executive engineer electrical
Executive Engineer (Electrical), Electrical Divison II, PWD, chepauk Chennai-5
Provision of 5.5TR air conditioning facilities for EIC )T Hall, PWD campus
2026_PWD_693493_1
01E2627
Open Tender
Electrical Works
Lump-sum
chepauk
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹8,700
14 Aug 2026
14 Aug 2026
28 Aug 2026
14 Aug 2026
28 Aug 2026
14 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Design, Supply Installation, testing and commissioning of 5 5 TR nominal capacity Carrier Midea or Equavalant make ceiling suspended High Static Ductable Air conditioner with the Following components. | |||||
| 1.01 | a)5.5 TR capacity ceiling suspended Ductable Air Conditioner high tech, low height, low noise level indoor unit with fin and tube type cooling coil, Detachable type drier provided in refrigerant circuit to reduce moisture content multi stage type distributor for feeding equal quantities of the Refrigerant mixture to all the section of the coil, with required valves, directly coupled blower to reduce troubles and wear & tear compared to belt drive Blower. Thermostatic expansion valve arrangement, lift and pull type aluminium framed durable, washable air filter, Integrated electrical panel with complete microprocessor control with display for easy operation and maintenance of unit common operating conditions of 45 F suction temperature Auto reset type HP/LP safety cut sensor type to improve Reliability of compressor Type QTY-Ceiling Suspended, Blower QTY-1 Nos, Motor Power-415V/3Ph/50HZ, Air Flow-2200cfm. | - | - | - | - |
| 1.02 | B)5.5TR capacity suitable for ceiling suspended Ductable Air conditioner high tech Outdoor unit with power saving high efficiency sturdy and rugged 1 No of scroll compressor each with inbuilt internal thermal protector, internal pressure relief valve, Auto reset type HP/LP safety cut sensor out to improve reliability of compressor and condenser shall be made of super slit high efficient aluminium fins mechanically bonded to copper tubes condenser "L' type coil to be rigidly fixed to unit frame with fasteners imported condenser fan & fan blades to be statically and dynamically balanced to reduce noise and Vibration. The fans are direct driven 3phase motor with protection. Condensing temperature 130°f for the system operations. Refrigerant Compressor Scroll, No of Compressor INo, Refrigerant R410A, Power supply 415V/3PH/50HZ, No of Fan INos, Types of Mounting Rubber mounts with sleeve. | - | - | - | - |
| 2Supply fabrication and erection of Factory fabricated GI made duct with supports, Gasket, etc., for Supply Air Duct | |||||
| 2.01 | Supply, Fabrication and erection of fabricated ducting made up of GI Sheets of 24 Gauge thickness | - | Sqmt | - | - |
| 3Supply and fixing of Thermal Insulation with Aluminium foil, Adhesive, etc | |||||
| 4Supply and providing acoustic for initial portion of ducting with 12mm thick Fibre Glass Rigid Board covered with Tissue Paper and Aluminum Perforated Sheet | |||||
| 5Supply and fixing of Continous Grills/Diffuser for Supply and Return Air, etc | |||||
| 6Supply, Installation, Testing & Commissioning of Heavy Duty hard drawn/soft refrigrant piping with refnet joints | |||||
| 6.01 | Copper refrigerant pipe 28.6 mm | - | Mtrs | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.87 MB
BOQ_833824.xls
BOQ • 0.30 MB
TenderDocument.pdf
Tender Documents • 1.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].