| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.1 LAccepted-AOC 1 TROPICAL REFRIGERATION PHONIX BAY PORT BLAIR PORT BLAIR ANDAMAN NICOBAR 744101 | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹39.1 L Quoted ₹39.5 L | L1 | Accepted-AOC Being the lowest |
| 2 | L2₹43.7 L+₹4.2 L (10.6%)Rejected-Finance | ₹43.7 L+₹4.2 L (10.6%) | L2 | Rejected-Finance Not being the lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Feb 2020, 6:00 pmClosed
Shri Rajiv Ranjan, IDSE
GE, Minniebay, Junglighat (PO), Port Blair -744103
REPAIR/REPLACEMENT OF WINDOW TYPE AC, SPLIT AC, VERTICAL AC, WATER COOLER, REFRIGERATOR, COOL AND COLD STORAGE AND WATER PURIFIER AT GE MINNIEBAY, PORT BLAIR (8829/E8)
2020_MES_315996_1
8829 GE MB PB
Open Tender
Civil Works
Item Rate
180 days
GE, Minniebay, Junglighat (PO), Port Blair -744103
As per tender documents
8 documents required · 8 mandatory
₹500
Yes
GE, Minniebay, Junglighat (PO), Port Blair -744103
₹90,000
Yes
29 Feb 2020
18 Jan 2020
15 Feb 2020
18 Jan 2020
13 Feb 2020
6 Feb 2020
Amount
M&L for servicing of window type Air Conditioner 1.0/1.5/2.0 Ton capacity of any make including taking out the machine from its original location, removing the dust from body with blower, cleaning/ washing the condenser & cooling coil complete by using water and caustic soda, cleaning of entire elements of AC, oiling/ greasing to fan motor, checking all the connections and functioning of metal clad socket/ DP switch function of relay capacitors, overload protector, thermostat fan motor blade, fan/ blower drum, etc., checking serviceability, changing the air filter woolen felt for air tighting, refixing the machine at its original location, necessary testing and commissioning complete all as specified and as directed.
M&L for servicing of split type Air Conditioner 1.5/ 2.0TR capacity of any make including taking out the machine from its original location, removing the dust from body with blower, cleaning/ washing the condenser & cooling coil by using water and caustic soda, cleaning of entire elements of AC, oiling/ greasing to fan motor, checking all the connections and functioning of metal clad socket/ DP switch function of relay capacitors, overload protector, thermostat fan motor blade, fan/ blower drum, etc., checking serviceability, changing the air filter woolen felt for air tighting, refixing the machine at its original location, necessary testing and commissioning complete all as specified and as directed.
Supply & install in replacement of Indoor Unit only for Split AC of capacity 1.5/ 2.0 Ton including necessary accessories and connections complete all as specified and as directed.
Taking down carefully the Split AC from original location,shifting to other location and install the AC with copper tubing, filling of gas required, making hole in wall for copper tubing with all necessary connections and making good the disturbed surfaces of wall all as specified and as directed. Note : Gas & Copper tubing shall be measured and paid separately under respective item of this Schedule as "Supply only".
M&L for servicing of indoor & outdoor unit of split type AC 3.5/ 4.5 TR capacity complete with soda wash to condenser & cooling coil, cleaning of entire elements of AC, oiling/ greasing to condenser motor, cooling coil, blower motor, including taking out and refixing the machine at its original location complete all as specified and as directed.
M&L for servicing to water cooler of any capacity after disconnecting the water cooler from electric and water supply, cleaning the condenser unit with use of liquid solution, cleaning the condenser coil, greasing the fan motor, checking/repairing the electric wiring throughly, cleaning of water storage tank, replacement of push cook washer, etc., complete all as specified and as directed.
S&F in repair, charged new sealed unit compressor for refrigerator of capacity 286/310 ltr of approved make, 230Volts, AC including taking out old unserviceable, burnt out sealed unit compressor by means of unscrewing foundation nut & bolts, disconnecting from suction & discharge side mechanically and electrically including testing and charging the system with gas, etc., complete all as specified and as directed. Note : Gas shall be measured and paid separately under respective item of this Schedule as "Supply only". [Make : Hitachi/ Danfoss/ Kiloskar or equivalent as approved by OEM & GE]
All as per Item 7 above, but Compressor for Water cooler of capacity 40/80 Ltr
All as per Item 7 above, but Compresor for Window/Split type AC of capacity 1.5 TR
All as per Item 7 above, but Compressor for Window/split type AC of capacity 2 TR
All as per Item 7 above, but Compressor for Window/split type AC of capacity 3.5 TR
All as per Item 7 above, but Compressor for Window/split type AC of capacity 4.5 TR
S&F in repair/ replacement of Thermostat No 2059 with knob for window type AC all as specified and as directed. [Note : The quoted rate shall be deemed to include for taking out old unserviceable spares/ item and provision of new spares/ item.]
All as per Item 13 above but OLP-1622 relay for window type AC.
All as per Item 13 above but Potential box type relay/PTC relay of suitable model for window/split type AC.
All as per Item 13 above but Running capacitor 36 to 50 MFD, for Window/Split AC 1.5 TR
All as per Item 13 above but Running capacitor 36+6 MFD for Window/Split AC 2 TR
All as per Item 13 above but Running capacitor 50+6 MFD for Window/Split AC 2 TR
All as per Item 13 above but Running capacitor 45+6 MFD for Window/Split AC 2 TR
All as per Item 13 above but Running capacitor 50/60 MFD for Window/Split AC 2 TR
All as per Item 13 above but Running capacitor 6 to 10 MFD for Window/Split AC 2 TR
All as per Item 13 above but Running capacitor 2.5 to 4 MFD for Window/Split AC 2 TR
All as per Item 13 above but Metal top for sheet metal enclosure
All as per Item 13 above but Condenser assembly with copper tubing suitable for 1.5/2 TR compressor of existing size and base mounting. [Make : Blue Star or equivalent model]
All as per Item 13 above but Stand for Condenser motor in outdoor unit for 1.5/2 TR AC
All as per Item 13 above but PC board complete suitable for existing model of split AC of 1.5/2/2.5 TR capacity (as per sample)
All as per Item 13 above but Plasma filter suitable for existing model of split AC of 1.5/2/2.5 TR capacity (as per sample)
All as per Item 13 above but Blower motor, 230Volts, AC of indoor unit of split type AC of 1.5/2 TR Capacity.
All as per Item 13 above but Remote control complete suitable for existing model of split AC of 1.5/2/2.5 TR capacity (as per sample)
All as per Item 13 above but Fan/ blower motor, double shaft of window type AC of 1.5/2.0 TR capacity, single/ double speed, single phase, 230Volts, AC of 1/4 to 1/5 HP, complete and making suitable fixing arrangement in existing place including taking out burnt/ unserviceable fan/ blower motor of any type complete.
All as per Item 13 above but single shaft outdoor unit blower fan motor of split type AC of 1.5/2.0 TR capacity, single/ double speed, single phase, 230Volts, AC of 1/5 to 1/6 HP, complete and making suitable fixing arrangement in existing place including taking out burnt/ unserviceable fan/ blower motor of any type complete.
All as per Item 13 above but Fan blade (as per sample) for window type AC/Split AC of any capacity.
All as per Item 13 above but Front grill assembly complete suitable for existing model of window AC of any capacity including taking out broken/damaged front grill assembly.
M&L for MS sheet plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment of Fe 410-W (Gde-E-250) quality-A complete all as specified and as directed.
S&F in repair/replacement of Thermostat No 2064 with knob in Water Cooler all as specified and as directed. [Note : The quoted rate shall be deemed to include for taking out old unserviceable spares/item and provision of new spares/ item.]
All as per Item 35 above but Relay kit as per sample, No 412Y/512Y or equivalent.
All as per Item 35 above but Condenser fan motor, single shaft 1/35 HP capacity, single phase, 230Volts, AC including taking out burnt out condenser fan motor.
All as per Item 35 above but Condenser fan motor, single shaft 1/83 HP capacity, single phase, 230Volts, AC including taking out burnt out condenser fan motor.
All as per Item 35 above but Drain water tray with 40mm PVC flexible pipe of existing length and circlip complete for water cooler of any capacity as per sample including taking out broken drain water tray.
All as per Item 35 above but Chromium plated brass push cock, 15mm dia.
All as per Item 35 above but Fan blade (as per sample) for water cooler of any capacity.
All as per Item 35 above but Float valve complete for water cooler of any capacity.
All as per Item 35 above but Inlet of 15mm bore PVC connection heavy duty 600mm long with brass coubling for water cooler of any capacity.
S&F in repair/replacement of Auto 'D' thermostat No 1027 with knob in Refrigerator all as specified and as directed. Note : Quoted rate shall be deemed to include for taking out old unserviceable spares/item and provision of new spares/ item.
All as per Item 44 above but Relay kit (OLP + LMS relay or box type) as per sample [Make : Danfoss]
All as per Item 44 above but Cooling coil of Refrigerator of 286/310 litres capacity complete.
All as per Item 44 above but Bimetallic timer suitable for any model
All as per Item 44 above but Heater suitable for any model.
All as per Item 44 above but Bulb suitable for any model.
S&F exhaust fans totally enclosed, highly efficient AC Single Phase 230 V capacitor run heavy duty motor Single piece metallic blade of size 600 mm sweep (Heavy duty), including louvers/shutter and connecting up 3 core flexible cord of size 1.5sqmm from ceiling rose to exhaust fan all as specified and directed. Make : Usha, Bajaj & CG
S&F in repair/ replacement of sheet metal enclosure with socket plug top & MCB single pole and neutral enclosure with a two pin and earth plug & socket complete with one single pole MCB 20Amps all as specified and as directed.
S&F in repair/replacement of FRLS cable 1100Volts grade 3 core, 2.5sqmm, multirstranded Copper conductor, PVC insulated from main supply point to outdoor unit point all as specified and as directed.
M&L in repair/replacement of Copper tubing of size 5/8" flare size conforming to relevant IS all as specified and as directed.
All as per Item 53 above but 1/2" flare size.
All as per Item 53 above but 3/8" flare size.
M & L for insulation of copper tubing for split unit of any capacity & any size from indoor to out door unit complete all as specified and as directed.
M&L for leak testing one in number walk-in-freezer/walk-in-cooler comprising of condenser units and evaporator units with pressure testing the complete plant by dry nitrogen gas by separating high side and low side, brazing and low side, rectifying the leakage by gas welding, brazing, pressure testing, vaccumising gas, gas charging the system with existing Refrigerant gas, testing and commissioning all as specified and as directed.
M&L for preparation of old painted outside surfaces of Cold Storage Room located at various places by means of scrapping and filling cavities, etc., and applying two coats of synthetic enamelled paint by means of spray painting and writing SM/MES No., capacity, temperature range, etc., all as specified and as directed.
M&L in repair/replacement of aluminium chequered plate 3mm thick including aluminium strip of size 25x3mm fixed on floor over plywood inside the cold storage rooms located at various places with necessary supports and fixture & fittings like self threaded bolt, screws, etc., complete all as specified and as directed. Note : Plywood shall be measured and paid for separately as "M&L in repair/ replacement" under respective items of this schedule.
M&L in repair/ replacement of plywood grade boiled water resistant (BWR) proof, Type BB, 19mm thick, laying inside the cold storage rooms located at various places for preparation of floor surfaces complete all as specified and as directed.
Supply, install, test and commissioning in repair/ replacement hermitically sealed unit compressor 4.5/5 TR capacity as approved by OEM & GE suitable for working on R-22 gas including charging the system with gas, taking out old unserviceable hermitically sealed unit compressor 4.5/5 TR capacity, 3 phase, 440Volts, AC from outdoor unit of cold storage by means of disconnecting the suction and discharge refrigerant pipe line, electrical connection, etc., complete all as specified and as directed. [Make : Kirloskar/ Danfoss/ Copeland/ Hitachi]
All as per Item 61 above, but suitable for working on R-134A gas
All as per Item 61 above, but compressor of 4.5TR capacity of Make:Danfoss suitable for working on R-404A gas.
All as per Item 61 above, but compressor of 5TR capacity of Make:Danfoss suitable for working on R-404A gas.
M&L in repair of steel door in cold/cool storage plant including dismantling the door, taking out old insulated material and replacing with new glass wool, puff, external sheet, cotton of adequate size & quantity and replacing PVC insulated Copper conductor electric wire for lighting, door locks/ hinges, sealing gaskets, door heaters, etc., reassembling with steel door and reinstall as required at site complete all as specified and as directed.
S&F in repair/ replacement of Condenser fan motor, single shaft, single speed, 1400RPM, 230Volts AC, suitable for 4.5/5TR capacity Cold Storage Plant as per OEM including taking out burnt/ unserviceable condenser fan motor all as specified and as directed.
S&F in repair/ replacement of Single phase preventor suitable for 4.5/5TR capacity Cold Storage Plant all as specified and as directed. [Model : VSP-D1 of Make : Milnilec or equivalent model] Note : The quoted rate shall be deemed to include for taking out old unserviceable spares/item and provision of new spares/ item.
All as per Item 67 above but Single phase preventor. [Model : VSP-D2 of Make : Milnilec or equivalent model]
All as per Item 67 above but Over load relay direct mounting type of range 2-3.2Amps as per OEM.
All as per Item 67 above but Defrost delay timer with switch [Make : L&T or equivalent model]
All as per Item 67 above but Thermostat unit for cold storage suitable on working 12˚C to 2˚C for defrost and (minus) (-) 5˚C at 'ON' condition as per OEM.
All as per Item 67 above but Condenser assembly with copper tubing suitable for 4.5/5 TR compressor of existing size and base mounting [Make : Bluestar or equivalent model]
All as per Item 67 above but Cooling coil assembly for indoor unit with copper tubing suitable for 4.5/5 TR compressor of existing size and base mounting. [Make Bluestar or equivalent model]
All as per Item 67 above but Tray heater suitable for existing cold room [Make : Bluestar or equivalent model]
All as per Item 67 above but Analog switch timer [Make : L&T or equivalent]
All as per Item 67 above but Phase failure relay [Model : VSP D1; Make L&T or equivalent]
All as per Item 67 above but Thermostat unit for cold storage suitable on working 10˚C to 20˚C for defrost and (minus) (-) 5˚C at 'ON' condition as per OEM.
All as per Item 67 above but Subzero display [Model : SZ-7510-P; Make : Scientific]
All as per Item 67 above but HP LP cutout [Make : Danfos]
All as per Item 67 above but Thermal expansion valve [Make : Danfoss]
All as per Item 67 above but Eleminator liquid line filter drier model DCL 162 [Make : Danfoss]
All as per Item 67 above but MCB TPN 32Amps. [Make : Standard /Legrend/L&T]
All as per Item 67 above but MCB, SP 06 to 32 Amps. [Make : Standard /Legrend/L&T]
All as per Item 67 above but Ammeter Analog as per existing size and range 0 to 100Amps
All as per Item 67 above but Voltmeter Analog as per existing size and range 0 to 500Volts
All as per Item 67 above but RYB indicator Lamp, LED type as per existing size
All as per Item 67 above but Mushroom button as per existing size & capacity
All as per Item 67 above but Phase failure overload protection of range 20Amps [Model : MPR- 1; Make : Minilec]
All as per Item 67 above but Evaporator fan of size 34x34x19, [Model No : YMF4E400SC; Make : Axiel]
All as per Item 67 above but Evaporator fan of size 50x50x22, Type REC4E-450A [Model No : YDWF68M4-360N-300 Section]
S&F in repair, evaporator coil indoor unit tray heater 'U' type, 2105mm long constant wattage with 1 metre 3 core, multi-stranded copper conductor, 4sqmm, FRLS PVC sheathed cable and cold shrink sleeve all as specified and as directed.
S&F in repair Voltage Stablizer of 5KVA capacity for automatic operation single phase naturally air cooled, indoor type, designed for input variation between 170V to 250V with output voltage stablizeed at 230V with accuracy of 2.5% complete all as specified and as directed. Make : Guardian/ V Guard/ Everest or equivalent. [Note : Old unserviceable voltage stabilizers are to be deposited to MES store.]
All as per Item 92 above, but 4 KVA capacity
S&F in repair drain outlet PVC pipe 15mm dia connected from rear side of AC upto drain with necessary clamps and fixtures, fixed on wall and floor complete all as specified and as directed.
M&L for Servicing of water purifier (KENT RO system) 15 ltr/ hour capacity complete including cleaning of filters (i.e. in-house filter, sediment filter, carbon filter) checking of membrane of UV tube, replacement of auxillary unserviceable parts, etc., all as specified and directed by Engineer-in-Charge. Notes : (i) Spare parts shall be measured and paid separately under relevant item as "Supply only". (ii) The quoted rate includes service warranty upto one year from the date of service for attending and rectify the defects on no cost basis during warranty period.
Supply only the In house filter (Pre filter) complete with hose and all accessories for water purifier (KENT RO system) as per OEM
All as per Item 96 above, but UV Tube
All as per Item 96 above, but Cartridge of sediment filter
All as per Item 96 above, but Cartridge of carbon filter
All as per Item 96 above, but Cartridge of pre filter
All as per Item 96 above, but Adopter 12Volts AC to DC suitable for Kent RO system 15ltrs/hour
All as per Item 96 above, but Membrane 50 GPO
All as per Item 96 above, but Membrane 75 GPO
All as per Item 96 above, but Pump suitable for Kent RO
Supply only Compressor oil N-68. [Make : SERVO, Sheetal or equivalent as approved by GE]
Supply only Refrigerant gas R-22 in manufacturer's sealed cylinder.
Supply only Regrigerant gas R-404 A in manufacturer's sealed cylinder.
Supply only Refrigerant gas R-134A in manufacturer's sealed cylinder. Notes for Item Nos 106 to 108 : Empty cylinder shall be returned to contractor. (ii) Payment shall be made for net weight of gas.
M&L for servicing of online single phase UPS of 5KVA capacity of any make including taking out the machine from its original location, removing the dust from body with blower, oiling/ greasing to fan motor, checking all the connections and functioning of metal clad socket/ DP switch function of relay, overload protector, thermostat, fan motor blade, fan/ blower drum, etc., checking the serviceability including replacement of unserviceable spare parts complete, refixing the machine at its original location, necessary testing and commissioning all as specified and as directed.
S&F in replacement maintenance free Lead Acid Battery suitable for online UPS 5KVA including first charging of battery of capacity 12Volts complete all as specified and as directed.
M&L for servicing of online single phase UPS of 40KVA capacity of any make including taking out the machine from its original location, removing the dust from body with blower, oiling/ greasing to fan motor, checking all the connections and functioning of metal clad socket/ DP switch function of relay, overload protector, thermostat, fan motor blade, fan/ blower drum, etc., checking the serviceability including replacement of unserviceable spare parts complete, refixing the machine at its original location, necessary testing and commissioning all as specified and as directed. Note: 1. Servicing to be done by Authorised technician from manufacturer. 2. Transportation charges paid to be technician for journey carried out from/to mainland is to included in the quoted rate. 3. The bidder has to provide a warranty certificate for a period of 12 months from the date of servicing.
EVEREST COOLING WORKS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .