Loading…
Loading…
Tender Value
₹2.4 Cr
EMD Value
₹2.4 L
Closing Date
29 Aug 2026, 11:00 am6d left
Repair and Retrofitting works including Civil, Plumbing and Electrical works etc
NSL/CEO/KV/NIT/2026/933
NSL/CEO/KV/NIT/2026/933
Open Tender-Domestic
Miscellaneous
Gurugram, Haryana
₹11,800
₹2.4 L
21 Aug 2026
21 Aug 2026
29 Aug 2026
29 Aug 2026
S.No. Description of Works Amount (DSR in Rs.)
2 Plumbing Works 1,130,157.04 784,583.21
3 Electrical Works 2,513,428.00 676,535.88
TOTAL COST OF WORK 18,928,998.66 5,276,748.41
TOTAL COST INCLUDING GST 24,205,747.00
Digitally signed by MANISH
Sl No DSR No Description of Item Unit Quantity DSR rate 2025 Amount(Rs) Amount(Rs)
Excavating trenches of required width for pipes, cables, etc including excavation for
sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m, including
getting out the excavated soil, and then returning the soil as required, in layers not
1.0 2.10 exceeding 20 cm in depth, including consolidating each deposited layer by
ramming, watering, etc. and disposing of surplus excavated soil as directed, within a
2.10.1 All kinds of soil
2.10.1.3 Pipes, cables etc. exceeding 300 mm dia but not exceeding 600 mm metre 50.00 549.75 27487.50
Providing and laying in position ready mixed or site batched designmix cement
concrete for plain cement concrete work; using coarseaggregate and fine
aggregate derived from natural sources and using recycled concrete aggregate
(RCA) as coarse aggregate and fine aggregate within the permissible utilization,
Portland Pozzolana / Ordinary Portland/Portland Slag cement, admixtures in
recommended proportions as per IS: 9103 to accelerate / retard setting of
concreteto improve durability and workability without impairing strength;including
pumping of concrete to site of laying, curing, carriage for all leads; but excluding the
cost of centering, shuttering and finishing as per direction of the engineer-in-charge;
for the following grades ofconcrete.
4.20.1 All works upto plinth level :
M-15 grade plain cement concrete (cement content considered @ 240 kg/cum)
All works above plinth and upto floor V level
3.0 4.20A.2.1 Concrete of M10 grade with minimum cement content of 220 kg /cum Cum 4.00 8291.75 33167.00
Providing and laying in position specified grade of reinforced cementconcrete,
excluding the cost of centering, shuttering, finishing and reinforcement - All work up
to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm
Reinforced cement concrete work in beams, suspended floors, roofs having
slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills,
staircases and spiral stair cases up to floor five level excluding the cost of centering,
shuttering, finishing and reinforcement, with 1:2:4 (1 cement : 2 coarse sand : 4
graded stone aggregate 20 mm nominal size).
Digitally signed by MANISH
6.0 Centering and shuttering including strutting, propping etc. and removal of form for :
5.9.5 Lintels, beams, plinth beams, girders, bressumers and cantilevers SQM 180.00 608.35 109503.00
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing
in position and binding all complete upto plinth level.
5.22.1 Mild steel and Medium Tensile steel bars Kg 1200.00 107.10 128520.00
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation
7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) Cum 14.00 9344.35 130820.90
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded
and prepolished, machine cut for kitchen platforms, vanity counters, window sills,
facias and similar locations of required size, approved shade, colour and texture
laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints
9.0 8.2 treated with white cement, mixed with matching pigment, epoxy touch ups,
including rubbing, curing, moulding and polishing to edges to give high gloss finish
etc. complete at all levels
8.2.2 Granite stone slab colour black, Cherry/Ruby red Sqm 250.00 5413.50 1353375.00
Providing edge moulding to 18 mm thick marble stone counters, Vanitiesetc.,
10.0 8.3 including machine polishing to edge to give high gloss finish etc. complete as per
design approved by Engineer-in-Charge.
8.3.2 Granite work metre meter 150.00 510.95 76642.50
TILE DADO :- Providing and fixing Ist quality ceramic glazed wall tiles
conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved
make, in all colours, shades except burgundy, bottle green, black of any size as
approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm
thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey
11.0 8.31 cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with SQM 800.00 1267.95 1014360.00
pigment of matching shade complete.
Providing wood work in frames of doors, windows, clerestory windows and other
frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners
12.0 9.1.1 of required dia & length (hold fast lugs or dash fastener shall be paid for separately). cum 2.00 142949.70 285899.40
Second class teak wood
Digitally signed by MANISH
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm
hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with
spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required
spacing near opening, with necessary welding at junctions and fixing the frame to
wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including
13.0 9.1.2 making provision for opening for doors, windows, electrical conduits, switch boards kg 1030.79 124.50 128333.36
etc., including providing with two coats of approved steel primer etc. complete, all
as per direction of Engineer-in-charge
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
decorative type, core of block board construction with frame of 1st class hard wood
and well matched teak three ply veneering with vertical grains or crossbands and
14.0 9.20.1 face veneers on both faces of shutters.35 mm thick Fixing with hinges of required size Sqm 40.00 3473.85 138954.00
and necessary screws (Note: Hinges and necessary screws hall be paid separately
Providing and fixing bright finished brass 100 mm mortice latch with one dead bolt
and a pair of lever handles of approved quality with necessary screws etc.
Providing and fixing aluminium die cast body tubular type universal hydraulic door
closer (having brand logo with ISI, IS : 3564, embossedon the body, door weight upto
16.0 9.83 35 kg and door width upto 700 mm), withnecessary accessories and screws etc. Each 30.00 1124.85 33745.50
Providing & fixing glass panes with putty and glazing clips in steel doors, windows,
clerestory windows, all complete with :
10.3.1 4.0 mm thick glass panes Sq mt 200.00 1505.25 301050.00
5.5 mm thick glass panes
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured
from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock
jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm,
or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by
18.0 10.14 mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar
guards, lock strike-plate and shock absorbers as specified and applying a coat of
approved steel primer after pre-treatment of the surface as directed by Engineer-in-
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid
Steel work welded in built up sections / framed work, including cutting, hoisting, fixing
in position and applying a priming coat of approved steel
primer using structural steel etc. as required.
Digitally signed by MANISH
10.25.2 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with
grey cement slurry mixed with pigment to match the shade of the slab, including
20.0 11.26 rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4
Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate) finished with a floating coat of neat cement, including cement
21.0 11.3 slurry, but excluding the cost of nosing of steps etc. complete.
11.3.1 40 mm thick with 20 mm nominal size stone aggregate sqm 1100.00 614.20 675620.00
Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more
(thickness to be specified by the manufacturer), of 1st quality conforming to IS :
15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume
Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand),
23.0 11.40 jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with Sqm 550.00 1225.10 673805.00
white cement and matching pigments etc., complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by
the manufacturer) with water absorption less than 0.08%and conforming to IS :
15622 , of approved make, in all colours and shades, laid on 20mm thick cement
22.0 11.41 mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3kg/sqm
including grouting the joints with white cement and matching pigments
Size of Tile 600x600 mm
Providing and laying flamed finish Granite stone flooring in required design and
patterns, in linear as well as curvilinear portions of the building all complete as per the
architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base
of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with
24.0 11.55 cement slurry and pointing with white cement slurry admixed with pigment of
matching shade including rubbing, curing and polishing etc. all complete as
specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or
Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of 5
m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in
between and reinforced with rabbit wire mesh fixed to wooden frame (frame work to
be paid separately):
Digitally signed by MANISH
Extra for sunk or raised mouldings in the plaster of Paris (Gypsum anhydrous)
Providing and fixing false ceiling at all height including providing and fixing of frame
work made of special sections, power pressed from M.S. sheets and galvanized with
zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of
angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at
1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm
dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers
of 25x10x0.50 mm of required length with nuts & bolts of required size and other end
of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the
spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick
bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5
mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I.
intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long
G.I.wire at every junction, including fixing perimeter channels 0.5 mmthick 27 mm
27.0 12.45 high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to
wall/partition with the help of rawl plugsat 450 mm centre, with 25mm long dry wall
screws @ 230 mm interval, including fixing of gypsum board to ceiling section and
perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c,
including jointing and finishing to a flush finish of tapered and square edges of the
board with recommended jointing compound , jointing tapes , finishing with jointing
compound in 3 layers covering upto 150 mm on both sides of joint and two coats of
primer suitable for board, all as per manufacturer's specification and also including
the cost of making openings for light fittings, grills, diffusers, cutouts made with frame
of perimeter channels suitably fixed, all complete as per drawings, specification and
direction of the Engineer in Charge but excluding the cost of painting with :
12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011
certification marks)
Extra for plastering exterior walls of height more than 10 m from ground level for every
additional height of 3 m or part thereof.
PRIMER: Applying one coat of water thinnable cement primer of approved brand
and manufacture on wall surface. Water thinnable cement primer.
Applying priming coats with primer of approved brand and manufacture, having low
VOC (Volatile Organic Compound ) content.
Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or
more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior
primer applied @ 2.20 kg/10 sqm)
Digitally signed by MANISH
31.0 13.2 15 mm cement plaster on the rough side of single or half brick wall of mix :
32.0 13.6 20 mm cement plaster of mix :
13.61 Painting with synthetic enamel paint of approved brand and manufacture
33.0 to give an even shade: SQM 250.00 131.45 32862.50
13.61.1 Two or more coats on new work
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic
Compound ) content less than 50 grams/ litre, of approved brand and manufacture,
34.0 13.81 including applying additional coats wherever
required, to achieve even shade and colour.
13.81.2 old work (one or more coats ) Sqm 1800.00 62.70 112860.00
Wall painting with acrylic emulsion paint, having VOC content less that 50 grams /
litre, of approved brand and manufacture, including appliying additional coats
13.82 wherever required, to achive even shade and colour: Two coat
Providing and applying white cement based putty of average thickness 1 mm,
of approved brand and manufacturer, over the plastered wall surface to
35.0 13.80 prepare the surface even and smooth complete. (Internal Walls) Sqm 1350.00 156.05 210667.50
Applying priming coats with primer of approved brand and manufacture, having low
36.0 13.85 VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50
Removing dry or oil bound distemper, water proofing cement paint and the like by
37.0 13.91 scrapping, sand papering and preparing the surface smooth including necessary Sqm 1800.00 25.15 45270.00
repairs to scratches etc. complete.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including
38.0 15.12 chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead :
15.12.1 Of area 3 sq. metres and below No. 35.00 367.20 12852.00
Dismantling tile work in floors and roofs laid in cement mortar including stacking
material within 50 metres lead
15.23.1 15.23.1 For thickness of tiles 10 mm to 25 mm Sq mt 250.00 73.40 18350.00
Dismantling C.I. pipes including excavation and refilling trenches after taking out the
pipes, manually/ by mechanical means breaking lead caulked joints, melting of
40.0 15.45 lead and making into blocks including stacking of pipes & lead at site within 50
metre lead as per direction of Engineer-in-charge:
Demolishing cement concrete manually/ by mechanical means including disposal of
41.0 15.2 material within 50 metres lead as per direction of Engineer - in - charge.
15.2.1 Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) Cum 12.00 2434.25 29211.00
Digitally signed by MANISH
Dismantling stone slab flooring laid in cement mortar including stacking of
42.0 15.25 serviceable material and disposal of unserviceable material within 50 metres lead Sqm 150.00 266.45 39967.50
Dismantling asbestos cement pressure pipes including excavation and refilling
trenches after taking out the pipes manually/ by mechanical means and stacking
43.0 15.47 the pipes within 50 metres lead as per direction of Engineer-in-charge :
Dismantling of flushing cistern of all types (C.I./PVC/Vitreous China) including
44.0 15.52 stacking of useful materials near the site and disposal of unserviceable materials No. 50.00 112.05 5602.50
within 50 metres lead.
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster
45.0 15.56 including disposal of rubbish to the dumping ground within 50 metres lead. Sqm 1500.00 54.65 81975.00
Demolishing R.C.C. work by mechanical means and stockpiling at designated
locations and disposal of dismantled materials up to a lead of 1 kilometre, stacking
46.0 15.58 serviceable and unserviceable material separately including cutting reinforcement Cum 7.00 2818.90 19732.30
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste
materials by mechanical means, including loading, transporting, unloading to
47.0 15.60 approved municipal dumping ground or as approved by Engineer-in-charge, Cum 250.00 263.95 65987.50
beyond 50 m initial lead, for all leads including all lifts involved.
Demolishing brick work manually/ by mechanical means including stacking of
48.0 15.7 serviceable material and disposal of unserviceable material within 50 metres lead as
per direction of Engineer-in-charge..
15.7.4 In cement mortar (One side Boundary wall) Cum 10.00 2060.20 20602.00
Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/Brick/
Stone/ wood/ Ceramic/ Gypsum work by providingweather/structural non sag
elastomeric PU sealant over backer rodof approved quality as per architectural
49 21.19 drawings and direction ofEngineer-in-charge complete, complying to ASTM C920,
DIN 18540 F & ISO 11600
21.19.3 Upto 20 mm depth and 20 mm width meter 100.00 308.70 30870.00
Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels /
subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral
crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral
crystalline slurry : 1 part water) for horizontal surfaces and applying the same from
50.0 22.23 negative (internal) side with the help of synthetic fiber brush. The material shall
meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as
per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The
crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm.
The work shall be carried out all complete as per specification and the direction of
the engineer-in-charge. The product performance shall carry guarantee for 10
years against any leakage.
22.23.1 For vertical surface two coats @ 0.70 kg per sqm sqm 500.00 472.90 236450.00
Digitally signed by MANISH
22.23.2 For horizontal surface one coat @1.10 kg per sqm. sqm 500.00 362.80 181400.00
Star Eniroof EMB/SPR/ or Star Proof WF MB/ SP Waterproofing Treatment. Cleaning of
surface by blower / wire brush and repairing of Minor cracks, with chemical of
Zycoprime Plus (Bonding Agent) admix with cement sand motar as required area and
then providing if required according to surface and Making Zycoprime Base & then
Applying, 1 coat of Star Eniroof EMB/SPR/ Star Proof WF/SP Black & White Making
primer admix with Water According to Star Recommendation or our Requirements
according to Surface and then applying Again 1 coat of Star Eniroof EMB/SPR/ Star
Proof WF/SP Black & White Star Recommendation or our Requirements according to
Surface with Water & Last Final 1 Coat of Star Eniroof EMB/SPR/ Star Proof WF/SP
Black & White Final work. (Total 3 Coat work only) Chemical Detail : (Star Eniroof EMB
Star Eniroof EMB highly Elastomeric Pitch Free Waterproofing Coating & High Solid UV
Resistant Acrylic Waterproofing membrane and heat reflector Coating System with
Elongation upto 200%.
Chemical Detail : (Zydex (Zycoprime plus + )
Zycoprime plus + is an Acrylic Co-polymer with Nanotechnology Emulsion Acts as a
Bonding agent for Cement modified Cementitious composite system.
Providing and fixing double scaffolding system (cup lock type) on the exterior side of
building/structure, up to 25 metre height, above ground level, including
additional rows of scaffolding in stepped manner as per requirement of site, made
with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical
tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and
52.0 24.2 staircase system in the scaffolding for working platform etc. and maintaining it in a
serviceable condition for execution of work of cleaning and/ or pointing and/ or
applying chemical and removing it thereafter.
The scaffolding system shall be stiffened with bracings, runners, connecting with the
building etc, wherever required, if feasible, for inspection of work at required
locations with essential safety features for the workmen etc., complete as per
directions and approval of Engineer-in-charge.
Note :- (1) The elevational area of the scaffolding shall be measured for payment
(2) The payment will be made once only for execution of all items for such works.
Chipping of unsound/weak concrete material from slabs, beams, columns etc. with
manual Chisel and/ or by standard power driven percussion type or of approved
make including tapering of all edges, making square shoulders of cavities
53.0 26.28 including cleaning the exposed concrete surface and reinforcement with wire
brushes etc. and disposal of debris for all lead and lifts all complete as per direction
of Engineer-In-Charge
Digitally signed by MANISH
26.28.2 50mm average thickness Sqm 600.00 256.35 153810.00
Providing, mixing and applying bonding coat of approved adhesive on chipped
54 26.31 portion of RCC as per specifications and direction of Engineer-In-charge complete in
SBR Polymer (@10% of cement weight) modified cementitious bond coat @ 2.2 kg
26.31.1 cement per sqm of surface area mixed with specified proportion of approved Sqm 500.00 141.20 70600.00
Epoxy bonding adhesive having coverage 2.20 sqm/kg of approved make
Providing and injecting approved grout in proportion recommended by the
manufacturer into cracks/honey-comb area of concrete/ masonry by suitable
gun/pump at required pressure including cutting of nipples after curing etc.
55.0 26.35 complete as per directions of Engineer-in- Charge. (The payment shall be made on
the basis of actual weight of approved grout injected.)
26.35.3 Epoxy injection grout in concrete/RCC work of approved make KG 600.00 553.40 332040.00
Providing, erecting, maintaining and removing temporary protective screens made
out of specified fabric with all necessary fixing arrangement to ensure that it
56.0 26.36 remains in position for the work duration as required by the Engineer-in-charge.
26.36.1 Wooven PVC cloth sqm 1200.00 54.25 65100.00
Cleaning of exposed concrete surface of sticking material including loose and
foreign material by sand blasting with coarse sand followedby and including
57.0 26.37 cleaning with oil free air blast as per direction of Engineer in charge. sqm 600.00 382.40 229440.00
Shotcreting R.C.C. columns, beams and slabs etc. in layers with approved design mix
concrete having the specified minimum characteristic compressive strength [with
ordinary portland cement, coarse sand and graded stone aggregate of 10 mm
maximum size in proportion as per design criteria] including the cost of
centering and shuttering at edges and corners etc. as directed by Engineerin-
Charge Note: Rates shall include the providing necessary ground wires etc. The
levelling gauges, if used, shall be paid for separately. Paymentunder this item shall be
made only after proper wet curing has been done and surface has been
satisfactorily evaluated by sounding/ tapping with a blunt metal instrument.
50mm thick in Grade M 25 with cement content not less than 330 kg per cum
Providing and inserting 12mm dia galvanised steel injection nipple in honey comb
area and along crack line including drilling of holes of required diametre (20mm to
30mm) up to depth from 30mm to 80mm at required spacing and making the hole &
60.0 26.39 crack dust free by blowing compressed air, sealing the distance between 50 450.00 236.90 106605.00
injection nipple with adhesive chemical of approved make and allow it to cure
complete as per direction of Engineer-In-Charge.
61.0 26.40 This item shall be payable only where temporary propping/shoring is specifically approved
sqmby the900.00
Engineer-in-Charge
902.55 for structural safety during repair and rehabilitation works. Ordinary scaffol
Digitally signed by MANISH
Providing, fabricating, erecting, maintaining and dismantling temporary
propping/shoring system using adjustable steel props, structural steel sections,
channels, beams, timber packing, wedges, base plates, sole plates, bracing and all
necessary accessories to safely support and relieve loads from RCC beams, slabs or
other structural members during demolition, concrete removal, reinforcement
replacement and structural repairs. The work shall include design of the propping
arrangement, erection, periodic inspection, maintenance for a period up to 30 days,
dismantling after completion of repairs and removal of all materials from site,
71.0 MR complete as directed by the Engineer-in-Charge.This item shall be payable only Sqm 350.00 810.00 283500.00
where temporary propping/shoring is specifically approved by the Engineer-in-
Charge for structural safety during repair and rehabilitation works. Ordinary
scaffolding, staging and temporary supports required for execution of standard DSR
items shall be deemed included in the respective item rates and shall not be
measured or paid separately.
Providing and applying anti-corrosive treatment to exposed reinforcement by
thoroughly cleaning the steel reinforcement using wire brush, mechanical brushing or
light abrasive blasting to remove rust, scale and loose particles, followed by
application of two coats of epoxy zinc-rich primer/passivating coating compatible
with the repair mortar system. The work shall include surface preparation, cleaning, Sqm 100.00 720.00 72000.00
application of primer, curing wherever required, and all materials, labour, tools,
tackles, equipment and incidentals complete as per the manufacturer's
specifications and directions of the Engineer-in-Charge.
Providing and applying bi-polar migratory corrosion inhibitor on prepared concrete
surfaces for corrosion protection of embedded reinforcement. The corrosion inhibitor
shall be water-based, penetrating type, capable of migrating through concrete
pores to a depth of up to 100 mm to form a protective molecular layer on
embedded steel reinforcement, thereby reducing corrosion caused by carbonation
and chloride ingress. The work shall include surface cleaning, application by brush,
roller or low-pressure spray in the manufacturer's recommended number of coats
and coverage, curing wherever required, and all materials, labour, tools, equipment
and incidentals complete as per the manufacturer's specifications and directions of
the Engineer-in-Charge.
Providing and fixing embedded galvanic sacrificial zinc anodes conforming to ASTM
B418 Type II, consisting of minimum 100 g high-purity zinc encased in a conductive
cementitious mortar, complete with factory-attached tie wires for electrical
connection to cleaned reinforcing steel. The work shall include soaking the anodes in
clean water before installation, tying the anodes securely to the exposed
reinforcement in the specified grid pattern, ensuring proper electrical continuity with
reinforcement, embedding in approved repair mortar, and completing the
installation as per the manufacturer's recommendations and directions of the
Engineer-in-Charge, including all materials, labour, tools, accessories, testing and
incidental works.
Digitally signed by MANISH
Providing, fixing, testing and commissioning galvanic sacrificial cathodic protection
system comprising strip type zinc sacrificial anodes for corrosion protection of
embedded steel reinforcement in RCC members affected by chloride ingress. The
zinc strip anodes shall conform to ASTM B418 Type II and shall consist of high purity
zinc core encapsulated in an alkaline activating mortar having pH greater than 14,
free from chlorides, bromides and other corrosive constituents as per ACI 222R
recommendations. The anode shall be provided with stainless steel connection wires
for electrical continuity with reinforcement and protective PVC mesh/cover as
recommended by the manufacturer. The work shall include exposing reinforcement
wherever required, cleaning reinforcement, electrical connection to steel
reinforcement, installation of zinc strip anodes in low resistivity activation mortar,
continuity testing, reinstatement with approved repair mortar, monitoring,
commissioning, all accessories, labour, tools & tackles, design calculations for anode
spacing, installation training and complete as per manufacturer's specifications and
directions of Engineer-in-Charge.
Nozzle Insertion for Grouting : Providing and inserting 12mm dia galvanised steel
injection nipple in honey comb area and along crack line including drilling of holes of
required diametre (20mm to 30mm) up to depth from 30mm to 80mm at required
76.0 26.39 spacing and making the hole & crack dust free by blowing compressed air, sealing kg 700.00 236.90 165830.00
the distance between injection nipple with adhesive chemical of approved make
and allow it to cure complete as per direction of Engineer-In-Charge
Injection Grouting :
Providing and injecting approved grout in proportion recommended by the
manufacturer into cracks/honey-comb area of concrete/masonry by suitable
gun/pump at required pressure including cutting of nipples after curing etc.
26.35 complete as per directions of Engineer-in-Charge.
Cementitious Grouting :
Stirrer mixed Acylic Polymer (of approved make @ 2% of weight of Cement used)
26.35.1 Modified Cement Slurry made with Non-Shrink Compound in Concrete / RCC work Kg 300.00 119.30 35790.00
Epoxy Grouting :
Epoxy injection grout in concrete/RCC work
Digitally signed by MANISH
Surface Preparation for Waterproofing over Existing Toilet Floor:
Preparing the existing PCC/RCC surface for application of waterproofing treatment
by removing dust, dirt, laitance, oil, grease, loose particles and other contaminants
using compressed air, industrial vacuum cleaner or other approved mechanical
means, grinding and dressing the surface to remove irregularities, projections and
sharp edges, repairing minor surface defects, honeycombs and undulations with
77.0 MR approved polymer modified repair mortar, ensuring a clean, sound, smooth and dry Sqm 378.00 190.00 71820.00
substrate suitable for application of waterproofing system, complete in accordance
with the manufacturer's specifications and the directions of the Engineer-in-Charge.
Providing and Applying Hybrid Polyurethane Waterproofing Coating:
Providing and applying seamless Hybrid Polyurethane (PU) waterproofing coating
system over prepared concrete/plastered surfaces comprising thorough cleaning of
the surface, repairing minor surface defects wherever required, application of one
coat of compatible acrylic primer, followed by three coats of Hybrid Polyurethane
waterproofing coating by brush/roller application at a minimum total consumption of
1.20 kg/sqm to achieve a minimum dry film thickness of 0.70 mm, complete as per
the manufacturer's specifications and the directions of the Engineer-in-Charge.
The coating shall have minimum elongation of 500%, minimum tensile strength of 1.5
MPa, excellent crack-bridging ability, UV resistance, weather resistance and
waterproofing performance. The rate shall include surface preparation, primer,
waterproofing coating, labour, tools & plants, scaffolding wherever required, curing,
all leads and lifts and all incidental works complete.
Filling of Pipe Cavities :
Providing and applying, high precision non shrink cement based flowable, two
stage expanding grout complying to ASTM C 1107 and having following physical
properties: bulk density ~1.5 kg/l at 27°C; Compressive Strength at ambient
temperature of +30°C according to ASTM 1107 in 1 day ~25 N/mm2, in 3 days
~35 N/mm2, in 7 days ~55 N/mm2 and in 28 days ~65 N/mm2; Flexural Strength
79.0 MR at ambient temperature of +30°C according to ASTM C 293 in 7 days ~7 N/mm2 Each 100.00 640.00 64000.00
and in 28 days ~9 N/mm2; E-Modulus ~37,000 N/mm2. The manufacturer must be
an ISO 9001 & 14001 certified and valid certificates must be produced as
Digitally signed by MANISH
Supply and apply solvent free, moisture insensitive epoxy resin based patch
repair putty on pipe penetration surfaces. The putty shall be applied to a thickness
of minimum 20mm on pipe penetration joint to concrete approved make.
80.0 MR Yield: 0.6 ltr/kg. Product requirements: suitable for submerged condition; Each 240.00 1190.00 285600.00
compressive strength of 40 N/mm2 (1 day) according to IS 9162-1979.
For Shear Connector/Ties/Stirrups: Supply and fixing of shear connectors/ties/stirrups
using rebars of designated dia for column/beam/Shear walls etc at designed
embedement length wherever required , including power drilling, cleaning of holes,
then rebars should be inserted in holes that should be filled with FIS V Plus of Fischer
or equivalent, a hybrid rebarring chemical with ETA approval, DIBt, approved for
diameter range from 8 mm to 28mm reinforcement bar as per manufacturer's
specification as per the direction of Engg In-charge. Drilling of hole should be done
upto provided embedment depth as per the design from manufacturer approved by
EnC, followed by cleaning with blow pump, wire brush and blow pump for 4 times,
complete as per the manufacturer's methodology. The chemical shall have tested
service life of 50years as per ETA. Cost of providing, cutting, bending of rebar shall be
paid separately as per approved item.
Rebar For Main Reinforcement: Supply and fixing of main reinforcement using rebars
of designated dia for column/beam/Shear walls/Foundations at designed
embedement length wherever required , including power drilling, cleaning of holes,
then rebars should be inserted in holes that should be filled with FIS EM Plus of Fischer
or equivalent, a heavy duty pure epoxy based rebarring chemical with ETA approval,
DIBt, approved for diameter range from 8 mm to 40 mm reinforcement bar as per
manufacturer's specification as per the direction of Engg In-charge. Drilling of hole
82 MR should be done upto provided embedment depth as per the design from
manufacturer approved by EnC, followed by cleaning with blow pump, wire brush
and blow pump for 4 times, complete as per the manufacturer's methodology. The
chemical shall be approved for diamond-drilled and water-filled drill holes as well as
seismic applications in performance categories C1, C2 for rebar connections.
Product shall have test certificate for 120years of service life & shall have ETA
complying to EAD 332402-00-0601-v01. Cost of providing, cutting, bending of rebar
shall be paid separately as per approved item.
Digitally signed by MANISH
Microconcrete with 6mm aggregaates : Application of repair Micro concrete of
minimum M40 grade with 25% aggregate of 6mm dia. of approved make for
making up lost section of concrete or for increasing of cross section for thickness
above 75 mm, after the application of bonding agents to ensure stability of the
concrete, followed by water curing for at least 7 days. The rates are inclusive
of all materials, labor, machinery, equipment, tools, tackles, etc., all
complete.The microconcrete shall be free flow, self compacting & should
83.0 MR not require any vibratory compaction.Payment shall be made on the basis Kg 1670.00 92.50 154475.00
of consumed dry material of microconcrete and payment for bonding agents will
be done through separate BOQ item. The cost chips is considered to
included in the item rate.
Repair Micro concrete: Application of repair Micro-concrete of M40 grade for Making
up lost section of concrete for thickness more than 30mm, after the application of
bonding agents to ensure stability of the concrete, followed by curing with water for
84.0 MR at least 7 days. The rates are inclusive of all materials, labour, machinery, equipment, Kg 1050.00 71.98 75579.00
Providing and applying up to 25 mm thick double coat Ready Mix Cement Plaster on
external walls, soffits, beams, columns and other exposed RCC/masonry surfaces,
comprising a minimum 20 mm average thickness finished in two coats, using factory
manufactured ready-mix cement plaster of approved make conforming to relevant
IS standards, mixed with approved integral waterproofing compound and
polypropylene fibres as recommended by the manufacturer. The work shall include
preparation of the surface by removing loose mortar, hacking RCC surfaces
wherever required, cleaning, wetting, applying approved polymer modified bonding
agent on RCC surfaces followed by a scratch coat to ensure proper adhesion. The
item shall also include treatment of RCC and masonry junctions by raking out joints,
88.0 MR filling with approved non-shrink polymer modified grout, fixing 150 mm wide alkali- Sqm 300.00 1480.00 444000.00
resistant PVC/Fiberglass mesh centred over the junction before plastering. The plaster
shall be applied in two coats to achieve the required thickness, true line, level and
plumb, finished with sand-faced texture or as directed by the Engineer-in-Charge
suitable to receive architectural external finish.
Digitally signed by MANISH
Rebuilding the section of structutal damaged RCC elements to its original size or as
per consultants recommendations in thickness up to 25mm in 2 layers of 10 mm and
15mm each by providing and applying with pre-batched, one component fiber
reinforced cementitious patch repair mortar. Dual Shrinkage expansion, fibre
93.0 MR reinforced, single component, polymer modified, cementitious, repair mortar Sqm 250.00 3350.00 837500.00
system supplied as a ready to use blend of dry powders, which requires only
the addition of clean water to produce a highly consistent, repair mortar
suitable for structural concrete and masonry repairs. Make SIKA, Fosroc or
equivalent. complete as per direction of Engineer-in-charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including
94 15.12 chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:
15.12.2 Of area beyond 3 sq. metres Each 22.00 502.75 11060.50
DOOR FRAMES- Providing wood work in frames of doors, windows, clerestory windows
and other frames, wrought framed and fixed in position with hold fast lugs or with
95 9.1 dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid
9.1.1 Second class teak wood CUM 1.05 142949.70 150097.19
FLUSH DOOR:- Providing and fixing ISI marked flush door shutters conforming to IS :
2202 (Part I) non-decorative type, core of block board construction with frame of 1st
class hard wood and well matched commercial 3 ply veneering with vertical grains
or cross bands and face veneers on both faces of shutters :
9.21.1 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws SQM 46.20 2392.65 110540.43
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in
gloss / matt/ suede finish with high density protective surface layer and reverse
97 9.127 side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of
adhesive of approved quality.
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth
on all edges of flush door shutters (over all area of door shutter to be measured)
Providing and fixing wooden moulded beading to door and window frames with iron
screws, plugs and priming coat on unexposed surface etc. complete:
9.40.1 2nd class teak wood
MORTICE LOCK AND LEVER HANDLES- Providing and installing Tubular Handle TH 123
100 MR with Roses & Escutcheon in SS packaged with Mortice lockset 55mm backset, 20 SS EACH 22.00 3415.06 75131.32
forend, SS strike plate and EP Cylinder for all flush doors.
TOWER BOLTS:- Providing and fixing aluminium tower bolts, ISI marked, anodised
101 9.97 (anodic coating not less than gradeAC 10 as per IS : 1868 ), transparent or dyed to
required colour or shade, complete:
Digitally signed by MANISH
DOOR STOPPER:- Providing and fixing bright finished brass hanging type floor door
stopper with necessary screws, etc. complete.
Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm
diameter bolts, nuts and wooden plugs and embedding in cement concrete block
103 9.53 30x10x15cm 1:3:6 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm EACH 132.00 228.85 30208.20
Door Closer:- Providing and Fixing Door Closer For Entry Door
Polishing in high gloss/matt finish melamine clear polish on wood work in required
color/wooden shade texture with following process in the sequence as detailed
The surface to be polished is rubbed with sand paper 80/120 no. and then with sand
paper of 160/180 nos.
Applying two coats of sealer with spray gun and allowing sufficient drying time for 1st
coat and 2nd coat is allowed to dry for 8 to 12 hrs.
On drying of sealer coat, wet rubbing with emery cloth of finer grading with ample
water to remove excess sealer layer and make the surface further smooth after this
wet rubbing, then surface is applied with special grade melamine fillers to fill all the
small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on
which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs
On this, 1st coat of melamine polish is applied with spray gun using melamine clear
polish and melamine thinner in required proportion. This 1st coat is allowed to dry for
24 hrs then this dry surface is again fine wet rubbed smooth, which is further allowed
to dry for 12 hrs. The final melamine polish is applied with compressor pressure spray
gun using melamine clear polish and melamine thinner mixed in required proportion
complete as per direction of Engineer-in-Charge. (Final coat to be done in 1 or 2
layers without gap of time.)
Disposal of building rubbish / malba / similar unserviceable, dismantled or demolished
material by mechanical transport including loading, unloading and stacking, beyond
50 metres initial lead, complete as per direction of Engineer-in-Charge.
Dismantling doors, windows and clerestory windows (steel or wood) shutter including
107 15.12 chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:
15.12.1 Of area 3 sq. metres and Below Each 16.00 367.20 5875.20
15.12.2 Of area beyond 3 sq. metres Each 10.00 502.75 5027.50
Digitally signed by MANISH
Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising
of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever
required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1
and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in
any shape, colour and design duly reinforced with galvanized mild steel section
made of required shape & size as per CPWD Specification, uPVC extruded glazing
beads, interlocks and Inline sash adaptor (where ever required) of appropriate
dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia
with countersunk head, comprising of matching polyamide PA6 grade sleeve for
fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps
and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required)
shall be mitred cut and fusion welded/mechanically jointed duly sealed at all
corners, including drilling of holes for fixing hardware and drainage of water etc.
108 9.147A After fixing frame the gap between frame and adjacent finished wall shall be filled
with weather proof silicon sealant over backer rod of approved size and quality, all
complete as per approved drawing conforming to CPWD specification & direction of
Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles
to be as per design approved by Engineer-in- Charge.
Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without
high performance coatings as per design requirements and conforming to IS: 3548 &
IS: 16231 shall be paid separately.
Note: Structural design proof checked from a Government Engineering Institute, to
be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as
per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds
Two track two panels sliding window with Aluminium channel for roller track, wool
pile, nylon rollers with SS 304 body.
Using R2 series with frame (40mm & above) x (40mm & above) & sash (25mm &
9.147A1.1 above) x (50mm & above) with zinc alloy (zamak) powder coated touch locks with sqm 70.20 8298.85 582579.27 - -
hook (Height upto 1.2 metre).
GST Modification factor @0.973 on DSR items 14840207.39
Cost Index @1.03 on DSR items 15285413.62
Digitally signed by MANISH
Sub-Head : Renovation & Restoration works of Kendriya Vidyalaya NO. 1, AFS, Sector 14, Gurugram, Haryana
BOQ FOR PLUMBING & FIRE FIGHTING
SECTION DESCRIPTION DSR (AMOUNT) MR (AMOUNT)
A SANITARY FIXTURES & FITTINGS 629203.60 476,796.60
B WATER SUPPLY & INTERNAL DRAINAGE (SOIL, WASTE & VENT PIPES) 500953.44 307786.61
Total Cost ( Carried Forward) in Rs. 1914740.25
Digitally signed by MANISH
Sub-Head : Renovation & Restoration works of Kendriya Vidyalaya NO. 1, AFS, Sector 14, Gurugram, Haryana
SUB HEAD A: SANITARY FIXTURES & FITTINGS
SL. DSR - DESCRIPTION OF ITEMS
UNIT Qty DSR Rate (Rs.) NS Rate (Rs.) DSR Amount (Rs) NS Amount (Rs)
Providing and fixing white vitreous china extended wall mounting
water closet of size 780x370x690 mm of approved shape including
providing & fixing white vitreous china cistern with dual flush fitting, of
flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including
seat cover, and cistern fittings, nuts, and gasket etc complete.
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass
pillar taps, 32 mm C.P. brass waste of standard pattern. including
painting of fittings and brackets, cutting and making good the walls
wherever require: White Vitreous China Flat back wash basin size 550x
2 17.7.4 400 mm with single 15 mm C.P brass pillar tap Each 15 1879.20 28188.00
Providing and fixing necessary accessories for undercounter wash
basin, including R.S./C.I. brackets/supports, 32 mm C.P. brass waste of
standard pattern, C.P. brass wall flange, 32 mm dia. C.P. brass bottle
3 MR trap and 32 mm dia. C.P. pipe to wall flange, including unions, rubber Each 15 2900.00 43500.00
washers, connectors, fixing hardware and cutting and making good
the walls wherever required, complete with installation, testing and
commissioning, as required and as directed by Engineer-in-Charge.
Digitally signed by MANISH
Providing and fixing white glazed vitreous china table-top wash basin
of size 440 × 440 mm, of approved make, shape and design, including
providing and fixing suitable table-top/counter-top support
arrangement, 32 mm C.P. brass waste of standard pattern, C.P. brass
wall flange, 32 mm dia. C.P. brass bottle trap and 32 mm dia. C.P.
pipe to wall flange, including unions, rubber washers, connectors,
fixing accessories, cutting and making good the walls/floor wherever
required, complete with supply, installation, testing and
commissioning, complete in all respects as required and as directed
by Engineer-in-Charge.
Providing and fixing wash basin with C.I. rackets, 15 mm dia CP Brass
single hole basin mixer of approved quality and make, including
of fittings and brackets, cutting and making good the walls wherever
5 17.7A required: (a) White Vitreous China Wash basin size 550x400 mm with a Each 20 3960.55 79211.00
15 mm CP Brass single hole basin mixer
6 MR Providing & fixing vitreous chinaware urinal comprising
Large flat back wall hung urinal in glazed vitreous China
a new magnum urinal
15 mm electrically operated solenoid valve with infra red
b sensor mounted in a box with SS Cover.
CP brass chromium plated flush piping from solenoid valve to urinal
terminated with a 15 mm screwed spreader
d 32 mm nominal bore CP cast brass waste
32 mm nominal bore CP cast bottle trap with extension pipe rubber
adopter for waste connection, CP brass wall flange.
For supply,installation,testing & commissioning of sanitary
fixtures(white colour) as per above details.
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per
IS:13983 with C.I. brackets and stainless steel plug 40 mm, including
painting of fittings and brackets, cutting and making good the walls
7 17.10.1 wherever required:
Kitchen sink with drain board
Digitally signed by MANISH
Providing and fixing 15 mm C.P. brass sink mixer with swinging casted
spout, wall-mounted model, of approved make and quality, complete
with 450 mm long copper connecting pipes, brass nuts, C.P. brass wall
flanges and all necessary washers, connectors, fixing accessories,
8 MR including installation, testing and commissioning, complete in all Each 6 4345.00 26070.00
respects as required and as directed by Engineer-in-Charge.
9 17.34 Providing and fixing toilet paper holder :
Providing and fixing 5 mm minimum thick superior quality plate glass
mirror with beveled edges, backed with 6 mm thick BWP grade marine
plywood, fixed to wooden cleats with C.P. brass screws and washers,
including providing and fixing 40 mm wide teak wood frame around
the mirror, properly mitred/jointed, sanded and polished with
approved finish, including all necessary fixing accessories, labour,
10 MR cutting, bevelling, polishing and making good the surface wherever Sqm 10 4900.00 49000.00
required, complete in all respects as required and as directed by
Engineer-in-Charge.
Providing & fixing Hand Shower (Health Faucet) with 8mm dia, 1M long
PVC tube and wall hook CP brass wall flange
For supply of sanitary fixtures as per above details Each 20 1730.53 34610.60
Providing, fixing, testing and commissioning of storage type electric
water heater of 25 litres capacity, horizontal/vertical type, with 1.5 kW
heating element, automatic thermostatic temperature control,
thermal safety cut-out, pressure release/safety valve, suitable
inlet/outlet connections, drain arrangement, wall-mounting brackets,
expansion fasteners with M.S. nuts and bolts and all necessary
12 MR accessories, including connecting pipes/fittings, cutting and making Each 4 12800.00 51200.00
good the walls wherever required, complete with supply, installation,
testing and commissioning in all respects as required and as directed
by Engineer-in-Charge.
Digitally signed by MANISH
Providing and fixing wall mounted 25 mm dia stainless steel coated
grab bar, 450 mm long, of approved make and quality, including
stainless steel/CP finished wall flanges and fixing brackets, heavy duty
anchor fasteners, screws, nuts, washers and all necessary accessories,
including drilling, fixing, alignment, testing and making good the walls
wherever required, complete in all respects as required and as
directed by Engineer-in-Charge.
Providing and fixing C.P brass bib cock of approved quality
15 mm nominal bore
Providing and fixing uplasticised PVC connection pipe with brass
15 18.21.2.1 unions : 45 cm length: 15 mm nominal bore Each 10 97.75 977.50
Providing and fixing stainless steel finish paper towel dispenser of
approved quality, having capacity of 300–350 paper towels,
complete with wooden cleats, C.P. brass screws, necessary fixing
16 MR accessories and labour for installation, complete in all respects as Each 20 4500.00 90000.00
directed by the Engineer-in-Charge.
TOTAL CARRIED OVER TO SUMMARY 629203.60 476796.60
Digitally signed by MANISH
PLUMBING & DRAINAGE WORK
Sl DSR No Quantit Market Amount(Rs)
Description of Item Unit DSR rate Amount(Rs)
No 2023 y Rate
Providing and fixing P.V.C. waste pipe for sink or wash
1 17.28 basin including
P.V.C. waste fittings complete.
17.28.1 Semi rigid pipe
Providing and fixing PTMT Bottle Trap for Wash basin and
Bottle trap 38 mm single piece moulded with height
of 270 mm, effective length of tail pipe 260 mm from
17.70.2 the centre of the waste coupling, 77 mm breadth with each 30.00 375.65 11269.5
25 mm minimum water seal, weighing not less than 263
Providing and fixing PTMT towel rail complete with
brackets fixed to wooden cleats with CP brass
screws with concealed fittings arrangement of
approved quality and colour.
600 mm long towel rail with total length of 645 mm, width
17.73.2 78 mm and effective height of 88 mm, weighing not less each 20.00 708.95 14179
CP Brass fittings
Providing and fixing unplasticised PVC connection
pipe with brass unions
18.21.2 45 cm length
18.21.2.1 15 mm nominal bore each 20.00 85.00 1700
Providing and fixing C.P. brass bib cock of approved
quality conforming to IS:8931
18.49.1 a) 15 mm nominal bore each 20.00 506.80 10136
Providing and fixing C.P. brass long body bib cock of
6 18.51 approved quality conforming to IS standards and
weighing not less than 690 gms.
Digitally signed by MANISH
18.51.1 a) 15 mm nominal bore each 12.00 798.95 9587.4
Providing and fixing C.P. brass angle valve for basin mixer
7 18.53 and gyser points of approved quality conforming to
18.53.1 a) 15 mm nominal bore each 40.00 574.30 22972
Providing and fixing C.P. brass shower rose with 15 or
Providing and fixing C.P. brass stop cock (concealed)
9 of standard design and of approved make conforming
18.52.1 15mm nominal bore each 10.00 670.45 6704.5
Providing and fixing unplasticised-PVC pipe clips of
approved design to unplasticised-PVC pipes by means of
50x50x50 mm hard wood plugs, screwed with MS screws
of required length including cutting brick work and fixing
in cement mortar 1:4 (1 cement : 4 coarse sand) and
making good the wall etc. complete.
Providing and laying cement concrete 1:5:10(1 cement :
5 coarse sand : 10 graded stone aggregate 20mm
11 19.2.1 nominal size) around P.V.C Soil and waste pipe
including bed concrete as per standard
design(embedded in the flooring / ground)
Providing and fixing on wall face unplasticised-Rigid PVC
rain water pipes conforming to IS: 13592 Type A including
jointing with seal ring conforming to IS: 5382 leaving 10mm
gap for thermal expansion.
Digitally signed by MANISH
Providing and fixing on wall face unplasticised PVC
moulded fittings/accessories for unplasticised Rigid PVC
13 12.42 rain water pipes conforming to IS:13592 Type A
including jointing with seal ring conforming to IS:5382
leaving 10mm gap for thermal expansion.
12.42.5.2 Bend 87.5 degree
12.42.6 Shoe (Plain)
Providing and fixing to the inlet mouth of rain water pipe
14 12.44 cast iron grating 15 cm diameter and weighing not less Each 10.00 54.70 547
than 440 grams.
Providing and fixing unplasticised-PVC pipe clips of
approved design to unplasticised-PVC rain water pipes
by means of 50x50x50 mm hard wood plugs, screwed
with MS screws of required length including cutting
brick work and fixing in cement mortar 1:4 (1 cement : 4
coarse sand) and making good the wall etc. complete.
Making khurras 45x45 cm with average minimum
thickness of 5 cm cement concrete 1:2:4 (1 cement : 2
coarse sand : 4 graded stone aggregate of 20 mm
nominal size) over PVC sheet 1m x 1 m x 400 micron,
finished with 12 mm cement plaster 1:3 (1 cement : 3
coarse sand) and a coat of neat
cement,punning,rounding the edges and making and
finishing the outlet complete.
Digitally signed by MANISH
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply including all CPVC plain & brass threaded
fittings i/c fixing the pipe with clamps at 1.00m spacing.
This includes jointing of pipes & fittings with one step
CPVC solvent cement and the cost of cutting chases and
making good the same including testiang of joints
complete as per direction of Engineer in Charge.
Concealed work including cutting chases and making
good the walls etc.
17 18.8.3 25mm dia nominal outer dia pipes Rm. 75.00 627.25 47043.75
18 18.9.6 50mm dia nominal outer dia pipes Rm. 75.00 794.26 59569.5
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded
19 18.7 fittings, including fixing the pipe with clamps at 1.00 m
spacing. This includes jointing of pipes & fittings with one
step CPVC solvent cement and testing of joints complete
as per direction of Engineer in Charge.
Internal work-Exposed on wall
18.7.2 20 mm nominal outer dia Pipes Metre 150.00 335.00 50250
Digitally signed by MANISH
Providing and fixing Chlorinated Polyvinyl Chloride
(CPVC) pipes, having thermal stability for hot & cold
water supply, including all CPVC plain & brass threaded
fittings, i/c fixing the pipe with clamps at 1.00 m spacing.
20 This includes jointing of pipes & fittings with one step
CPVC solvent cement and the cost of cutting chases and
making good the same including testing of joints
complete as per direction of Engineer in
Concealed work, including cutting chases and making
good the walls etc.
18.8.2 20 mm nominal outer dia Pipes Metre 150.00 446.00 66900
Providing and fixing gun metal gate valve with wheel of
approved quality.
18.17.1 25mm dia nominal bore Each 15.00 622.40 9336
18.17.4 50mm dia nominal bore Each 15.00 1026.65 15399.75
22 18.16 Providing and fixing brass stop cock of approved quality.
Providing and fixing in floor and wall face Ringfit UPVC
Conventional system for soil and waste water pipes
conforming to Type B including jointing with seal ring. (i)
Double socketed pipes.
Providing & fixing UPVC Floor trap of self cleansing design
with CP Jali complete in all respects.
P-Trap type Floor Trap 110 x 90 mm Nos. 15.00 270.09 4,051.35
25 MR Providing and fixing terminal guard.
Digitally signed by MANISH
Providing and fixing on wall face unplasticised - PVC
moulded fittings/accessories for unplasticised Rigid PVC
pipes including jointing with seal ring leaving 10 mm gap
for thermal expansion.
Single tee with door
Providing and fixing C.P. brass Two-way angle valve for
EWC points & for fixing Ablution Health Fauct of approved
quality conforming to15
mm nominal bore
28 MR Providing and fixing clean out plug
Providing and fixing on wall face unplasticised-Rigid
PVC pipes conforming to IS: 13592 Type A including
jointing with seal ring conforming to IS: 5382 leaving
10mm gap for thermal expansion.
160mm dia Under floor Metre 25.00 1,130.08 28,252.00
Providing and fixing pvc Inlet fitting with 2 inlets 80 mm
size fabricated from 110 mm dia PVC pipes(approx.
30 MR length=150mm to 300mm) and fixed to PVC trap with joint Each 10.00 750.00 7,500.00
and set in cement concrete as per standard drawing
Digitally signed by MANISH
Providing and Fixing Rectangular shaped urinal partition
with frosted 8-10mm glass of size 900mm x 450mm
32 MR complete as per direction of Engineer-in-Charge. No 16.00 8000.00 128000.00
TOTAL INTERNAL WATER SUPPLY & SANITATION WORKS [I+II] 500953.44 307786.61
Digitally signed by MANISH
Sub-Head : Renovation & Restoration works
of Kendriya Vidyalaya NO. 1, AFS, Sector 14, Gurugram, Haryana
ITEM DESCRIPTION DSR AMOUNT MR AMOUNT
S.NO. SUB HEAD
1 MAIN PANEL & DISTRIBUTION BOARD 78510.00 8549.00
4 LIGHTING FIXTURES 329997.00 302876.25
5 WIRING FOR DATA AND VOICE OUTLETS 302054.00 55860.88
6 CABLE TRAY.& RACE WAY. 331176.00 184499.75
GRAND TOTAL 3189963.88
GRAND TOTAL 3189963.88
Digitally signed by MANISH
Sub-Head : Renovation & Restoration works
of Kendriya Vidyalaya NO. 1, AFS, Sector 14, Gurugram, Haryana
DSR- Description
S.No 2025 Unit Qty Rate DSR Amount MR Amount
1 MAIN PANEL & DISTRIBUTION BOARD
1.1 DISTRIBUTION BOARDS.
Supply, installation, testing and commissioning of 415V, 3-phase, 4-wire, sheet steel,
double-door MCB Distribution Board, vertical type, suitable for indoor installation,
dust and vermin protected, duly powder coated, complete with incoming
MCB/ELCB/RCBO/MCCB of required rating and capacity, outgoing MCBs as
specified, copper/aluminium busbars of suitable rating, neutral bar, earth
terminal/bar, DIN rails, internal interconnections and all necessary accessories,
hardware and fixing materials, complete as required. The DB shall be installed
recessed/concealed in wall after necessary chase cutting and making good the
surface, or surface mounted wherever specified, including necessary cutting,
chasing, plastering and finishing to match the existing surface, complete in all
Supply, installation, testing and commissioning of 80A, 4 Pole, 415V MCCB having
rated short circuit breaking capacity of minimum 36 kA at 415V, with adjustable
thermal overload and magnetic short circuit protection, suitable for operation on 3-
MR phase, 4-wire AC supply, complete with all required connections, accessories and Each 1 8549.00 8549.00
fixing arrangements, including testing and commissioning, as required.
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415
V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted,
inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for
mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type
MCB TPDB is normally used where 3 phase outlets are required.)
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit
breaker suitable for inductive load of following poles in the existing MCB DB
2.10 complete with connections, testing and commissioning etc. as required:
Digitally signed by MANISH
B For LPDB and ACDB:
Supplying and fixing of following ways surface/ recess mounting, vertical type, 415
V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted,
inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for
2.5 mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type
MCB TPDB is normally used where 3 phase outlets are required.)
12 way (4 + 36), Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit
breaker suitable for inductive load of following poles in the existing MCB DB
2.10 complete with connections, testing and commissioning etc. as required:
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts,
2.15 residual current circuit breaker (RCCB), having a sensitivity current 30 mA in testing
and commissioning etc. as required.
Total of Main Panel/ DB carried over to summary 78510.00 8549.00
2.0 CABLES / MAINS
Supply, laying, testing and commissioning of 1.1 kV grade armoured power cable
having sector/circular shaped aluminium/copper conductors, PVC/XLPE insulated
cores, inner PVC sheathing, GI strip/wire armouring and overall extruded PVC
sheathing, conforming to relevant IS standards, including all necessary handling,
transportation, jointing as applicable, testing and commissioning, complete as
2.1 required. The cable shall be laid underground or on wall/ceiling surface as
specified, using suitable GI clamps, saddles, spacers and other required fixing
accessories, including necessary supports and hardware, complete in all respects
as directed by the Engineer-in-Charge.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1
KV grade of following size direct in ground including excavation, sand cushioning,
protective covering and refilling the trench etc as required.
Digitally signed by MANISH
10.1.4 Above 95 sq. mm and upto 185 sq. mm mtr. 5 497.00 2485.00
Laying and fixing of one number PVC insulated and
PVC sheathed / XLPE power cable of 1.1 KV grade of
following size on wall surface as required.
10.7.1 Upto 35 sq. mm (clamped with 1mm thick saddle) mtr. 200 64.00 12800.00
Above 95 sq. mm and upto 185 sq. mm (clamped with
25/40x3mm MS flat clamp)
Supplying and making end termination with brass compression gland and
aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE
11.1.27 aluminium conductor cable of 1.1 KV grade as required: 3½ X 185 sq. mm (57mm) Each 12.00 1001.00 12012.00
MR 35 sq.mm 3½ Core Aluminium, 1.1kV, XLPE/PVC, Armoured mtr. 50.00 518.00 25900.00
MR 16 sq.mm 4 Core Copper, 1.1kV, XLPE/PVC, Armoured mtr. 50.00 579.00 28950.00
MR 25 sq.mm 4 Core Copper, 1.1kV, XLPE/PVC, Armoured mtr. 50.00 953.00 47650.00
MR 4 sq.mm 3 Core Copper, 1.1kV, XLPE/PVC, Armoured – For AC Units mtr. 50.00 245.00 12250.00
Total of Cables / Mains carried over to summary 34451.00 114750.00
Point wiring for light point/fan/exhaust fan/call bell point with 2 runs of 1.5 sq.mm
and one run of 1.5 sq.mm FRLS insulated, multistranded copper conductor wires of
1100V grade, drawn through 25 mm dia medium class/approved PVC conduit or
suitable conduit, surface or concealed in wall/ceiling as required, conforming to IS
732, including all necessary junction boxes, conduit accessories such as bends,
elbows, couplers, saddles, etc., and ceiling rose/fan box as applicable, complete
with anodised/GI switch box, modular switch, modular plate and front cover plate,
including all fixing accessories, connections, testing and commissioning, complete
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm
FRLS/HFFR PVC insulated copper conductor single core cable in surface/
recessed steel conduit, with modular switch, modular plate, suitable GI box and
earthing the point with 1.5 sq.mm FRLS/HFFR PVC insulated copper conductor
3.2 1.3.3 single core cable etc. as required: Group C 90.00 2101.00 189090.00
Digitally signed by MANISH
Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell
point (without independent switch etc.) with 1.5 sq. mm FRLS/HFFR PVC insulated
copper conductor single core cable in surface/ recessed steel conduit, and
earthing the point with 1.5 sq. mm FRLS/HFFR PVC insulated copper conductor single Per
core cable etc. as required: Group C Pts
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS
3.3 1.7 insulated copper conductor, single core cable in surface/ recessed steel
conduit as required.
2x1.5sqmm+1x1.5sqmmearth wire Per
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire Per
2 X 4 sq. mm + 1 X 4 sq. mm earth wire Per
Wiring for twin control point wiring using 1.5 sqmm copper conductor FRLS PVC
insulated copper conductor cable drawn through 25 dia MS conduit laid in
surface/concealed over false ceiling or in slab/wall chases including ,2way modular
switches,modular plate ,suitable GI box and earthing the point with 1.5 sqm FRLS Per
PVC insulated copper conductor single core Pts
cable as required
Supplying and fixing following modular switch/ socket on the existing modular plate
3.5 1.24 & switch box including connections but excluding modular plate etc. as required.
3 pin 5/6 A socket outlet
6 pin 15/16 A socket outlet
Supplying and fixing following size/ modules, GI box alongwith modular base &
for modular switches in recess etc. as required.
Digitally signed by MANISH
3 Module (100mmX75mm)
6 Module (200mmX75mm)
Supplying and fixing following Modular base & cover plate on existing modular
3.7 1.28 metal boxes
etc. as required.
Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper
3.8 1.19 insulated, shielded with fine tinned copper braid and protected with PVC sheath in Meter 100.00 54.00 5400.00
the existing surface/ recessed steel/ PVC conduit as required.
Supply and fixing of following sizes of MS conduit along with accessories in surface
3.90 1.20 including painting in case of surface conduit,or cutting the wall and making good
the same in case of recessed conduit as required
Supply and fixing of 3 Nos. 6A, 3-pin modular socket outlets with 6-module GI
modular box, base plate and cover plate below worktop, along with 1 No. 6A, 3-pin
modular socket outlet, 1 No. 6A modular switch and 1 No. 16A modular switch for
controlling the above sockets, housed in 4-module GI modular box with modular
base plate and cover plate above worktop, including all necessary connections,
internal wiring, fixing accessories, screws, terminals and other accessories, complete
as per drawings and instructions of the Engineer-in-Charge.
Total of Wiring carried over to summary 1437240.00 10000.00
4 LIGHTING FIXTURES
Digitally signed by MANISH
LED Panel light 2x2 ft. (System lumen efficacy ≥120 <135 lm/Watt)
Supplying, Installation, Testing & Commissioning of Panel light 2x2 ft., of following
body material and construction as per IS : 10322 with driver as per the requirement
with Driver efficiency >85%, Operating voltage AC 140-270 Volt, frequency 50/60
hz, Operating temp range -5 0C to 40 0C, internal surge protection of 2.5 KV
with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,
UGR (Unified Glare Rating) <19, Flicker free, (flicker should be below 5 %), life time
(LED, Driver & electrical circuitry), of minimum 50000 Burning Hours with , 70% of
initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K
/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3,
Maximum power consumption should not more than the specified
rating and Fixture shall be of relevant BIS standard. Manufactures Word Mark/ Name
Engraved/ Embossing/ Screen printing on housing. complete
4.1 8.7 in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC insulated
copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy ≥120 <135
lm/Watt output .LM79 & LM80 Test report and all testing required for LED fixtures
as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-
in-Charge as per requirement. (Thermal management: heat sink of aluminium
housing such that LED junction temperature shall not rise above 90°C).
Powder coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Digitally signed by MANISH
LED Down lighter (SMD Type) (System lumen efficacy >135lm/Watt)
Supplying, Installation, Testing & Commissioning of LED Recessed/surface Down
lighter (Round /square/Rectangular) SMD type of following body material with
PMMA and prismatic diffuser and construction as per IS : 10322 with driver as per
the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt,
frequency 50/60 hz, Operating temp range - 5 0C to 40 0C, internal surge
protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95,
IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below
5 %), life time (LED, Driver & electrical circuitry), life time of minimum 50000 Burning
Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation
IES TM-21-11 report, CCT 3000°K/ 4000°K /5700°K / 6500°K (As per ANSI Bin),
SDCM(Standard Deviation Color Matching) <3, Maximum power consumption
should not more than the specified rating and Fixture shall be of relevant BIS
4.2 8.3 standard. Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing
on housing. complete in all respect i/c external connections with 1.5 sq mm
FRLS/HFFR, PVC insulated copper conductor single core cable and earthing etc. as
required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt
output. LM79 & LM80 Test report and all testing required for LED fixtures as per BIS
shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge
as per requirement. (Thermal management: heat sink of aluminium housing such
that LED junction temperature shall not rise above 90°C). Powder coated die cast
/Extruded aluminium Body including trim
SITC of recessed-mounted PDC low-depth LED downlight, maximum 12W, delivering
minimum 1320 lumens, SMD based, with non-integral isolated LED driver having
inbuilt minimum 2kV surge protection, power factor >0.90 and THD <10%, having
rated life of minimum 50,000 burning hours at L70/B50, suitable for continuous
operation at ambient temperature of 0°C to 45°C, complete with Teflon-coated
4.3 MR multistrand internal wiring and PVC-coated multistrand external wires, including all Nos. 125 855.01 106876.25
necessary mounting accessories, connectors, fixing materials, testing and
commissioning, complete as required and as directed by Engineer-in-Charge.
Digitally signed by MANISH
LED Batten light (System lumen efficacy ≥105 <120 lm/Watt). Supplying, Installation,
Testing & Commissioning of LED surface mounted Batten light of following bod
material and construction as per IS : 10322 with driver (Replaceable) as per the
requirement with Driver efficiency >85%, Operating voltage AC 140270 Volt,
frequency 50/60 hz, Operating temp range -5 °C to 40 °C, internal surge protection
of 2.5 KVwith Short & Open circuit protection, THD < 10%, P.F.≥0.95, IP20, CRI >80,
Flicker free, (flicker shouldbe below 5 %), life time (LED, Driver & electrical circuitry),
of minimum 50000 Burning Hours with 70% of initial Lmen maintained till life
ends, CCT 3000°K / 4000°K / 5700°K /6500°K (As per ANSI Bin), SDCM(Standard
Deviation Colour Matching) <3, Maximum power consumption should not more
than the specified rating and Fixture shall be of relevant BIS standard.
Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing.
complete in all respect i/c external connections with 1.5 sq mm FRLS/HFFR, PVC
4.4 8.9 insulated copper conductor single core cable and earthing etc. as required with
Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output .
LM79 & LM80 Test report and all testing required for LED fixtures as per BIS shall
be submitted. Shape size and CCT shall be as approved by Engineer-in
Charge as per requirement. (Thermal management: heat sink of aluminium
housing such that LED junction temperature shall not rise above 90°C). Powder
coated die cast /Extruded aluminium Body (Thickness > 1.20 mm)
Supplying, Installation, Testing and commissioning of Passive Infrared (PIR)
technology based occupancy sensor having high performance, non regulating
programmable type, suitable for connected load upto 10Amp , for mounting
4.5 7.1 height up to 3 meter and for 5 m diameter coverage area along with necessary EACH 2.00 4896.00 9792.00
fixing arrangements i/c programming at site etc. complete as required.
Installation, Testing and Commissioning of exhaust fan in the existing opening,
including making good the damage, connection, testing, commissioning etc. as
Digitally signed by MANISH
Supplying, installation, testing and commissioning of 1200 mm sweep, 3-blade
ceiling fan, 5-star rated, suitable for 230 V, 50 Hz AC supply, complete with
capacitor, canopy, standard GI down rod up to 300 mm length, suspension
arrangement, standard electronic regulator, necessary fixing accessories,
connecting wiring and all other accessories, including labour for installation, testing
and commissioning, complete in all respects as per the directions of Engineer-in-
Total of Light Fixture carried over to summary 329997.00 302876.25
5 WIRING FOR DATA AND VOICE OUTLETS
Supply and fixing the following sizes of PVC medium duty ISI marked conduits (IS :
9537 Part- III) complete with accessories such as bends, junction boxes, pull boxes
etc., in recess or on surface including cutting chases in the walls/floors and making
5.1 1.21 good the same complete as
Supplying, drawing, Testing and commissioning of Cat6A UTP 4 pair, 23 AWG solid
copper cable in existing conduit/ on surface, U/FTP, LSZH, Non-Plenum, Horizontal
(solid) Cable suitable for high speed data networking application supporting upto
10Gbps over a 100 meter channel. The 4 Unshielded Twisted Pairs (UTP) cable with
5.2 39.18 color coded insulation for easy indentification should have FLAME PROPERTIES i.e.
Flammability Test - IEC 60332-1, Smoke Density - IEC 61034, LSZH standards
compliance: ANSI/TIA-568 C.2, ISO/IEC 11801, IEEE 802.3an, RoHS. Delay Skew should
be < 45NS. The outer Cable Diameter should be 7.5 + 2 mm. Cable
should have been tested and verified by UL/ ETL etc. complete as required.
Supplying, Installation, Testing and commissioning of CAT6A Copper Information
Outlet (IO) with face plate of color as per site requirement, should have ETL/UL
verification program certificate for compliance with ANSI/TIA-568.2-D. All copper
Cable and Components should be from same OEM to maintain compatibility
and interoperability etc. complete as required.
Supplying and fixing following modular switch/ socket on the existing modular plate
5.4 1.24 & switch box including connections but excluding modular plate etc. as required.
Telephone socket outlet
Digitally signed by MANISH
Supplying, Installation, Testing and commissioning of CAT6 Copper Information
Outlet (IO) with face plate of color as per site requirement, should have ETL/UL
verification program certificate for compliance with ANSI/TIA-568.2-D. All copper
Cable and Components should be from same OEM to maintain compatibility
and interoperability etc. complete as required.
Supplying, Installation, Testing and commissioning of CAT6A Copper Information
Outlet (IO) with face plate of color as per site requirement, should have ETL/UL
verification program certificate for compliance with ANSI/TIA-568.2-D. All copper
Cable and Components should be from same OEM to maintain compatibility
and interoperability etc. complete as required.
Supply ,laying ,installing , testing and commmissioning of the 50 pair multi core 0.61
mm annealed copper conductor PVC insulated and PVC sheathed armoured
telephone cables generally conforming to ITD S/WS-11-C and IS 1554 part I direct in
5.7 MR ground /surface and / or in existing pipe as required and includig making terminal mtr. 50.00 457.57 22878.50
joints, complete as required.
Supplying, installing, testing and commissioning of 24 port Cat 6A patch panels
available with block of four equipped with tool less IO, Rack Mountable. 19"
5.8 MR Modular Patch Panel, loaded CAT6A U/UTP 24 port LCS2 rack mountable to be EACH 2.00 16491.19 32982.38
compatible in 4nos of 6 X RJ 45 Tool less connector U/UTP unit in a block.
Supplying and fixing 42U Rack with 6 inch Castor wheels and front brake Floor
Standing Rack with Main Frame Pillar of 1.6mm CRCA Sheet with removable side
panels, L- Shape adjustable Vertical Mounting Rail of 2mm with 'U'Marking
completely knocked-down condition (CKD) Shape, fitted with 4 number cooling
fans, minimum 8nos two line cable entry/exit provision at top and bottom with
rubber protection, Front door 5mm Toughened Glass with MS frame or MS
5.9 39.25 perforated with lock, Rear MS vented or perforated door, Powder coated Color- Each 1.00 32954.00 32954.00
RAL- 7035 or black, complied with UL & RoHS, 2 x 6 sockets 16A power distribution
units, 3 numbers closed cable organizer, Hardware mounting screws packet of 20 x 1
number, etc. complete as required.
Total of Data & Voice carried over to summary 302054.00 55860.88
8 CABLE TRAY.& RACE WAY.
Digitally signed by MANISH
Supplying and installation following size of perforated painted with powder coating
M.S. cable trays Tee with perforation not more than 17.5%, joined with
connectors, suspended from the ceiling with two numbers MS/GI Suspenders i/c
6.1 4.3 base of suitable size MS/GI angle, bolts & nuts, painting suspenders, fastner etc as
a) 4.3.1 100 mm width X 50 mm depth X 1.6 mm thickness RM 100.00 1089.00 108900.00
b) 4.3.2 150 mm width X 50 mm depth X 1.6 mm thickness RM 80.00 1281.00 102480.00
c) 4.3.4 300 mm width X 50 mm depth X 1.6 mm thickness RM 60.00 1826.00 109560.00
Total of Cable Tray carried over to summary 320940.00 0.00
GI Raceway & Junction boxes ( Raceway on floor shall be of aluminium only)
Providing and fixing 2 mm thick steel sheet factory-fabricated, post-galvanized,
compartmentalized raceway of specified size, complete with internal
partition/compartments, removable 3 mm thick GI cover, knock-out holes, fixing
accessories, earthing with 8 SWG copper earth wire, floor supports, bends, access
boxes, tap-off boxes, cross-over sections and all necessary accessories, including
cutting, drilling, fixing and making good, complete as required and as per
specifications and directions of Engineer-in-Charge. Overhead/wall-mounted
recovery and function boxes shall be 1.6 mm thick.
a) 300 mm wide x 38 mm deep raceway RM 25.00 2506.51 62662.75
b) 225 mm wide x 38 mm deep raceway RM 25.00 2110.90 52772.50
c) 150 mm wide x 38 mm deep raceway RM 25.00 1603.10 40077.50
d) 100 mm wide x 38 mm deep raceway RM 25.00 1159.48 28987.00
Supplying and fixing metal box of following sizes (nominal size) on surface or in
6.3 1.22 recess with suitable size of phenolic laminated sheet cover in front including
painting etc. as required.
250 mm X 300 mm X 60 mm deep
150 mm X 150 mm X 60 mm deep
Total of Raceway carried over to summary 10236.00 184499.75
Total of Cable Tray & Raceway carried over to summary 331176.00 184499.75
Digitally signed by MANISH
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
NIT KV Gurugram.pdf
Tender Document
Tender BOQ KV Gurugram.pdf
Tender Document
SCC KVS gurgaon.pdf
Tender Document
List of Make.pdf
Tender Document
updated forms.pdf
Tender Document
ITT.pdf
Tender Document
GCC 2026 upto 2nd amendment.pdf
Tender Document
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].