Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.3 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.9 L+₹2.6 L (13.4%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹26.0 L+₹6.7 L (34.8%)Rejected-AOC ROOM NO 214 GANESH MURTHY NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L3 | Rejected-AOC L3 | |
| 4 | L4₹26.7 L+₹7.4 L (38.4%)Rejected-AOC | L4 | Rejected-AOC L4 | |
| 5 | L5₹27.0 L+₹7.7 L (40.2%)Rejected-AOC MATHOSHREE PLOT NO 55 SR NO 787 A BEHIND ASHWANI HOSPITAL GOVIND NAGAR NASIK 422 009 | NASIK | NASHIK | MAHARASHTRA | 422009 | L5 | Rejected-AOC L5 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
5 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Kislay Kishore, IDSE
GE (AFA) Hyderabad PIN-500043
ADDN/ALTN TO AREA LIGHTING AT FLIGHT CADET MESS AND CERTAIN ELECTRIC SERVICES OF POWER POINT IN FCM DINING HALL AT AFA HYDERABAD
2022_MES_518377_1
8244/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AFA) Hyderabad
As per tender documents
4 documents required · 4 mandatory
₹500
GE (AFA) Hyderabad
₹40,000
Yes
23 Jul 2022
16 Apr 2022
7 May 2022
16 Apr 2022
5 May 2022
27 Apr 2022
16 Apr 2022 - 26 Apr 2022
60 days
Amount
Excavation in trenches in any kind of soil n.exc 1.5 m wide and n. exc 1.5 m depth and getting out, including trimming the sides and forming bottom surface to required levels for laying cables complete all as specified and as directed.
Returning, filling in trenches in any kind soil in layers n.exc. 25 cm after laying of cables including spreading, levelling, and well ramming complete all as specified and directed.
Removing surplus soil to a distance exc 1.5 KM and n exc 5 KM and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
S & Laying Low Density Poly Ethylene (LDPE) flexible pipe of 40 mm dia and of pressure rating 6 Kg/cm² laid inside the P.C.C. coping of poles for easy bending and passing of cables including clamping in a proper way including old unserviceble LDPE pipe all as specified and directed.
Supply and laying GI tubing of 50 mm bore ,light grade with all fittings for protecting the cables laid in tranches,floors,on poles,in walls all as specified and directed.
Supply and Laying in replacement of XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 10 Sqmm 4 core including taking down of unserviceable cable all as specified and directed..
S & F (in repairs) cable junction box 167 x 125 x 82 mm in size, made out of thermoplastic, having IP 65 protection for outdoor installation fixed with 4 way bakelite cable terminals including 03 Nos polymide gland with check nut (M-32-02 N0 & M- 25 -01 N0 ) fixed on poles with aluminium clamps of size 25 x 3, unts, bolts, washers etc., including taking out of old unserviceable cable junction box complete all as specified and as directed Make Cat No . D-9100 of HENSEL or equivalent in SPELSBERG / RITTAL/ SINTEX.
Supply and fixing IP65 rated inverted Pyramid Tripod type Bollards fitting with soft 3600 ligth distribution including nuts, bolts and washers for fixing complete including all fixing arrangements/ footing/ foundation up to 0.45 metre above ground level all as directed by Eng-in-charge and icnluding taking down old unserviceable bollard lights Make Crompton No. - LBLSN -10 -CDL or equivalent
Supply and fix ( in repairs) MCB single pole and neutral, 240 volts, 32 Amps, all as specified and as directed.
Supply and fix (in repairs) MCB single pole 240 volts, 5 to 20 Amps, all as specified and as directed.
Taking down old unserviceable sub main wiring any type any size all as specified and as directed.
M&L for Sub Main wiring with two runs of 2.5 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable size with all necessary fittings,on surfaces of walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
M&L for earthing complete with Galvanised steel earth plate eletrode 600 mm x 600 mm x 6 mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below GL) with top edge of earth plate not less than 1.5 Mtr below normal ground level, earth plate surrounded from all sides by 15cm thick packed layer of charcoal dust and common salt filled in alternate layers and electrode connections by using Galvanised iron 32 x 6 mm strip connected by means of bolts, nuts, check nuts and washer of galvanised iron or steel, provision of 40mm dia GI pipe medium grade for protection of GI earth strip and 20mm dia GI pipe medium grade for watering arrangement and PCC (1:3:6) type C1 chamber of size 45cm X 45cm X 45cm including, MS funnel, wire mesh, 50 mm thick RCC 1:2:4 type B1 earth pit cover with 6 Nos, 8 mm dia high strength deformed steel TMT bars on both ways including necessary excavation in any type of soil, returning, filling in, removal of surplus soil to distance n exc 50 mtr, provision of charcoal and salt complete all as shown in electrical plate No 3 of MES Schedule Part-I (2009) and all as dircted. Note:- (i) Cost of GI earth strip and GI protection pipe upto 7.5mtr length shall be deemed to be included in the rate quoted for this item. (ii) The unit rate shall also includes for Wire mesh, funnel, excavation, returning filling , removing , PCC chamber pit, RCC cover, test point etc.
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 100 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron)with approved shade oRAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable. The feeder pillar shall be comprising of the followings :-
(i) MCCB 4 pole 63 Amps, 35 KA, 415 Volts - 01 Nos
(iv) MCB,TP,63A,10kA-02Nos
(v) Astronomical time switch daily 1 channel having in built mechanism for calculating sun rise /sun set timing of a particular place suitable for 240 V AC supply - 01 No
(vi) 3 Pole power contactor of AC 3 duty rating of 40 amps having 240 volts rated coil and having 2 NO + 2 NC - 01 Nos
(vii) LED indicating lamps with holder for main supply - 1Set of 3
(viii) Instrumental control wiring with MCB 2 Amps - 03 Nos
(x) ON/OFF Push Buttons -02Nos.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sq mm 3½ core
Design, supply, erection, testing and commissioning of outdoor type LT feeder pillar box platform mounted (to be mounted on the P.C.C. brick pedestal), suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos Aluminium bus bars of rating not less then 100 amps, Spreader link to incoming/outgoing MCCB for termination of incoming/outgoing cable and Aluminium connecting bars of suitable size (R-Y-B-N) for outgoing cables, duly fabricated in a CPRI approved / certified factory having modern fabrication and testing facility which includes at least seven (07) tanks pre treatment facility comprising of de-greasing, rinsing, de-rusting, rinsing, phosphating, rinsing and passivation followed by powder coated painting (thickness not less than 80 Micron)with approved shade of RAL 7032. The feeder pillar shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The feeder pillar shall be made out of 3.00mm thick CRCA mild steel sheet and 3.00mm thick gland plate and having front opening facility (with double layer shutter) and rear opening facility with single layer shutter with locking facility and 2 side slanting canopy type roof on top and mild steel angle (50x50x5mm) legs of length 30 cm at bottom, suitable for mounting on the pedestal, The feeder pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation, including taking down old unserviceable. The feeder pillar shall be comprising of the followings :-
(i) Incoming : MCCB, 4 pole, 400 Amps, 415 Volts, 25 KA, with adjustable setting, – 01(One) No.
(ii) Outgoing : MCCB, 4 Pole, 250 Amps, 415 Volts, 25 KA, with adjustable setting, – 02(Three) Nos.
(vii) LED indicating lamps with holder for main supply - 1Set of 3
(ix) Change Over 400 Amps - 01 Nos
M&L for Sub Main wiring with two runs of 06 sq mm 1100 V grade (nominal area) single core PVC insulated unsheathed cable multi-stranded copper conductor drawn through medium grade, rigid non-metallic PVC conduit / casing & caping (as per site requirement) of suitable sizewith all necessary fittings, surface in walls/roof/floor duly earthed with one run of single core cable of same size but green in colour as continuous earthing wire and connecting to common earth dolly complete all as specified and directed by Engineer-in-Charge.
Note:-(i) Necessary PVC dummy plates & PVC rigid junction boxes for identifying junction as required on site/directed by Engr-in-charge shall deemed to be included in the quoted rate.
(ii) The wiring shall be done strictly by following proper colour coding using red, yellow and blue for phase, black for neutral and green for earth leads.
(iii) Three runs of cable and one run of PVC conduit / casing caping will be measured as one uint.
S&F Refrigent pipes for suction and discharge lines for connection of Indoor or Outdoor units of 2.0 Ton split AC of standed size as per OEM recommendation with proper insulation including fixing arrangement with powder coated MS clamps and jointing of pipe etc, Complete as specified and directed.
S&F Modular type motor starter 25 Amps for split type air condintioners 4.0 Ton including cover plate and PVC surface box of suitable type complete as specified and directed.
M&L PVC pipe 20 mm dia heavy duty for in walls / roofs condensing water line including making provision for fixing complete all as specified and as directed.
S&F MCCB 4 pole 200 Amps, 16KA breaking capacity, 415Volts 3-phase supply complete all as specified and directed.
S&F of MCCB DB 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provision for 4 pole MCCB incomer, fixed to the existing wall (concealed) and making good the disturbed surface wall with the exsting wall complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ core
Supply and Laying Low Density Poly Ethylene (LDPE) flexible pipe 80mm dia of pressure rating 6 Kg/cm² poles/roof/Wall with necessary clamping easy bending of cables complete all as specified and as directed.
Supply and fix (in repairs) sheet metal enclosure distribution board SPN, 4 ways 240 volts, with 200 amps rated bus bar, with IP 42 protection and double door, suitable for mounting MCBs all as specified and as directed.
OM SAI POWER SYSTEMS
Pragathi Infrastructure Co.
M.chandraiahsons
DURGAI ELECTRICALS
sri ram construction
Sri Tirupati Enterprises
RAJU ENTERPRISES
SRI SAI CONSTRUCTIONS
M/s Amit Associates
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .