| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.6 LAccepted-AOC 1101 A WING SACHDEV COMPLEX JANGAL MANGAL RAOD BHANDUP W MUMBAI 400078 | MUMBAI SUBURBAN | MAHARASHTRA | 400078 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹39.5 L+₹4.6 L (13.3%)Rejected-AOC SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON WEST MUMBAI 400 104 | MUMBAI | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹37.6 L+₹2.8 L (8.07%)Rejected-AOC BLOCK C 14 GROUND FLOOR PLOT 618 624 BHIVANDIWALA TERRACE JAGANNATH SHANKARSHETH MARG DHOBI TALAO NEAR KALBADEVI POST OFFICE MUMBAI 400002 | MUMBAI | MAHARASHTRA | 400002 | L3 | Rejected-AOC NOT LOWEST | |
| 4 | L4₹42.0 L+₹7.2 L (20.7%)Rejected-AOC | L4 | Rejected-AOC NOT LOWEST | |
| 5 | Rejected-Technical | - | Rejected-Technical BEING UNENLISTED FIRM, EMD, DOCUMENTS AS REQUIRED NOT SUBMITTED AND UPLOADED |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
24 Aug 2020, 6:00 pmClosed
GE (NW) MANKHURD
GE (NW) MANKHURD, MUMBAI-400 088
REPAIR/MAINTENANCE TO E/M ELECTRIC SUPPLY INSTALLATION AND ELECTRIC PANELS, CEILING FAN AND HEATING APPLIANCES AND FIRE ALARM SYSTEM AT MANKHURD, TS MAHUL AND THANE AREA UNDER GE (NW) MANKHURD
2020_MES_363813_1
8991/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (NW) MANKHURD
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE (NW) MANKHURD
₹70,000
Yes
26 Sept 2020
24 Jul 2020
27 Aug 2020
24 Jul 2020
24 Aug 2020
11 Aug 2020
24 Jul 2020 - 7 Aug 2020
Amount
S & F in replacement MCCB 63 Amps, 25 kA Triple Pole 415 Volts including connecting up complete in existing panel with lugs/ Glands all as specified and directed.
M&L for earthing complete with GI earth plate electrode 600x 600x 6 mm thick buried directly in ground with top edge of the plate not less than 1.5 mtrs below normal ground level and connected to earth test point by means of GI Strip of size 32 X 6 mm all as specified and shown in electric plate No 3 of MES SSR Part-I 2009 including earthwork, PCC chamber, CI cover, protection and watering pipe, funnel, mesh etc all as required at site and all as directed and including taking down of old earthing materials Note: (1). 7.5 RM GI strip in deemed to be included in quoted rates beyond 7.5 RM strip shall be measured and paid separately (2) Rate quoted by the tenderer is deemed to include salt & Charcoal upto & above 450 mm top of GI plate.
Taking down existing UG cable and supply & Lay XLPE insulated, heavy duty 1100 volt grade electric armoured LT UG cable with aluminium conductor of size 70 Sqmm 3.5 Core in trenches/along the wall/including saddles, spacers making all connections, including scaffolding if any required for saddling the cable in walls of building of height up to 25 meter complete wih aluminium lugs as required at site complete all as specified and directed.
Supply and fixing in replacement of 40 Watt All in one integrated Solar Street Light fitting with complete system with Battery Lithim ION, 11.1 V, 39.6 AH including braket complete all as specified and directed. Make : Sai Industrial alliances pvt ltd Cat part No : AXN-40W or as approved by GE
Comprehensive Repairs and maintenance of Fire alarm system installed at NAD Trombay, the system comprises of main Fire alarm Control Panel - 1 Nos with battery back up, Repeter panel - 2 Nos, Motor operated Sirem - 2, Manual call Point - 13 Nos installed at various location. (a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommended the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item (b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alarm panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors. (c) Testing the firealarm system including checking of each MCP and maintining serviceablity records on monthly basis. (d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning. Unit per month Means - Calender month irrespective of days i.e 28 days to 31 days
Comprehensive Repairs and maintenance of Fire alarm system inslalled at 31 WEU Thane. The system comprises main Fire alarm Control Panel - 1 Nos with battery back up, Manual Call Point (MCP) - 16 Nos, Electronic Hooter - 16 Nos Heat Cum Smoke Detector - 98 Nos, Remote Response Indicators - 77 Nos, installed at various locations, The scope of work comprising of the following (a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommended the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item (b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alarm panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors. (c) Testing the firealarm system including checking of each MCP and maintining serviceablity records on monthly basis. (d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning. Unit per month Means - Calender month irrespective of days i.e 28 days to 31 days
Comprehensive Repairs and maintenance of Fire alarm system inslalled at Naval Station Thane. The system comprises main Fire alarm Control Panel - 1 Nos with battery back up, Manual Call Point (MCP) - 10 Nos, Electronic Hooter - 10 Nos, Heat/Smoke Detector - 63 Nos, Remote Response Indicators - 25 Nos, installed at various locations, The scope of work comprising of the following (a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommended the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item (b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alarm panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors. (c) Testing the firealarm system including checking of each MCP and maintining serviceablity records on monthly basis. (d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning. Unit per month Means - Calender month irrespective of days i.e 28 days to 31 days
Comprehensive Repairs and maintenance of Fire alarm system inslalled at TS Mahul The system comprises main Fire alarm Control Panel - 3 Nos with battery back up, Wire less photo electric Smoke Detectors - 25 Nos, Repeater Panel - 6 The scope of work comprising of the following (a) The entire system shall be inspected and checked by the service engineer of the main manufacturer and recommended the replacement of spares and functional parts etc in proper inventory. The replaced parts shall be measured and paid for seperately as supply only under respective items of this schedule but fixing and testing etc is deemed to be included in the unit quoted rate against this item b) Checking of all internal & external wiring for open, Short, Damaged & loose Connections of all MCP, Main fire alarm panel, Repeater Panel, Siren motor, replacing of broken Break glass. Cleaning of Smoke detectors. c) Testing the firelarm system including checking of each MCP and maintining serviceablity records on monthly basis. (d) All main fire control including battery, smoke detector, temperature heat detectors, connected control wiring etc shall be checked for normal functioning. Unit per month Means - Calender month irrespective of days i.e 28 days to 31 days
Supply and fix in repairs 16 Zone semi addressable ANG–4LM-MAIN master fire alarm control panel, with siren controller, with alpha numeric crystal display, panel mounted key pad, LED indicators to display system status such as system on, fault, fire, fault, with inbuilt buzzer, power supply modules, fire relay, hooter relay, fault relay, resistor pack, signal convertor card, CDRPT card, transmitting & receiving card, Test all as directed by engineer - in charge Make - ANG/PCD Fire System/Safetech/ Zicom/ Apollo.
Supply and fix in repairs 16 Zone repeater panel, the repeater panel shall comprise of site plan of NAD (T) and the locations of 13 Nos of Manual Call Point (MCP) shall be provided with LED lamps, particular LED lamps shall glow on activation of MCP. The panel shall be provided with power supply modules, receiver modules, siren controller module, siren operating contactors, MCB TPN 20 Amps, LED indicators Test all as directed by engineer - in charge Make - ANG/PCD Fire System/Safetech/ Zicom/ Apollo.
Supply and fix in repairs flame proof manual call point (MCP) with 24 Volt addressable MCP card and hammer, including making addition/alternation to existing supports of MCP. Make - ANG / PCD Fire System / Safetech / Zicom / Apollo.
Supply and fix in repairs Switch Mode Power supply operating at input voltage range 180 to 270 Volts and having maximum out put voltage of 28.5. Make - Proxymon/Omron
Supply and fix in repairs maintenance free 12 Volts 15 AH battery suitable for fire alarm panel.
Supply and fix in repairs maintenance free 12 Volts 26 AH battery suitable for fire alarm panel.
M & L for Removing of burnt electric motor 1 HP to 3 HP, 440 Volts of fire alarm siren after dismantling of all electrical connections & transporting from site to workshop, rewinding of electric motor with super enameled copper wire after removing of old burnt coil, replacing of bearing, cleaning of slots properly, heating in heat chamber after varnishing and testing at site and including scrapping the old paint and applying one coat of zinc chrome red oxide primer and applying two coat of synthetic enamel paint all as specified and directed. Note :- Cost of insulation paper, varnish and any nuts, bolts and lugs required for the job shall be deemed to be included in the quoted rate
Supply & fixing in repairs Detectors complying with and type certified to EN-45 type multisensor detector with heat and smoke combination photo electirc / optical with base with self built intelligence as per IS - 11360 complete all as specified and directed. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech,
Supply and fix in repairs DOL starter 3 Phase 440 volts suitable for 2 HP fire alarm siren motor.
Supply and fix in repairs response indicator complete with cable connection. Make - Apollo/Zicom/Hochuki/Edward/PCD/Safetech,
Supply and fix in repairs Electronic hooter 24 Volt DC complete for fire alarm system complete with acessories. Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD
Supply and fix in repairs conventional manual call point with pill box complete with hammer, chain and all fixtures Make - Safetech, Minimax, ECD, Apollo, Zicom/PCD
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth and getting out in any type of soil all as specified and directed.
Returning filling in , excavated soil including spreading, leveling and well ramming in layers not exc 25cms each any type of soil all as specified and directed.
Removing the excavated materials not exc 50mtr and depositing where directed at a level not exceeding 1.5 mtr above the staring point all as specified and directed.
M&L for sand cushioning by spreading in trenches fine dry river sand by gently by punning down manually as in cable protection all as specified and directed.
Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified and directed.
Laying only un-reinforced precast concrete cable cover class LV, type-I, flat size 250mm x 150mm x 40mm laid in trenches all as specified and directed.
M & L for taking down of old cables & Supply & lay armoured XLPE Insulated 1.5 Sqmm 4 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed.
M & L for taking down of old cables & supply & lay armoured XLPE Insulated 1.5 Sqmm 2 core multi stranded copper conductor cable along the walls, in trenches ducts, ceiling / connection to control panel, manual call point complete with termination, testing and commissioning all as specified and directed.
Supply, installing, testing and commissioning of powder coated LT feeder panel cubical outdoor type, channel mounted, compartmentalized in construction, all confirming to IS 8623 Part I 1993 CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 120 of CA made out of 3 mm thick CRCA sheet & suitable size to accomadate all accessories / fittings, inommers, outgoings, bus-bars other components / parts etc. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC / epoxy insulator. The bus bars shall have copper extension links for connecting with outgoings MCCB. The cubicle shall have a bottom channel & free standing frame made of angle iron of size not less than 40mm x40mm x6mm thick. A detachable predrilled mild steel gland of thickness not less than 3 mm thick powder coated shall be used at the bottom for enty of armoured cable of adequate size with glands. The panel shall be front openable, lokable / Openable by Key. The panel shall be dust, vermin proof and powder coated of approved thickness complete including CT's control wiring with 1.5 Sqmm copper conductor wire and consisting of the following also including taking down of old unsv panel after disconnecting exiting cable & reconnecting the cables to new panels, removing the existing 11 Nos Energy Meters & refixing the same Energy Meters in new panel and including providing PCC foundation platfrom, execavation, grouting bolts etc. complete all as specified and directed :- (a) Copper bus bar 200 Amps for 3 Pahase and Neutral - 01 Set (b) MCCB TP- 63 Amp, 415 Volts, 25 KA - 01 No (c) MCB SPN 40 Amps, 10 KA, 230 Volts, 'C' Series - 12 Nos (d) RYB indicators - 01 Set (e) Digital VAF Meter Conforming to Cat No - NEMFVIF00000 of HPL - 1 Nos (f) Space for fixing of 11 Nos Energy Meter of capacity 10-60 Amp Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 120 of CA
All as per item No 31.00 but with following acessories (a) Copper bus bar 200 Amps for 3 phase and Neutral (b) MCCB TP 63 Amps 415 Volt 25 KA - 1 Nos (c) MCB SPN 40 Amps, 10 KA 230 Volts - 10 Nos (d) Space for Fixing 9 Nos of Single Phase Energy Meter of Capacity 40 Amps (e) Digital VAF Meter Conforming to Cat No - NEMFVIF00000 of HPL - 1 Nos (f) RYB Indicators - 1 Set Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 120 of CA
Supply install, test and commissioning of Powder coated LT Feeder panel cubical in door type wall mounted compartmentalized in construction all Confirming to IS 8623 Part 1 1993 CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 120 of CA made out of 2 mm thick CRCA sheet & suitable size to accommodate all accessories / fittings, to accommodate incoming MCCB and TPN Copper bus bars, incomer MCCB and outgoing MCCB, MCB, Contactors The TPN bus bars shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulator. The bus bar shall have copper extension links for connecting with out going MCCB. The cubicle shall have a detachable predrilled gland plate of thickness not less than 3 mm thick powder coated should be used at the bottom for entry of armoured cable of adequate size with glands. The above panel shall be front openable lockable /openable by key from both side. Including wall mounting brackets. The panel shall be Dust, vermin proof and powder coated of approved thickness complete including CTs, control wiring by 1.5 sqmm Wire and consisting the following, including taking down of old unsv panel after disconnecting existing cables & reconnecting the cables to new panels and including PCC foundation, excavation, grouting bolts a) Copper bus bar 200 Amps for 3 phase and Neutral b) MCCB TP 100 Amps 415 Volt 25 KA - 1 Nos c) MCB SPN 40 Amps, 10 KA 230 Volts - 7 Nos d) Space for Fixing 7 Nos of Single Phase Energy Meter of Capacity 40 Amps e) RYB Indicators - 1 Set f) Taking down Existing energy meters and re fixing the energy meters at new panel Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 120 of CA
All as per item No 33.00 but with following accessories a) Copper bus bar 200 Amps for 3 phase and Neutral b) MCCB TP 100 Amps 415 Volt 25 KA - 1 Nos c) MCB SPN 40 Amps, 10 KA 230 Volts - 5 Nos d) Space for Fixing 5 Nos of Single Phase Energy Meter of Capacity 40 Amps e) RYB Indicators - 1 Set (f) Digital VAF meter conforming to Cat No NEMFVIF00000 of HPL -01 No f) Taking down Existing energy meters and re fixing the energy meters at new panel Note - The lay out drawing of the panel shall be got approved by the contractor before panel fabrication and shall be CPRI approved factory fabricated of approved make specified vide Ser No 76 on Page No 120 of CA
Taking down copper/ aluminum point wiring (Light/Fan/Socket or power) complete including fixtures and fittings such as switches, ceiling roses, pendants, regulators, sockets light fitting etc. Removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces to walls floors etc complete all as specified and directed.
M & L for point wiring with FRLS PVC insulated unsheathed 1100 Volts grade single core multistranded copper conductor cable 1.5 Sqmm drawn in and including casing-caping and accessories, fixed on wall / ceiling etc with neccessary fixing accessories and earth continuity conductor cable of 1.5 Sqmm size connected to common earth and earth dolly including 2 mm thick pressed steel terminal boxes concealed in wall covered with laminated sheet top cover 3 mm thick for mounting switches / sockets / fan regulators fixed with Cadmium plated machine screws complete all as specified and directed for one light point controlled by one switch.
Supply & Fix switch piano single pole flush type 5A, 240 V one way complete all as specified and directed.
Supply & Fix Ceiling rose surface bakelite three terminal, 240 V. complete all as specified and directed
S&F in repair/replacement of building Security light fitting 30 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP65 protection and impact resistance of IK07 including fixing arrangements and taking down old rusted bracket fittings complete all as specified and directed. Make : Bajaj / Havells / Crompton.
M& L for bracket made out of GI pipe 32 mm dia Light grade, 1.2mtr long bent to shape with MS flat iron clamps made out of 40mmX 6mm thick FI nuts, bolts incl. taking down old rusted braket complete all as specified and directed.
Taking down carefully ceiling fan, exhaust fan, wall / pedestal fan of any make and any sweep and dismantling of blades canopy down rod etc & remove to store for repair. & refix the same including provision of 3 core 0.5 sq mm copper flexible cable from ceiling rose to connector. Note (i) The representative of the contractor shall report to Engineer-in-charge/JE on daily basis to carry out repairs to fan and the defects should be rectified on the same day
M&L for opening of body ceiling fan 1200 / 1400 mm sweep, cleaning of slots, rewinding of fan by super enameled copper insulated wire as per existing gauge, varnishing, heating assembling and testing complete all as directed by Engineer-in-Charge. Note - spares such as bearing, capacitor, capacitor clamp, rubber insulator will be measured seperately under respective item of this schedule
All as per ser item No 42.00 above but exhaust fan, Pedestal fan,wall fan, table fan of 300/400 mm Sweep.
All as per ser item No 42.00 above but exhaust fan, Pedastal fan,wall fan of 450/600 mm Sweep.
Painting only of ceiling fan, exhaust fan, wall fan, pedestal fan for any size and type, scraping out of old paint filling of cavities with filler preparation of body and cleaning of dust etc Painting by Spray with first Quality Paint including over coat of Zinc primer writing of MES number complete all as specified and directed.
Overhauling of Ceiling Fan, Exhaust Fan, Wall Fan, Table fan, Pedestal Fan any Make & any Sweep including dismantling/opening of body, cleaning of body, oiling, greasing & reassembling complete, replacing of split pin, nut , bolts etc and testing Note : Spares shall be measured & paid reparative item of this sch.
Supply only capacitor up to 2.5 Mfd for repairing fans in respective item, Make KELTRON,EPCOS
All as per ser item No 47.00 above but capacitor 3.15/ 4 Mfd.
All as per ser item No 47.00 above but capacitor clamp with connector as per sample
All as per ser item No 47.00 above but rubber Insulator sutiable for any type of ceiling fan.
All as per ser item No 47.00 above but mild steel down rod 600 mm long with clamp nut bolts & split pin as per sample
All as per ser item No 47.00 above but mild steel down rod with clamp nut bolts& split pin for 900 mm long as per sample
All as per ser item No 47.00 above but exhaust fan bracket with frame nut, bolt, rubbers etc complete for 300 mm sweep as per sample
All as per ser item No 47.00 above but exhaust fan bracket with frame nut, bolt, rubbers etc complete for 380/ 450 mm sweep as per sample
All as per ser item No 47.00 above but ball bearing sutiable for any type of fans Make : SKF,TATA,NBC
All as per ser item No 47.00 above but gun metal bush as per sample suitable for any type of fans
All as per ser item No 47.00 above but mild steel shaft as per sample for any fan
All as per ser item No 47.00 above but ceiling fan blade suitable for 1200/1400 mm sweep as per sample.
All as per ser item No 47.00 above but exhaust fan blade suitable for 300 mm sweep as per sample.
All as per ser item No 47.00 above but exhaust fan blade suitable for 450 mm sweep as per sample.
All as per ser item No 47.00 above but pedestal/ wall fan blade suitable for 450 mm sweep as per sample.
All as per ser item No 47.00 above but pedestal / wall fan blade suitable for 600 mm sweep as per sample.
Supply & fix exhaust fan louvers with shutter made of aluminium sheet of 0.5 mm thickness, and frames made out of mild steel, making good the disturbed surfaces in CM 1:4, including scaffolding if any required to carry out the work in building of height up to 32 Meters complete in all respects the
M & L for opening switch board mounting plate at any height and replacing of old unserviceable piano switch 5 Amps & refixing switch plate and testing complete all as specified and directed. Note (i) The representative of the contractor shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day
M & L for opening switch board mounting plate at any height and replacing of old unserviceable fan regulator & refixing switch plate and testing complete all as specified and directed. Note (i) The representative of the contractor shall report to Engineer-in-charge/JE and carry out repairs on daily basis be rectified on the same day
M & L taking down from position existing defective storage water heater 25 to 50 ltr storage Capacity for carrying out repairs work such as replacing worn out parts and fixing back in position in replacing the necessary nuts and bolts including disconnecting & reconnecting water & electric supply lines, testing, painting with two coats of white synthetic enameled paint by spray paint complete all as specified and directed
Supply only safety valve for geyser chromium plated brass 15 mm dia all as specified and directed Make :- Racold/ Bajaj
Supply only non return valve chromium plated brass 15 mm dia heavy-duty all as specified and directed Make :- Racold/ Bajaj
Supply only indicator lamp for geyser red/green, round/square/rectangle as per site requirement 230 V AC all as specified and directed
Supply only heating element 1500 watt threaded or push type as per the existing one suitable for vertical storage water heater of any size all as specified and directed.
Supply only heating element 2000 watt threaded or push type as per the existing one suitable for vertical storage water heater all as specified and directed.
Supply only thermostat suitable for storage water heaters 25 to 50 Ltrs capacity adjustable type i.e.. 0 degree centigrade to 80 degree centigrade all as specified and directed.
Supply and fix plug top 3 pin 15/16 Amps capacity.
Supply and fix in repairs cable flexible 3 core PVC insulated and pvc sheathed with multi stranded copper conductor size of 2.5 sqmm 1100 volts grade all as specified and directed.
Supply and fix in repair of copper water tank of 25 Ltrs capacity with and including necessary gasket packing, nuts, bolts, etc complete all as specified and directed.
Fabricating, supply and fixing in repair geyser bottom cover duly painted in two halves suitable for vertical type storage water 25/50 Ltrs capacity for geysers of any make as per the existing one all as specified and directed.
Supply & fix in repair flexible 15 mm dia PVC pipe for cold water of geyser with PTMT nuts on both ends of length 450mm with two washers all as specified and directed.
Supply & fix in repair flexible 15 mm dia PVC pipe for hot water of geyser with PTMT nuts on both ends of length 450mm with two washers, all as specified and directed
Supply and fixing in repairs Sheet Metal enclosure with 2 pin and earth plug and socket complete with one single pole MCB SP of Capacity upto 20 Amps 240 Volts all as specified and directed.
Supply and Laying or fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 50 Sqmm 3.5 core in trenches, along the wall including necessary connection and providing cable lugs as required including disconnection/taking down of existing unsvcable all as specified and directed. Note : A sum of Rs 1,05,853.00 towards sch of credit shall be deducted to arrive the contract sum.
AGRAWAL ASSOCIATES
Shree Ayyappa Engineering
Atharva Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .