Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 CrAdmitted-Finance | ₹1.7 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.3 Cr+₹61.7 L (37.0%)Admitted-Finance | ₹2.3 Cr+₹61.7 L (37.0%) | L2 | Admitted-Finance |
| 3 | L3₹2.3 Cr+₹63.1 L (37.8%)Admitted-Finance 248 1 CHHEDIPURWA STATION ROAD BEHIND GURU NANAK SCHOOL GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | ₹2.3 Cr+₹63.1 L (37.8%) | L3 | Admitted-Finance |
| 4 | Rejected-Technical | - | - | Rejected-Technical document are not as per requirement |
| Sl No | Description | Qty | Unit | NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER L2 | M/S SURYA ELECTRICALS L1 | M/S SMM INFRATECH PVT Ltd L3 |
|---|---|---|---|---|---|---|
| 1.00Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store. | ||||||
| 2.00 | 11 KV RMU | 1 | Nos | 7,100 ₹7,100 Lowest | 25,000 ₹25,000 | 10,000 ₹10,000 |
| 3.00 | 33/11 KV Transformer 10 MVA | 1 | Nos | 1,00,000 ₹1,00,000 | 50,000 ₹50,000 Lowest | 1,50,000 ₹1,50,000 |
| 4.00 | 33/11 KV Transformer 5 MVA | 1 | Nos | 1,00,000 ₹1,00,000 | 50,000 ₹50,000 Lowest | 1,25,000 ₹1,25,000 |
| 5.00 | TF Control Pannel for 5 MVA T/F | 1 | Nos | 6,000 ₹6,000 Lowest | 8,000 ₹8,000 | 10,000 ₹10,000 |
| 6.00 | 33 KV VCB 800 Amp. | 2 | Nos | 6,000 ₹12,000 Lowest | 8,000 ₹16,000 | 10,000 ₹20,000 |
| 7.00 | 33 KV Control Panle Single Circuit T/F | 1 | Nos | 6,000 ₹6,000 Lowest | 8,000 ₹8,000 | 10,000 ₹10,000 |
| 8.00 | 33 KV Lightening Arester 400 Amp. | 6 | Nos | 6,000 ₹36,000 | 1,000 ₹6,000 Lowest | 5,000 ₹30,000 |
| 9.00 | 33 KV Bus Isolator | 2 | Nos | 6,000 ₹12,000 | 5,000 ₹10,000 Lowest | 5,600 ₹11,200 |
| 10.00 | 33 KV Line Isolator | 1 | Nos | 6,000 ₹6,000 | 5,000 ₹5,000 Lowest | 5,600 ₹5,600 |
Tender Value
₹2.9 Cr
EMD Value
₹2.9 L
Closing Date
28 Feb 2023, 12:00 pmClosed
SE,EDC-IV,LESA-CISS GOMTI,MVVNL
4/82-83, INDERLOK HYDEL COLONY, KRISHNANAGAR, LUCKNOW
Construction of Line and Sub station and other related work at New Nagar Nikaye Area against Deposit Scheme under jurisdiction of EDD, CESS-III, Cis Gomti Lesa, Lucknow
2023_MVVNL_777361_2
92/EDC-IV/LESA/2022-23
Open Tender
Miscellaneous Works
Fixed-rate
90 days
LUCKNOW
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
A/C-1444100402,IFSC Code-CBIN0280139
₹2.9 L
23 Mar 2023
24 Feb 2023
28 Feb 2023
24 Feb 2023
28 Feb 2023
24 Feb 2023
Amount
Safe Loading, Carriage & unloading of following Materials from Centre Store to Pit Site/J.E. Dump Store.
11 KV RMU
33/11 KV Transformer 10 MVA
33/11 KV Transformer 5 MVA
TF Control Pannel for 5 MVA T/F
33 KV VCB 800 Amp.
33 KV Control Panle Single Circuit T/F
33 KV Lightening Arester 400 Amp.
33 KV Bus Isolator
33 KV Line Isolator
33 KV CT 400/200/1-1-1A
33 KV CT 200/100/5A
11 KV VCB Busbar Coupler
Battery and Battery Charger Complete
Copper Control cable 2x2.5 sq.mm.
Copper Control cable 4x2.5 sq.mm.
Copper Control cable 6x2.5 sq.mm.
ASCR Panther Conductor for bus bar
11 KV 3x300 mm XLPE Cable
11 KV Outdoor 3x300 sq.mm.
11 KV Indoor 3x300 sq.mm.
ST Pole 11 Mtr. Long
PCC Pole 8.5 Mtr. Long
ACSR DOG Conductor
ACSR RACCON/Wesal Conductor
ABC 3x50/3x95/3x120
LT XLPE Cable 3.5x70 sq.mm.
11 KV XLPE Cable 3x185 sq.mm.
11 KV Outdoor 3x185 sq.mm.
11 KV Indoor 3x185 sq.mm.
11 KV ST 3x185 sq.mm.
11 KV VCB OG 200/100/5A 350 MVA
11 KV VCB IC 600/300/5A
11 KV V type Xarm
GI Wire 08/10 SWG
Disk Fitting
Disk Insulator with pin
Stay Set complete
Stay wire 7/10 SWG
Earth Wire
11 KV Pin Insulator with pin
TF 250 Kva
TF 100 KVA
TF 63 Kva
TF 25 KVA
PVC Cable LT 1x400/1x240/1x630/3.5x70/3.5x240 mm2
Dragging of ST/PCC Pole digging of pit erection of sub-station type double pole structure on ST/PCC Pole with fixing of necessary item such as Top Channel, along with grouting (As per RESPO Norms) Dropper Channel, 11 pin insulator with Pin & 11 KV Disc Insulator with fitting, DO Fuse set its ramming, as per RESPO Specification. Only Pole and insulator will be Provided by the Department.
Fabrication, erection of double pole for end terminations/sectional double pole, 11 KV line on ST/PCC Pole with fixing of necessary clamps & other accessories like 1 nos top channel 100x50 mm 2.24 m. 1 No. Guarding Angle. Its grouting in ratio 1:4:8 plinthing 300 mm above ground level, earthing of support & one side cable expose.
Dragging of ST/PCC Pole to pit site, diging of pit erection and grouting (As per RESPO Norms) of 11 KV line with fixing of necessary item, such as V-type X-arm, F-bracket, 11 KV Pin insulator, Gaurding angle (1.8 mm 65x65x6) with Nut & bolts its ramming as per RESSPO Specification. Only Pole and insulator will be Provided by the Department.
Dragging of ST/PCC Pole from Dump Store to pit site, diging of pit erection and grouting (As per RESPO Norms) of LT support suitable for laying of ABC Line on 8.5 Mtr Long PCC Pole by providing of necessary eye hook/Lt Shackle insulator with Clamps and its accessories etc. as per RESSPO Specification. Only Pole will be Provided by the Department.
Grouting & Nuzzling of 11 KV stay set complete including fixing of necessary clamps. Accessories required including its grouting by civil material (Sand, Brick blast & cement). All material except stay wire shall be supplied by the contractor.
Ordinary earthing by 11 KV MS earth Rod 2500mm long as per RESPO Schedule. All material except earthing wire shall be supplied by the contractor.
Laying Stringing & sagging of 3 Phase 3 wire 11 KV New Line on DOG conductor as per RESPO Specification and direction on E/I. All material exept DOG conductor shall be supplied by the contractor.
Laying Stringing & sagging of 3 Phase 3 wire 11 KV New Line on ACSR Wesal/Racoon conductor as per RESPO Specification and direction on E/I. All material exept ACSR wesal/Racoon conductor shall be supplied by the contractor.
Guarding of HT line by GI wire. GI wire shall be supplied by the department.
Proper laying & commissioning of (3x50/3x95/3x120 sq.mm) XLPE Aerial Bunched Conductor. Only ABC Provided by deptt.
Fixing of Single/Three Phase distribution boxes/Kiosk on the LT poles including all clamps and material required for mounting connections & sealing. Only distribution box Shall be supplied by deptt.
Digging of pit suitable for 3x70 sq.mm LT XLPE cable 3x70 sq.mm. laying. After LT XLPE cable laying refilling by Bricks & sand as Per RESPO Norms. Only LT XLPE cable supplied by Department.
Digging of pit suitable for 3x300 sq.mm 11 KV XLPE cable laying. After 11 KV XLPE cable laying refilling by Bricks & sand as Per RESPO Norms. Only 11 KV XLPE cable supplied by Department.
Digging of pit suitable for 3x185 sq.mm 11 KV XLPE cable laying. After 11 KV XLPE cable laying refilling by Bricks & sand as Per RESPO Norms. Only 11 KV XLPE cable supplied by Department.
Laying of 3x185 sq.mm 11 KV XLPE cable by drill method as per RESPO Norms. Only 11 KV XLPE cable supplied by Department.
For Railway/river/cannel/Road/drain crossing in Hume pipe 200 dia by drilling single circuit 3x185 sq.mm. XLPE Cable ( All the material required for laying will be supplied by the contractor except 11 KV XLPE cable)
Laying of single 11 KV 3x185 Sqmm XLPE Cable by drill method in HDPE Pipe 125 mm dia (All material will be provided by contractor except 11 KV cable).
Cable Hosting of 11 KV 3x185/3x300/3x185 sq. mm XLPE Cable at the following including jumpering etc complete with help of GI Pipe as Per RESPO Norms. GI pipe and other required material shall be supplied by contractor.
High pressure testing of 11 KV 3x185/3x300/3x185 XLPE cable along with arrangement of High Pressure equipment.
Well type earthing of with 60 Fit Deep borring and providing GI Pipe 1.5" dia ("B" Class) and earthing must be joint by G.I. Strip of 32x5 mm thick long attached with nut & bolts and GI pipe cap. All material and labour shall be supplied the contractor.
Construction of T/F plinth of size 2x2x1.2 mtr with the help first class brick & masonary in the ratio 1:4 cement & sand coarse. Filling the structure completely per norms with RCC to 1:2:2 cement & stone grit with MS bar and MS channel for resting transformer.
Wiremess fencing of 11/0.4 KV S/S shall be made of rectangular of size as per site requirement not exceeding 3 meter fabrication 45x45x5 mm angel the frame is also have 1 no. Horizontal runner of MS flat 40x5 welded in middle to support of wire mesh. Rectangular welded type wire mess of size 50x25 made of 12 S.W.G. wire mess shall be welded all along the periphery of the frame as well as on horizontal runner to give extra strength of welding to wire mess welded on the frame. Diagonal bracing of all the frame panel will be welded with Ms flat of size 25x3mm to support as per RESPO specification & direction of E/I.
Construction of masonry/metalic type distribution pillar of size 1x1.5x2.5 mtr. with supply & fixing of fabricated 4 nos. doors (2ft.x4ft.) made of BP sheet of 18 SWG with locking arrangement, 2 Nos. Straight MS angle 50x50x6mm (1800 mm olng) 2 nos. 500 Amp, 3 Nos. 300 Amp henely Type Tailess Funse Unit, 3 Nos coper bus bar of size 1000x50x6 mm and one No. Alum busbar 1000x50x6 mm including all civil material required for work. All material shall be supplied by contractor.
Fabrication, errection & commissioning of 250 KVA T/F on Plinth with all accessories. All material except 250 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 100 KVA T/F on Double Pole with all accessories. All material except 100 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 63 KVA T/F on Double Pole with all accessories. All material except 63 KVA T/F shall be supplied by the Contractor.
Fabrication, errection & commissioning of 25 KVA T/F on Double Pole with all accessories. All material except 25 KVA T/F shall be supplied by the Contractor.
Eearthing of RMU pipe type with 60 Fit Deep boring and providing GI Pipe 1.5" dia (60 fit GI pipes) and earthing must be joint by G.I. Strip of 25x5x6 mm thick long attached with nut bolts, clamp, L-piece and GI pipe cap. All material and labour shall be supplied the contractor.
Construction of RMU plinth of size 1.5x1x1 mtr with the help first class brick, sand & cement including plastering and other work required for complication of work in all aspect. All Material shall be supplied by contractor.
Dismantling of 100/160 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Dismantling of 63 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Dismantling of 25 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Dismantling of 10/16 KVA T/F opening jumbers, LT cable and Other accessories of T/F including Safe loading, unloading Carriage from site to JE dump Store/Center Store.
Making of Heat & shrinkables joints of following sizes and types in 11 KV XLPE cable(Jointing kit will be provided by deptt.)
(i) Outdoor/Indoor end termination kit for 11 KV 3x185 sqmm XLPE cable
(i) S/TH end termination kit for 11 KV 3x300 sqmm XLPE cable
Fixing and laying of LT PVC Cable 1x400/1x240//1x400/1x630 sq.mm as per RESPO Norms
Lopping & Chopping of tree branches for clearance of HT/LT line. After clearance of line through out pieces of tree branches of site.
Dismantling of LT/HT line and other electric accessories including rolling back its conductor, wire, including stacking & transpiration of these materials form site to JE dump store/Central Store Daliganj, Lucknow.
Shifting of Store Material i.e. Rail /Joist etc with d help of crane at suitable place in store distance 100 mtr approx and again shifting at same place after completion of work.
Welding of riser strip with earth mat and structure body (One set means one riser strip welding to main equipments).
PLINTH OF 10 and 5 MVA.33/11 KV T/F Construction of plinth of size 4x4 Mtr. for 10 an 5 MVA T/F having 0.4 Mtr. above ground level . The work including excavation of foundation base concreting in CC 1:6:12 ratio (cement ,fine sand & brick ballast)first class brick work in cement morter of ratio 1:4 foundation CC in 1:4:8 ratio (cement ,fine sand & brick blast) and RCC working ratio 1:2:4 (cement ,coarse sand and stone grit of 20mm gauge using MS Bars of 10mm dia( tor ) in reinforcement including its cutting ,bending &binding in required shape .The work also includes laying of 2 No. 4.0 Mts. long each rail pieces complete with cutting & proper fitting etc. The plinth will be made as per drawing and shall be plastered/ finished on top and sides of the plinth .
FABRICATION ,ERECTION & GROUTING OF S/S STRUCTURE.
ISOLATOR STRUCTURE:- Fabrication of isolator structures 3.5 Mtr. In height as per drawing No. RES 39.Digging of two Nos. pits of size 1.075x0.9x0.3 Mtr. providing stone pad at the bottom of the pit and grouting pad at the bottom of the pit and grouting of two legs of the isolator structure in CC (cement coarse sand and stone grit of 20m.m gauge)of the ratio 1:4:8 in block of 1.075Mtrx0.3 mm including supply of all T&P complete in all respect. Both plinths of the isolator structure shall be properly finished with smoothening of edges.
LIGHTENING ARRESTOR /C.T.STRUCTURE:- Fabrication of lightening arrestor/CT structure/.as per drawing No. Res-39 Digging of two Nos. pits of size 1.075x0.3x0.3Mtr providing stone pad at the bottom of the pit and grouting of two legs of the above structures in CC (Cement, coarse sand and stone grit of 20mm gauge ) of ratio 1:4:8 in block of 1.075Mtr X0.3Mtr including supply of all civil material complete in all respect. Both plinths of the structures shall be properly finished with champering of edges etc.
PLINTH FOR VCB
Construction of plinth of size 2.0 mtr x 1.5 mtr x 0.9 mtr suitable for erection of upper structure for 33KV VCB including grouting of anchor bolts in proper alignment and level. Scope of work includes excavation of foundation base concreting in CC 1:6:12(cement, fine sand & brick ballast ),1st class brick work in cement mortar of ratio 1:4 CC in ratio 1:4:8 and RCC work in ratio 1:2:4(cement coarse sand and stone grit of 20mm gauge )as per drawing.
ERRECTION & INSTALLATION OF 33/11KV,10 and 5 MVA TRANSFORMERS :-
Erection and installation of 33/11kV,5 MVA transformer in a levelledposition on the plinth. The work include shifting of transformer to the site of installation within the substation premises, assembling fixing and fitting of all accessories and filling of transformer oil to the desired level and insuring that there is no leakage. All the jumpering & connection are included in the scope of work.
Earthing by way of boring and lowering of "B" class GI pipe 50mm dia from ground upto the water level (minimum 40 meter deep) as per standard practice
Fabrication and grouting of M.S Angle 75X75X6 mm in L shape & in proper size and alignment to provide support for the two separate earthing strips for power transformer neutral including supply and fixing of two nos. Flexible copper bonds for neutral earthing.
Fabrication and erection of cable support made of two pieces of M.S channel 100x50mm,3.0 Mtr.long joined to each other by means of 5 Nos. M.S Flat 50x6mm pieces of size 150mm long each by welding at equal intervals as per drawing and grouting in a block of size300x300x700mm complete with one coat of ready mixed primer and two coats of aluminium paint. This includes providing of four nose M.S clamp made of M.S flat holding the cable including nuts and bolts and fixing of XLPE Cable.
INSTALLATION OF ISOLATORS
Assembling and installation of line /bus isolator on the isolator structure adjusting of opening mechanism in proper alignment so as to ensure smooth operation of the same in case of line isolator proper operation of earth links shall also be insured. The work includes fabrication for proper flexing if required.
INSTALLATION OF LIGHTENING ARRESTORS
Assembling and installation Mounting of 3Nos (1 set) lightening arrestors on the L.A. Structure/ complete with making earth connections(separate)and line connections the work includes fabrication for proper fixing earthing of LA with G.I. Strip.
INSTALLATION OF CT
Installation of 3 Nos.(1 set) CTs on the CTs structure . Along with C.T. J/B. The work includes fabrication for proper fixing if required.
INSTALLATION OF VCB Installation of 33 KV IC and OG VCB complete work including commissioning.
INSTALLATION OF VCB Installation of 11 KV IC and OG VCB complete work including commissioning.
INSTALLATION OF SWITCHGEARS IN CONTROLROOM
Shifting carefully & safely 11KV I/C & O/G switchgear from outside of the switchgear room, as per direction of Engineer incharge, placing and fixing of switchgear on foundation providing G.I, Nuts & Bolts of proper size in proper position and alignment and checking, complete work with Mounting of P.T on incoming S/G.
Fixing and making bus bar connections in between all switch gearsafter cleaning and tapping with H.T.Tape,empire tape and PVC tape properly, providing and fixing of 6 mm thick Bakelite separators and plugging of all opening & holes with plastic compound complete work including cost of all material (except copper Bus Bars)strictly to the satisfaction of site in- charge.
Shifting carefully, installation & commissioning of 33KV single circuit transformer control panel in control room including grouting of above.
Jumpering of all new installed equipment with bus bar with ACSR panther conductor including supply of PG clamp & connector etc.
Construction of cable trench of size 300x300 mm including brick work 1:4 in wall of the trench brick ballast work in 1:5:10 on foundation plaster 12 mm thick with coarse sand 1:4 and surface finishing with cement : providing MS strip at an interval of 0.5 M & MS angle running on both the edges of trench (M.S.Strip Shall be provided by the contractor).
Construction of welded frame type control cable trench cover 0.5 M long suitable for trench (SI. No. 28)including cost of M.S.Steel /Torr Bar.(M.S.Steel /Torr Bar.Shall be provided by the contractor).
Laying & Fixing of following size copper. control cable through underground/cable trench/trench in SGR interlinking through proper connections/transformer control panel/protection board /Battery and Battery Charger/Buchhjoltz Relay 33/11 KV Transformer junction box/ 33KV VCB ,CTs etc as per site conditions.
Supply and fixing of cable tray 75 mm wide
Painting of new structure
Supply and fixing of fir bucket st (One Set Contains one no stand and four no. Bucket as per RESPO Norms.
Construction of main bus bar ganrty with foudnation as per RESPO Norms.
Supply and fixing of Barbed wire with fencing as per RESPO Norms.
Supply and fixing of L Piece for 250 and 100 KV TF as per RESPO Norms.
Supply and fixing of Allu. Lug 240 sq.mm. as per RESPO Norms.
Supply and fixing of TPMO as per RESPO Norms.
Supply and fixing of 11 KV Fuse Set as per RESPO Norms.
Fixing of Battery and Battery charger Complete as per RESPO Norms.
GST Extra as per Rules
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
M/S SMM INFRATECH PVT Ltd
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .