Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.10Admitted-Finance | ₹28.10 | L1 | Admitted-Finance |
| 2 | L2₹41.96+₹13.86 (49.3%)Admitted-Finance 1 429 15 GALI NO 1 FRIENDS COLONY INDUSTRIAL AREA GT ROAD SHAHDARA EAST DELHI DELHI 110095 | SHAHDARA | DELHI | 110095 | ₹41.96+₹13.86 (49.3%) | L2 | Admitted-Finance |
| 3 | L3₹66.84+₹38.74 (137.9%)Admitted-Finance 109 FIRST FLOOR DDA BUILDING NO 5 DISTRICT CENTRE JANAK PURI WEST DELHI DELHI 110058 | WEST DELHI | DELHI | 110058 | ₹66.84+₹38.74 (137.9%) | L3 | Admitted-Finance |
| 4 | L4₹172.87+₹144.77 (515.2%)Admitted-Finance 25 140 OM DULARI SHAKTI NAGAR DELHI DELHI 110007 | NORTH DELHI | DELHI | 110007 | ₹172.87+₹144.77 (515.2%) | L4 | Admitted-Finance |
| 5 | L5₹548.68+₹520.58 (1852.6%)Admitted-Finance | ₹548.68+₹520.58 (1852.6%) | L5 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1 L
Closing Date
29 Jul 2019, 4:00 pmClosed
Sr. Stores Officer on behalf of Director AIIMS
Store Section (DO), Ist Floor, Animal House Building, AIIMS, New Delhi 110029
Purchase of Different Types of Surgical Disposable items
2019_AIMSD_481116_1
XX-29/SO(DO)/Different Types of Surg. Disp. items/
Open Tender
Consumables (Hospital / Lab)
Buy
45 days
AIIMS, New Delhi
As per TED.
8 documents required · 8 mandatory
₹0
₹1 L
Yes
11 Jul 2020
26 Jun 2019
30 Jul 2019
26 Jun 2019
29 Jul 2019
26 Jun 2019
26 Jun 2019 - 10 Jul 2019
Different Types of Surgical Disposable Items
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) • ET Tube should have tapered shaped cuff with low pressure technology to reduce micro-aspiration. • Should have cuff inflation valve and Magill Curve. • Should have hooded Murphy Tip With Eye. • Should enable continuous or intermittent secretion management through subglottic drainage. • Sizes: 6.0
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) (Specification as 1.0) • Sizes: 6.5mm
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) (Specification as 1.0) Size: 7.0mm
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) (Specification as 1.0) Size:7.5mm
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) (Specification as 1.0) Size:8.0mm
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) (Specification as 1.0) Size:8.5mm
ET TUBE WITH TAPERED SHAPED CUFF WITH SUBGLOTTIC SUCTION (CE European Certified) (Specification as 1.0) Size:9.0mm
PROSEAL LMA • Reusable with integrated bite block and double cuff. • Should be of silicon material. • Should have port for aspiration and port size should be adequate enough for Ryle’s tube insertion. Sizes: 1
PROSEAL LMA (Specification as 2.0) Size: 1.5
PROSEAL LMA (Specification as 2.0) Size: 2
PROSEAL LMA (Specification as 2.0) Size: 2.5
PROSEAL LMA (Specification as 2.0) Size: 3
PROSEAL LMA (Specification as 2.0) Size: 4
PROSEAL LMA (Specification as 2.0) Size: 5
TRANSPARENT TUBING PVC FOR SUCTION • Inner dia 6 mm length 5 mtrs.
TRANSPARENT TUBING PVC FOR SUCTION (Specification as 3.0) • Inner dia 08 mm length 5 mtrs.
FIBREOPTIC LARYNGOSCOPE (ADULT) should have the following characteristics: • Battery operated • Interchangeable blade system (Hook Type) • Mackintosh Blades size:1,2,3 & 4 • Blade able to extend and fold and easily removable • Handle & blades bright finished • Withstand autoclaving and chemical disinfectants • Fit to standard laryngoscope bulbs matt finish for straight light illumination • Light source should be fibreoptic, embedded in the body of the blade and should not be projecting out
FIBREOPTIC LARYNGOSCOPE (PAEDIATRIC) should have the following characteristics: • Battery operated • Interchangeable blade system (Hook Type) • Mackintosh Blades size:1 & 2 • Millar blade size : 0 & 1 • Blade able to extend and fold and easily removable • Handle & blades bright finished • Withstand autoclaving and chemical disinfectants • Fit to standard laryngoscope bulbs matt finish for straight light illumination Light source should be fibreoptic, embedded in the body of the blade and should not be projecting out
ANTIBIOTIC IMPREGNATED TRIPLE LUMEN CATHETER ( (USFDA approved) • Impregnated with antibiotics • Seldinger technique • Adult Sizes: 7/7.5 Fr. Length 16-20cm •
ANTIBIOTIC IMPREGNATED TRIPLE LUMEN CATHETER (USFDA approved) (Specification as 6.0) Paed. Sizes: 5 Fr. & 6cm Length
DOUBLE LUMEN CATHETER Size: 4Fr.
BLOOD ADMINISTRATION SET (B.T. Set) Specification as under: - (ISI/CE/ISO) • Manufactured from Non-Toxic Medical grade PVC • Moulded cylindrical double drip chamber fitted with sharp plastic spike and nylon filter. • Roller type regulator for accurate flow control • Moulded bubble latex bulb for extra medication or Y-port • I8 G Vein needle with protective cap • Double packed. • Sterile-Ready for use ( by ETO/Gamma ray) • Tube length should not be less than 1500 mm, transparent add, Nonkinkable. • The filter shall have uniform pores and shall cover a total area of not less than 10.0 cm2 and shall have pores size of 200 micrometer + 20 micrometer and should be clearly mentioned on package or literature/ brochure accompanied by Sterility and pyrogen free report. All PVC items should be certified medical grade only.
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) • Wire reinforced tubes • Non-kink able • Siliconised rubber • Size: 3.0mm Should be disposable & sterile, ready for use.
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 3.5mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 4.0mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 4.5mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 5.0mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 5.5mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 6.0mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) • Size: 6.5mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 7.0mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 7.5mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 8.0mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 8.5mm
E.T. Tube REINFORCED (CUFFED) (IS/CE/ISO) (Specification as 9.0) Size:- 9.0mm
SEALED WATER DRAINAGE BOTTLE (ADULT ) • Single and double chamber chest drainage set. • The capacity of Adult Bottle should be 1000 ml. • Provision of Non return Valve. • Non- kink able junction- conical bottle on at tube and bag. • Provision to avoid Capillary action at the wall. • Attachment tube with Stop Cock with universal connector. • Should be easy to milk (Soft and pliable) • To provide inbuilt funnel.
SEALED WATER DRAINAGE BOTTLE (PAEDIRIC ) • Single and double chamber chest drainage set. • The capacity of Adult Bottle should be 500 ml. • Provision of Non return Valve. • Non- kink able junction- conical bottle on at tube and bag. • Provision to avoid Capillary action at the wall. • Attachment tube with Stop Cock with universal connector. • Should be easy to milk (Soft and pliable) • To provide inbuilt funnel.
METERED INCENTIVE SPIROMETER • Volumetric lung exercise with dual printed scale upto 2500ml. • Good –better– best flow cup to encourage slow and deep breathing exercise. • Advanced low work of breathing design. • Built –in handle for ease of use . • Sensitive & Light weight bellow to detect smaller volume. • Latex free compact ergonoimicdesign . • Smooth mouthpiece with in built dust particle filter. • Also available in 5000ml capacity. • Trflow for pediatric use also
LARRYNGEAL MASK AIRWAY - Reusable (CE European/FDA) • Should have the following characteristics: • Reusable airway mask. • Flexible tube , transparent . • Connector for breathing circuit connection • Inflatable, soft, smooth silicone oval mask. • Attachment of mask with tube diagonal. • Aperture bar should be at the distal end. • Sizes 1
LARRYNGEAL MASK AIRWAY - Reusable (Specification as 13.0) • Size:- 1.5
LARRYNGEAL MASK AIRWAY - Reusable (Specification as 13.0) • Size:- 2
LARRYNGEAL MASK AIRWAY - Reusable (Specification as 13.0) • Size:- 2.5
LARRYNGEAL MASK AIRWAY - Reusable (Specification as 13.0) • Size:- 3
LARRYNGEAL MASK AIRWAY - Reusable (Specification as 13.0) • Size:- 4
LARRYNGEAL MASK AIRWAY - Reusable (Specification as 13.0) • Size:- 5
VENTED ENDOTRACHEAL BOUGIES –Adult & Pead. • Should have lumen to allow ventilation. • Should have 15mm connector . • Should have marking from the tip. • Should have distal eyes for oxygen flow. • Should have length of 700mm or more • Adult Size: 15Fr. Length 650mm or more
VENTED ENDOTRACHEAL BOUGIES –Adult & Pead. (Specification as 14.0) Paed. Size: 10Fr.
DISPOSABLE CPAP MASK SYSTEM WITH IN BUILT SAFETY FEATURE FOR Adult. CPAP Mask (USFDA Certified) with inbuilt manometer & Pressure relief valve. • Should be supplied with Head harness. • Should have provision to add on line nebulizer. • Should have provision or port for ETCO2 sampling lines without additional adapters. • Should accept Bacterial filter. • Should be able to use bacterial filter. • Should allow suctioning without disconnection
CATHETER MOUNT WITH CONNECTORS (ISI/CE) • Should have low dead space • Design should comply ewith medical breathing system and circuits • Non Conductive • Light weight reusable type • Able to withstand hospital disinfectants
BAINS CIRCUIT (IS/11363- CE /ISO) • Material should be Latex free medical grade plastic, disposable non-irritant to tissues & should not react with anesthetic agent and gases. • Length-1.6 mtrs. • Outer diameter (OD) 22 mm. • Inner tube 7 mm diameter • Size of Connectors- 22 mm & 15 mm. • Expiratory Valve-Heid brings tube (Spring Loaded) Provision for scavenging system attachment with minimum resistance. • Inner & Outer tube should be properly aligned and fixed at the patient end. • Bag natural latex rubber antistatic, 21 capacity, soft should not react with anesthetic agent and gases 22 mm ID bushing, Circuit should be expandable, non-kinking type.
CLOSED CIRCUIT (PAEDIATRIC) (IS-11363/CE/ISO) • Light Weight • Adult-1.75 mtr. Length, double tubing with a Y connection with least dead space. • Y connection adopter 15 mm to 20 mm connecter. • Latex free medical plastic material disposable non-irritant to tissue and should not react with anaesthetic gases and agents. • Outer diameter (OD) 10-12 mm • Bag1 L. Capacity, natural latex medical grade rubber, antistatic, soft & should not react with anaesthetic gases & agents. Expandable type non-kinking tube.
NASAL OXYGEN CATHTER • Twin bore nasal oxygen tube with nasal spike. • Tube length 2.0 mtrs. long. • Pre sterilized and should be non toxic • Size :- Neonatal
NASAL OXYGEN CATHTER (Specification as 19.0) • Size :- Adult
NASAL OXYGEN CATHTER (Specification as 19.0) • Size:- Pead.
HEAT SENSITIVE PAPER TAPE FOR STERILATION A roll of tape on a 2-4 inches diameter core to be used to secure package going into an autoclave (with a vacuum cycle ) which change colour ( on being exposed to temperature of 121C to indicate sterilization procedure is complete .It should BE 19mm to 25 mm wide and the roll should be having length of 40-60meters
MEASURED VOLUME SET (ISO/CE) Specification as under:- • Should be made up of PET material • Soft cylindrical type measured volume chamber with float valve to prevent air embolism. • The set should have transparent tubing and chamber. • Drips nozzle with reduced size of drop that has to be uniform at 60drops /ml. • Moulded bubble latex bulb for extra medication or Y port for injection. • Sterile ready for use. • Double pack. • Built in airway for bottle perforating spike (air vent) • Capacity of 100 ml
MEASURED VOLUME SET (ISO/CE) (Specification as 21.0) • Capacity of 150 ml
VENTI MASK ADULT for administration of oxygen with provision for verifying F1O2 - 24%, 28%, 31%, 35%, 40% & 60% From the same device Good quality, Soft mask with strap with different color coded venturi devices Full set of color coded Oxygen diluters
T.U.R. SET • Y Shaped set for endoscopic irrigation • Thumb operated clamp • Proximal end fitted with flexible latex • Manufactured fromnon –toxic ,non irritant medical grade PVC • Individually packed in peel able double pouch pack • Sterile ready for use • Disposable • Should have 2.14 G needles with cover and short plastic at their ends • Easy Operation of clamp with full closure of water flow
I .V. SET (ISI/CE/ISO) Specification as under:- • Set should be manufactured from medical grade non-toxic PVC, siliconized. • Cylindrical type molded drip chamber provided with disc filter, sharp spike & built in air-vent. • Roller type flow controller for accurate flow control. • Molded bubble latex bulb for extra medication/ or Y-Port leak –proof junction. • Extra smooth 21 G vein needle. • Gamma Rays Sterilized- Indicator to be or ETO Sterilized displayed on the Carton. • Air vent attached with Chamber. • Ready for use. • Double packed. Tube length not less than 1500 mm and diameter of inner side not less ,IS standard (with 1500 mm length, not less than 2.7 mm) Nonkinkable and disc filter size should be not less than 15.00micrometer according to ISI standard should be accompanied by Sterility and pyrogen free report
Mini Vac Suction Drain Size: 6
Mini Vac Suction Drain Size:8
Arterial Cathter (22G) (CE marked) • Polywethane Cathetre radio opaque • Straight Guide Wire. • Introducer needle 21(G) • 50 X 50 Drop sheet. • Size : 22 G- 4cm .
Arterial Cathter (22G) (Specification as 26.0) • Size : 22 G- 6cm
Arterial Cathter (22G) (Specification as 26.0) • Size : 22 G- 8cm
Arterial Cathter (22G) (Specification as 26.0) • Size : 22 G- 20cm
FENESTRATED TRACHEOTOMY TUBE SYSTEM WITH SUBGLOTTIC SUCTION FOR VENTILATED PATIENT • Should have fenestrated cuff tube Fenestration should be just above the cuff • Should have standard cannula, decannulation plug , soft touch holder should be supplied with subglottic suction cannula • Size: 4 No.
FENESTRATED TRACHEOTOMY TUBE SYSTEM WITH SUBGLOTTIC SUCTION FOR VENTILATED PATIENT (Specification as 27.0) • Size: 6 No.
FENESTRATED TRACHEOTOMY TUBE SYSTEM WITH SUBGLOTTIC SUCTION FOR VENTILATED PATIENT (Specification as 27.0) • Size: 8 No.
FENESTRATED TRACHEOTOMY TUBE SYSTEM WITH SUBGLOTTIC SUCTION FOR VENTILATED PATIENT (Specification as 27.0) • Size: 10 No.
Twin bore O2 &CO2 Sampling cannula • Should have divider in the middle of both ports to allow simultaneous delivery of oxygen & sampling of expired CO2 gas from both snares. • Should have flexible contoured cannula for patient comfort. • Should have over the ear fit secure position on the patient. • Should have luer lock connector to connect to any side stream CO2 monitor. • Sizes – Adult
Twin bore O2 &CO2 Sampling cannula (Specification as 28.0) • Sizes – Paed.
Intubating mask laryngeal airway (USFDA) • It should be reusable and made of silicon material, autoclave able up to 60 times with tethered connector, • Integrated bite clock. • Build up mask heal for better seal. • Elevated ramp to facilitate ETT insertion of normal PVC endotracheal tube. • Horizontal ridges inside the mask cavity • Individually blister pack . Presterilized ready for use. Size: 0.5
Intubating mask laryngeal airway (USFDA) (Specification as 29.0) Size: 1
Intubating mask laryngeal airway (USFDA) (Specification as 29.0) Size: 1.5
Intubating mask laryngeal airway (USFDA) (Specification as 29.0) Size: 2
Intubating mask laryngeal airway (USFDA) (Specification as 29.0) Size: 2.5
Intubating mask laryngeal airway (USFDA) (Specification as 29.0) Size: 3.5
Intubating mask laryngeal airway (USFDA) (Specification as 29.0) Size: 4.5
STRAIGHT PLASTIC CONNECTOR TO CONNECT ENDOTRACHEAL TUBE WITH THE AESTHESIA CIRCUIT • Made of transparent plastic Provision for monitoring Et CO2 i.e. connection for side stream tubing
HEM-O-LOK Endo appliers for Laproscopic surgery • The shaft of the applier should have a diameter of 10 mm for Large size clips • The shaft of applier should have a diameter of 5mm for Medium Large clips.
Double J Stent • Polyurethane with hydrophilic coating • Completely radio-opaque • Continuous black positioning line to indicate direction of tip coil • Both ends open, tapered at upper end • Drainage holes every 5-20mm • Markings at every cm and heavy marking every 5 cm • Sterile, single use • Plastic pusher of 40 cm or longer • CE 1023 or FDA (510 K) equivalence certified • Sizes: 6Fr./26cm
Double J Stent (Specification as 33.0) Size: 4.8Fr. or 4.7Fr./26cm
Double J Stent (Specification as 33.0) Size: 4.8Fr. or 4.7Fr./20cm
Double J Stent (Specification as 33.0) Size: 4.8Fr. or 4.7Fr./16cm
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (ISO 9002 OR CE marking) • Should confirm to ASTM- F623-99 Guideline • Specifications for Foley’s catheter • Double pack sterilized, ready for use • Capacity of balloon 30-to 50ml; should symmetrical on inflation • Balloon on inflation should not compress the drainage lumen with no decrease flow on full inflation • Rounded tip burr free perforations, short tip • Should have unidirectional syringe port on inflation channel • Manufactured from Non-Toxic, Non-Irritant, Medical Grade Pure Silicone. • Size: 12
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (Specification as 34.0) Size: 14Fr.
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (Specification as 34.0) Size: 16Fr.
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (Specification as 34.0) Size: 18Fr.
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (Specification as 34.0) Size: 20Fr.
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (Specification as 34.0) Size: 22Fr.
Full Silicon FOLEY’S CATHETER (TWO WAY) ADULT SIZES (Specification as 34.0) Size: 24Fr.
Disposable ECG Electrode (Paediatric) • Pediatric and adult Electrodes should be quoted separately. • Electrodes should a good sticking material, solid gel, covered by translucent/ transparent thin sheet. • Should be hypo allergic & Certificate should be attached. • Sensor should be good quality, preferably of silver • Should be usable even if the chest is hairy • Should have buttons (Metal snap: stainless steel stud) for attachment to ECG electrodes. • Should have white label indicated brand mark. • Should not be affected by high temperature during summer.
K Wire • Size: 3mm
K Wire • Size:2.5mm
K Wire • Size: 2mm
K Wire • Size: 1.5mm
K Wire • Size: 1mm
Troponin T/ I Kit • Should give qualitative essay of Troponin T or Troponin 1 with the result given as positive or negative within a short period of 15-20 minutes. • Should be possible to measure Troponin T/I using only the kit and whole blood. No other reagent should be needed. • Should be packed as a single unit containing the kit and the pipette with the name of the company as well as product name mentioned on the cover of the packet. The name of the kit or the name of the company should also be mentioned on the kit. • The threshould of Troponin value for showing the result as positive should be <0.15 ng/mL • Should be supplied with Control Kit (one control kit for every 20 assay kits)
Stomach Wash Tube • Required to be used for performing gastric lavage in patients with acute poisoning by siphoning method or by using a suction bulb which allows only outward movement of fluid instilled into stomach • Should be made of non-toxic PVC or rubber • Distal End opening are smoothly contoured enables more comfortable for insertion • Four large lateral eyes for free-flowing movement for effective drainage • Color-codied connector at proximal end for instant identification of catheter size • Graduated markings at various lengths from the tip for accurate placement • Various sizes from 20Fr to 36Fr. with total length of 12 cm • Sterile, individual peel pouches for single-patient use • Available with mouth bite
Adult MR Compatible ECG carbon electrodes. • Should be MR compatible (for both adult and pediatric application) for magnetic fields at 1.5 Tesla MR scanners. • Should have Ag/AgCI Redox or any approved resistance (electrodes) for use with 1.5 3.0 Tesla MR Scanners. • Should comply with common European guidelines (CE) and or FDA approval / guideline and submit a copy of their approval. • Should not produce any RF Artifacts and any other MR related heating to the patients. • The ECG pattern should be comparable to that of non MR electrodes and their recordings and should have minimal magnetic field interactions. Provide documents for the same. Should not produce any other artifacts during imaging process due to magnetic fields, gradient magnetic field, Rf etc. • Should not produce any other artifacts during imaging process due to magnetic fields, gradient magnetic field, RF etc. The vendor should supply sample electrodes for adult and pediatric application and these will be tested at 1.5T and 3.0 T MR Scanners in the department and only after satisfactory performance, demonstration and acceptance, the tender will be technically short listed.
Paediatric MR Compatible ECG carbon electrodes. (Specification as 39.0)
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle • Size: 21G x 1”
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle • Size: 22G x 1”
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle • Size: 23G x 1”
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle • Size: 24 x 1”
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle Size: 23G x 1.5”
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle Size:- 24x1.5”
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle Size: 25G x 1.5"
DISPOSABLE NEEDLES (1SI/ISO/CE) • Presterilzed, color-coded, Packed in single protective sheath. • Needle made up of Stainless Steel medical grade. • Beveled sharp point tapering < 12 degree + 2 degree angle Size:- 26G x 1.5”
Disposable Syringe with Needle (Sterilized) (ISI/ISO/CE) • sizes: 5 CC
Disposable Syringe without Needle (Sterilized) (ISI/ISO/CE) • Size 50 CC
Disposable Spinal Needle with introducer (Paediatric) USFDA/CE European mark • Should have Pencil Point Tip with lateral opening for smooth flow of alocalaes the tic drug. • Should have clear & magnifying hub for quick & scanty identification of CSF Flashback. • Introducer should be compatible with size of the spinal needle. • Should bea available in following sizes: /length-24G/3.5cm.
Disposable Syringes with Needle with leur lock (Sterilized) (ISO) • Reuse prevention breakable plunger syringe with possibility of multiple aspirations, • Size: 2 ml
Disposable Syringes with Needle with leur lock (Sterilized) (ISO) • Reuse prevention breakable plunger syringe with possibility of multiple aspirations, • Size: 5 ml
Disposable Syringes with Needle with leur lock (Sterilized) ( ISO) • Reuse prevention breakable plunger syringe with possibility of multiple aspirations, • Size: 10 ml
Disposable Syringes with Needle with leur lock (Sterilized) ( ISO) • Reuse prevention breakable plunger syringe with possibility of multiple aspirations, • Size: 20 ml
Disposable Syringes with Needle with leur lock (Sterilized) ( ISO) • Reuse prevention breakable plunger syringe with possibility of multiple aspirations, • Size: 50 ml
DISPOSABLE INSULIN SYRINGES 1CC( 40 UNITS) WITH NEEDLE Size: 30x½
Bibag (Bibag which is compatible to use in 5008S Machines) Specifications:- • Surface area = 1.3 M2 – 1.8 M2 • Blood priming volume = 80 ml to 110 ml • Blood flow range 150ml/min to 400 ml/min • UF co-efficient = 40 ml/hr mmHg to 44 ml/mmHg • Maximum TMP – 500 mm/Hg to 600 mm/Hg • Dialyser membrane – Polysurfaone • Sterilization Method – Inline steam sterilization
High Flux Dialyzers Specifications:- • Arterial and venous tubings (separate) • Arterial and venous tubings should have different colour coding of dialyser connector • Artierial tubing should have red colour coding • Venous tubings should have blue colour coding • Arterial tubrings should have sampling port to collect blood sample • Arterial tubings should have a blood pump segment • Blood pump segments inner diameter should be 8.00 mm
HDF Tubing (Tubing which are compatible to use in 50085 Machines) Specifications:- • Arterial and venous tubings (separate) • Arterial and venous tubings should have different colour coding of dialyser connector • Artierial tubing should have red colour coding • Venous tubings should have blue colour coding • Arterial tubrings should have sampling port to collect blood sample • Arterial tubings should have a blood pump segment • Blood pump segments inner diameter should be 8.00 mm • Arterial tubings should have heparin delivery line • Arterial tubings should have pressure dome to measure arterial pressure • Venous tubings should have injections port • Venous tubings should have vernous bubble catcher (venous chamber) with pressure line having transducer protector. • Both tubings should have luer lock patient connector with colour code • Tubings set should have priming/rinse connector (recirculation connector) • Sterilization by – Beta Sterilization – DEHP free • Filling voume of tubings – 132 ml • Diameter of venous bubble catcher 22 month • Tubings set should have substitution fluid pump segment with substitution connector and drainage connector
Paediatric Caudal Needle Caudal needle with Crawford tip 45 deg with graduations & depth stop Size - 23 G X25mm.
Paediatric Caudal Needle (Specification as 60.0 Size - 22G X 40mm.
PHARMATEK INDIA
Hospimax Healthacare Pvt. Ltd.
Vijay Surgical Corporation
BBraunMedical India Pvt Ltd
M/s Standard Traders
S.S.ENTERPRISES
M/s Oriental Surgical Works
PIONEER ASSOCIATES
Romsons Scientific And Surgical Industries Pvt. Ltd.
Delhi Pharma
Mex India
ANSH HEALTHCARE
MEDI NEEDS INC
paras surgical co.
ARIAN HEALTHCARE
MEDISERVE
MEDI NEEDS INC
ANSH HEALTHCARE
S.S.ENTERPRISES
PIONEER ASSOCIATES
Delhi Pharma
MEDISERVE
Romsons Scientific And Surgical Industries Pvt. Ltd.
Mex India
M/s Standard Traders
Ranjeet Enterprises
PHARMATEK INDIA
Vijay Surgical Corporation
paras surgical co.
stage.html
html • 0.07 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .