Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.0 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.8 L+₹55,163.70 (1.89%)Rejected-Finance | L2 | Rejected-Finance Being other than lowest | |
| 3 | L3₹34.5 L+₹5.3 L (18.0%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L3 | Rejected-Finance Being other than lowest | |
| 4 | L4₹35.8 L+₹6.6 L (22.4%)Rejected-Finance RCP GURUDWARA ROAD WARD NO 29 SURATGARH SRI GANGANAGAR 335804 | SURATGARH | SRI GANGANAGAR | RAJASTHAN | 335804 | L4 | Rejected-Finance Being other than lowest | |
| 5 | L5₹39.2 L+₹10.0 L (34.0%)Rejected-Finance | L5 | Rejected-Finance Being other than lowest |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
22 Oct 2020, 6:00 pmClosed
GE (AF) E/M CHAKERI KANPUR
GE (AF) E/M CHAKERI KANPUR 208008
REPAIR REPLACEMENT AND MAINT OF LT PANELS AND OTHER WORKS AT DOMESTIC AREA OF AFS CHAKERI KANPUR
2020_MES_380479_1
8423/E8
Open Tender
Civil Works
Item Rate
274 days
GE (AF) E/M CHAKERI KANPUR
As per NIT
8 documents required · 8 mandatory
₹500
GE (AF) E/M CHAKERI
₹94,000
10 Nov 2020
24 Sept 2020
27 Oct 2020
24 Sept 2020
22 Oct 2020
8 Oct 2020
Amount
S&F in repair of MCCB 630 Amps 36 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers, etc. and dismantling of old MCCB testing and commissioning complete all as specified and directed. Make : L&T / Legrand / ABB
All as per Item No. 1 above but MCCB of capacity 400 Amps 36 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 250 Amps 36 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 200 Amps 36 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 160 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 125 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 100 Amps 25 KA, 4 Pole, 415V
All as per Item No. 1 above but MCCB of capacity 63 Amps 25 KA, 4 Pole, 415V
M&L for cleaning and servicing of ACBs of capacity 630-800 Amps, 50 KA, 4 Pole, 415V and other lugs accessories incl. nuts, bolts, washers etc. testing and commissioning complete all as specified and directed.
All as per Item No. 9 above but of capacity 1000 -1600 Amps, 50 KA, 415V, 4 Pole.
All as per Item No. 9 above but of capacity 2000 -2500 Amps, 60 KA, 415V, 4 Pole.
S&F in repair of ACB 1600 Amps 50 KA, 4 Pole, 415V including lugs, nuts, bolts, washers, spacers etc. and dismantling of old ACB testing and commissioning complete all as specified and directed. Make of ACB :- L&T / Legrand / ABB
All as per Item No. 12 above but ACB of capacity 1000 Amps 50 KA, 4 Pole, 415V
All as per Item No. 12 above but ACB of capacity 800 Amps 50 KA, 4 Pole, 415V
M&L for repair of Digital ammeter flush type 96 sqmm with suitable fixing arrangement and including suitable size of copper wound CTs for easily fixing in existing LT panel including necessary wiring complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
M&L for repair of Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
M&L for repair of Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
M&L for repair of CTs (current transformer) 250/400/630 Amps indoor type for existing LT panel complete all as specified and directed. Make : AE / L&T / Schenider or equivalent as approved by GE
Repair / Maintenance of LT Panel board by taking shut down, removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete by means of CRC-226 / Petrol tightening of all joints in bus bar, checking of earth and neutral voltage, removal of foreign objects, replacement of u/s nuts / bolts / washers including replacement of corroded glands, lugs, thimbles, hinges, doors locks, door knobs, gaskets etc. and tightening them properly for panels having I/O circuits upto 5 nos complete all as specified and directed.
All as per item no. 19 above but 6-8 no. of circuits.
All as per item no. 19 above but 9-12 no. of circuits.
S&F in repair of aluminium bus bar as per existing size, type and suitable for LT panel 415 Volt, AC including existing size / type insulator , proper taping / sleeving of bus bar and all accessories incl. nut, bolts, washers etc. complete all as specified and directed.
S&F in repair of On Load Change Over on wall / Panel 415 Volts 400 Amps capacity, 4 pole with Sheet steel enclosure complete all as specified and directed. Make - L&T / Havells / Schneider
All as per item no. 23 above but of capacity 200 Amps.
All as per item no. 23 above but of capacity 100 Amps.
All as per item no. 23 above but of capacity 63 Amps.
M&L for testing of old earthing using calibrated earth tester & submitting result to Engr-in-charge. Earthing that shows on higher side results as specified in IS rule and do not show continuity should be replaced with new earthing complete all as specified and directed. Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 5 Kg) shall be carried out one day prior to the testing & the cost of the same shall deemed to be included in unit rate quoted.
M&L for providing the MS plate size of size 200x150 mm of rectangular shape and not less than 1.6 mm thick fixed on angle iron 25x3 mm and 600mm height welded with plate and grouting vertically alongwith earthing pit with PCC (1:3:6 type C1) block not less than 300x300x300 mm duly painted background with black colour and writing with white colour Earthing Result in Ohm, date of testing, due date for testing complete all as specified and directed.
Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly to ground vertically to a depth not less than 2.25 Mtr below the ground level with top edge of earth plate not less than 1.5 Mtr below normal ground level connected to GI strip 32 x 6 mm size as earthing lead protected with 50 mm dia GI pipe light grade filling around with charcoal dust and salt including excavation, returning, filling of earth and disposal of surplus soil to a distance not exceeding 50 mtr and connected to GI strip by means of GI nuts, bolts and washers strip connected to earth plate including chamber PCC 1 : 3 : 6 type C1. using 20 mm graded stone aggregate in concrete pit pre-cast RCC 40 mm thick reinforced with 6 mm dia round at the rate of 75 mm C/C both way with 12 mm dia mild steel plain bar lifting handle 2 Nos funnel with wire mesh 20 mm dia GI pipe light grade watering pipe and frame work complete all as shown in electrical plate No. 3 of SSR Part - I including testing complete all as specified and directed. NOTE: GI strip upto 7.5 m length in included in unit rate quoted by contractor and beyond this lengths the same shall be measured & paid separately.
M&L for replacement of GI strip 32 x 6 mm by taking down the old existing earth strip any size inside hanger, fixing with proper clamp, saddles, nut bolts , washers etc. properly and connected to equipment or panel complete all as specified and directed.
M&L for removing old paint from the LT panels / Feeder Box by paint removers, cleaning by scrapping and preparing the surface and applying two coats of synthetic enameled paint of existing colour over a coat of red oxide primer using spraying machine and writing any description for panels having I/O circuits upto 4 nos complete all as specified and directed.
All as per item no. 31 above but 5-8 no. of circuits.
All as per item no. 31 above but 9-15 no. of circuits.
M & L for repair of End joint kit Heat shrinkable type suitable for 1100V XLPE under ground cable of size 70-150 sqmm 3.5 core Indoor/Outdoor type complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 34 above but of size 185-240 sqmm 3.5 core.
All as per item No. 34 above but of size 300-400 sqmm 3.5 core.
M & L for repair of Straight through joint kit Heat shrinkable type for 1100V XLPE under ground cable of size 70-150 sqmm 3.5 core complete all as specified and directed. Make: Raychem / 3M / Denson
All as per item No. 37 above but of size 185-240 sqmm 3.5 core.
Surface dressing 15 cm deep and getting out including cleaning away all grass vegetation saplings, brush wood under grouting, roots & tree and not exceeding 30 cm girth and removing rubbish to a distance of 50 mtr outside the periphery of area complete all as specified and directed.
Cutting / trimming of tree branches and creepers which are touching of overhead lines / pole and disposal of timber complete without dismantling of any item complete all as specified and directed.
M&L for re-routing of LT cables off sizes from 16sqmm to 400sqmm, 3.5/4 core including taking down in ducts/wall/floor/roof/trusses etc and re-alignment of LT cable, cutting/chassing in wall/duct and re-fixing in concealed position as per site requirment, including replacement of luggs, nut, bolts, washers, saddle clamp etc, including making good the disturbed surface to match with the existing surface complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and n. exc 1.5 m in depth for laying of cable for soft/ loose soil and getting out complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers n. exc 25 cm apart for soft/loose soil complete all as specified and directed.
M & L for dry Ganga Sand cushioning in trenches for protection of cable including watering and consolidation complete all as specified and directed. Note: Punned thickness shall be considerd for measurment purpose
Supplying and laying un-reinforced precast concrete cable cover, class HV type 1, flat, size 300mmx180mmx40mm complete all as specified and directed.
Removing of excavated surplus soil to a distance n. exc 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for cutting of PCC / Hard standing / WBM road not exceeding 30 cm in width & not exceeding 90 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material upto 15 cm in depth and 15 cm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate complete all as specified and directed.
M&L for making horizontal boring 90 cm deep below road crossing for passing of HT cable in GI pipe complete all as specified and directed.
Supply and laying in trenches/Floor or fixed to Pole/Wall in replacement GI pipe light grade of size 100 mm bore with fitting for protection of cable including dismantling existing pipecomplete all as specified and directed. Make :- Jindal / Tata / Prakash / Surya
Taking out from trenches/duct/floor/wall/roof/under road/drain or hardstanding etc. old existing underground XLPE aluminium conductor HT cable of size upto 240 sqmm 3 core for checking the serviceability of cables and making good the disturbed surface to original position complete all as specified and directed.
Supply Laying, testing and commissioning in repair of HT cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable (heavy duty) 11000 volts grade with stranded aluminium conductor of size 120 sq mm 3 core laid in trenches/duct / laid on wall etc. incl. suitable size lugs ,thimbles, glands, GI Nuts and bolts, washers, insulation tape etc. complete all as specified and directed. Make :- Havells / Polycab / Finolex
All as per item No 51 above but of size 185 Sqmm 3 core
M&L for detection of fault through fault locating high voltage mobile machine to locate the fault in underground cable by giving high voltage surge and to find out exact location of fault complete all as specified and directed. (Note : The Item includes transportation, fuel charges, charging of machine etc. for full functioning of machine upto detecting fault at a time. Bidder must quote rate considering the fact that it is solely his responsibility to arrange fault locating machine & shall not expect facilitation from the dept. for the same.)
M & L for repair of Straight through joint kit Heat shrinkable type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core all including testing complete all as specified and directed. Make: Raychem / 3M / Denson
M & L for repair of End termination joint kit Heat shrinkable Indoor type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core including testing complete all as specified and directed. Make: Raychem / 3M / Denson
M & L for repair of End termination joint kit Heat shrinkable Outdoor type with jointing material and accessories suitable for 11 KV HT XLPE armoured aluminium conductor cable of size 120-185 sqmm 3 core including testing complete all as specified and directed. Make: Raychem / 3M / Denson
Material and Labour for supply, installation, commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed:- Incoming: MCCB 250 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu Outgoing: MCCB 63 Amp, 25kA, 415V, 4P - 04 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation, commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 150 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed:- Incoming : MCCB 100 Amp, 25kA, 415V, 4P- 01 No, Ics=100% Icu Outgoing: MCCB 63 Amp, 25kA, 415V, 4P- 02 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation, commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 240 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed:- Incoming / Outgoing: MCCB 160 Amp, 25kA, 415V, 4P - 01 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation, commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, single door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 240 Amps on phase & neutral, dust and vermin proof, both side open with locking arrangement, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable complete all as specified and directed:- Incoming: MCCB 160 Amp, 25kA, 415V, 4P - 01 No, Ics=100% Icu Outgoing: (i) MCCB 125 Amp, 25kA, 415V, 4P - 02 No, Ics=100% Icu (ii) MCCB 63 Amp, 25kA, 415V, 4P - 02 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation,commissioning and testing in repair outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as specified and directed of suitable sizes for following :- (a) Incoming : (i) MCCB 250 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 63 Amp, 25kA, 415V, 4P- 03 No, Ics=100% Icu (ii) MCCB 100 Amp, 25kA, 415V, 4P - 01 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation,commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as specified and directed of suitable sizes for following :- (a) Incoming : (i) MCCB 400 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 250 Amp, 36kA, 4P, 415V - 02 No, Ics=100% Icu (ii) MCCB 100 Amp, 25kA, 4P, 415V - 01 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation,commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 400 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement comprising of multifunction meters with 3 lines LCD display of voltage, current and frequency and power factor of size 96x96 sqmm, suitable ratio CT, phase indicator-03 Sets, danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as specified and directed of suitable sizes for following :- (a) Incoming : (i) MCCB 250 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 100 Amp, 25kA, 4P, 415V - 03 No, Ics=100% Icu (ii) MCCB 63 Amp, 25kA, 4P, 415V - 02 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation, commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement with danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as specified and directed of suitable sizes for following :- (a) Incoming : (i) MCCB 400 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 250 Amp, 36kA, 4P, 415V - 02 No, Ics=100% Icu (ii) MCCB 100 Amp, 25kA, 4P, 415V - 02 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Material and Labour for supply, installation, commissioning and testing in repair of outdoor type LT panel (CPRI Approved) made out of 3.15 mm thick CRCA sheet metal, double door and suitable MS angle iron base frame, cubical type floor mounted 3 Phase, 4 Wire, 415 Volts properly insulated aluminium bus bar - 04 Nos having capacity 600 amps on phase & neutral, dust and vermin proof, both side open with locking arrangement with danger board plate, duly painted internally and externally with powder coated, fixing in position by provision of platform suitable size built with brick work in CM (1:4), 15 mm thick plastering in CM (1:6) including glands, lugs, thimbles for all incoming and outgoing cable including dismantling / taking out complete all as specified and directed of suitable sizes for following :- (a) Incoming : (i) Change Over 400 Amp, 415V, 3 phase - 01 No (ii) MCCB 250 Amp, 36kA, 415V, 4P - 01 No, Ics=100% Icu (b) Outgoing : (i) MCCB 63 Amp, 25kA, 4P, 415V - 02 No, Ics=100% Icu (ii) MCCB 100 Amp, 25kA, 4P, 415V - 02 No, Ics=100% Icu Make MCCB - L&T / Legrand / ABB
Taking out and reinstalling of LT switchgears / LT Panel to a distance not more than 5 kms from power house / substation / any place. Taking out/shifting/reinstalling and connecting including casting of suitable PCC foundation etc as per the requirement at site complete all as specified and directed.
M&L for fabrication of door/handles/side panels etc. For unserviceable / damaged / rusted LT panels at AFS Chakeri, Kanpur by using CRCA sheet 3.15 mm thick, serviced with hot gip galvanized seven tank process having ivory white color along with cast iron stand, name plate etc. complete all as specified and directed. Note : Material under this item will be paid separately under item 68 to 69.
Supply only CRCA sheet 3.15 mm thick, serviced with hot gip galvanized seven tank process having ivory white color complete all as specified and directed.
Supply only cast iron stand as required size painted in black color over a layer of red oxide primer complete all as specified and directed.
Attending breakdown attributable to cable faults, flashover in panels or any of the connected transmission system & rectifying it in 11kV / 1.1kV cable transmission line network upto end connections with panels or any of electrical item connected therein at Air Force station, Chakeri domestic and technical area during any hours of a day during the currency of contract by engaging sufficient manpower after receiving communication through Complaint Section / Concerned JE / Engr-in-charge either through teleponic call, text message, email or through messanger 24x7 hrs complete all as specified and directed. Note:- The occurance of fault if any, will be communicated to the contractor and the contractor shall rectify the same within 12 hrs of reporting, failing to which a recovery @ Rs 500/= per complaint per day and maximum of Rs. 10,000 /= per day shall be recovered from contractor's payment. Contractor shall be bound to arrange his resources accordingly and the quoted rates shall be deemed to include the same. Further, all necessary equipments like HT/LT megger, hand gloves, line testers , earth rod etc. shall be readily available with the contractor's manpower under his own arrangement. Delay on account of non availablity of such items shall not be considered for relaxation.
DUBEY TRADERS AND ENGINEERS
Bharat Sales Corporation
SRI SAI CONSTRUCTION COMPANY
S B ENTERPRISES
keerti trading corporation
Kumar Electricals
Gupta Constructions
Anandeshar Enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .