Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.1 CrAccepted-AOC | ₹1.1 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹1.1 Cr+₹1.1 L (0.97%)Rejected-Finance HOUSE NO 251 E BLOCK ADARSH NAGAR BALLABHGARH FARIDABAD PIN 121004 HARYANA | FARIDABAD | FARIDABAD | HARYANA | 121004 | ₹1.1 Cr+₹1.1 L (0.97%) | L2 | Rejected-Finance OTHER THAN LOWEST |
| 3 | L3₹1.2 Cr+₹5.0 L (4.41%)Rejected-Finance 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹1.2 Cr+₹5.0 L (4.41%) | L3 | Rejected-Finance OTHER THAN LOWEST |
| 4 | L4₹1.2 Cr+₹6.1 L (5.41%)Rejected-Finance 13 29 3RD FLOOR EAST PATEL NAGAR NEW DELHI 110 008 | WEST | DELHI | 110008 | ₹1.2 Cr+₹6.1 L (5.41%) | L4 | Rejected-Finance OTHER THAN LOWEST |
| 5 | L5₹1.2 Cr+₹10.7 L (9.51%)Rejected-Finance | ₹1.2 Cr+₹10.7 L (9.51%) | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹1.4 Cr
EMD Value
₹2.8 L
Closing Date
18 Jun 2020, 6:00 pmClosed
CWE NO 2
CWE NO 2 DELHI CANTT
ADDN / ALTN AND IMPROVEMENT OF STANDBY POWER SUPPLY DG SET INFRASTRUCTURE WITH LT INFRASTRUCTURE AT BASE HOSPITAL UNDER GE (E/M) BASE HOSP, DELHI CANTT-10
2020_MES_343909_1
CWE/BH-03/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
GE (E/M) BASE HOSPITAL
₹2.8 L
Yes
6 Aug 2020
11 May 2020
20 Jun 2020
11 May 2020
18 Jun 2020
13 Jun 2020
Amount
Supply and install, testing and commissioning of diesel Engine driven generating set of 500 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures (should have salient features) modular bolted construction, & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure should be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary weather proof shead with MS pipe 80 mm dia for column and 40 mm dia MS pipe for beam and arms with CGI sheets and PCC foundations with block measonary work and plastering complete all as specified and directed by Engineer in charge with following specifications:- (A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 500 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002 the Engine shall consist of the following :-
(i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iV) Radiator with guard and water pump engine mounted (V) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan ( Blower type ) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters ( mounted) (xii) 12 v self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type ) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet. (xx) Instrument panel complete with following :- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure (k) Over speed stop with double driven adopter
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364 (ii) Type ;- Self excited self regulated with automatic voltage regulator . (iii) Rating :- 500 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition . (iv) Speed;- 1500 RPM (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected . (vii) Enclosure ;- Screen protected drip proof . (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H (C)CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 500 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS complete all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP;- Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two nos' 24 plates 12 v 180 AH (2 Nos) connected to the system fully charged including lead and bty terminal's complete . . (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer
o) DC Volt Meter 15/30 V - 01 No. p) DC Amp Meter 0-15 A. - 01 No. q) Trickle / Boost switch – 01 No. r) Auto/Manual switch -01 No. along with AMF Digital controller SCADA compactable with inbuilt RS 485 Port & Communication cable of Make : Procom Model No ECON-A-322 ( HSN :85030010 or equivalent in Deepsea/ Wood ward ) s) Start & Stop Push Button - 02 Nos. t) Frequency Meter – 01 No. u) Power Contactor 800 A 4 Pole 415V for DG. - 01 No. v) Power Contactor 800 A 4 Pole 415V for Main.- 01 No. w) MCCB 800 A 36 KA 4 Pole - 02 Nos. x) Control Relay - 01 Set. y) Over Load Relay 2.5-4A. – 01 No. z) Hooter 24 V DC - 01 No. aa) On load change over Switch 1000 A. for bye Pass Main Supply & DG – 02 Nos.
Supply and install, testing and commissioning of diesel Engine driven generating set of 320 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures (should have salient features) modular bolted construction, & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure should be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary weather proof shead with MS pipe 80 mm dia for column and 40 mm dia MS pipe for beam and arms with CGI sheets and PCC foundations with block measonary work and plastering complete all as specified and directed by Engineer in charge with following specifications:- (A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 320 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002 the Engine shall consist of the following :-
(i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iV) Radiator with guard and water pump engine mounted (V) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan ( Blower type ) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters ( mounted) (xii) 12 v self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type ) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet. (xx) Instrument panel complete with :- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure . (k) Over speed stop with double driven adopter .
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364 (ii) Type ;- Self excited self regulated with automatic voltage regulator . (iii) Rating :- 320 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition . (iv) Speed;- 1500 RPM (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected . (vii) Enclosure ;- Screen protected drip proof . (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H (C)CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 320 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS and all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP;- Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two nos' 24 plates 12 v 180 AH (2 Nos) connected to the system fully charged including lead and bty terminal's complete . . (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer
o) DC Volt Meter 15/30 V - 01 No. p) DC Amp Meter 0-15 A. - 01 No. q) Trickle / Boost switch – 01 No. r) Auto/Manual switch -01 No. along with AMF Digital controller SCADA compactable with inbuilt RS 485 Port & Communication cable of Make : Procom Model No ECON-A-322 ( HSN :85030010 or equivalent in Deepsea/ Wood ward ) s) Start & Stop Push Button - 02 Nos. t) Frequency Meter – 01 No. u) Power Contactor 630 A 4 Pole 415V for DG. - 01 No. v) Power Contactor 630 A 4 Pole 415V for Main.- 01 No. w) MCCB 800 A 36 KA 4 Pole - 02 Nos. x) Control Relay - 01 Set. y) Over Load Relay 2.5-4A. – 01 No. z) Hooter 24 V DC - 01 No. aa) On load change over Switch 800 A. for bye Pass Main Supply & DG – 02 Nos.
Supply and install, testing and commissioning of diesel Engine driven generating set of 160 KVA capacity 3 phase, 4 wire, 415 V, 1500 RPM AC power supply with power factor 0.8 coupled directly to alternator mounted on a common base plate complete with integral acoustic enclosures (should have salient features) modular bolted construction, & pure polyester based coating to ensure long life in all weather conditions & for outdoor application / installation, integrated design thereby facilitating / easy handling. The design of integral acoustic enclosure should be approved by National Physical laboratory as per central pollution control board (CPCB) latest regulation / norms with fuel tank, battery & standard accessories, tools & spares as provided by manufacturer complete with necessary weather proof shead with MS pipe 80 mm dia for column and 40 mm dia MS pipe for beam and arms with CGI sheets and PCC foundations with block measonary work and plastering complete all as specified and directed by Engineer in charge with following specifications:- (A) ENGINE- Water cooled diesel engine of at 1500 RPM capacity to match the 160 KVA alternator under NTP conditions with provision of 10 % over load for 1 hour in every 12 hours running confirming to BS 5514/ IS 10001/ 10002 the Engine shall consist of the following :-
(i) Fly wheel with starter ring (ii) Flexible coupling with guard (iii) Cooling fan (iV) Radiator with guard and water pump engine mounted (V) Dynamo of suitable capacity (vi) Air cleaner heavy duty dry (vii) Fuel injection pump (viii) Radiator fan ( Blower type ) with guard (ix) Mechanical governor (x) Fuel filter (Mounted) (xi) Lubricating oil filters ( mounted) (xii) 12 v self regulating alternator belt driven by engine (xiii) Exhaust silencer heavy duty residential type (xiv) Corrosion resistor /scale inhibitor (xv) Starter 12 V DC (xvi) Lubricating oil cooler (xvii) Lubricating oil pump (Gear type ) (xviii) Turbo charger (xix) Exhaust piping shall be insulated with asbestos rope duly cladded with aluminium sheet. (xx) Instrument panel complete with :- (a) Auto manual Starting switch with key (b) Lubricating oil temperature gauge (c) Lubricating oil pressure gauge (d) Water temperature gauge (e) Battery charging ammeter (f) Battery charging indicating lamp (g) Hour meter with RPM indicator (h) Safety control against high temperature of water. (j) Safety control against low lubricating oil pressure . (k) Over speed stop with double driven adopter .
(B) BRUSH LESS ALTERNATOR (i) Alternator coupled to engine indigenous make through a flexible coupling mounted on sturdy steel fabricated base frame suitable for mounting on a permanent foundation brushless alternator shall be confirming to BS -2613 or relevant of IS-4722/ IS 13364 (ii) Type ;- Self excited self regulated with automatic voltage regulator . (iii) Rating :- 160 KVA at 0.8 PF lagging 4 pole horizontal at NTP condition . (iv) Speed;- 1500 RPM (v) System :- 415 V +/- 2.5 % AC 3 phase 4 wire 50 Hz. (vi) Connection :- 4 wire star connected . (vii) Enclosure ;- Screen protected drip proof . (viii) Ventilation :- Self ventilated. (ix) Insulation :- Insulation class H (C)CONTROL PANEL The control panel with aluminium bas bar, bottom entry and exit of cable, current transformer, set of control fuses, Multifunctional Meter, it should display time and date, Volts, Frequency, Current, KW, KWH, PF, RPM, Cumulative Run Hours, Oil Pressure, Coolant Temp, Charging current (DC Amp Meter). Emergency off, factory made floor mounted, totally enclosed, epoxy powder coated suitable for 160 KVA DG Set including all necessary operating controlled devices as stated above and MCCBs as out going with protection fuse for panel instruments duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as per latest IS/BS and all as specified and directed.
(D) ONE SET OF ACCESSORIES COMPRISING OF :- (a) Fuel tank -one No. fabricated with 3 mm thick MS sheet with necessary mild steel structure for mounting the tank higher than the DG set) with piping. Capacity of tank shall be to hold diesel sufficient for 16 hours running at full load, with following features (i) Level indicator. (ii) drain plug . (iii) MS class 'C' piping for inlet from pump to tank to engine. (iv) Fuel strainer. (v) Air vent. (b) Fuel PUMP;- Electrical operated fuel pump for filling diesel in the tank of adequate capacity with inlet connection to the tank with 5 meter flexible hose pipe heavy duty for suction of diesel from barrel. (c) Sealed maintenance free Battery :- Heavy duty battery two nos' 24 plates 12 v 180 AH (2 Nos) connected to the system fully charged including lead and bty terminal's complete . . (d) Base plate :- Fabricated out of MS channel's ISMC of suitable size suitable for fixing of DG set all specified by the manufacturer
o) DC Volt Meter 15/30 V - 01 No. p) DC Amp Meter 0-15 A. - 01 No. q) Trickle / Boost switch – 01 No. r) Auto/Manual switch -01 No. along with AMF Digital controller SCADA compactable with inbuilt RS 485 Port & Communication cable of Make : Procom Model No ECON-A-322 ( HSN :85030010 or equivalent in Deepsea/ Wood ward ) s) Start & Stop Push Button - 02 Nos. t) Frequency Meter – 01 No. u) Power Contactor 320 A 4 Pole 415V for DG. - 01 No. v) Power Contactor 320 A 4 Pole 415V for Main.- 01 No. w) MCCB 400 A 36 KA 4 Pole - 02 Nos. x) Control Relay - 01 Set. y) Over Load Relay 2.5-4A. – 01 No. z) Hooter 24 V DC - 01 No. aa) On load change over Switch 400 A. for bye Pass Main Supply & DG – 02 Nos.
Supply, installing, testing and commissioning of Outdoor type Feeder Piller floor mounted made out of 3.15 mm thick CRCA sheet suitable for 415 volt, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated Aluminium Bus bars of rating 1200 Amps mounted on epoxy/SMC type insulator and the minimum inside depth of panel is not less than 500mm. The panel shall be dust and vermin proof IP 54 class protection and make of 14 SWG CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work 90 Cm height and grouded 45 Cm in PCC , powder coated finish outside and inside, both side (front and rear)openable type for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable IS 694 marked of adequate size but not less than 1.5 sq mm complete with the following incoming and outgoing feeders Note:- PCC & Excavation inclusive in qouting rates (a) Incoming :- (i) ACB TP + NL , LT 415 Volts, 50 Hz, AC grade, 800Amps rating and 50 KA : 01 Nos. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,320 amps rating and 36 KA rupturing capacity. Nos - 03 (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,200 amps rating and 36 KA rupturing capacity. Nos - 02 (iii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,100 amps rating and 25 KA rupturing capacity. Nos - 04 (iv) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,63 amps rating and 25 KA rupturing capacity. Nos - 02
Supply, installing, testing and commissioning of Outdoor type Feeder Piller floor mounted made out of 3.15 mm thick CRCA sheet suitable for 415 volt, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated Aluminium Bus bars of rating 500 Amps mounted on epoxy/SMC type insulator and the minimum inside depth of panel is not less than 500mm. The panel shall be dust and vermin proof IP 54 class protection and make of 14 SWG CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work 90 Cm height and grouded 45 Cm in PCC , powder coated finish outside and inside, both side (front and rear)openable type for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable IS 694 marked of adequate size but not less than 1.5 sq mm complete with the following incoming and outgoing feeders Note:- PCC & Excavation inclusive in qouting rates (a) Incoming :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 800Amps rating and 36 KA : 01 Nos. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,320 amps rating and 36 KA rupturing capacity. Nos - 03 (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,200 amps rating and 36 KA rupturing capacity. Nos - 03 (iii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,100 amps rating and 25 KA rupturing capacity. Nos - 02
Supply, installing, testing and commissioning of Outdoor type Feeder Piller floor mounted made out of 3.15 mm thick CRCA sheet suitable for 415 volt, 3 phase 4 wire 50 Hz, AC supply system having bus bar chamber with duly insulated Aluminium Bus bars of rating 500 Amps mounted on epoxy/SMC type insulator and the minimum inside depth of panel is not less than 500mm. The panel shall be dust and vermin proof IP 54 class protection and make of 14 SWG CRCA sheet and 50 mm x 50 mm x 6mm thick angle iron frame work 90 Cm height and grouded 45 Cm in PCC , powder coated finish outside and inside, both side (front and rear)openable type for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated flexible copper conductor FRLS cable IS 694 marked of adequate size but not less than 1.5 sq mm complete with the following incoming and outgoing feeders Note:- PCC & Excavation inclusive in qouting rates (a) Incoming :- (i) MCCB TP + NL , LT 415 Volts, 50 Hz, AC grade, 250Amps rating and 36 KA : 01 Nos. (b) Outgoing:- (i) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,200 amps rating and 36 KA rupturing capacity. Nos - 01 (ii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,160 amps rating and 25 KA rupturing capacity. Nos - 02 (iii) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,100 amps rating and 25 KA rupturing capacity. Nos - 02 (iv) MCCB 4 pole , LT 415 Volts, 50 Hz, AC grade,63 amps rating and 25 KA rupturing capacity. Nos - 01
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 300 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 240 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 120 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 95 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 70 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply & lay XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable ISI marked with aluminium multistranded conductor 1100 volt grade of size 50 Sqmm 3.5 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc including taking down old cable complete all as specified & directed.
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 400 Amps with sheet metal enclosure and extensible handle and accessories complete all as specified and directed by Engg-In charge. Make: Havells Model No IHCNFO0400 or equivalent in L&T/ Siemens/ Schinder/ C&S Electric/ ABB
Supply and fix ON LOAD change over switch 415V in sheet metal enclosures 4 pole of capacity 630 Amps with sheet metal enclosure and extensible handle and accessories complete all as specified and directed by Engg-In charge. Make: Havells Model No IHCNFO0630 or equivalent in L&T/ Siemens/ Schinder/ C&S Electric/ ABB
Material and labour for earthing complete with gavanised steel earth plate electrode 60 cm x 60 cm x 6.3 mm thick burried directly into ground ( earth pit not less than 2.25 Mtrs below gorund level) with top edge of the plate not less than 1.5mtr beolw normal ground level, connected to galvanised earth strip 32 x 6mm size upto a distance of 7.5 mtr long by means of bolts, check nuts and washers of galvnised iron or steel all as shown in electrical plate no 5 at SSR Part-I of 2009 connected to earthing test point all as specified and indicated and testing complete including execvation earth work drilling holes for electrode PCC pit & cover , funnel , water pipe , lugs etc. complete all as specified and directed by Engg in charge Note: Quoted rates shall be deem to include for earth wire with protection pipe up to 7.5 M length.
M & L For shifting of 320 KVA DG as following directed by engineer in charge:- 1. Dismantling of DG complete and its connected assessories( all tpes of cables, change over, panels , AMF Panels and switch gears) from its existing location with cranes and necessery tools and manpower. 2. Making of necessery platform with brick work and PCC for installation of DG set at location specified by engg -in-charge of 4 feet (2 feet underground and 2 feet above the ground) with necessary PCC sub base foundation and morrum filling in brick mesonary work etc 3. Shifting of DG complete and its connected assessories to New location with distance of 2 KM as directed. 4. Testing and commissioning of DG complete as directed by engineer in charge.
Excavation in trenches not exc 1.5 m wide and n.exc 1.5 m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified and directed.
Returning filling in including spreading, levilling, watering and well ramming in layers, not exeecding 25 cm thick using excavated soil complete all as specified and directed.
Removing excavated Soil to a distence not exceeding 50 m and deposting where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning to under ground electric cable including punning down of sand in layer complete all as specified and directed. Note: for measurement purpose punned thicness of sand only will be considered.
Supply and Laying burn brick size 225 mm X 113 mm X 75 mm etc complete all as specified and directed.
M&L for Boring of holes under road pavement hard standing by trenchless technology using latest technique and necessary machine including laying / insetion of HDPE pipe ISI Marked of 150 mm dia complete all as specified and directed by Engg -in-Charge Note: All RCC / PCC work for boring of hole under the road crossing will be included in the scope of work .
Material & labour for GI steel tubing light grade for protection of cable/ earth continuty conductor fixed to poles/ walls/ roof or laid in floors, road, crossing or ducts fixed with clamps , bolts nuts and wahser etc complete all as specified and directed for following bore of pipes of size 80mm dia complete all as specified and directed.
national engineering
M/S ANIL KUMAR
Leo Air and Power Solution pvt Ltd.
AMIT ASSOCIATES
M/S Sunil Steel Works
Third Wave Services Pvt Ltd
SANJEEV ENTERPRISES
Powerlite Engineers
M P TYAGI ENGINEERS AND CONTRACTORS
mayur enterprises
N K BUILDERS
JAZZCON ENGINEERS PVT LTD
L G BUILDERS
Ashish Sehgal and Co.
Adhunik Builders
M/s VINOD KUMAR SHARMA
R D Bansal
tarun construction co
M/s R. K. Bhambri
stage.html
html • 0.11 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .