Senior Manager
EM-1, Sector-39, Noida
Annual Maintenance (Repairing of 63 KVA Transformer) installed for street Light different location and main road of sector- 80, 81 ,83, 84, 85, 86, 87, 88, 89, 90, 145, 146, 147, 148, Noida.
2026_NOIDA_1191621_1
30/GM(E/M)/SM(E/M)-I/ET/26-27
Open Tender
Electrical Works
Fixed-rate
365 days
NOIDA
Please refer to tender documents
3 documents required · 3 mandatory
₹2,832
NOIDA
₹96,200
30 Sept 2026
30 Sept 2026
14 Oct 2026
30 Sept 2026
13 Oct 2026
30 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Repair of 63 KVA Transformer incl. changing of HV & LV Coil, Bushing, Gasket & fresh transformer oil without returning of old & unsearciable material. Complete in all respects as per direction of E/I.(AOR) | 38 | Nos. | 42,350 | ₹16,09,300 |
| 2 | Dis./Re-errection of 25/63/100/250 KVA Al. wound outdoor type Transformer as per ISS including fees as per direction of E/I.(AOR) | 38 | Nos. | 4,400 | ₹1,67,200 |
| 3 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Grandlay, Skytone, Havell's make)
1) 70 Sq.mm. 3.5 Core | 823 | Mtr | 723.34 | ₹5,95,308.82 |
| 4 | S/F of cable Lug(socket) to the cable lead. Complete in all respects as per PS No. 504
2)- 70 Sq.mm. | 108 | Nos | 79.06 | ₹8,538.48 |
| 5 | Supply and making strait through joint with cast resin compound including ferrules and other joints material for following size of PVC insulated and PVC sheathed/XLPE aluminium conductor cable of 11 KV grade as required
a) 3.5x70 sq. mm ((Electrical DSR-18/Ite. No. 9.3.20 pg.35) | 52 | Nos. | 3,492 | ₹1,81,584 |
| 6 | Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod with hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. (PS no 729(c) P-144) | 6 | Nos. | 23,246 | ₹1,39,476 |
| 7 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(PS no 716/ P-138) | 152 | Mtr. | 106.2 | ₹16,142.4 |
| - | S/E of overhead line with ACSR conductor on steel tubular poles incl. compression joint, laying stringing and binding etc. as PS No. 627 | 80 | Kgs | 310.34 | ₹24,827.2 |
| - | New Transformer oil for Transformer of approved make as per direction of E/I. | 850 | Ltr. | 118 | ₹1,00,300 |
| - | Dehydration charges of Transformer oil as per direction of E/I. | 650 | Ltr, | 17.7 | ₹11,505 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.08 MB
TD.pdf
Tender Documents • 5.79 MB
Cap.xls
Additional Documents • 0.04 MB
BOQ_2247980.xls
BOQ • 0.25 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .