of cable complete all as specified and as directed by the Engr-in-Charge.
M&L Cutting existing road / path etc for taking out cable and protection pipe and making good the disturbed surfaces with cement concrete type C2 ( 1:3:6, using 40mm graded crushed stone aggregates) of suitable depth complete all specified and as directed by Engineer-in-Charge.
M&L Plain Cement Concrete 1:3:6 (40 mm graded crushed stone aggregate) type C2 including necessary form-work, etc., complete all as specified and as directed.
M&L Plain Cement Concrete type D2 (1:4:8), (using 40mm graded crushed stone aggregates) as bases of poles and similar locations including taking down old unserviceable PCC complete all as specified and as directed.
M&L Plain Cement Concrete (1:2:4) type B-1 using 20mm graded stone aggregate as in coping of pole/struts and other similar location etc with and including all necessary form work including demolition of old PCC/broken PCC complete all as specified & directed.
Taking out unserviceable UG cables of any type and any sizes from trenches etc and removing from the site of work complete all as specified and directed. Note:- (i) Serviceable bricks obtained shall be stacked properly for re-use. (ii) Excavation and earth work shall be measured and paid separately under relevant item of these schedule.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 95 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as directed by the Engr-in-Charge.
Supply and laying XLPE insulated PVC sheathed, armoured, aluminium conductor cable 1100 Volt grade 185 Sqmm 3.5 core in trenches/ duct/floor/wall with provision of saddle and lugs, joints etc including connection complete all as specified and directed by the Engr-in-Charge.
Supply and laying in trenches or fixing on wall or passing through pipe,conecting and testing, 11000 volts grade, heavy duty electric cable with XLPE insulated,screened, galvanised steel strip or wire armoured with aluminum conductor of cross sectional area 120 Sq mm 3.00 core complete all as directed by the Engr-in-Charge.
S&F Cold shrinkable cable end terminatiion joints, indoor type suitable for UG XLPE insulated cable 120 sq mm size 3 core 11KV volts including taking down /Removing damaged end terminal joints,and making connection to transformer / link switch etc. and testing complete on full load, complete all as specified and as directed.
M&L Straight through joint of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120sqmm 3 core including taking down old one all as specified complete all as specified and as directed.
S&F Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3.5 core complete all as specified and as directed.
S&F Straight through XLPE cable jointing kit 1100V ( Earthed) grade for indoor termination heat shrinkable type complete with jointing materials and accessories suitable for XLPE armoured aluminium conductor cable of size 185 Sqmm 3.5 core complete all as specified and as directed.
S&F Thermoplastic, polycarbonate pole junction box outdoor type of size 155mm x 210mm x 92mm and box should have four terminal of 25 Sqmm and earth terminal along with MCB 6 Amps and fixed to pole with MS clamp made out of MS flat of section 25x 3mm including all necessary fittings and connection including taking down old unserviceable one complete all as directed by Enginner-in-Charge. Make:- Hansel Model No. KF 1616G or equivalent model from Make:- Sitex/ Universal.
S&F Thermoplastic, polycarbonate pole junction box outdoor type of size 93mm x 93mm x 62mm and box should have four terminal of 25 Sqmm and earth terminal along with MCB 6 Amps and fixed to pole with MS clamp made out of MS flat of section 25x 3mm including all necessary fittings and connection including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge. Make:- Hansel Model No. KF 0200B or equivalent model from Make:- Sitex/ Universal.
S&F junction pole box made of high quality thermoplastic polycarbonate (shock proof ,rust free,corrosion free,acid and chemical resistant,fire retardant, having high impact strength, of IK 9, made of halogen and silica free recyclable material IP66/67 degree of protection UV resistant, having high graded internally embedded gasket made of poly urethane should withstand glow wire test at 960 degree centigrade should be flame retradant and self extingushing with switch gear assemblies as per IEC-439-1 the junction box should have 4 power terminal of 25 Sqmm and earth terminal along with SP MCB of 6 Amp fitted in it the dimension of box shall be 205x255x112 in mm (LxHxD) make hensel KF 2500 G make of MCB L&T. and fixing to tubular /PCC pole using MS flat of size 25 x 3mm with suitable nuts and bolds including taking down old unserviceable one complete all as specified and directed by Engineer-in-Charge.
S&F Timer switch of analogue type for street light fittings, module 1 including taking down old unserviceable one complete all as specified and as directed. Make:- L&T Cat part No. AUTS01ANA00 or equivalent
S&F LED decorative post top lantern, 35/40 Watt capacity for energy efficient conservation upto 50% and with eco friendly lighting system with all accessories and necessary connection including taking down old unserviceable one complete all as specified and as directed. Make:-Bajaj cat part No. BGCL 40W/ Havells cat part No. RUBYPT35WLED830PSYMTOPC or Surya Cat part No. SLE PT 40W-ETPP or equivalent.
S&F PVC insulated, stranded copper electric cable, 2.5 Sqmm 2 core drawn into the steel tubular pole by drilling holes above the junction box and another holes near street light bracket including taking out old unserviceable copper wire complete all as specified and as directed.
S&F Land scape lighting 9/10 Watt ( LED Bollard) of IP 65 rated inverted pyramid type with soft 360º light distribution with necessary PCC base including necessary connection and all accessories including taking down old unserviceable one complete all as specified and as directed. Make-Bajaj cat No- BGBOM 605 9W LED WW/ Crompton cat No LBLSN-10-CDL or equivalent
S&F LED security light luminaries of 45W EDGE NXT LED housing in high pressure die cast aluminium with heat sink with electrochemically brightened and anodized aluminium reflector, heat resistant toughened glass including necessary fixing arrangement with GI Bracket of 32-40 mm dia suitable for LED fittings duly grouted in walls including taking down old unserviceable one complete all as specified and as directed. Make : Bajaj CAT NO- ENXT P 45L WW CR PC SD/Crompton greaves Cat No LSTP-45-CDL or equivalent
S&F LED Street light luminaries of 90W EDGE LED aerodynamically designed with excellent thermal management inbuilt tilt angle arrangement with IP66 protection including all accessories and necessary connection after taking down old unserviceable one complete all as specified and as directed. Make : Make :Bajaj CAT NO- BRTFG 90W LED CR /crompton LSTN-90-CDL-A or equivalent
S&F LED flood light luminaries of 80W with made in pressure diecast housing and high output emitter LED and IP66 protection including taking down the defective flood lights of any capacity complete all as specified and as directed. Make:- BJFL80W LED I of Bajaj/LFL-80-CDL/60 of crompton or equivalent
Supply, installation testing and commisisioning feeder pillar box CPRI type tested of size 1.5 mtrX1.2 mtrX.60mtr outdoor type confirming to IP-54, factory made r double door both front and back side, with locking arrangement prewired made out of 3mm thick CRCA sheet with 04 Nos legs, MS angle iron 40x40x6mm size 0.9mtr long suitable grouted in ground with PCC 1:3:6 type C2 and cement plaster 1:4 including two coats or synthetic enamelled paint over a coat of red oxide primer both internally & externally and including S&F aluminimum bus bar 600 amps rated duly coloured coded 04 Nos and connection through aluminium busbar of suitable size to MCCBs MCBsand power contactor and accessories fitted in it for incoming and out going cable, including LCD multi function meter for measuring voltage ampere, frequency, KW,KWH,, Phase indicating lamps LED type RYB duly fitted in Panel and all the acessroies to be connected with suitable copper conductor (control wiring) and power connection with busbar, connection of cable with necessary lugs, glands, PVC tape after taking down old unsrviceable feeder pillar box. (i) MCCB, 250 Amps, 4 pole, 415 volt, 25 KA fixed thermal and magnetic setting - 01 Nos (incoming). (ii) MCCB, 63 Amps, 4 pole, 415 volt, 25 KA fixed thermal and magnetic setting - 04 Nos (out going). (iii) MCB 32 Amp FP B curve- 2 Nos (out going) (iv) LCD Multifunction meter with CT -1No (v) Phase indicating Lamps LED type RYB complete - 01 Set (vi) Analogue time switch FM/1 QUARTZ type QT(daily) voltage 240 V, contact ratings 16A, 250V AC (resistive) single phase. . Make L&T cat no AUTS01AN00 -1 no (vii) Modular contactor 40A-4 NO, 3 module make L&T cat no AUMC2004003 -1 no Note-: Drawing shall be submited by the contractor before manufacturing for approval of accepting officer.
S&F MCCB 4 pole 400A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour of the panel and electric connection including taking down old one complete all as specified and directed.
S&F MCCB 4 pole 250A, 36KA, 415V thermal and magnetic adjustable type including making all fixing arrangement, cutting welding of existing panel board as per site requirment and painting the disturbed part of panel as per the existing colour ofthe panel and electric connection including taking down old one complete all as specfied and directed.
Taking out old unserviceable steel poles of any type and any sizes from the site of work complete all as specified and directed.
Supply and erecting steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts and screw as specified, type 410 SP-31, 9 Metre long including two coats of aluminium paint over one coat of red oxide primer complete all as specified and as directed by the Engr-in-Charge. Note:- Rates quoted shall be deemed to be inclusive of following works:- (a) Material and labour for painting of pole externally with one coat of black bituminous paint (upto planting depth) and above plinth block concrete collar with two coats of aluminium paint over a coat of red oxide primer including preparation of surface. (b) Material and labour for writing letter or figures (Block, Roman, Italic as Indian) with thick synthetic enamelled paint of apprised shade n exc 5 Cm height including numbering of pole all as directed by EIC.
M&L Preparation of old painted surface of existing steel tubular swaged pole 9 mtr long, cross arms, clamps, GI street light bracket etc and applying two coats of aluminium paint including writing pole number & bottom of pole painted with black paint with yellow strip around between the junction of aluminium paint and black paint complete all as specified and directed.
M&L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15Cm size including taking down old unserviceable Danger notice plate complete all as specified and directed.
Taking down old aluminium/ GI strip of any size and refixing the same with new saddles, clamps, screws etc to its original position complete all as specified and directed.
S&F GI strip of size 32 x 6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed.
S&F Air termination aluminium single pointed rod 12 mm dia, 300 mm long including takuing down old one complete all as specified and directed.
S&F Test point terminal block made of gun metal or phosphorus bronze size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hex head screw including takuing down old one complete all as specified and directed.
S&F Flexible PVC pipe of size 25mm suitable for electric connection including taking out old unserviceable PVC pipe.complete all as specified and as directed.
S&F Asthetically designed decorative hot dipped galvanised mild steel pole for street light / security light with grey powder coated finish including taking down old unserviceable street light pole, complete all as specified and as directed Make:-Havells cat part No. 6MPE or equivalent model of Crompton / Bajaj/ Surya
M&L ACP base with LG/Retro high Glow vinyl sign board along with pipe bracket with accessories including 0.20mm thick white rubber coated vinyl or synthetic vinyl 1 sheet painted with scotch / computer inject printing with outdoor ink and with 300x 720 DPI and also 140 DPI laminated with average 0.15mm high quality weather procted with chemical and including 1.5mm thick poly carbonated PVC milky / transparent sheet drawing art work computer designing including 22 SWG sheet frame work arrangement for fixing LED per sqm with necessary connection with 1.5 Sqmm single core copper conductor cable and 50mm dia Light grade pipe 3Rm x 2 Nos duly grouted 0.80m deep in PCC type B2 (1:2:4, using 40mm graded crushed stone aggregates) including all necessary fixing arrangement & tools and plants complete all as directed by Engineer-in-Charge .
Maintenance of 11 KV VCB by track out the breaker and checking , cleaning all the parts of the breaker with the help of vaccum cleaner/ air blower as required and checking all electrical and mechanical connection/parts of VCB and tightening the connections and testing all parts as required .testing the functions of all electrical components and mechanical components including the replacement of all bolts, nuts & washers,panel door glass, hinges etc( where ever directed with new one as per existing size, cleaning the entire VCB panel enclosure with all parts inside including bushing and out side of VCB with the help of air blower, testing the VCB with all protection relays,meters,triping circuit,closing circuits, anti pumping relay,DC power system, for confirming the proper functioning of all circuits , all meters, relays satisfactorily after racking in the breaker.for any make of VCB complete all as specified and as directed.
M&L Earthing complete with galvanised steel earth plate electrode 60 Cm x 60 Cm x 6.00 mm thick buried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strips 32x6 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip projected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore medium grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 Cm c/c both ways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal pf soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I including taking out of old unserviceable earth pit with all accessories complete all as specified and as directed.
Supply and filling of transformer oil as per IS 335/1993 for replacement/topping up of transformer oil upto optimum level of the transformer & HT link switch(VLE/Tee Off) having die electric strength not less than 60 KV complete all as specified and directed.
De-hydration and filtration of transformer oil direct from transformer / VLE / Tee off switch at site with help of transformer filtration and dehydration machine of capacity not less than 100 LPH of reputed company and testing of diel electric strength before and after dehydration and filteration work complete all as directed and specified. Note : (i) The die electric strength of the oil after dehyderation shall be 45 KV with 2.5mm gap between testing electrodes. (ii) The contractor shall arrange the equipments like transformer oil tester, required length of hose, clamps and all accessories/trools required to carry out the dehyderation and filteration work at site. (iii) Transformer oil required for topping up shall be measured and paid separately.
Taking down carefully any type of point wiring (light, fan, bell, socket or power) complete including fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets ( excluding light fittings) etc stacking at site for reuse of serviceable items and removal of unserviceable items from site and making good disturbed faces of walls, ceiling, floor etc to match with the existing surface complete all as specified and directed by the Engineer-in-charge.
M&L Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC casing caping of suitable size with all accessories including fabricated MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan /call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
All as per item No. 48.00 here-in-before but one 3 pin 5 amps socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 48.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC casing caping with all fittings and accessories of casing caping (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board..
M&L for Point wiring with PVC insulated and unsheathed FRLSH cable single core multistranded copper conductor 1.5 sqmm size, 1100 volts grade cable conforming to IS - 694 1990 drawn through and including PVC concealed conduit 20mm dia medium duty with all accessories including fabricated 1.6 mm thick MS terminal boxes fixed flush with wall surface with 3 mm thick plastic masonite laminated sheet top cover fixed with cadmium screw for mounting switches, sockets, regulator etc including 1.5 sq mm FRLSH stranded PVC insulated and unsheathed copper conductor earth continuity conductor to common earth and connecting to earth dolly all as specified for one light or fan point controlled by one switch single pole one way for light/ ceiling fan/ exhaust fan/call bell point/ Switch socket outlet 5 amps complete all as specified and as directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of Sch A
All as per item No.52.00 here-in-before but one 3 pin 5 amps socket outlet on the independent board with other switch complete all as specified and directed by Engineer-in-charge.
All as per item No. 52.00 here-in-before but one 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed by Engineer-in-charge.
M&L fo Point wiring surface type with 2.5 sqmm (Nominal Area) PVC insulated stranded single core unsheathed FRLSH copper conductor cable 1100 Volts grade drawn through with and including PVC concealed conduit with all fittings and accessories of conduit (like Tee, Bend etc) complete fixed to walls / ceiling etc with and including 2.5 Sqmm (nominal area) PVC insulated unsheathed, stranded, single core FRLSH copper cable as earth continuity wire connecting to common earth point (including supply & fixing of 1.6 mm thick pressed mild steel terminal boxes of suitable size with 3 mm thick PVC /plastic laminated sheet, top cover suitable sizes of brass screws and washers etc. for mounting sockets for 5 pin, 16 Amp Switch socket combination on independent board complete all as specified and directed. Note: (i) Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. (ii) Cutting Chases pinning shall be measured and paid separately under relevant item of Sch A
Cutting Chases pinning in, for concealed conduit wiring and making goods of disturbed surface not exc 15 cm girth with cement morter 1:3 complete all as specified and as directed.
S&F Switch piano flush type, single pole one way, 5 Amp complete all as specified and as directed.
S&F Bell/buzzer push 5/6 amps, flush type, white/ivory finish complete all as specified and as directed.
S&F Switch socket combination multi - purpose 3 pin 5 amp controlled by one switch flush type complete all as specified and as directed.
S&F Socket outlet 3/5 pin, 6 Amps, 240 volt flush type complete all as specified and as directed.
S&F Switch socket combination multipurpose 2 in 1, 6 pin 10 & 20 Amps 230 volt flush type complete all as specified and as directed.
S&F Call bell, ding dong AC 230 volts, single pole complete all as specified and as directed.
S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F Ceiling rose, surface bakelite, 65 x 50 mm,three terminals complete all as specified and directed.
S&F of existing energy efficient tube light fitting of capacity 10 watts suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat no CIS.103-10.3-SL or equivalent in Havells Cat No-ENDURALINEARNEOBS10WLED830SPCWH/ Bajaj cat no-BCLSB 10 WH or equivalent
S&F of existing energy efficient tube light fitting of capacity 20 watts suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat no CIS-305-40-57SL or equivalent in Havells Cat No-ENDURALINEARNEOBS20WLED865SPCWH/ Bajaj cat no-BCLAB20 or equivalent.
Supply and fixing of existing energy efficient tube light fitting of capacity 36 watts with LED fittings suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length after taking down old U/Scomplete all as specified and as directed. Make:- Havells Cat No-LUMILIN+XS36WLLED865SPCWH/ Bajaj cat no-BCLAB40WLEDP or equivalent.
Supply and fixing of existing energy efficient tube light fitting of capacity 30 watts with LED fittings suspended type / wall mounted type complete with LED tube Lamp and fitting with copper flexible PVC cable of 0.50 sq mm twin core not more than one metre in length after taking down old U/Scomplete all as specified and as directed. Make :- Crompton Cat No LSTS-30-CDL-M /Bajaj Cat no-ENXTP30LWHPO/Havells Cat No-ENDURACITYLITEPLATPLUSSL30WLED757SASYBOPC or equivalent
S&F LED lamps of 12 watts for energy conservation up to 50% and for efficient eco friendly cool lighting and for 30000 maintenance free burning hours including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton LED-12WDF-CDL-BI/ or equivalent Philips/ Havells/ Surya Roshni Ltd/ Bajaj/ Wipro/ C&S Electric Ltd.
S&F Recessed mounted 2X2 LED luminaries 36 watt White powder coated luminaries with screw less design and bottom opening to give high aesthetic and ease of servicing including cutting the existing any type of ceiling and making the ceiling as per the existing ceiling after fixing the light fittings including taking down old unserviceable one complete all as specified and as directed. Make:- Crompton cat no- LCTLSNE-36-FO-CDL/Bajaj cat no- BZRSQL 36W or equivalent Philips/ Surya Roshni Ltd/ Bajaj/ Wipro/ C&S Electric Ltd.
S&F LED T-8 tubular lamp, 20 Watt with extruded aluminium body PC diffuser and inbuilt driver including taking down old unserviceable one complete all as specified and as directed. Make :- Crompton Cat No-LT8-865-(2)/ Bajaj cat no-BLTB 15W CWC or equivalent
S&F LED T-8 tubular lamp,15 Watt with extruded aluminium body PC diffuser and inbuilt driver including taking down old unserviceable one complete all as specified and as directed. Make :- Crompton Cat No-LT8-865-(2)/ Bajaj cat no-BLTB 15W CWC or equivalent
S&F Ceiling fan regulator electronic Step type, solid state, , 240 volts, complete all as specified and as directed.
S&F Switch piano 5 amps single pole one way including unscrewing the bakelite sheet of switch board and refixing the bakelite sheet after replacing piano switch with new screws complete all as specified and directed.
S&F Switch socket combination multipurpose 3 pin 5 Amp flush type including unscrewing the bakelite sheet of switch board and refixing the bakelite sheet after replacing new one with new screws complete all as specified and directed.
S&F Socket outlet 3 pin 5 Amp flush type including unscrewing the bakelite sheet of switch board and refixing the bakelite sheet after replacing new one with new screws complete all as specified and directed.
S&F Switch socket combination multi - purpose 3 pin, 15 amp and one pin, 5 amp controlled by one switch shutter type including unscrewing the bakelite sheet of switch board and refixing the bakelite sheet after replacing new one complete all as specified and directed.
S&F Ceiling fan regulator electronic Step type, solid state, , 240 volts including unscrewing the bakelite sheet of switch board and refixing the bakelite sheet after replacing new one complete all as specified and as directed.
S&F Ceiling rose surface bakelite three terminals 240 volts as in repair complete all as specified and as directed.
S&F Lamp holder suitable for batten fittings as in repair complete all as specified and as directed.
S&F AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking out old unserviceable starter unit complete as specified all as directed.
Taking down old burnt/unserviceable submain wiring with aluminum/copper conductor PVC insulated cable of any size drawn through PVC casing caping/ PVC Conduit pipe including GI wire accessories etc. and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 4.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 4.0 Sqmm as earth lead drawn into pvc casing caping including all fittings complete all as specified and as directed. Note:- Two runs of 4 Sqmm conductor as main wire and one run of 4 Sqmm conductor as earth wire with one run of PVC Casing caping shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 6.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size 6.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 25 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
M&L Sub main wiring with 2 runs of single core FRLSH type PVC insulated unsheathed stranded copper conductor of size 10.0 Sqmm and one run of PVC insulated unsheathed multistrand copper conductor FRLSH type of size10.0 Sqmm as earth lead drawn into rigid non metalic PVC conduit of size 32 mm dia including all fittings complete all as specified and as directed. Note:- Two runs of 6 Sqmm conductor as main wire and one run of 6 Sqmm conductor as earth wire with one run of PVC conduit shall be measured as one unit.
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
S&F MCB SPN DB made up with sheet metal double door, phosphorised, powder coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 240 volts complete all as specified and as directed.
S&F Sheet metal enclosure for DB's when MCBs to be used 8 way single pole and neutral double door with 200 amps rated bus bar including all connection complete all as specified and as directed.
S&F Sheet metal enclosure for DB's when MCBs to be used 12 way single pole and neutral double door with 200 amps rated bus bar including all connection complete all as specified and as directed.
S&F MCB TPN DB made up with sheet metal, phosphorised, power coated, neutral link, earth bar and din rail, 4 way TPN with 200 amps rated bus bar, 240 volts complete all as specified and as directed.
S&F MCB TPN DB made up with sheet metal, phosphorised, powder coated, neutral link, earth bar and din rail, 8 way TPN with 200 amps rated bus bar, 240 volts complete all as specified and as directed.
S&F MCB 6 to 32 Amps, SP, 240 Volts ,B- Curve breaking capacity 10 KA complete all as specified and as directed.
S&F MCB 6 to 32 Amps, SP, 240 Volts , 'C' curve braking capacity 10 kA complete all as specified and as directed.
S&F MCB 6 to 32 Amps, DP 240 Volts ,B- Curve breaking capacity 10 KA complete all as specified and as directed.
S&F MCB 6 to 32 Amps,DP, 240 Volts , 'C' curve breaking capacity 10 KA complete all as specified and as directed.
S&F FP 63 Amps, 415 Volts ,C- Curve breaking capacity 10 KA complete all as specified and as directed.
Taking down ceiling fan of any size and make and any sweep from existing position after disconnection of electric connection complete as directed, dismantling blades, serviceing the fan motors, oilling/ greasing bearings and rehanging the same position complete all as specified and directed.
Rewinding of ceiling fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified and directed.
Removing unserviceable ceiling fan upto 1400 mm sweep from its original position for inspection removing bush / bearing, cleaning of bush / bearing, replacement of unserviceable / worn out bearing / bush, and capacitor removing burnt out coils from the slots, cleaning and repairing of slots, complete including reassembling and refixing of fan complete including steel clamp with nuts bolt hook for fixing of fan and including 1.5 Mtr length connecting rod and fixing back in position after servicing complete all as specified and as directed. Note:- (i) Spares will be measured and paid separately as "Supply only" under relevant items here-in-after
Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan of any make.
Supply only capacitor of 2.5 mfd for ceiling fan
Supply only gun metal bush of suitable size for ceiling fan of sweep 1200mm/1400mm as per existing one
Supply only nuts, bolts, for Ceiling fan
Supply only shafts for ceiling fan suitable for upto1400mm sweep
Supply only PVC connector for Ceiling Fan
Supply only rubber reel insulator for Ceiling fan
Supply only S hook as standered shape and size for fixing Ceiling fan complete all as specified and directed.
Supply only mild steel down rod 16mm dia ,1.5m long for fixing Ceiling fan complete all as specified and directed.
M&L for painting of ceiling fan of any size and sweep complete with synthetic enamel paint by spraying including filling with cavities with filler, after cleaning all dust etc complete all as specified and directed.
S&F Wall fans complete 400mm sweep power input 60 watts, min speed 1350 RPM, Min air delivery 85 CFM, 240V 50 Hz including taking down old one complete all as directed and specified. Note: Taking down old fan to be deposited to MES store yard.
S&F Ceiling fans complete with blades, down rods, electronic regulator and acessories 230 V 1200 mm sweep Min air delivery 210 CFM with service Value 6.00 BEE 5 Star rated with brushless direct current motor (BLDC) including taking down old one complete all as directed and specified. Note: Taking down old fan to be deposited to MES store yard.
S&F Exhaust fan AC single phase 240 V of size 300 mm sweep with louver specially designed by toilet/bathroom in domestic ventilattion metal body and blade, powder coated metalic finishes heavy duty motor, protective bird guard complete all as directed and specifed. Note: Taking down old fan to be deposited to MES store yard.
Taking down exhaust fan / padestal fan/ wall fan 350 to 600 mm sweep from existing position after disconnection of electric connection complete as directed, dismantling blades, serviceing the fan motors, oilling/ greasing bearings and rehanging the same position complete all as specified and directed.
Rewinding of exhaust fan motor with super enamelled copper winding wire of suitable size & varnishing including testing of fan after rewinding complete all as specified.
M&L Painting of exhaust fan of any size and sweep complete, in situ with approved colour synthetic enamel paint by spraying including filling with cavities with filler, one coat after cleaning all dust etc.complete all as specified and directed.
Removing unserviceable exhaust fan upto 300 mm sweep from position replacement of unserviceable bush and bearing, open the covers for repairs removing burnt out coils from the slots, cleaning and repairing of slots and painting of fan with one coat of synthetic enamel paint by spraying and fixing back in position after servicing complete all as specified and as directed. Note:- (i) Spares such as bearing and bushes etc will be paid separately as Supply only under relevent items here-in-after.
Supply only bush suitable for exhaust fan.
Supply only ball bearing suitable for exhaust fan.
Supply only capacitor 3.15 mfd for exhaust fan of suitable sweep.
Taking down carefully storage type water heater (Geyser ) of any make of capacity 25 Ltrs after removing all electrical and water connection from installed position at different locations,dismantling the geyser into parts for inspection.Checking /testing of all parts/accessories like appratus plate,heating element,thermostat switch,neon lamp, water tank,safety valve, spacer ring, rubber gasket,nut-bolts,inspection plate, bottom& top cover etc. complete,de-scaling of water tank and brazing the same to make it leak proof complete inclduing replacement of unserviceable spare parts and re-installation, making electric and water connections and testing complete all as specified and directed. Note :- Spare parts shall be measured & paid seperately as "Supply only" Items .
Supply only Heating element including rubber washer suitable for existing geyser of capacity 25 Ltrs.
Supply only PVC Connection of length not less than 30 Cm suitable for incoming and out going.
Supply only Apparatus plate (head assembly) complete all as per existing suitable for 25 Ltrs geysers of any make complete including rubber packing.
Supply only Thermostat switch suitable for geyser of capacity 25 Ltrs.
Supply only Inspection plate made out of 22 gauge MS sheet white painted (in two parts) suitable for geyser of capacity 25 Ltr.
Supply only Split plate (top cover ) made out of 22 gauge MS sheet,white painted suitable for geyser of capacity 25 Ltrs.
Supply only Safety valve (fusible plug) as per existing suitable for 25 Ltrs gyser.
Supply only Insulating materials (Glass wool) suitable for 25 Ltrs geyser.
Supply only PVC insulated copper conductor 6 Sqmm size, 3 core 1100 Volts grade.
Supply only 3 pin plug top 15A suitable for metal clad enclouser 240 Volts complete suitable for existing one.
Supply only Neon Lamp round or square in shape as per existing.
Supply only Element holding clamp as per existing.
Supply only Storage tank fabricated from copper sheet gauge suitable for geyser of capacity 25 Ltrs of make as specified and approved.
S&F Thermostat switch suitable for geyser of capacity 25 Ltrs as in repair complete all as directed specified and directed.
S&F Modular type switch 6 Amps 230V AC single module one way as in repair complete all as directed specified and directed.
S&F Modular socket outlet 10/20 Amps 3 Pin shuttered type 230V AC 2 module as in repair complete all as directed specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 1 modules as in repair complete all as directed specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 2 modules as in repair complete all as directed specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 3 modules as in repair complete all as directed specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 6 modules as in repair complete all as directed specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 8 modules as in repair complete all as directed specified and directed.
S&F Modular cover plate with frame for fixing of modular switches/sockets complete for 12 modules as in repair complete all as directed specified and directed.
S&F Modular socket outlet 6 Amps 3 Pin shuttered type 230V AC 2 module as in repair complete all as directed specified and directed.
S&F Modular type fan regulator Step type ,100 Watt, one module, 230V AC single module as in repair complete all as directed specified and directed.
S&F Modular type fan regulator Step type ,100 Watt, two module, 230V AC single moduleas in repair complete all as directed specified and directed.
S&F Modular bell push, 6/10 Amps 230V AC single module as in repair complete all as directed specified and directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 1 Module/ 2 Module as in repair complete all as directed specified and directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls. 3 Module as in repair complete all as directed specified and directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls 4 Module as in repair complete all as directed specified and directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls 5 Module as in repair complete all as directed specified and directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls 6 Module as in repair complete all as directed specified and directed.
S&F Sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls 12 Module as in repair complete all as directed specified and directed.
S&F MS louvers made of 22 gauge MS sheet of suitable for 300 mm sweep exhaust fan complete with grouting of bolts in the wall up to any height of the building and bolts of size as directed and painting the louvers with synthetic enamel paint two coat after one coat of red oxide primer as in repair complete all as specified and directed.
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.00 mm thick burried in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to GI strip 4 mm as earthing lead by means of bolts, nuts, check nuts and washers of GI or steel, GI strip proected by 40 mm bore light grade GI pipe and other end connected to earth test point as directed including funnel with watering pipe 20 mm bore light grade galvanised iron, wire mesh, charcoal or coke common salt laid in alternative layer of 15 cm (complete thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1, 50 mm thick pre-cast RCC (1:2:4) type B-1 normal mix cover slab reinforced with 8 mm dia TMT bar 10 cm c/c bothways and single handle of 10 mm dia round bar including necessary excavation, earth work etc. in soft / loose soil and disposal of soil to a distance n. exc. 50 m and necessary testing on completion all as shown in electrical plate No. 3 MES Schedule Part-I complete all as specified and as directed.
Taking up / down the following size of water mains and connections/fittings of any type from trenches/ walls / floors (of any location) for replacement / re-use in old / new location/diversion complete all as specified and directed by the Engr-in-Charge. Note: Necessary earthwork, if any , will be measured and paid separately under relevant items (a) Bore size 100 mm
(b)Bore size 80 mm
(c) Bore size 50 mm
(d) Bore size 40 mm
(e) Bore size 25 mm
(f) Bore size 20 mm
Supply and Laying Steel Water Tubing 100mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.
Supply and Laying Steel Water Tubing 80mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.
Supply and Laying Steel Water Tubing 50mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.
Supply and Laying Steel Water Tubing 40mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.
Supply and Laying Steel Water Tubing 25mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.
Supply and Laying Steel Water Tubing 20mm Bore (dia), Galvanised, ‘Medium Grade’ with all Fittings, laid in trenches or any other Situation, complete as all specified and as directed.
S&F UPVC pipes 20 mm outer diameter (Sch-80) fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
S&F UPVC pipes 25 mm outer diameter (Sch-80) fixed on Walls, Ceiling or laid in Floors or any other Situation, complete as all specified and as directed.
Taking up / down the following size of water mains and connections/fittings of any type from trenches/ walls / floors (of any location) for replacement / re-use in old / new location/diversion by burning out/removing of lead joint/tyton joint/rubber gasket joint all as specified and directed by the Engr-in-Charge. Note: Necessary earthwork, if any , will be measured and paid separately under relevant items (a) Bore size 80 mm
(b) Bore size 100 mm
Supply, laying, connecting and testing of Cast iron pipes 80 mm bore of pipe with spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and directed.
Supply, laying, connecting and testing of Cast iron pipes 100 mm bore of pipe with spigot and socket ends centrifugally cast class LA in any length laid in trenches complete all as specified and directed.
S&F MS pipe 80 mm dia medium grade and fixing the pipes with existing system by cutting welding including fixing of new flanged joints with rubber gasket incl nuts,bolts & washers as per site requirement with proper alignment complete all as specified and as directed.
S&F MS pipe 100 mm dia medium grade and fixing the pipes with existing system by cutting welding including fixing of new flanged joints with rubber gasket incl nuts,bolts & washers as per site requirement with proper alignment complete all as specified and as directed.
S&F Check valve 80 mm dia screwed end IS-778-84+1 including taking out old us check valve after lifting of suction pipe from UG sumps and again lowering the same complete all as specified and directed.
S&F Check valve 100 mm dia screwed end IS-778-84+1 including taking out old us check valve after lifting of suction pipe from UG sumps and again lowering the same complete all as specified and directed.
Supply and fix Cast Iron Sluice valve of 80 mm bore of pressure rating PN-1.6 conforming to IS : 14846 – 2000 specifications comprising of cast iron body with control assembly of flanged both ends, brass spindle with extended iron rod of 25mm dia & 3.00 m long alongwith iron wheel head, bolts, nuts & washers with 3mm thick rubber gaskets including taking out the old unserviceable one complete all as specified and directed.
S&F Cast Iron Sluice valve of 100 mm bore of pressure rating PN-1.6 conforming to IS : 14846 – 2000 specifications comprising of cast iron body with control assembly of flanged both ends, brass spindle with extended iron rod of 25mm dia & 3.00 m long alongwith iron wheel head, bolts, nuts & washers with 3mm thick rubber gaskets including taking out the old unserviceable one complete all as specified and directed.
Supply and fix Cast Iron Sluice valve of 150 mm bore of pressure rating PN-1.6 conforming to IS : 14846 – 2000 specifications comprising of cast iron body with control assembly of flanged both ends, brass spindle with extended iron rod of 25mm dia & 3.00 m long alongwith iron wheel head, bolts, nuts & washers with 3mm thick rubber gaskets including taking out the old unserviceable one complete all as specified and directed.
Repair to unserviceable sluice valve 150mm bore by taking out cleaning & derusting with acid washing all the parts after removing from site & replacement of brass spindle, GM lock nuts, gaskets, nuts both & washer etc to make fully serviceable and re-fixing the same in original position including connection complete all as specified and directed. Note : Brass spindle will be measured & paid separately.
Repair to unserviceable sluice valve 100mm bore by taking out cleaning & derusting with acid washing all the parts after removing from site & replacement of brass spindle, GM lock nuts, gaskets, nuts both & washer etc to make fully serviceable and re-fixing the same in original position including connection complete all as specified and directed. Note : Brass spindle will be measured & paid separately.
Repair to unserviceable sluice valve 80mm bore by taking out cleaning & derusting with acid washing all the parts after removing from site & replacement of brass spindle, GM lock nuts, gaskets, nuts both & washer etc to make fully serviceable and re-fixing the same in original position including connection complete all as specified and directed. Note : Brass spindle will be measured & paid separately.
Supply only brass spindle suitable for 150mm bore sluice valve complete all as specified and directed.
All as per item No.-183.00 but suitable for 100mm bore sluice valve complete all as specified and directed.
All as per item No.-183.00 but suitable for 80mm bore sluice valve complete all as specified and directed.
S&F Repacking stuffing box of sluice valve spindle including taking apart and reassembling suitable for 150mm bore sluice valve complete all as specified and directed.
S&F Repacking stuffing box of sluice valve spindle including taking apart and reassembling suitable for 100mm bore sluice valve complete all as specified and directed.
S&F 150mm bore Cast iron non return valve double flanged (class-'B) high pressure conforming to IS-5312 ete with nuts, bolts & washer gaskets etc including taking down the old unserviceable one complete all as specified and directed.
S&F 100mm bore Cast iron non return valve double flanged (class-'B) high pressure conforming to IS-5312 ete with nuts, bolts & washer gaskets etc including taking down the old unserviceable one complete all as specified and directed.
S&F 50 mm bore Gun metal gate valve as per IS : 778-84, marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repair complete as all specified and as directed.
S&F 40 mm bore Gun metal gate valve as per IS : 778-84, marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repair complete as all specified and as directed.
S&F 25 mm bore Gun metal gate valve as per IS : 778-84, marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repair complete as all specified and as directed.
S&F 20 mm bore Gun metal gate valve as per IS : 778-84, marked Class-2 Pressure tested 2.4 Mpa with iron wheel head, screwed both ends for iron pipes or for unions as in repair complete as all specified and as directed.
S&F Water pressure gauge 100mm dia in the main line of pump including necessary dirlling welding, taping/Threading of existing line etc with taking out unserviceable one complte all as specified directed by Engr-in-Charge.
Leakage detection in GI water mains upto 100mm bore and necessary repairs including cutting, threading for addition/alteration and insertion necessary of fittings like tee,elbow, branches pieces etc complete all as directed by the Engr-in-Charge.
M&L for Construction of brick masonary valve pit chamber of size 1050x1050x1050mm internal dimension using sub class-'B' bricks in CM (1:6) plastering in cement mortar (1:4) externally & internally extended to 15 cm below ground level including PCC bed 10 cm thick in PCC 1:3:6 Type C2 with MS frame fabricated by angle of size 40 x 40 x 6mm complete with top cover of 3 mm thick MS sheet & locking arrangement and painting with two coats of synthetic enamel over a coat of red oxide primer including demolition of old unserviceable damged valve pit complete all as specifed and directed.
S&F CI /DI bends (any type radious & angle) tapers any type (strain out bend) increasing decerising or double socket etc Tee pieces (single branch) junction double brash cross collars (flanged or socket & spigot suitable for upto 150mm DI/CI pipe after taking out the old unserviceable one complete all as specifed and directed.
Dismantling the channel base and taking out the pump & motor of capacity 20 HP AC 3 phase 415 volt disconnecting the pump motor, opening the pump, cleaning derusting thoroughly, machining inside body of the pump & repairing by replacement collar rings, gaskets, Impeller locknuts, shaft key etc re-assembling the pump including installtion & testing commissioning complete all as specified and directed. Note:- Spare parts other than minor spares required to be replaced shall be measured and paid seperately under 'Supply only' items below.
Stainleel Shaft
Brass Impeller
Gun metal Bush
Pump Bearing
Motor Bearing
Coupling pully of Pump motor
M&L Rewinding of electric motor AC 3phase 415 volts 50- HZ of capacity 15/20 HP with supper enamel copper wire of same size and heating and vernishing after removing the old burnt out winding including replacement of bearing etc testing & commissioning complete all as specified and directed by Engr-in-Charge.
M&L Rewinding of electric motor AC 3phase 415 volts 50- HZ of capacity 7.5/10 HP with supper enamel copper wire of same size and heating and vernishing after removing the old burnt out winding including replacement of bearing etc testing & commissioning complete all as specified and directed by Engr-in-Charge.
M&L Rewinding of submersible motor AC 3phase 415 volts 50- HZ of capacity 12.5/10 HP with supper enamel copper wire of same size and heating and vernishing after removing the old burnt out winding including replacement of bearing etc testing & commissioning complete all as specified and directed by Engr-in-Charge.
Repairs Panel board for pump of any size/ any type by disconnecting and taking out old unserviceable wires and spare parts and rewiring the same with same size of copper wire, replacment of nut & bolts with washers,cleaning with blower, painting with one coat of synthetic enamel painting of existing colour including necessary preparation of surfaces including testing and commisioning complete all as specified and directed by Engr-in-Charge. Note:- Any other Electrical fittings connecting to panel board should be measured and paid separately.
Supply only fully automatic star delta starter 10HP MN 25 F, 415 Volt, 50 Hz with relay range 14-23 Amps including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
Taking out old unserviceable ML-4 contactor from existing panel of motor starter for repalcement after disconnection all electrical connection and supply and fixing 3 pole power contactor type ML-4, including all electic connection and testing complete all as specified and directed by Engr-in-Charge.
All as per item No. 210.00 above here in before but timer GT-200, complete all as specified and directed by Engr-in-Charge.
S&F Single phase starter relay range 11-18 Amps as per after taking out old unserviceable starter including disconnection and connection complete all as specified and directed by Engr-in-Charge.
S&F FASD starter in SS enclosure ML 2 F, 415 Volt, 50 Hz with relay range 20-32 Amps including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
S&F Monoblock pump 1HP single phase 230 volts,having suction/discharge up to 20/25mm,head range 10 to 30 mtrs including all accessories, foundation work including taking down old unserviceable one complete all as specified and directed by Engr-in-Charge.
M&L Elect connection for pump/motors of PVC insulated, round sheathed copper conductor, flexible, industrial cable of 3 core 6.0qmm 1100 volts grade confirming to IS 694 including taking out old unserviceable one complete all as specified and directed by Engr-in-charge. .
Lifting and lowering of submersible pump and motor set,3 phase of capacity10HP from bore well with the help of chain pully including scaffolding and all other necessary arrangement complete all as specified and directed by Engr-in-Charge. Note:- (i) One lifting and one lowering should be measued as one unit. (ii) Replacment of minor spare parts i.e impeller key, neck ring, coupling bush and key,nuts bolts, washer etc. reassembling the pump after routine maintenance of serviceable spares and replacment of spare part shall be measured and paid separately under relevant items of BOQ.
Supply only Suction Bush
Supply only Stage Casing Bush
Supply only Stainless Steel Shaft
Supply only Stainless Steel Sleeves
Supply only GM Impeller
Supply only Stage casing Ring
Supply only NRV
Supply only Short piece with flange
Supply only Stainless Steel Nut and Bolt with washer
Supply only MS Nut and bolt with washer
Supply only Rubber Gasket
De-watering and cleaning of underground sumps or service tank upto 25000 Gln capacity cleaning the sump with wire brush,cloth ,bleaching powder,removing alll dirt scale from tank and from mouths of circulating pipes etc through drain pipe or by manually including writing with white paint in tank wall as "TANK CLEANED ON" with date ,month and year with a minimum 10 CM height capital lettrs/numbers and conducting all connections (if any) after cleaning and testing at different multi-storeyed buildings complete all as specified and directed by Engineer-In-Charge.(a) To drain out the water by using exit valve or our own high capacity dewatering system. (b) Cleaning all the algae formation insied the tank by using TERBAC G5 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.(c) Fresh water cleaning by high speed jet pump (d) first bacteria screening is desertification by using TERBAC G5 a govt laboratory certified branded halogen compound. (e) Cleaning of the floor of the water tank by industrial vacuum cleaner. (f) The second bacteria screening and sterlizing method by using ultra violet ray with in the tank and kills all suspended bacteria. (g) Cleaning the third bacteria screening and sterilize the floor of the water tank by using laboratory certified branded strong oxidizing agent TERBAC G65.
All as per item No. 228.00 above here in before but UG capacity 20000 Gallon complete all as specified and directed by Engr-in-Charge.
S&F Electric water heater capacity 25 litre,storage type steel body with copper inner tank and heating element upto 2 KW,BEE 5 star rated complete with pressure reducing valve including all accessories like safety valve,thermostat,NRV,connection piece etc complete all as specified and directed. Note: Taking down old fan to be deposited to MES store yard.
Taking down and opening of Cast Iron spigot and socket pipe joint and applying with run lead joint for the following size CI water mains any size and shape, complete all as specified and directed by Engineer-in-Charge (a) Bore size 80 mm
(b) Bore size 100 mm
(c) Bore size 150 mm
Taking down and opening of Cast Iron flanged pipe joint and applying rubber board gasket for the following size CI water mains any size and shape, complete all as specified and directed by Engineer-in-Charge (a) Bore size 100 mm
(b) Bore size 150 mm
AUTO ELECTRICALS
MODERN AGENCY
Globe Electricals
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .