Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC NEAR SVN UNIVERSITY NARSINGHPUR ROAD SIRONJA SAUGOR MP 470228 | SAUGOR | SAGAR | MP | 470228 | L1 | Accepted-AOC Being lowest and reasonable bidder | |
| 2 | L2₹9.0 L+₹46,501 (5.46%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹10.4 L+₹1.9 L (22.1%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | Paragon Electrotechnics L3 | M/S JAINENDRA KUMAR JAIN L1 | SONA LAKSHMI ASSOCIATE L2 |
|---|---|---|---|---|---|---|
| 1.00 | S & F for Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 50mm outer diameter and 38 mm inner Diameter suitable for laying of electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge. | 390 | RM | 55 ₹21,450 | 50 ₹19,500 Lowest | 50 ₹19,500 Lowest |
| 2.00 | S & F for Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 63mm outer diameter and 50 mm inner Diameter suitable for laying of electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge. | 90 | RM | 65 ₹5,850 | 70 ₹6,300 | 60 ₹5,400 Lowest |
| 3.00 | S & F for Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 90mm outer diameter and 75 mm inner Diameter or suitable for laying of Electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge. | 330 | RM | 110 ₹36,300 | 90 ₹29,700 Lowest | 90 ₹29,700 Lowest |
| 4.00 | S & F for Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 120mm outer diameter and 102 mm inner Diameter for laying of Electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge. | 320 | RM | 125 ₹40,000 | 120 ₹38,400 Lowest | 140 ₹44,800 |
| 5.00 | M & L for boring of holes under road, pavement, hard standing by trenches technoligy using sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed. | 6 | RM | 2,500 ₹15,000 | 500 ₹3,000 Lowest | 1,403 ₹8,418 |
| 6.00 | Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed. | 12 | RM | 450 ₹5,400 Lowest | 480 ₹5,760 | 500 ₹6,000 |
| 7.00Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor, stranded, armoured, PVC sheathed, LT 1100 Volts grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for following sizes: - | ||||||
| 7.01 | 120 sqmm, 3.5 core | 150 | RM | 920 ₹1,38,000 | 710 ₹1,06,500 Lowest | 800 ₹1,20,000 |
| 7.02 | 95 sqmm, 3.5 core | 170 | RM | 725 ₹1,23,250 | 560 ₹95,200 Lowest | 600 ₹1,02,000 |
| 7.03 | 70 sqmm, 3.5 core | 170 | RM | 580 ₹98,600 | 450 ₹76,500 Lowest | 500 ₹85,000 |
Tender Value
₹10 L
EMD Value
₹20,000
Closing Date
10 Feb 2026, 6:00 pmClosed
AGE (I) AF Sonegaon, Nagpur
Bldg P-51, 44 Wing AF Station Sonegaon, Nagpur 440005
REPAIR/ REPLACEMENT OF EXTERNAL ELECTRIFICATION AND OTHER CONNECTED WORKS AT AF STN SONEGAON, NAGPUR
2026_MES_749272_1
8556/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Sonegaon
As per NIT
8 documents required · 8 mandatory
₹500
Yes
AGE (I) AF Sonegaon
₹20,000
Yes
13 Mar 2026
20 Jan 2026
17 Feb 2026
20 Jan 2026
10 Feb 2026
3 Feb 2026
20 Jan 2026 - 2 Feb 2026
S & F for Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 50mm outer diameter and 38 mm inner Diameter suitable for laying of electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge.
S & F for Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 63mm outer diameter and 50 mm inner Diameter suitable for laying of electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge.
S & F for Double Wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 90mm outer diameter and 75 mm inner Diameter or suitable for laying of Electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge.
S & F for Double wall Corrugated High Density Polymer Ethyl (HDPE) pipe of size 120mm outer diameter and 102 mm inner Diameter for laying of Electric cable with IS 14930 (part 2) 2001 and 6 mm thickness laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed by Engineer- in -Charge.
M & L for boring of holes under road, pavement, hard standing by trenches technoligy using sounding technique and necessary machine including HDPE pipe of 150mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
Supplying and laying GI pipe Light grade (ISI marked) 50mm bore with connecting accessories, laid under road/ drain/fixed on wall etc for protection of cables complete all as specified and directed.
Supplying, laying, testing and Commissioning cable XLPE insulated aluminium conductor, stranded, armoured, PVC sheathed, LT 1100 Volts grade, heavy duty as per IS-7098 and providing suitable lugs and cable glands, laid in trenches/ ducts/fixed to wall/ roof/ poles including taking down existing cables complete all as specified and directed for following sizes: -
120 sqmm, 3.5 core
95 sqmm, 3.5 core
70 sqmm, 3.5 core
50 sqmm, 3.5 core
35 sqmm, 3.5 core
25 sqmm, 3.5 core
16 sqmm, 4 core
10 sqmm, 2 core
Supply and fix Isolator TPN 63 A 415 Volts 10 KA breaking Capacity 'C' Series characteristics mounted on DIN Rail and connecting up complete all as specified and as directed.
Taking down old unserviceable MCCB and Supply and fix MCCB 125 A, 4 pole, 415 Volts 36 KA breaking Capacity, AAN frame fixed on Existing panel in power house/feeder panel and connecting up all as specified and as directed& in the process of fixing of MCCB minor drilling, clamping, screw, nut bolt included in quoted rate complete all as specified and directed.
Ditto all as per Item No 9.00 above but for 100 Amp.
Ditto all as per Item No 9.00 above but for 200 Amp.
Taking down old unserviceable cable route indicator and S & F Cable route indicator / Marker made up of PCC block in cement mortar 1:3:6 (20 mm graded aggregate) of size 900 x 300 x 100 mm thick with DANGER / 440 VOLTS, LT CABLE / MES embossing on cable route indicator / Marker including painting as per approved colour and buried in ground 45 Cms including necessary earth work (as required / ordered at site) complete all as specified and as directed.
S & F for cable jointing kit for 1.1 KV grade cable for straight through joint complete with jointing material cold shrink type and accessories suitable for 3.5/4 core XLPE, armoured, Aluminium conductor cable of size 50 to 95 Sqmm complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level, connected to GI strips of size 32 x 6 mm as earthling lead by means bolts and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber, MS funnel, wire mesh. CI cover with frame etc including necessary excavation in any type of strata, returning, filling removal of soil outside MD land, filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I, connected to Earthing test point and testing on completion complete all as specified and as directed.
All as per item No. 14.00 above but using Copper plate 600mmx600mmx3.15mm thick electrode and 20x3mm copper strip as Earthing lead complete all as specified and directed.
M & L for Earth continuity conductor with copper strip 32 x 6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. complete all as specified and directed.
Excavation in trenches not exc. 1.5 meter wide and not exc 1.5 meter in depth and getting out in any type of soil for laying of cable, pipe etc., complete all as specified and directed.
Returning filling in and including spreading, levelling, watering and well ramming in layers not exc. 25cm thick, complete all as specified and directed.
Removal of excavated materials to a distance not exc. 50 meter and depositing where directed at a level not exc. 1.5 meter above the starting point complete all as specified and as directed.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.63 MB
BOQ_839115.xls
BOQ • 0.34 MB
TD8556Externalelectrification.pdf
Tender Documents • 1.21 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .