Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | FIRST₹9.8 LAccepted-AOC | FIRST | Accepted-AOC BEING LOWEST | |
| 2 | SECOND₹10.8 LRejected-Finance SITE NO 29 30 1ST CROSS NAGAPPA REDDY LAYOUT KAGGADASAPURA CV RAMAN NAGAR PO BANGALORE 560 093 | BANGALORE | BANGALORE | KARNATAKA | 560093 | SECOND | Rejected-Finance BEING NOT LOWEST | |
| 3 | THIRD₹10.9 LRejected-Finance NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | THIRD | Rejected-Finance BEING NOT LOWEST | |
| 4 | FORTH₹11.1 LRejected-Finance 39 SR LAYOUT MAIN ROAD NAL WING TUNNEL ROAD MURUGESH PALYA BANGALORE 560 017 | BENGALURU URBAN | KARNATAKA | 560017 | FORTH | Rejected-Finance BEING NOT LOWEST | |
| 5 | FIFTH₹11.6 LRejected-Finance | FIFTH | Rejected-Finance BEING NOT LOWEST |
Tender Value
₹11.9 L
EMD Value
₹23,800
Closing Date
23 Dec 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) MARATHAHALLI
GE AF MARATHAHALLI WIND TUNNEL ROAD, KEMPAPURA, YEMALUR POST, BANGALORE. PIN- 560037
REPAIR AND MAINTENANCE TO BATTERY CHARGERS FREQUENCY CONVERTER RECTIFIER AND ALLIED WORKS AT VARIOUS LOCATION UNDER GE AF MARATHAHALLI BANGALORE
2021_MES_490919_1
8921/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) MARATHAHALLI
ALL AS PER ENIT
7 documents required · 7 mandatory
₹500
GE (AF) MARATHAHALLI
₹23,800
Yes
5 Mar 2022
27 Nov 2021
27 Dec 2021
27 Nov 2021
23 Dec 2021
16 Dec 2021
60 days
Amount
All as per item No 1 above but Battery charger12v/15 Amps qty. -01 Nos at BCR room ASTE complete all as specified and as directed.
All as per item No 1 above but Battery charger12v/30 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
All as per item No 1 above but Battery charger12v/60 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
All as per item No 1 above but Battery charger 24 V/60 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
All as per item No 1 above but Battery charger 30V/50 Amps qty. -03 Nos at BCR room ASTE complete all as specified and as directed.
Repair/Maint of frequency converter 20 KVA capacity ,3 phase & neutral , phase to phase voltage 415 v ,50 Hz and out put voltage 200v, 400 Hz and replace the u/sminor parts.complete checking transformers , circuits , internal wiring PCB boards, in put and out put voltages and frequency. QTY- 02 Nos. NOTE :(i) major parts will be measered and paid separately. (ii) Maintainance will be carried out once in three months .
All as per item No 7 above but Frequency converter 10 KVA capacity ,3 phase & neutral , phase to phase voltage 415 v ,50 Hz and out put voltage 200v, 400 Hz, qty. -02 Nos
Repair/Maint of wave rectifier 4 KW capacity and replace the u/sminor parts.complete checking transformers , circuits , internal wiring PCB boards, in put and out put voltages and frequency. QTY- 02 Nos complete all as specified and as directed. NOTE :(i) Major parts will be measered and paid separately. (ii) Maintainance will be carried out once in three months .
All as per item No 9 above but Wave rectifier 2KWcapacity, qty. -02 Nos complete all as specified and as directed.
All as per item No 9 above but Wave rectifier 1KWcapacity, qty. -02 Nos complete all as specified and as directed.
Repair/Maint of heat converter 2 KW capacity and replace the u/sminor parts.complete checking transformers , circuits , internal wiring PCB boards, in put and out put voltages and frequency. QTY- 07Nos complete all as specified and as directed. NOTE :(i) major parts will be measered and paid separately. (ii) Maintainance will be carried out once in three months .
Testing checking and calibration of battery charger unit including replacement of PCB and transformer complete with carrying the workshop after disconnetion and refixing the same after back to the workshop all as specified and directed . ( Note :- spares will be measured and paid separately)
M & L for sub main wiring complete with two runs of 10 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 6 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
M & L for sub main wiring complete with two runs of 4 Sqmm single core FRLS grade PVC insulated unsheathed cable 1100Volt grade multistranded copper conductor drawn through and including PVC conduit and accessories surface on wall, roofs etc with one run of PVC insulated solid copper conductor 2.5 Sqmm single core as earth continuity conductor connected with earth dolly and mains complete all as specified and directed.
Supply and replace PCB Board M12R-1 complete all as specified and as directed.
supply and replacement of Motor for fequency converter complete all as specified and as directed.
Supply and replace Mosfet IRFP-460 complete all as specified and as directed.
Supply and replace Mosfet FEP 30 DP complete all as specified and as directed.
Supply and replace PCB Card Charger Bank component complete all as specified and as directed.
Supply and replace Arvi 112 PS VO PCB component complete all as specified and as directed.
Supply and replace Arvi 139 Card component chargers for PCB card complete all as specified and as directed.
Supply and replace Senseing Transformer complete all as specified and as directed.
Supply and replace Fan 4inch AC complete all as specified and as directed.
Supply and replace PCB card complete all as specified and as directed.
S & F MCB SPN 40 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB SP 6-32 Amps, 'C' series, 240 V complete incl making conections all as specified and directed.
S & F MCB TPN 63 Amps incl making connections acomplete all as specified and as directed.
S&F in replacement single pole and neutral enclosure with two pin and earth plug and socket including 1 No. Double pole MCB 20 Amp capacity complete all as specified and as directed
S&F in replacement Triple pole and neutral enclosure with Three pin and earth plug and socket including 1 No. Triple pole MCB 32 Amp capacity complete all as specified and as directed
S&F in replacement Triple pole and neutral enclosure with Three pin and earth plug and socket including 1 No. Triple pole MCB 63 Amp capacity complete all as specified and as directed
Supply and fix in replacement MCCB TPN 415 Volts 160 Amps,beaking capacity 25 kA complete with making all connections as specified and directed.
Supply and fix in replacement MCCB TPN 415 Volts 100 Amps, beaking capacity 25 kA complete with making all connections as specified and directed.
All as per ser item no.34 here-in-before but MCCB TPN 415 Volts 63 Amps, beaking capacity 25 kA complete with making all connections as specified and directed.
All as per ser item no.34 here-in-before but MCCB TPN 415 Volts 32Amps, beaking capacity 25 kA complete with making all connections as specified and directed.
S & F MCB DB TPN 4Way, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
S & F MCCB DB Vertical TPN 8 Way 'A' Frame,Including MCCB TPN 125 Amp Beaking capacity 25Ka -01 nos, Double Door flush to wall including all cutting etc on wall including making good the disturbed surfaces to match the existing in replacement of old U/s complete all as specified and directed.
Cross linked poly-ethylene (XLPE) insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables ( heavy duty) with aluminium conductor, 1100 volts LT grade of cross-sectional area 50 Sqmm 3.5 core laid in trenches/through pipe in road crossings/ paths /drains /ducts /floors /along poles/walls/ceilings/ equipments etc supplied, fixed/ laid in repair including commissioning and testing complete all as specified and as directed .
Material & labour for fixing of Earth continuity conductor Copper strip of size 20 X 3.15 mm with brazing at joints , fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles,equipments or any other indicated situation for loop earthing etc, copper strip fixed on with epoxy insulatorof suitable size all as specified and directed by Engineer-in-Charge.
M & L for Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to galvanized iron strip 32 x 6mm dia as earthing lead by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in electrical plate No. 5 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15 cm c/c both way for cover and MS frame etc., complete all as specified.
Material and labour for earthing complete with Copper earth plate electrode 600 X 600 X 3. 15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to copper earth strip 20 x 3 mm thick by means of with brazing at joints and connecting to testing point including provision of test point, test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed . Notes:- (i) copper strip beyond 7.5 M shall be measured and paid separately under relevant items of this schedule.
B5BUILDING SOLUTIONS
devan enterprises
GKR and CO
Harish Constructions
M/S Suresh Raju
UNIVERSAL ENGINEERING
Lucky Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .