Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.3 LAccepted-AOC C O GENERAL DAIRY VILLAGE BARAGAON SRI GANGANAGAR 335 001 | GANGANAGAR | RAJASTHAN | 335001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹36.9 L+₹50,466.50 (1.39%)Rejected-Finance HOUSE NO 6 18 WARD NO 05 HOUSING BOARD COLONY HANUMANGARH JN 335512 RAJ | HANUMANGARH | RAJASTHAN | 335512 | L2 | Rejected-Finance Highest bid quoted other then L1 | |
| 3 | L3₹37.5 L+₹1.1 L (3.06%)Rejected-Finance H NO 1 BLOCK NO 2 SRI GANGANAGAR 335001 RAJ | GANGANAGAR | RAJASTHAN | 335001 | L3 | Rejected-Finance Highest bid quoted other then L1 | |
| 4 | L4₹39.5 L+₹3.1 L (8.54%)Rejected-Finance | L4 | Rejected-Finance Highest bid quoted other then L1 | |
| 5 | L5₹41.0 L+₹4.6 L (12.6%)Rejected-Finance PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L5 | Rejected-Finance Highest bid quoted other then L1 |
Tender Value
Refer Docs
EMD Value
₹92,900
Closing Date
10 May 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Sri Ganganagar(Raj)
Garrison Engineer Sri Ganganagar, Military Engineer services , Sri GanganagarCantt Rajasthan-335001
SPL REPAIR TO BLDG NO P-590 (1 to 12) OR MD ACCN AT MIL STN SRI GANGANAGAR
2024_MES_649980_1
GE SGNR/TOK-11 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
Sri Ganganagar(Raj)
D Class a(i) and b(i)and for un-enlisted, refer NIT para 8.
7 documents required · 7 mandatory
₹500
GE Sri Ganganagar
₹92,900
Yes
22 Jun 2024
12 Apr 2024
13 May 2024
12 Apr 2024
10 May 2024
26 Apr 2024
Amount
Dismantling brick tiles or terracing tiles, single layer on roofs complete all as specified and directed by Engineer - in - Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer - in - Charge.
M&L for Roof treatment to RCC roof as follows :- (a) Cleaning the roof surfaces thoroughly using wire brushes to remove sharp projections,cleaning joints,washing,drying and removing all dirt/dust to receive concrete padding/ plaster etc complete. (b) Providing 15 mm thick screed bed or bedding layer of cement mortar (1:4) with WPC, finished even and smooth without using extra cement. c) Providing one coat of approved bituminous primer @ 100 gms per sqm, over dried plastered surface. (d) Laying 3 mm thick APP based polymeric membrane,(mineral finish) minimum weighing 3 Kg/Sqm reinforced with non woven polyster fabric (weight not less than 150 gms/Sqm) by torch application. The overlapping while torching shall be 75 mm on longitudinal direction and 100 mm on the transverse direction complete all as specified and directed by Engineer-in-Charge. Notes: (i) All joints and change in directions should be covered with cement mortar (1:3) mixed with SBR latex @ 200 ml/bag of cement/ as per site requirement and cured well before laying membrane by torching. (ii) All angles and abuttments should be sealed well with extra care to ensure full bondage. (iii) Water proofing treatment shall be got carried out by approved authorised applicator of manufacturer only.The name of firm shall be got approved from GE before carrying out the work. (iv) The independent testing of membrane for technical parameters given in particular specifications shall be carried out from Govt approved labs having fascilities for testing of membrane. (v) The guarantee of treatment shall be for minimum 10 years reckoned from date of completion of whole work
Supply and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner. complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (unreinforced) any description and in any position for sunken portion (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
M&L for Water proofing treatment to RCC sunken slab (not exceeding 45cm depth of sunken) as specified below complete all as specified and directed by Engineer-in-Charge:- (a) applying 15 mm plaster in CM 1:3 with WPC on raised verticle surface (b) Cleaning the surface with wire brush/coir brush, removing lose material like dust particles, dirt etc. (c) Creating fillet coving of 50x50 mm with polymer modified mortar on the junction of slab and walls (d) Apply first coat of two component modified polymer coating on the horizontal and verticle surface (e) Provision of glass fiber mesh of 2 x 2 mm immediately on above coating (f) Apply second coat of two component modified polymer coating after 72 hrs (g) Cement concrete 1:4:8 type D-1 using 20mm graded stone aggregate thickness 50mm over the coating as per requirment (h) Joining the saintary pipes with the water proofing tape having bridging ability of more than 1.5 mm (j) Filling the gap between the wall opening and saintary pipe with non shrink cementatious grout complete all as specified and directed by Engineer-in-Charge. Note: (i) PCC filling in sunken portion will be measured seperately.
M&L for PCC (1:5:10) type E-2 (using 40mm graded stone aggregate) as in foundation, filling & mass concrete or filling in sunken floor complete all as specified and directed by Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engineer-in-Charge.
M&L 450x300 x7 mm thick glazed ceramic coloured tiles as in vertical sufaces such as skirting or dado set & jointed in neat cement slurry & pointed in coloured cement to match the shade of tiles laid, over and incliding 10mm thick backing coat in CM 1:4. complete all as specified and directed by Engineer-in-Charge.
M&L Non- skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles laid, over and incliding 15mm thick screed in CM 1:6. complete all as specified and directed by Engineer-in-Charge.
M & L machine cut kota stone slab flooring 18-20mm thick (minimum size 55 cms x 55 cms) over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing laid, over & including 15mm of screed bed in CM 1:6.complete all as specified and directed by Engineer-in-Charge.
M & L machine cut kota stone slabs as in vertical surfces such as risers of steps 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, mirror polishing also moulding edges laid, over & including 10mm of backing coat in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
M&L for Granite (of any type) work 18 to 20mm thick (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and directed by Engr in Charge
M&L Non- skid ceramic coloured tiles 8 to 10mm thick (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the tiles laid, over and incliding 15mm thick screed in CM 1:6. complete all as specified and directed by Engineer-in-Charge.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed by Engineer-in-Charge.
M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe-290(Grade-165) complete all as specified and directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not other wise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-Charge.
M&L providing reinfoced cement concrete (nominal mix) in cement concrete 1:2:4 Type B1(20mm graded aggregate) as chajjas etc and similar work complete all as specified and directed by Engineer-in-Charge. (Note : The rate quoted shall be deemed to include use and waste of necessary form work) complete all as specified and directed by Engineer-in-Charge.
M&L TMT bar 10 mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed by Engineer-in-Charge.
Providing precast RCC Jallies ( cement concrete Type B0 1:2:4 12.5mm gragded aggregate) louvres and jallies, 40 mm thick (measured solid), including all mouldings & set in CM 1:4 and demolition complete all as specified and directed by Engineer-in-Charge.
Demolition concrete in ground floors and pavings n exc 15cm thickness (below or above ground level) complete all as specified and directed by Engineer-in-Charge.
M&L75 mm thick cement concrete type D2, 1:4:8 (Using 40mm graded stone aggregate) filling sub base as in floors, sub floor etc finished even and fair complete all as specified and directed by Engineer-in-Charge.
M&L 25mm thick cement concrete flooring type B0, 1:2:4 using 12.5 mm graded stone aggregate finished even and fair complete all as specified and directed by Engr in Charge.
M&L for sand filling (25mm thick) under floors or in foundations including watering and consolidation complete all as specified and directed by Engineer-in-Charge.
M&L Machine pressed precast rubber moulded concrete coloured interlocking paver block any shape and size confirming to IS 15468-2006 of 60 mm thickness with grey cement and pigment M-35 Grade 20mm graded stone aggregate) complete all as specified and directed by Engineer-in-Charge.
M&L providing precast cement concrete in PCC (1:2:4) type B-1 with 20 mm graded aggregate for kerb stone and similar works with plain fair finishes including chamfers, weatherings, throat- ing etc. and setting in mortar (1:4) complete with joints to match complete all as specified and directed by Engineer-in-Charge.
M & L for 75mm thick cement concrete type C-1, 1:3:6 using 20mm graged aggregate as in plinth protection finished even & smooth complete all as specified and directed by Engineer-in-Charge.
M & L for 40mm thick cement concrete type B-1, 1:2:4 using 20mm graged stone aggregate as in flooring , finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge.
Dismantling of brick work built in cement mortar of any description complete all as specified and directed by Engineer-in-Charge.
M&L brickwork withsub class `B' Bricks (old size), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed by Engineer-in-Charge.
All as above S.No 30 but except bricks complete all as specified and directed by Engineer-in-Charge.
Taking down cement plaster any description including raking out joints, hacking for key and scrubbing down with water etc complete all as specified and directed by Engineer-in-Charge.
M&L 15mm thick rendering in CM 1:6 to brick/ concrete wall surfaces finished even & smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge
M&L 15mm thick rendering in CM 1:4 to brick/ concrete wall surfaces finished even & smooth w/o using extra cement complete all as specified and directed by Engineer-in-Charge.
M&L, 5mm thick rendering in CM 1:3 on fair faces of concrete surfaces as on ceilings finished even and smooth without using extra cement complete all as specified and directed by Engineer-in-Charge
M&L two coats of oil emulsion distemper over & including (1.5mm thick) one coat of wall putty and priming coat on newly plastered wall surfaces including preparation of surface complete all as specified and directed by Engineer-in-Charge
M&L two coats of acrylic weather apex paint & including (1.5mm thick) wall care putty on newly plastered wall surfaces including preparation of surface complete all as specified and directed by Engineer - in - Charge.
M&L three coats of white wash to new surfaces on ceilings with putty finish including preparation of surface complete all as specified and directed by Engineer-in-Charge
M&L two coat of acrylic weather apex paint (with putty finish) to old surfaces of walls after complete removal of existing treatment including preparation of surfaces with putty finishes complete all as specified and directed by Engineer - in - Charge.
M&L two coats of oil emulsion distemper over one coat of priming coat finish after complete removal of existing treatment including preparation of surface with putty finishes complete all as specified and directed by Engineer-in-Charge
M&L two coats of white wash to old surfaces on ceilings with putty finish including preparation of surface complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down chowkats or frames (without taking off shutters from the frame) not exceeding 1.5 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down steel window / ventilators complete all as specified and directed by Engineer-in-Charge.
Taking down shutters of any description exc 1 Sqm but n exc 2 sqm each complete all as specified and directed by Engineer-in-Charge
Taking down shutters of any description exc 1 Sqm but n exc 2 sqm each and refixing in same opening after resecuring easing etc complete all as specified and directed by Engineer-in-Charge
M&L factory made pressed steel frame for doors size 125 x 60 mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc complete all as specified and directed by Engineer-in-Charge. Note : Thickness of MS Sheet shall be 1.25mm.
M&L providing cement concrete (1:3:6) type C1 for filling in pressed steel frames and other similar items etc complete all as specified and directed by Engineer-in-Charge
M&L providing cement concrete (1:3:6) type C2 using 40mm graded stone aggregate foundations, filling and mass concrete complete all as specified and directed by Engineer-in-Charge
S & F 2nd class hard wood plain solid straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered put together with glue pinned at joints complete all as specified and directed by Engineer-in-Charge
S & F 35mm thick shutter, plain, framed, panelled shutters factory made(any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed by Engineer-in-Charge
S & F Factory Made Second class hard wood glazed and skeleton Door, window shutters 30mm thick, open rebated and prepared to receive glass, gauze, etc divided into squares with plain, chamfered or rounded mitred and rebated sash bars any number & fitted with cut and mitred beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, section 8 clause 8.24 (a) complete all as specified and directed by Engineer-in-Charge
S&F 18mm thick HDHMR board prelaminated both side with decorative choice lamination fixed with brass screws to timber frame work including beading in kitchen cabinets, cupboards, wardrobe etc complete all as specified and directed by Engineer-in-Charge.
S&F Factory Made fiber glass reinforced plastic (FRP) Door frames of three legged of cross section 90mmx45mm having single rebate of 32mmx15mm to receive shutter of 30mm thickness. The laminate door frame molded with fire retardant grade unsaturated polyster resin and chopped mat. door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. the frame shall be covered with fiberglass from all sides. M S stay shall be provided at the bottom to steady the frame complete all as specified and directed by Engineer-in-Charge
S&F Factory Made 30mm thick fiber glass reinforced plastic (FRP paneled Door Shitter of required colour and approved brand and manufacture made with fire-retardant grade unsaturated polyster resin. Moulded to 3mm thick FRP laminate for forming places for fixing of fittings cast monolithically with 5mm thick FRP laminate for panels and conforming to IS 14856-2000 complete all as specified and directed by Engineer-in-Charge
S&F 75mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed type C-21 complete all as specified and directed by Engineer-in-Charge
S&F 125 alminium anodies barrel tower bolts of extruded sction and fixed complete all as specified and directed by Engineer-in-Charge
S&F 100mm long butt hinges, medium weight, cold rolled mild steel complete all as specified and directed by Engineer-in-Charge
S&F aluminium handle cast type anodised, 150mm long complete all as specified and directed by Engineer-in-Charge
S&F 300mm long aluminium alloy anodised sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminium alloy and fixed complete all as specified and directed by Engineer-in-Charge
S&F aluminium anodised barrel tower bolts of extruded section 150mm long complete all as specified and directed by Engineer-in-Charge
S&F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed by Engineer-in-Charge
S&F stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge
S&F in repair stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed by Engineer-in-Charge
S & F for floor door stopper of aluminium alloy body and tongue, Overall length of cover plate 140mm anodised, with hard drawn steel spring complete all as specified and directed by Engineer-in-Charge
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick sorrounds, glazed with oil putty or fixed with beads complete all as specified and directed by Engineer-in-Charge
S&F 4mm sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each plane complete all as specified and directed by Engineer-in-Charge
Supply & Fix 4mm thick figured glass, pin head type and glazing with oil putty or fixed with beads in suqares n.exc 0.5 Sqm in each pane complete all as specified and directed by Engineer-in-Charge
M&L anodised aluminium frames for doors, windows with one or moe rebates including jointing cleats for fixing etc.including power coating minimum thickness of power coating shall be 50 micron as per the specification) complete all as specified and directed by Engineer-in-Charge
S&F powder coated aluminium windows and ventilator shutters, side hung type, without sash bars aluminium saction weighing 0.55 kg/RM including necessary jointing cleats, glazing clips, rubber packing, powder coated aluminium snap beading, screws, powder coated aluminium fitting such as peg stay 150mm long (1 no) hinges type B21 100 mm long (2 No) suitable handle (1No) and including aluminium deco grill complete all as specified and directed by Engineer-in-Charge
M&L one coat of synthetic enamel paint on old painted surfaces of wood and wood based materials over 10 cm width or girth including preparation complete all as specified and directed by Engineer-in-Charge
M&L two coats of synthetic enamel paint over a coat of pink primer on new surfaces of wooden and wood based materials over 10 cm width or girth including preparation of surfaces complete all as specified and directed by Engineer-in-Charge
M&L one coat of synthetic enamel paint on old painted surfaces of steel and iron work over 10 cm width or girth including preparationcomplete all as specified and directed by Engineer-in-Charge
M&L, two coats of synthetic enamel paint over a coat of red oxide on steel surface over 10 cm width or girth, not otherwise described including preparation of new surface complete all as specified and directed by Engineer-in-Charge
Suuply and fix in repairs vitreous china wash hand basin white corner type of size 400mm X 400mm, fixed with a set of cast iron brackets including cutting and pinning in ends of brackets to wall, 32mm dia brass chromium plated waste fittings 600mm long PVC connection of 15mm size with PTMT nuts and 40mm dia waste pipe complete all as specified and directed by Engineer-in-Charge
Supply & Fix in repairs white vitreous china squatting pan orissa pattern of size 580mm x 440 mm, with integral foot rest and CI 100mm bore P or S trap connection to trap and to flushing pipe front or back inlet including, trap and taking out old WC & connections etc complete all as specified and directed by Engineer-in-Charge
S&F in repair, 10 ltr capacity low level PVC valveless, syphonic action type flushing cistern(dual system), white, with inlet, ball valve, flush pipe, PVC connection 15 mm dia and 450 mm long float and handle including bracket complete all as specified and directed by Engineer-in-Charge
S&F Soap dish, any type, fixed to plugs with chromium plated brass screws complete all as specified and directed by Engr in Charge.
S & F in repair 20 mm dia gun metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs stop valves, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer-in-Charge
Supply and fixed pillar tap 15mm dia cast copper alloy with capstan heads, chromium plated screwed down high pressure with long screwed for iron pipe of 15 mm dia, fixed in repairs.complete all as specified and directed by Engineer-in-Charge
Supply and fix in repairs Angle stop valves, cast copper alloy 15 mm bore screwed down high pressure with crutch or butter fly handle for iron pipe or for union and complete all as specified and directed by Engineer-in-Charge
S&F in repairs15mm bore bib taps cast copper alloy, chromium plated fancy type with crutch or butterfly handle screwed down screwed for Iron pipe or for brass ferrule and fixed.complete all as specified and directed by Engineer-in-Charge
S&F in repairs PVC connection 15mm size with PTMT nuts of length 450mm long complete all as specified and directed by Engineer-in-Charge
S&F CP gratings 100 mm dia of PTMT fixed in repairs.(Minimum weight 25 gms ) complete all as specified and directed by Engineer-in-Charge
S&F in repairs CP shower rose 125mm size and 15mm dia complete all as specified and directed by Engineer-in-Charge
S&F in repairs CP towel rail 600mm long fixed with CP brass screws complete all as specified and directed by Engineer-in-Charge
Taking up or down GI steel water tubing 15mm bore and connections including fittings from floor/walls/ceiling complete all as specified and directed by Engineer-in-Charge
Taking up or down GI Steel water tubing 20mm bore and connections including fittings from floor/walls/centrings complete all as specified and directed by Engineer-in-Charge
S & F Galvanised steel water tubing 15 mm bore medium grade with all fittings concealed including cutting chases to brick wall/ceiling or laying in floors and making good complete all as specified and directed by Engineer-in-Charge
Fixing only tubes, of 15mm bore any grade,(medium) to walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge
S & F GI steel water tubing 20mm bore medium grade with all fittings and fixed complete to walls ceiling or laid in floors complete all as specified and directed by Engineer-in-Charge
Fixing only tubes, of 20 mm bore any grade,(medium) to walls and ceilings or laying in floors complete all as specified and directed by Engineer-in-Charge
Dismantling water tanks any type exc. 500 ltr but nexc 1000 ltr complete all as specified and directed by Engineer-in-Charge
S & F rotational moulded polythylene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part -I (500 Ltrs) capacity complete all as specified and directed by Engineer-in-Charge. Water Tank Shall be ISI Marked and having two layers.
Supply and fixing ball valves high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed for bore dia of pipe 20mm complete all as specified and directed by Engineer-in-Charge.
Dismantling of cast iron or reinforced concrete drain pipes 100mm bore & 75mm bore jointed in cement mortar and taking out of trenches, if required complete all as specified and directed by Engineer-in-Charge. .
M&L for 100mm dia cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm dia cast iron sand cast waste and vent pipes in any length with or without ears with cement jointed fixed to wall complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm dia cast iron Bends complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm dia cast iron Bends complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm dia cast iron Branch pieces single complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm dia cast iron Branch pieces single complete all as specified and directed by Engineer-in-Charge.
M&L for 100mm dia cast iron Sockets complete all as specified and directed by Engineer-in-Charge.
M&L for 75mm dia cast iron Sockets complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes,PVC (SWR) pipes ( any size or pattern ) including all fittings heads ,shoes, bends, and removal to store complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls including necessary scaffolding upto the height of building from ground leve complete all as specified and directed by Engineer-in-Charge.
S&F 110 mm dia PVC (SWR) bend complete all as specified and directed by Engineer-in-Charge.
Supply and fixing drapery curtain rod 25mm dia, fancy type, fabricated out of stainless steel steel sheet not less than 20 guage, including brackets and pair of decorated end knobs (finials), stop roller etc, complete stainless steel complete all as specified & directed by Engineer-in- charge.
S & F in repairs 15mm bore dia 3 in 1 brass CP wall Mixer for mixing Hot and Cold water (spout and overhead shower) including 115 long bend pipe, connecting legs and wall flange without shower rose screwed for iron pipe and fixed complete all as specified and directed by Engineer-in-Charge.
S & F in repair Sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cemen mortar on to dwarf wall or including fixing cantilever brackets, waste coupling, waste pipe and connectiong union to pipe, overall size 610 x 460mm bowl size 560mm x 410mm x 257mm complete all as specified and directed by Engineer-in-Charge.
S & F Kitchen Plate Rack Stainless steel 900 x 750 x 270 mm thickness of sheet not less than 1 mm complete all as specified and directed by Engineer-in-Charge.
S&F PTMT mirror cabinet of size 400 x 500mm and 100mm to 130mm depth, premium quality and fixed to wall with chromium plated brass screws and cup washers complete all as specified and directed by Engineer-in-Charge.
S&F Corner glass shelve 5.5mm thick with chromium plated/SS bracket guard and railing, fixed with CP Brass screws to wall complete all as specified and directed by Engr-in-Charge.
S&F glass shelves 18"x5 1/2", 5.5mm thick glass with chromium plated/SS bracket guard and railing fixed with CP Brass screws complete all as specified and directed bt Engr-in-Charge.
S&F Aluminium wardrobe/bathroom hooks 6 hooks in each complete all as specified and directed by Engr-in-Charge.
S&F Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) Engr-in-Charge.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power, bell complete fitting such as sockets, ceiling roses, pendants, batten holders, regulators and making good the disturbed surfaces of wall, floors, ceiling in CM 1:3 etc complete all as specified and directed by Engineer - in - Charge.
M & L for concealed conduit point wiring complete for light/fan on independent /combine board with cable 1.5 sqmm (Nominal area) FRLSH PVC insulated multistranded unsheathed copper conductor, drawn in and including PVC Concealed conduit pipe medium grade 20 mm dia, pipe hooks , elbows, juction covers and junction boxes , after cutting in wall chasing for conduits and sinking's for sunken cast iron/ pressed steel terminal boxes suitable length and thickness for mounting, switches, sockets,fan regulator with 3 mm thick plastic laminated sheet cover fixed with brass screwed and cup washers, duly grouting and painted with red oxide metal primer and making the good disturbed surfaces of wall in CM 1:3 with white wash or existing colour including provision of continuous earth continuity conductor along with point wiring of 1.5 sqmm copper PVC insulated cable for one light/ fan point controlled by one switch and connected to common earth dolly, complete all as specified and direced by the Engineer in charge.
All as per Srl item No. 121 here in before but for one switch socket combination 5/6 amp on independent board complete all as specified by Engineer-in-Charge.
All as per Srl item No. 121 here in before but for one three pin socket outlet 5 amp on same board complete all as specified by Engineer-in-Charge.
All as per Srl item No. 121 here in before but for one switch socket combination 6 pin 5/15 Amp on independent board with copper conductor 2.5 Sqmm complete all as specified by Engineer-in-Charge.
All as per Srl item No. 121 here in before but for one light point controlled by two 2 ways switches complete all as specified by Engineer-in-Charge.
All as per Srl item No. 121 here in before but for call bell point complete all as specified by Engineer-in-Charge.
S&F Switch piano flush type 5/6 Amps single pole one way complete all as specified by Engineer-in-Charge.
S&F Switch piano flush type 5/6 Amps single pole two way complete all as specified by Engineer-in-Charge.
S&F bell push type 5 Amp complete all as specified by Engineer-in-Charge.
S&F Switch socket combination 5 pin, type 5/6 Amps flush type complete all as specified by Engineer-in-Charge.
S&F Switch socket combination 6 pin, type 5/16 Amps flush type complete all as specified by Engineer-in-Charge.
S&F Socket outlet 5 pin 5 Amps flush type complete all as specified by Engineer-in-Charge.
S&F ceiling rose surface bakelite three terminals flush type complete all as specified by Engineer-in-Charge.
S&Felectronic bell AC 230 Volt single pole ding dong type complete all as specified by Engineer-in-Charge.
S & F in replacement of existing light fitting with LED batten with aluminium housing and integrated electronic driver, 20/22 watt having input voltage AC90-300V, 50 Hz , 6500K, and all other accessories including connection with flexible cable copper conductor two core of size 23/.2 mm upto ceiling rose/connector complete all as specified and directed by Engineer - in - Charge.
S & F angle holder insulated body with back plate for conduit fittings complete all as specified and directed by Engineer - in - Charge.
S & F LED lamp 9W for angle holder complete all as specified and directed by Engineer - in - Charge
S&F LED light fitting 1x9W/1x10W bulkhead luminaires including LED light driver holder connection up with three core flexible copper conductor cable of suitable size complete all as specified and directed by Engineer - in - Charge.
S&F stepped type, single socket fan regulator for ceiling fan 1200/1400mm sweep complete all as specified and directed by Engineer - in - Charge.
S&F in replacement of sub-main wiring with two single core cables PVC insulated and un-sheated 6 sqmm (Normal Area) FRLSH stranded copper conductor drawn in and including pvc conduit dia 20mm "medium quality" conduit including 6.00 sqmm (Norminal Area) copper cable as earth continuity conductor after chasing in wall and making good the disturbed surfaces and white wash or existeing colour, necessary juction box and covers including necessary connections, PVC flexible pipe are used in pannel board while connecting the cable complete all as specified and directed by Engineer - in - Charge. (Note : (i) PVC cable and PVC conduit shall be ISI marked, (ii) Two Runs of two single core cable, one run of earth cable & PVC Conduit shall be measured as "One Run")
S&F in repairs sheet metal enclosure for double door DB made out of CRCA mild steel sheet surfae with insulated material like polyester with epoxy powder coated surface mounted SP & N 12 ways, 240 volts ISI makred 200 amps bus bar stove enameled dust and vermin proof suitable for incorporation MCBs and isolators etc complete all as specified and directed by Engineer - in - Charge.
S&F in repairs MCCB TP&N 63 Amps with breaking capacity 16KA, Fixed TM and 415 volts AC Supply ISI marked complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘C’ series type suitable for 240 volts, AC supply 5 to 40 Amps, S P & N with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
S & F in replacement MCB ‘B’ series type suitable for 240 volts, AC supply 5 to 40 Amps, single pole with over load and short circuit protection and rupturing capacity not less than 10KA complete all as specified and directed by Engineer - in - Charge.
M & L for Earthing complete with GI earth plate electrode 60 cm x 60 cm x 6 mm thick burried directly in ground (earth pit not less than 2.25 Mtr deep below ground level ) with top edge of plate not less than 1.5 Mtr below ground level , connecting to GI earth lead 4 mm dia GI earth wire ,by means of bolts,nuts and washers of GI and protection by provision of GI medium grade pipe 15 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20 mm grade stone aggregate with 40 mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 gs /Sqmm ) and frame of angle iron 25mmX25mmX6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape ,GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed ontop edge of earth plate common salt and charcoal filling test point made out of 40 mmX 8 mm FI with fixing arrangement ,funnel, wire mesh and earth work inhard dense soil ,returning filling in and removal of surplus soil to a distance not exceeding 50 mtrs all as per electric plate No.3 of SSR Part I and connecting to earth test point including taking out unserviceable earthing with all acessories all as specified or indicated including testing on completion all as specified and directed by Engr -In - Charge
S&F in replacement security light fitting LED TYPE 20 watt with all necessary acessories, Clear transparent acrylic cover, prewire suitable to operated on 230 volt 50 HZ AC & Supply and fixing to wall / on pole including fixing arrangement with suitable galvanized iron pipe 35 mm bore “light grade” brackets 2 mtr length bent to shape to obtained required shape including clamps, nuts / bots / washers etc connecting with suitable flexible copper wire of size 23/0.0076 complete all as specified and directed by Engineer - in - Charge .
S&F in repairs sheet metal enclosure for double door DBs made out of CRCA mild steel sheet surfae with insulated material like polyester with epoxy powder coated surface mounting VTPN 4 ways, 415 volts ISI makred 250 Amps bus bar stove enameled dust and vermin proof, IP:43 protection suitable for incorporation FP MCCB (V-Tech) N1 Frame upto 125A, Isolators and including give connection with wire and cable etc complete all as specified and directed by Engineer - in - Charge.
Excavation in trenches not exceeding 1.5 mtr wide and not exc 1.5 mtr depth for laying of cables including taking up or down the LT Cable complete all as specified and directed by Engr-In-Charge.
Returning filling in including spreading levelling watering and well ramming in layers not exceeding 25cm complete all as specified and directed by Engr-In-Charge.
Removal of Excavted material n exceeding 50 mtr and depositing whrere complete all as specified and directed by Engr-In-Charge.
Supply and lay standard size bricks sub class B type complete all as specified and directed by Engr-In-Charge.
Supply and lay jointing and testing and commissioning in replacement of 25 Sqmmx4 core XLPE insulateed, screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty multi stranded aluminium conductor & PVC sheathed LT cable 1100 V grade conforming to IS-7098 laid in trenches / ducts / fixed on poles wall / laid under roads / paths / drain / culverts or passing through pipes complete all as specified and directed by Engr-In-Charge.
Supply and fixing of suitable size meter box of min size (0.9m X 0.9m X 0.2m), made out of polycabonate box double door singple opening with lock arrangement and transparent glass for meter reaindg suitable for fixing 04 Electric / Smart meter & VTPN BD box including taking down existing electric meters, refing them with two single core PVC copper conductor unsheathed wire multistranded 4 sqmm, properly painting on meter box complete and fixing in wall with suitable cutting, cement work etc complete all as specified and directed by Engr-In-Charge.
S&F heavy duty steel body exhaust fan of 300mm sweep, 240 volt, 5 Star rating complete with louvers and shutter and mounted in suitable opening arrangement in wall and connection up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including braking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in CM (1:4) white washing matching with existing color etc complete all as specified and directed by Engr -In - Charge
S&F exhaust fan made of sturdy engineering plastic of 250mm sweep, 240 volt, complete with louvers and shutter and mounted in suitable opening arrangement in wall and connecting up including 3 core PVC insulated PVC sheathed copper conductor flexible cable 24/0.2mm from ceiling rose to fan complete including braking of brick wall and making a hole for fixing of exhaust fan including grouting of bolts and making good to disturbed wall in CM (1:4) white washing matching with existing color etc complete all as specified and directed by Engr -In - Charge
S&F 3.15mm thick plain mild steel wire galvanized Class-3, in cloth hangers including straining and fixing to wood, concrete or steel post and or to straining bolt complete all as specified and directed by Engr -In - Charge
M&L for providing PCC 1:2:4 type B0, (12.50 mm graded stone aggregate) in roof kerbs, or mud stops or undulated roof rounded or chanferred at edges complete all as specified and directed by Engr -In - Charge
Taking down, easing, adjusing and refixing of door shutter of size exc. 1 sqm but n.exc 2.00 sqm each any type in the same opening and also refixing builders hardware as required complete all as specified and directed by Engr -In - Charge
Cutting holes and making good with serviceable bricks/concrete to match with adjoining surface in brick work built in cement mortar exc. Half brick wall but n. exc one brick wall for embedded hold fast of door or window frame complete all as specified and directed by Engr -In - Charge
S&F eye hole premium qulaity, 200⁰ wide magic eye viewer with fixing nuts and washers (quoted rates included for drilling hole and fixing complete) complete all as specified and directed by Engr -In - Charge
S&F in repairs CP Brass double angle valve (for two connections) 15mm bore screwed down high pressure with liver type handle, quarter turn for iron or union complete all as specified and directed by Engr -In - Charge
Note :(i) Amount of credit for retrieved materials is mentioned in Sch 'A' Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline.
R B Infrabuilders
Gyan Chand Marothia Engineer Contractor And Suppliers
M/s HANS BROTHERS
M/S BUDHRAM BISHNOI
AYUSH BUILDERS
Akarsha Enterprises
J and P CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .