| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC | L1 | Accepted-AOC L1 bidder lowest | |
| 2 | L2₹17.5 L+₹84,602 (5.07%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹21.1 L+₹4.4 L (26.3%)Rejected-Finance MAIN ROAD RANJHI JABALPUR 482005 M P | JABALPUR | MADHYA PRADESH | 482005 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹22.1 L+₹5.4 L (32.6%)Rejected-Finance PLOT NO 81 SHANTAJI COLONY JANKI NAGAR JABALPUR MP PIN 482002 | JABALPUR | MADHYA PRADESH | 482002 | L4 | Rejected-Finance Other than L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
26 Dec 2020, 6:00 pmClosed
GE (West) jabalpur
Garrison Engineer (West) Jabalpur Supply Marg Post Box No. 54 Jabalpur Cantt-482001 (MP)
REPAIRS TO STREET LIGHT AND CONNECTED LT UG CABLE FITTING FIXTURE PANEL AND OTHER CONNECTED WORKS FOR MAP ACCN AREA UNDER GE (WEST) JABALPUR
2020_MES_399275_1
8291/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (West) Jabalpur
As per Tender documents
5 documents required · 5 mandatory
₹500
GE (West) Jabalpur
₹50,000
6 Jan 2021
28 Nov 2020
28 Dec 2020
28 Nov 2020
26 Dec 2020
12 Dec 2020
30 Nov 2020 - 10 Dec 2020
Amount
Excavation in trenches for laying under ground cable, errection of poles and stays in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep and getting out complete all as specified and directed by Engr–in–charge.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge.
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
Removing surplus excavated material to a distance not exceeding 50 meter above the starting point complete all as specified and directed by Engr in charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed by Engr in charge.
Repair and maintenance of street light / perimeter light / security light / Garden lights/ flood light fitting HPSV/LED any type/make installed on LT / HT poles, building by means of replacing any unserviceable parts as and when required complete with labour including taking down, dismantling, reassembling and re-fixing the fitting at its original location with proper alignment and making good all defects including replacing of nuts/bolts/PVC connections etc and keep the light fitting in working condition through out the period of contract at one time payment complete all as specified and directed. Note :- Defective / worn out parts/ fittings measured and paid seperately as supply only relevant items.
Repair and maintenance of High mast light fitting any type/make installed on HT poles,by means of replacing any unserviceable parts as and when required complete with labour including taking down, dismantling, reassembling and re-fixing the fitting at its original location with proper alignment and making good all defects by replacing nuts/bolts/PVC connection etc and keep the light fitting in working condition through out the period of contract and one time payment shall be made for the same complete all as specified and directed. Note :- Defective / worn out parts/ fittings measured and paid seperately as supply only relevant items.
Supply only HPSV Lamp of capacity 70 W
Supply only HPSV Lamp of capacity 150 W
Supply only HPSV Lamp of capacity 250 W
Supply only HPSV Ballast of capacity 70 W
Supply only HPSV Ballast of capacity 150W
Supply only HPSV Ballast of capacity 250 W
Supply only HPSV igniter of capacity 70/150/250/400Watt
S&F in replacement of GI pipe bracket ,made out of GI pipe 40mm dia light grade 1.5mtr long bend to the shape 120 degrees angle all as per site requirement including MS clamps made of F1 50x6mm complete with nuts, bolts & washer as per requirement for mounting fittings.
Supply & fixing in replacement connecting PVC insulated, round,sheathed, multicore, industrial flexible cable with bright annealed copper conductor, 1100 volts grade cable of size1.5sqmm, 3 core, confirming to IS 694-1990 complete all as specified and directed
Supply & fixing in replacement connecting LED top post lantren, decorative luminaire with diffuser, 240 volts, 50 Hz, 35-45 watts with mounting arrangement incl taking down of existing fitting complete all as specified and directed by the Engr-in-charge of Make : Cat No C&S - (APUS/40W) LT GL 40WHPLED/W, Bajaj - BRIL45WLED NW , Surya SLEPT 40 W -ETPP
Supply fixing in replacement connecting LED street light fitting 60-75 Watt having LED as light source, optical system, heat sink and drivers into one compact housing which ensure the LEDs have a long life, colour temperature - cool white (5700K) , nominal voltage 240 voltage, system efficay >75lm/W, pressure die cast aluminium housing, gear-integrated electronic driver, CRI - 70, protection IP-65/66, class - I complete all as specified and directed by the Engr - in - charge. Make - C&S Cat Part No INDUS/70W/LS LTESS30x2.5HPLED/LS or Wipro Cat part No LR02-671-XXX-57-XX or Bajaj Cat Part No 169900 BRTFG 75W LED I
Supply & fixing in replacement connecting LED street light fitting 45-60 Watt having LED as light source, optical system, heat sink and drivers into one compact housing which ensure the LEDs have a long life, colour temperature - cool white (5700K) , nominal voltage 240 voltage, system efficay >75lm/W, pressure die cast aluminium housing, gear-integrated electronic driver, CRI - 70, protection IP-65/66, class - I complete all as specified and directed by the Engr - in - charge of Make : C&S -INDUS/45W/LS LTESS18x2.5HPLED/LS, Surya - SLEUL48WIP66LXN & Bajaj - BRTFG60WLEWU3WW
Supply fixing in replacement connecting LED street light fitting not less than 25 Watt having LED as light source, optical system, heat sink and drivers into one compact housing which ensure the LEDs have a long life, colour temperature - cool white (5700K) , nominal voltage 240 voltage, system efficay >75lm/W, pressure die cast aluminium housing, gear-integrated electronic driver, CRI - 70, protection IP-65/66, class - I complete all as specified and directed by the Engr - in - charge of Make Cat No C&S INDUS-E/25W LTESSE2SW LED, Bajaj - BCLST30WLED-1, Surya - SLEUL25W1066LXN
Supply & fixing in replacement connecting LED flood lights, not less than 100 watt, having high power LED and unique flood optics to enusre uniform distribution system, colour temperature cool white (5700K), system efficay >80 lm/watt, pressure die cast aluminium housing, integrated electronic driver, IP-65, Class I complete all as specified and directed by the Engr-in-charge of Make - Surya - SLEFL100WIP66LUMOS , C&S - ORIOM -3.0/100W LTEF100WHPLED & Bajaj - BJFL120W LED - 1
Supply and fixing in replacement of decorative gate light made up of high grade unbreakable polycarbonate material suitable for retrofit B 22 base LED of 20 watt all as specified and directed of Make LHFXBON1TN5Q020 of Havells of equivallent make, Make for LED lamp 20 watt- Philiphs or Equivalent make as approved by the GE
Supply & fixing in replacement of connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw single phase load with contactor 63 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 63 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 16sqmm coper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts complete incl taking down of existing arrangement all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw1P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
Dismantling/ taking down of existing street light switching system and Supply, fixing, connecting and testing of Automatic Street light switch using infrared Sensor based Nature Switch for automatic switching of street lights, Nature switch operation should be based on Natural light lux level. Required illumination level for switching on is < 30 lux and for switching off > 10 lux. The sensor should also have part night operation facility for 4 - 12 hours. The sensor alongwith suitable power contactor, incoming-outgoing MCBs should be enclosed in a pole/wall moutaed enclosure made out of Rust proof, electric shock proof, termite proof and FR grade SMC junction box conforming to IP-54, The circuit should be suitable enough to take 8 kw Three phase load with contactor 25 Amps conforming to IEC-60947-4-1/IS-13947-4-1 & incoming and outgoing MCBs of rating 32 Amps conforming to IEC-60898/IS-8828 and circuit wiring of minimum 10sqmm copper conductor wire in and including providing of 50x6mm flat iron clamp, necessary nuts and bolts, complete all as specified and directed by the Engr-in-charge. Make of nature switch - Model No Swadeep-02EC8kw3P of Kakatiya Energy System or equivalent make of Bajaj/Healer, Make for Contactor- BCH/L&T/Schneider, Make of MCBs- Hager/Schneider/L&T/C&S, Enclouser - Sintax or equivalent
Supply and fixing in replacement of non dimmable LED lamp 7 watt, B22 base, 6500K, 600 lumen complete Make Philips or equivalent model of Havells, Crompton Greaves
Supply and fixing in replacement of non dimmable LED lamp 50 watt, B22 base, Lumen flux -4500lm, CCT-6500K,PF>0.90 complete Make Philips or equivalent model of Havells, Crompton Greaves
Supply and fixing in replacement of Holder B-22 base, Plastic body, suitable for B-22 base 45 watt LED lamps Make Anchor, HPL, Plaza
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 31 of 9 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified in IS and all as shown in drawing No CEJZ/TD/824/91, Sheet No1/2 dt 16.04.91 including taking down existing poles and removal to store with following specifications:- (i) Excavation in trenches in any types of soil ,returning filling in & well ramming including watering and disposal of surplus soil to a distance not exceeding 50 mtr from the starting points. (ii PCC (1:4:8) type D2 using 40 mm graded crushed stone aggregate as in foundation bedding all as specified and directed . (iii) PCC (1:3:6) type C-2 using 40mm graded crushed stone aggregate as upto ground level. (iv) PCC (1:2:4) type B-2 using 20mm graded stone aggregate as in coping including necessary form work. (v) Writing pole No with yellow shade on black base using synthetic enamel paint having height of words exc 5 cm as directed by Engr-in-charge incl dismantling of old pole.
Drilling (Horizontally) existing road ( Maximum 1 mtr wide) suitable for passing GI tubing upto 80/100mm complete all as specified and directed.
Trimming of tree branches Clearing of LT/HT line 4 mtr all around by cutting tree branches at ground level of any numbers and any girth on any numbers of conductors/earth wire complete all as specified and directed by Engr in charge.
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size 200 x 160 x 98 mm, 5 way having terminals for termination of cable with necessary nuts and bolts ,Make - Hansal including -02 Nos polycarbonate cable gland Make :Hansal, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps Make - Legrand in and including fixing clamp of FI 50 x 6mm with necessary nuts and bolts complete in and including taking down of existing u/s junction box of any type all as directed.
S&F in replacement 3 Layer PPR Pipes, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing FI clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from junction box to light fittings, complete for outer dia 20 mm (PN-16) Make : SFMC / WET FLOW /AQUA
Supplying and fixing in replacement of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular. Make - Plaza/Polycab/ Finolex
Supply, laying or fixing or passing through pipe commissioning and testing of PVC / XLPE insulated, armoured heavy duty, electric cable with aluminium conductor, 1100 volts grade of the following cross section area including suitable size lugs including taking out /dismantling of existing cable. Note:- Excavation & earth work, sand cushioning, bricks protection & GI pipe where required shall be measured & paid separately under relevant items:-
(a) 10 Sqmm 2 core
(b) 16 Sqmm 4 core
(c) 25 Sqmm 4 core
(d) 35 Sqmm 3.5 core
(e) 50 Sqmm 3.5 core
S&F in replacement of GI Tubes, of following size, light grade ,galvanised , with clamp of 25x3 flat iron welded to pipe fixed to wall/pole/ceiling or laid in floors or under road etc complete all as specified and as directed.
(a) 40 mm bore
(b) 50 mm bore
Dismantling of old unservicable bus bar chamber and S&F Design, supply, erection, testing and commissioning of outdoor type LT Bus Bar Chamber box, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type Aluminium bus bars (32mm x 5mm) for looping & branch connection system .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 7 tank pre-treatment of surfaces. The bus bar chamber shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947.
The bus bar chamber shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (01 layer) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom. The bus bar chamber shall be provided with ventilation facility in the form of louvers for better heat dissipation.
(Note : The bus bar chamber Box shall be designed in such a way that adequate workable space is made available inside the compartments and the size of the chamber shall not be less than 500mm height (without base frame & canopy), 500mm width and 450mm depth).
Supply and fixing MCCB 4 pole 100 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 160 Amps rupturing capacity 16 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 200 Amps rupturing capacity 25 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 250 Amps rupturing capacity 36 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 315 Amps rupturing capacity 35/36 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 400 Amps rupturing capacity 50 KA with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Supply and fixing MCCB 4 pole 630 Amps rupturing capacity 50 KA, with connecting links on LT panel/feeder pillar including dismantling/taking down existing unserviceable MCCB complete all as specified and directed.
Material and labour for painting to steel tubular pole/Rail Pole of HT/ LT over head line and all MS clamps, cross arm work on poles with one coat of superior aluminium paint including necessary preparation of surfaces and painting of alternate strip with black and white synthetic enamelled paint strip 05 Nos each of 30 cm height up to 1.5mtr above PCC benching/coping complete all as specified and directed by Engr in charge
Scrubbing of existing paints of existing LT panel board, LT feeder Pillar boxes, LT bus bar chamber paints of any specification and removing old paints and preparation of surfaces for painting complete and M&L for painting of LT Panels, LT Feeder pillar boxes, LT bus bar chambers internaly and externaly with one coat of superior quality smoke grey paint to achieve fine finishing complete all as specified and directed by Engr - in charge at site.
Dismantling of old unserviceable doors, back sheets, side sheet of LT panels, bus bar chamber or feeder pillar box installed at various places by cutting/descrewing after making the system disconnected from Elect supply and M&L for fabrication of doors/frames/ partition, bottom sheet by bending hot or cold, making holes, notching, welding of MS black sheet for LT panel board, bus bar chamber, feeder pillar box made out of 2 mm thick mild steel sheet including providing hinges for opening or closing of door, making handles, locking arrangement and painting of sheet both side with superior quality smoke grey paint after applying a coat of red oxide and matching with the existing complete all as specified and directed by the Engr - in-charge at site. Note : The cost of disconnecting of LT cable and earth strip and reconnecting the same after repair work shall be deemed to be inclussive in the unit quoted rates.
Taking out old unserviceable LT XLPE / PVC insulated armoured cable of any size from trenches wall/roof including taking out of brick layer and sand from trenches itc for checking its serviceability for reuse and relaying the same after repair the cable after jointing the cable all as required and directed at siet and as specified and as directed. Note : straight through joint and other material will be paid seperately.
S&F in replacement of straight through joint LT from 25 sqmm 3.5/4 core to 70 sqmm 3.5 core with jointing all as required and directed at site
S&F in replacement of straight through joint LT from 95sqmm 3.5 core to 120 sqmm 3.5 core with jointing all as required and directed at site
Supply and spreading the stone aggregate of 40 mm size spreading in the substation/ as where directed at site
Material and labour for providing cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling in and including demolition of existing PCC complete all as specified and directed by Engr in charge.
Material and labour for providing cement concrete 1:2:4 type B-1 (using 20 mm graded crushed stone aggregate) for coping of poles including necessary form work and finished the surface complete in and including demolition of existing PCC all as specified and directed by Engr in charge.
Disconnecting, dismantling of old unserviceable motor control panel/ Feeder pillar box and Design, supply, erection, commissioning and testing of indoor type motor control centre, suitable for 25 HP, submersible motor pump set, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 200 Amps, looping & branch connection system shall be made with suitable rating copper bus bar/ suitable size copper wire having sleeves of colour coded .The Motor control panel shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The submersible motor control Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The motor control Panel shall be made out of 2mm thick CRCA mild steel sheet and 2.00mm thick gland plate , front side operable, single door and rear Door (01 layer) opening facility, mild steel channel (75 MC) base frame at bottom. All incoming/outgoing MCCBs/ starter shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings :
CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.
CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables, Make of LT Panel : Mc Layer Pvt Ltd, Tricolite, Asian Switchgear
INCOMING :- (a) MCCB 100 Amps, 4 pole, 415 volts, 25 kA, 50 Hz, adjustable, electronic release Make Legrand , ABB, Seimens - 01 Nos
(b) Change over switch 4 pole, on load type, 100 Amps, front operated, 415 volts, 50 Hz, of reputed manufacturer,
OUTGOING : (a) MCCB 50 Amps, 3 pole, 415 volts, 50 KA, 50 Hz, , Ics = 100%Icu, Make Legrand, ABB, Seimens - 01 Nos
(b) Motor starter suitable for 25 HP submersible pump set, fully automatic, star delta - 01 Nos
(c) three phase auto phase changer - 01Nos and single phase preventor -01 Nos suitable for 25 HP submersible pump set, fully automatic, star delta - 01 Nos
(d) Motor protection relay model No MM 30W of L&T, numeric type, having function , trip circuit supervision, thermal Over load and pre alarm, Locked rotor, current unbalance, phase reversal, phase loss, over current, earth fault, repeat and prolonged starts, restar inhibition, No load running, blocking function, under frequency, over frequency, under voltage, overvoltage, running hours, low PF with all connected items like contactor, auxilary DC supply, suitable size powerpack/bty required to make the relay functional in all respects
(e) Auto timer suitable for 25 HP submersible motor pump set, MakeL&T, Legrand, C&S, ABB
(f) GPS based monitoring system complete with all connected items, MakeL&T, Legrand, C&S, ABB
(g) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos
Make : Legrand, L&T, Hager, Havells
(h) Digital Ammeter 96mm x 96mm suitable to read 0 to 200 Amps, accuracy class 1% - 01 Nos
Make : L&T, Hager, Havells
(g) Current transformer (CT) of rating 200/5, tape wound, rated burden 5 VA - 03 Nos
(h) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01)
Make : CG/L&T/Siemens
(j) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos
(l) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No.
(m) Danger Notice Plate -02 Nos
(n) Pannel box made up of CRCA mild steel 2.0mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 2.5 Sqm front area) ' Make of Panel - Asian Switchgear/ Tricolite/Universal Switchgear/ Mc Layer Pvt Ltd
Note :- Panel shall be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurementof LT panel for approval alongwith CPRI approval. Foundation will prepared as per instruction and rate of fondation deemed to be included in the quoted rates.
Earthing complete with galvanised steel earth plate electrode 60 cm x60 cm x 6 mm thick buried directly in ground ,(Earth pit not less than 2.25 meter deep below ground level) with top edge of plate not less than 1.5 meter below normal ground level ,connected to and including galvanised iron earth wire 32 X 6 mm by means of nut, bolts, check nuts and washers of galvanised iron or steel and provision of charcoal dust and common salt packed all around the earth plate including necessary excavation and earth work in any type of soil and testing complete all as specified and directed and shown in electrical plate number 5 of MES SSR part-I(1991) (a) Excavation and earth work for drilling hole for electrode in any type of Soil. (b) PCC pit in cement concrete 1:2:4 type B-1, Pre cast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than1.87 Kg/ Sq meter. (c) Funnel with watering pipe of GI 20 mm nominal bore light grade and lugs etc complete all as specified and directed (d) 40 mm nominal bore medium grade GI protection pipe 5 meter long for protection of earthing lead complete all as specified and directed. (e) Requisite quantity of common salt and charcoal. (f) Testing of earthing.
R K TRANSFORMER
RAVINDRA ELECTRICAL
shri krishna traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .