Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance ROOM NO 2 BUILDING NO 1 ROMA BANJARA TANDA CHS LTD NEW CHIKUWADI MANKHURD MANKHURD MUMBAI MAHARASHTRA 400043 | MUMBAI SUBURBAN | MAHARASHTRA | 400043 | Admitted-Finance |
| 3 | Admitted-Finance H NO 384 EKTA ENCLAVE HOTEL SAHARA RESIDENCY BUILDING NAVPUR NAKA ROAD BOISAR WEST THANE MAHARASHTRA 401501 | PALGHAR | MAHARASHTRA | 401501 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹50.2 L
EMD Value
₹1.0 L
Closing Date
13 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Engineer, NRG
Chief Engineer, NRG, BARC, Trombay
Technical assistance in operation and maintenance of electrical electronics and instrumentation systems in various facilities of FRD BARC Trombay Mumbai 400085
2022_BARC_706260_1
BARC/FRD/EEI/MAINT/NIT01/2022
Open Tender
Support/Maintenance Service
Works
330 days
FRD, BARC, Trombay, Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹0
₹1.0 L
Conference room, FRD, BARC
6 Jan 2023
12 Aug 2022
15 Sept 2022
16 Aug 2022
13 Sept 2022
16 Aug 2022
24 Aug 2022
180 days
Amount
Electrical System: Preventive and breakdown maintenance of electrical systems of various plants consists of Class-IV panels, Transformers , 300AH battery banks, LT switchgear panels with 3000A/1250A/ 1000A ACBs, 100A SFUs (in general shift)
Preventive maintenance of class IV panel
Preventive maintenance of class III panel
Preventive maintenance of APFC panel
Preventive maintenance of Station Battery Bank
Preventive maintenance of Lighting & Plug circuit panel
Preventive maintenance of DOL/Star-delta starters from 7.5 KW to 22 KW rating
Preventive maintenance of DOL/Star-delta starters from 37.5 KW to 60 KW rating
Preventive maintenance of DOL/Star-delta starters from 75 KW to 132 KW rating
Providing power supply for various electrical equipment like flood lights, 3-phase welding machine etc. as per requirement.
Cleaning, servicing, repair & maintenance of normal and emergency MCB-DBs, Integrity & tightness checking of terminals / connections, checking of insulation healthiness at terminations, checking of mechanical movement of switch action-rod, U -Clamps, push buttons checking of earth connections etc. at various areas of plant
Attending breakdown maintenance of lighting fixtures at various plants involving removal of defective lighting fixture, checking for possible faults, replacement of defective components and installation & testing of fixtures
Assisting in maintenance and motor overhauling, Cable laying etc. consists of providing tools and materials required for the job, cleaning and removal of scrap and waste generated during the work
Cleaning, Servicing, Repair & maintenance of MCCs at various plants consists of cleaning of panel Integrity & tightness checking of terminals / connections, checking of insulation healthiness at terminations, checking of mechanical movement of switch action-rod, U -Clamps, push buttons, checking of earthling etc.
Maintenance of earth pits and measurement & logging of earth resistance.
Maintenance of Electrical System in Round The Clock (RTC) shifts
Assisting in operation, surveillance and maintenance of major electrical equipment in round the clock shift at sub-station in Reprocessing Plant including preventive maintenance and breakdown maintenance of electrical equipment including Sub-station LT switchgear and transformers on round the clock shift basis, monitoring & recording of voltages, currents, P.f. etc. of various feeders, temperature of operating motors & starters, maintenance of 2x300AH battery banks, attending breakdown maintenance of LT switchgear panel consisting 3 nos. 3000 A ACB , 4 nos. 1250A ACB, 5 Nos. 1000 ACB , 20 Nos. SFU 100A, 300A , breakdown maintenance of Starters from 5 hp to 180 HP 3 Nos., connection of 3-phase welding machine , providing flood light connections, attending tube light fixtures etc. Note: i) Spares will be issued free of cost at one point, ii) Minor adjustments shall be accommodated in internal parts/complexity of system/times of incidental breakdowns of switchgears. iii) Minimum one contractor person shall be ensured per shift. Above jobs are grouped as per month basis.
Maintenance of Process Instrumentation System in General Shifts:
Calibration service for Differential Pressure transmitters installed in plant area including preparation of calibration report, entry of reading to calibration software, labelling of transmitter etc.
Calibration service for Temperature transmitters installed in plant area, preparation of calibration report, entry of reading to calibration software, labelling of transmitter etc. using standard temperature calibrator
Maintenance of PLC/SCADA based system, development / modification of SCADA HMI pages, Schneider PLC logic programming, communication testing, troubleshooting of scripts related to Citect SCADA system
Cleaning, healthiness and functional checking of panels, panel mount instruments, terminal / connectors, exhaust fans etc. for following components located at various plant sites
Cleaning of racks and installed transmitters and solenoid valves located at various plant sites
Cleaning and healthiness checking of workstations and server computers located at various plant sites
Breakdown maintenance of field instruments i.e. transmitters, rotameters, PRVs, solenoid valves and electrical & pneumatic loops
Maintenance of Electronic System in General Shifts:
Cleaning, healthiness and functional checking of various nuclear instrument panels, panel mount instruments, terminal / connectors, exhaust fans etc. for following components located at various plant sites
Operating consoles & server stations: cleaning of console, CPU, monitor, keyboard & exhaust fans, cleaning & functional checking of exhaust fans, cleaning of server stations including all associated hardware
Nuclear instruments: Cleaning of instruments, checking of LV & HV supplies, functional checking and electronic calibration of instruments
PA system: Cleaning of panels and amplifiers, healthiness checking of terminals / connectors, checking of speakers, functional checking of system
Access Control system: Cleaning of panels, healthiness checking of terminals / connectors, cleaning of cameras, lenses & its housing installed in various area of the plant, functional checking of system
CRPC system: Healthiness checking of terminals / connectors, preventive maintenance of alarm annunciators & videographic recorders, functional checking of system
Space Controls
Shree Gajanan Facilities Pvt. Ltd.
ASIAN CONTROL SYSTEM
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .