Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.8 LAccepted-AOC | L1 | Accepted-AOC Lowest bid value | |
| 2 | L2₹32.9 L+₹2.6 L (8.74%)Rejected-AOC | L2 | Rejected-AOC Higher bid value | |
| 3 | L3₹33.7 L+₹3.5 L (11.5%)Rejected-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | L3 | Rejected-AOC Higher bid value |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
6 Aug 2022, 6:00 pmClosed
GE (AF) BANGALORE
GE (AF) BANGALORE, HQ TC AIR FORCE , BANGALORE 560006
CLEANING OF RCC, PVC SERVICE TANKS AND CONNECTED WORKS, REPAIRS MAINT OF SECURITY STREET LIGHT FITTINGS AND SOLAR LIGHTS, REPLACEMENT OF CONVETIONAL FITTINGS TO LED FITTING AND CONNECTED WORKS AND CLEANING OF OHT, SEMI UG SUMPS, RCC PVC SERVICE TANKS
2022_MES_537394_1
8903/GE/47
Open Tender
Civil Works
Works
270 days
GE (AF) BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GE (AF) BANGALORE
₹70,000
Yes
19 Sept 2022
12 Jul 2022
8 Aug 2022
12 Jul 2022
6 Aug 2022
25 Jul 2022
13 Jul 2022 - 19 Jul 2022
Amount
Taking down existing defective LED street/security/flood/post top light fittings of any description and type from pole/ walls of buildings of any height complete, after disconnecting the electrical connections and re-fixing the same in position after replacement of defective parts and accessories including connecting up and testing for satisfactory functioning complete all as specified and directed. Note: (i) Replacement of spares and connected items shall be measured and paid as supply only under relevant item of schedule. (ii) Replacement of unserviceable spare parts/ accessories of the light fittings and replacement of brackets required for defective light fittings shall be measured and paid separately at supply only rates under relevant items of this schedule. (iii) Replacement of screws, nuts, bolts and consumables shall be deemed to be included in the rate quoted and no extra payment shall be allowed. (iv) Contractor or his representative will attend unserviceable street light/faulty complaints and ensure completion of fault at the earliest and copy of the report to be submitted to the Engineer-in-Charge. (v) All tools and plants,ladder required shall be brought by the contractor to the site and rate quoted shall deem to include for the same also.
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 18/36 Watts LED luminaires, 230 Volts. Make : Crompton /Bajaj/Philips/Havells/Wipro
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 40/45/50/60 Watts LED luminaires, 230 Volts. Make : Crompton /Bajaj/Philips/Havells/Wipro
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 75/80/90 Watts LED luminaires, 230 Volts. Make : Crompton /Bajaj/Philips/Havells/Wipro
Supply only high energy efficent constant current electronic driver suitable for 220v,50hz, LED street light fitting 100/120 Watts LED luminaires, 230 Volts. Make : Crompton /Bajaj/Philips/Havells/Wipro
M & L in repairs of sub main wiring from street light to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 1.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc including 1.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
M & L in repairs of sub main wiring from street light to junction box with two single core PVC insulated cable with copper conductor multistranded 1100 volts grade 2.5 sqmm in and including heavy grade PVC conduit and its accessories with fixing arrangements on pole surface, wall, ceiling etc including 2.5 sqmm PVC insulated multistranded copper earth continuity conductor and connecting to main earth dolly complete all as specified and directed. Note : One run of earth continuity conductor,one run of PVC conduit and two run of copper conductor together taken as one length for measuring unit length.
S & F in repairs of service wire 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm x 2 Core nominal cross section complete all as specified.
M & L for in repairs of LT UG cable 16 Sqmm x 4 Core 1100 Volts grade XLPE insulated, steel tape armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including connecting, testing complete all as specified and as directed.
M & L for in repairs of LT UG cable 25 Sqmm x 4 Core 1100 Volts grade XLPE insulated , steel tape armored, heavy duty with aluminium conductor laid in trenches or fixed to walls/ poles or passing through pipes with and including, lugs/ thimbles/ ferrules including connecting, testing complete all as specified and as directed.
Supply erecting and fixing in repairs of Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 and marking ZEBRA pattern with alternate yellow and black colour to steel tubular poles 1.5m from the bottom of pole and one coat of aluminium painting for the remaining portion of pole including numbering of poles complete all as specified and directed Note ( Item no 9,10,11) Excavation earth work and sand cushioning, brick protection, pole foundation , coping, plinth protection etc. Shall be measured and paid separately under relevant item of schedule
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, poles struts, laying of cables/pipes, etc., not exceeding 10 Sqm on plan and not exceeding 1.5m in depth and getting out in soft/loose soil complete all as specified and directed.
All as per above item No 12 herein before but but above 1.5 mtr depth in soft/loose soil
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm as in soils complete all as specified and as directed.
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 mtr above the starting point as in soils complete all as specified and as directed.
Supply & spread dry river sand in in trenches for cable protection all as specied and as directed
Supply and Lay burnt bricks of sub class "B" in trenches for cable protection
Material ans labour for PCC 1:3:6 type C-2 using 40 mm graded aggregate for foundations of poles/stays complete including form work all as directed.
Material and labour for PCC 1:2:4 type B-1 using 20 mm graded aggregate for coping of poles and platform incl. necessary form work fair and finishing without using extra cement complete all as directed.
M&L in repairs of Boring of holes under road pavement hard standing by manual boring incl making good the disturbed surfaces complete all as specified and directed
Supply and lay in repairs GI Pipe Ilight grade 50 mm dia for cable protection laid in trenches or fixed on pole/wall complete all as specified and as directed.
Supply and fix PVC conduit pipe 25mm dia heavy duty secured to poleswith necessary clamps and fitting such as bolts, nuts fixed in repairs all as specied and as directed
S & fix in repairs GI pipe 40/50 mm bore, light grade, 1.50 metres long, bent to shape required as in street light brackets, fixed to poles/ walls with suitable size MS clamps, nuts & bolts complete, all as specified and as directed.
M & L for painting of steel tubular poles with one coat of aluminium paint and also marking ZEBRA pattern with alternate yellow and black colour to steel tubular poles 1.5m from the bottom of pole including numbering of poles using synthetic enamel paint complete all as specified and directed
M & L for painting of RCC poles with one coat of white cement based paint and also marking ZEBRA pattern with alternate yellow and black colour to steel tubular poles 1.5m from the bottom of pole including numbering of poles using synthetic enamel paint, complete all as specified and directed
Supply and fix PVC cable loop box, size not less than 200 mm x 140 mm x 95 mm, out door type, duly fitted on bottom of RCC/ steel poles with suitable clamp, nuts, bolts & washers complete to accommodate and including one No of 6 Amps single pole MCB, & suitable alumiium busbar of 3 phase porcelain insulated connectors for incoming and outgoing connections fixed in repairs all as specified and directed. Make Sintex or equivalent
Supply and fix in repairs of sheet metal enclosure street light timer control board 3Φ 415V , 50Hz IP >54 having digital programmable (24 Hrs) timer switch, contactor assembly 415V 4 pole, 65 Amps with auxiliary contact, MCB TPN 415V, 63 Apms capacity as incommer, with manual/auto bypass arrangement, connector terminals & status indicators including testing complete all as specified and directed. Make : Indoasian/havells/Legrand/HPL
Supply and fix in repairs of modular contactor with auto/manual override option 4P, 415V , 50Hz , 63A , suitable for existing timer control board complete all as specified and directed Make : Havells Cat No :DHPMC063340M or Equivalent in L&T/Siemens/Indoasian
Supply and fix in repairs of modular contactor with auto/manual override option 2P, 230V , 50Hz , 63A , suitable for existing timer control board complete all as specified and directed Make : Havells Cat No :DHPMF063220M or Equivalent in L&T/Siemens/Indoasian
Supply and fix in repairs of MCB TPN, 415V , 50Hz , 63A, 10kA, 'C' type suitable for existing timer control board complete all as specified and directed
Supply and fix in repairs of MCB SPN, 220V , 50Hz ,10kA, 'C' type, 5-32A suitable for existing timer control board complete all as specified and directed
Supply and fix in repairs of MCB SP, 220V , 50Hz ,10kA, 'C' type, 5-32A for street light complete all as specified and directed
Supply and fix in repairs of Digital Multi function time switch with programmable fuction to ON/OFF the Time switch to Control a Street Lights including connecting up and testing complete all as specified and directed Make : Havells Cat No : DHTLB1016 or Eqivalent in L & T /HPL /Indoasian
M & L for reparing/serviceing solar street light including cleaning of solar panels, checking & cleaning battery and all connection terminals ,distille water topup , solar battery charging controller , LED driver complete all as specified and directed
S & F in repairs of solar street light lead acid battery 12v 75Ah complete all as specified and directed Make : Exide/Amaron/Sonic
S & Fix in repairs of MPPT Solar PWM Controller suitable for battery sizes 12/24/36/48V 40/60A including connection and testing complete all as specified and directed by engineer in charge. MAKE : ASHA POWER (NEON 60 ) or Equivalent as per Site requirement .
S & Fix in repairs of Monocrystalline Solar Photo voltaic 12V , 180 W panel suitable for Solar street light including fixing on existing mounting brackets with appropriate angle 45˚ to 60˚ to attain maximom efficency including connecting and testing complete all as specified and directed
S & Fix in repairs of Solar Panel DC MC4 connector including ternination with suitable lugs complete all as specified and directed bt engineer in charge
S & F in repairs of post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete Make : Philips/Havells/Crompton/Bajaj
S & F in repairs of LED flood light 120 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make : Philips/Havells/Crompton/Havells
S & F in repairs of LED flood light 170 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp. Make : Philips/Havells/Crompton/Havells
S & F in repairs of LED Security street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Philips/Havells/Crompton/Havells
S & F in repairs of LED street light fitting 90 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Philips/Havells/Crompton/Havells
S & F in repairs of LED street light fitting 120 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. Make : Philips/Havells/Crompton/Havells
S & F in repairs of LED Bollard with robust design outdoor IP65 of cat pt No LBLTW-10-WW of Crompton or equivalent and necessary fixing arrangement complete. Make :Crompton/HavellsPhilips/
M&L De-watering, removing all mosses, algae and dirt from internal walls, floors & mouths of pipes of RCC overhead reservoir/ under ground sump by using steel wire brush and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank/ sump using synthetic enamel paint of white colour over black background with letters of size 100mm height x 100mm breadth complete all as specified and directed for the OH Reservoir of 75000 Gallons capacity with 24 metre staging all as specified and directed.
All as per SI item No 46 above but for Overhead reservoir 50,000 Gallons capacity with staging exceeding 15 metres and not exceeding 24 metres
All as per SI item No 46 above but for Overhead reservoir 15,000 Gallons capacity with 6 metres staging
All as per SI item No 46 above but for Overhead reservoir 5000 Gallons capacity with staging of 6 metres
All as per SI item No 46 above but for UG sump 2,00,000 Gallons capacity
All as per SI item No 46 above but for UG sump 1,50,000 Gallons capacity
All as per SI item No 46above but for UG sump 1,25,000 Gallons capacity
All as per SI item No 46 above but for UG sump 20,000 Gallons capacity
All as per SI item No 46 above but for UG sump 10,000 Gallons capacity
Supply and fix in repairs 50 mm bore Ball brass valves, high pressure, with polythene float and fly- nut complete for GI pipe/PPR pipe all as specified for the following sizes:-
All as per SI item No 55 above but 50 mm bore.
M&L De-watering, removing all mosses, algae and dirt from internal walls, floors & mouths of pipes of RCC overhead tanks (Service tanks) by using steel wire brush and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank using synthetic enamel paint of white colour over black background with letters of size 50mm height x 50mm breadth, complete all as specified and directed for OH service tank upto exc 250 ltr & not exceeding 500 litres capacity
All as per SI item No 57 above but for OH service tank exc 500 ltr & not exceeding 1000 litres capacity
All as per SI item No 57 above but for OH service tank exc 1000 ltr & not exceeding 2000 litres capacity
All as per SI item No 57 above but for OH service tank exceeding 2000 litres and not exceeding 5000 ltrs capacity
M&L De-watering, removing all mosses, algae and dirt from internal walls, floors & mouths of pipes of PVC overhead tanks (Service tanks) and cleaning with high pressure industrial vacuum cleaner including removing of dirty water completely using sludge pump set and disposing off the same to a safe distance and applying of anti bacterial sterilization spray to internal surfaces using Zero bacterial compound (Sodium hypochlorte) or equivalent approved chemical complete and writing the date of cleaning on outside of tank using synthetic enamel paint of white colour over black background with letters of size 50mm height x 50mm breadth, complete all as specified and directed for OH service tank upto exc 250 ltr & not exceeding 500 litres capacity
All as per SI item No 61 above but for OH service tank exc 500 ltr & not exceeding 1000 litres capacity
All as per SI item No 61 above but for OH service tank exc 1000 ltr & not exceeding 2000 litres capacity
All as per SI item No 61 above but for OH service tank exceeding 2000 litres but not exceeding 5000ltr capacity. Note for Sl item No 1 to 8:- (i) Any damage caused to tank, lid, ball valve, pipe line and connected items during cleaning shall be repaired or replaced by the contractor without any extra cost. (ii) any damage caused to fresh water line / inlet tank pipe line over the building and connected item shall be repaired or replaced accordingly. (iii) After tank cleaning register to be mantain for obtaining signature from users and submitted to Engr-in-charge before processing RAR. (iv) Cleaning of tank shall be carried out as per site requirement complete all as specified and directed.
S&F in repairs PVC lid suitable for PVC tanks of capacity 500/1000/2000 litres, fixed in repairs all as specified and as directed.
Dismantling water tanks of capacity exc 250 ltr and n.exc 500 ltr and removing to store.
Dismantling water tanks of capacity exc 500 ltr and n.exc 1000 ltr and removing to store.
S&F in repairs rotational moulded PVC water storage tank 500ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and as directed.
S&F in repairs rotational moulded PVC water storage tank 1000ltrs capacity conforming to IS-12701(1989) cylindrical vertical type double-layered with closed top including inlet,outlet and wash out holes of approved make hoisted and fixed in position all as specified in SSR Part I etc complete all as specified and as directed.
S& F in repairs of GI ELBOW threaded, 20 mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in repairs of GI TEE threaded, 20mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in repairs of GI SOCKET threaded, 20mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in repairs of GI UNION threaded, 20mm bore fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
S& F in repairs of GI PLUG threaded, 20mm bore fixed to walls and ceiling laid in floors including testing complete all as specified and directed.
S& F in repairs of GI NIPPLE threaded, 20mm bore fixed walls and ceiling to laid in floors including testing complete all as specified and directed.
S& F in repairs of GI REDUCER threaded, 25x20mm bore,ISI marked fixed to walls and ceiling or laid in floors including testing complete all as specified and directed.
Taking up or down GI tubing/PPR including all fittings from trenches , wall, floor etc including cleaning by roding for refixing or removing to store for safe custody/ reuse or disposal under schedule of credit and all as specified
25 mm bore
20 mm bore
15 mm bore
Laying or fixing only of steel tubing/PPR obtained from item Sl No 77 here-in-before including provision of heavy duty ISI marked new GI fittings (Such as socket/ elbow/ Tee/ union/ reducer/ nipple/ flange etc) to wall/flooring /ceiling etc or laid in trenches all as specified. Note : Screwing if required shall be measured and paid separately under respective item
25 mm bore
20 mm bore
15 mm bore
M&L for Cutting of existing GI pipe in position for taking down addition alteration or for repair complete all as specified and directed for the following sizes
25 mm bore
20 mm bore
15 mm bore
M&L for Screwing ( Threads making ) of existing galvanised steel tubing for addition alteration extending or reducing in length for repair all as specified and directed for following sizes.
25 mm bore
20 mm bore
15 mm bore
M & L in repairs for water tubing or GI pipe , medium grade, galvanized, in trenchesor fixed on walls/ floors/ roofs etc with and including provision of all connected fittings complete all as specified and as directed.
25 mm bore
20 mm bore
15 mm bore
Supply and fix in repairs gun metal gate valves with iron wheel head screwed both ends for GI pipe all as specified for the following sizes:-
25 mm bore
20 mm bore
15 mm bore
Supply and fix in repairs Ball brass valves, high pressure, with polythene float and fly- nut complete for GI pipe/PPR pipe all as specified for the following sizes:-
25 mm bore
20 mm bore
15 mm bore
Jagdamba Engineering
ARUNOTHAYA TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .