Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC | L1 | Accepted-AOC Accept | |
| 2 | L2₹39.6 L+₹3.1 L (8.39%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹40.7 L+₹4.1 L (11.3%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹46.0 L+₹9.4 L (25.7%)Rejected-Finance 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | krishna Associate L3 | M/S MAMTA CONSTRUCTIONS L2 | PD GUPTA AND COMPANY L4 | Sadhana Enterprises L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Repair/maintenance, excluding major spares but including regualr maintenance of the Automatic Power factor correction panel capacity up to 120 KVARs and up to12 stages installed at various locations including carrying out complete maintenance / repairs as required of all the sub systems viz. based control panels, feeder pillar, APFC relay, Power capacitor bank, Power contactors, Control wiring, Monitoring CT, MCBs/MCCBs for isolation (with all the accessoires) any breakdown maintenance and replacement of unserviceable parts, refixing of old serviceable parts/new parts if any project completion and trouble shooting responsibility also lies with contractor including following provisions complete all as specified.
Notes:-(i) Rate quoted by tenderer is deemed to be inclusive of checking of system, replacement of defective control wiring, small part such as Push button, lugs any auxilary contatct,auto selctor switch etc and necessary servicing repair. (ii) The scope of work includes the labour charges required for removing, repairing, refixing, carrying out electrical termination, capacitors bank, APFC relay, power contactor, contol CT, MCBs/MCCB and fixing/installing/testing and commissioning the complete system.
(iii) capacitors bank, APFC relay, power contactor, control CT, MCBs/MCCB shall be measured and paid saperatly | 12 | Each Job | 2,000 ₹24,000 | 2,000 ₹24,000 | 2,000 ₹24,000 | 250 ₹3,000 Lowest |
| 2.00 | S&F power factor correction capacitor, 5 KVAR, ultra heavy duty 440 volts 50 Hz complete all as specified. | 6 | Each | 1,200 ₹7,200 | 100 ₹600 Lowest | 500 ₹3,000 | 964 ₹5,784 |
| 3.00 | All as per item No 2 above but 10 KVAR Capactor Bank. | 5 | Each | 1,000 ₹5,000 | 150 ₹750 Lowest | 750 ₹3,750 | 1,928 ₹9,640 |
| 4.00 | All as per item No 2 above but 25 KVAR Capactor Bank. | 4 | Each | 1,000 ₹4,000 | 200 ₹800 Lowest | 1,000 ₹4,000 | 4,697 ₹18,788 |
| 5.00 | All as per item No 2 above but 50 KVAR Capactor Bank. | 3 | Each | 1,000 ₹3,000 | 250 ₹750 Lowest | 2,000 ₹6,000 | 9,100 ₹27,300 |
| 6.00 | Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised GI strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mm bore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length. | 10 | Each set | 4,000 ₹40,000 | 4,000 ₹40,000 | 4,000 ₹40,000 | 3,200 ₹32,000 Lowest |
| 7.00 | Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised GI wire of 4 mm dia by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 15 mm bore galvanised iron light grade for earth wire protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion.
Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length. | 5 | Each set | 4,000 ₹20,000 | 3,200 ₹16,000 Lowest | 3,600 ₹18,000 | 3,500 ₹17,500 |
| 8.00 | Material and labour for replacement of unserviciable existing earthing with bore well earthing with the help of mechanical boring machine of 150 mm dia-30 mtr depth supply and fix 160 mm dia (O.D), UPVC pipe 6 kg/sqcm rating -06 mtr long with the help of suitable size clamp with nut bolt and washer -01 No including charcoal dust ,salt fill in bore well for earth conductivity M&L for covering of bore well with PCC (1:2:4) type B-1 / Brick masonry pit of size 45x45x45 cm complete and give the minimum earth test result below 1 ohm complete all as specified.
Note :- (i) The earth pit shall be refilled by boulders free from vegetable soil.(ii) Earthing shall be tested by contractor in presence of Engr-in-charge.Record shall be maintained.Payment shall be admissible only after satisfactory test results. | 8 | Each | 15,000 ₹1,20,000 | 8,000 ₹64,000 Lowest | 10,000 ₹80,000 | 15,000 ₹1,20,000 |
| 9.00 | Supply & fixing in replacement of GI tubng 50 mm dia medium grade in incl necessary fittings for lowering in borewell of depth upto 30 mtr complete all as specified. | 250 | RM | 450 ₹1,12,500 | 500 ₹1,25,000 | 300 ₹75,000 | 250 ₹62,500 Lowest |
| 10.00 | Supply in repair MCCB 63 Amp, 4 Pole, fixed type breaking capacity 16 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified. | 4 | Each | 2,000 ₹8,000 Lowest | 2,900 ₹11,600 | 4,000 ₹16,000 | 2,800 ₹11,200 |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
8 Aug 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Bharatpur
GE Bharatpur
REPAIR MAINTENANCE OF CERTAIN E M AND B R WORKS OF MES INSTALLATIONS AT MES SUB STN AT 39 FAD DAYAL BAGH MES IB AND KANJOLI LINE AREA AT BHARATPUR
2025_MES_719946_1
8499/E8
Open Tender
Civil Works
Item Rate
180 days
GE Bharatpur
AS PER NIT
8 documents required · 8 mandatory
₹500
Yes
GE Bharatpur
₹98,000
Yes
17 Nov 2025
11 Jul 2025
11 Aug 2025
11 Jul 2025
8 Aug 2025
25 Jul 2025
11 Jul 2025 - 24 Jul 2025
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .