Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC | L1 | Accepted-AOC LOWEST AND REASONABLE | |
| 2 | L2₹19.0 L+₹8,680 (0.46%)Rejected-Finance 42 B INDRA NAGAR SRINAGAR J K 190004 | SRINAGAR | SRINAGAR | J K | 190004 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹19.1 L+₹18,880 (1.00%)Rejected-Finance DHOBI MOHALLA BATMALOO SRINAGAR 190010 J K | SRINAGAR | SRINAGAR | J K | 190010 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹19.2 L+₹21,240 (1.12%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹19.6 L+₹61,160 (3.23%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹23 L
EMD Value
₹46,000
Closing Date
28 Nov 2020, 6:00 pmClosed
GE 864 EWS
GE 864 EWS SRINAGAR PIN - 190004
REPAIR REPLACEMENT SUBMAIN WIRING ALONGWITH VTPN DB AT VARIOUS LOCATION AT BB CANTT SRINAGAR
2020_MES_389322_2
864/WS-34/2020-21
Open Tender
Miscellaneous Works
Item Rate
270 days
BB CANTT SRINAGAR
Please refer Tender documents.
7 documents required · 7 mandatory
₹5
GE 864 EWS
₹46,000
Yes
22 Jan 2021
7 Nov 2020
30 Nov 2020
7 Nov 2020
28 Nov 2020
14 Nov 2020
Amount
Taking down carefully existing aluminium / copper submain wiring on batten or in PVC conduit or in MS conduit with earth wire etc., complete and making good the disturbed surfaces of walls, floors, ceilings etc. to match with existing surfaces, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts, 3 Phase, 50 C/s, 4 way complete with appropriate size copper busbar and neutral link confirming to Cat Part No. 607913 of Legrand or technocommercially equivalent make of L&T / Standard, complete with one MCCB 4 Pole, 415 Volts, 100 Amps rating with rupturing capacity 16 KA and 12 Nos of MCB SP 63 Amps of the same make as of distribution board and including cutting chases to wall for fixing DB and making good the disturbed surface to match with existing surface all as required at site, complete all as specified and directed by Engineer-in-Charge. Note :- Outgoing MCBs will be measured and paid saperately under respective items.
S&F in replacement distribution board iron clad, double door with IP-43 1K-09 protection suitable for MCCB as incommer and MCB as outgoing 415 Volts, 3 Phase, 50 C/s, 4 way complete with appropriate size copper busbar and neutral link confirming to Cat Part No. 607913 of Legrand or technocommercially equivalent make of L&T / Standard, complete with one MCCB 4 Pole, 415 Volts, 125 Amps rating with rupturing capacity 16 KA and 12 Nos of MCB SP 63 Amps of the same make as of distribution board and including cutting chases to wall for fixing DB and making good the disturbed surface to match with existing surface all as required at site, complete all as specified and directed by Engineer-in-Charge. Note :- Outgoing MCBs will be measured and paid saperately under respective items.
S&F in replacement sheet metal enclosure double door for mounting MCBs with 200 Amps rated bus bar, 12 way, AC 240 Volts with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed surfaces to match with existing surfaces, complete all as specified and directed by Engineer-in-Charge. Make :- L&T / HPL / ABB
S&F in replacement sheet metal enclosure double door for mounting MCBs with 200 Amps rated bus bar, 8 way, AC 240 Volts with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed surfaces to match with existing surfaces, complete all as specified and directed by Engineer-in-Charge. Make :- L&T / HPL / ABB
S&F in replacement sheet metal enclosure double door for mounting MCBs with 200 Amps rated bus bar, 4 way, AC 240 Volts with IP-43 protection including cutting chases to wall for fixing DB and making good the disturbed surfaces to match with existing surfaces, complete all as specified and directed by Engineer-in-Charge. Make :- L&T / HPL / ABB
S&F MCB SPN 40 Amps, 240 Volts, 50 Hz AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. Make :- L&T / HPL / ABB
S&F MCB SPN 63 Amps, 240 Volts, 50 Hz AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. Make :- L&T / HPL / ABB
S&F MCB SP 6-32 Amps, 240 Volts, 50 Hz AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 10 KA breaking capacity, complete all as specified and directed. Make :- L&T / HPL / ABB
S&F MCCB 3 Pole 100 Amps with magnetic / thermal fixed setting 16 KA complete including connecting brass terminals etc., complete all as specified and directed. Make :- L&T / HPL / ABB
S&F MCB SP 63 Amps current carrying capacity, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, complete all as specified and directed. Make :- L&T / HPL / ABB
M&L for repair/replacement submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2x4 Sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 2.5 Sqmm as earth lead in and including PVC conduit / casing & capping and making good the disturbed wall surfaces to match with existing specifications, complete all as specified and directed by Engineer-in-Charge. Make :- HPL / Havells / KEI / Plaza
M&L for repair/replacement submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2x6 Sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit / casing & capping and making good the disturbed wall surfaces to match with existing specifications, complete all as specified and directed by Engineer-in-Charge. Make :- HPL / Havells / KEI / Plaza
M&L repair/replacement for submain wiring with two single core FRLS PVC insulated flexible copper conductor cable of size 2x10 Sqmm and one single core PVC insulated flexible copper conductor cable green colour of size 6.0 Sqmm as earth lead in and including PVC conduit / casing & capping and making good the disturbed wall surfaces to match with existing specifications, complete all as specified and directed by Engineer-in-Charge. Make :- HPL / Havells / KEI / Plaza
S&F MCB TP 63 Amps, 415 Volts, 50 Hz AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 25 KA breaking capacity, complete all as specified and directed. Make :- C&S Cat Part No. CSMBS3C63 or technocommercially equivalent make of L&T / HPL / ABB
S&F MCB TP 32 Amps, 415 Volts, 50 Hz AC, made from moulded self-extinguishing thermostate plastic and suitable for ‘C’ curve, 25 KA breaking capacity, complete all as specified and directed. Make :- C&S Cat Part No. CSMBS3C32 or technocommercially equivalent make of L&T / HPL / ABB
M/S ZENITH TRADE LINK
M/S ASHRAF CONSTRUCTIONS
M/S M.A.S ELECTRICALS
M/S Khan Hussain & Co.
ABDUL MAJID BHAT
M/S Mohammad Saleem and Co
ORISON ENTERPRISES
M/S Vivek Gupta and Co
M/S REDLY ENGINEERS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .